Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #57986893

Tender For Repair/Maint Of Internal/External Electrification System, B/R Works And Other Connected Works Such As Fire Fighting Eqpt Water Supply Pipe Line Submersible Pump At Water Supply Installation At Prabudh Vihar (Pcda) Devikhera Under Ge E/M Lu

Issued by Statutory Bodies & Commissions/Committees · Lucknow, Uttar Pradesh
Tender Value
48.99 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
15 days left
EMD
97980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal/External Electrification System, B/R Works And Other Connected Works Such As Fire Fighting Eqpt Water Supply Pipe Line Submersible Pump At Water Supply Installation At Prabudh Vihar (Pcda) Devikhera Under Ge E/M Lucknow

BOQ

Name of Work:- REPAIR/MAINT OF INTERNAL/EXTERNAL ELECTRIFICATION SYSTEM, B/R WORKS AND OTHER CONNECTED WORKS SUCH AS FIRE FIGHTING EQPT WATER SUPPLY PIPE LINE SUBMERSIBLE PUMP AT WATER SUPPLY INSTALLATION AT PRABUDH VIHAR (PCDA) DEVIKHERA UNDER GE E/M LUCKNOW
Sl. No. Item Description
1Taking down chowkhat or frames (wooden / aluminium / iron) with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed.
2Taking down chowkhat or frames (wooden / aluminium / iron) with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n exc 4.00 Sqm each complete all as specified and as directed.
3Taking down shutters of any description area exc 1 Sqm and n exc 2 Sqm each complete all as specified and directed.
4S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.
5S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
6S&F plain solid, straight chowkhat & frames of 2nd class HW wrought, framed rebated on the solid, rounded or chamfered, put together with glue & pinned at joints including preparation of back of chowkats & treated with coal tar complete all as specified and directed.
7S&F 30 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, one face is covered with decorative face veneer with lipping/frame to match commercial type on both sides complete all as specified and directed.
8S&F 35 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, one face is covered with decorative face veneer with lipping/frame to match commercial type on both sides complete all as specified and directed.
9S&F 30mm thick of 2nd class HW glazed and skeleton shutters in chowkats, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fixed to chowkhats,complete all as specified and as directed.
10S&F 18mm thick factory made 100% solid WPC flush shutter (for cupboard, wardrobe ,etc) made from co-extruded three layer rigid foam sheet Single extruded) with 0.8 to 1mm thick outer layer having density not less than 1400kg/cum and density of center core not less than 600kg/cum, with prelamination on both front and back side manufactured by and ISO 9001/2015 certified company complete all as specified and directed.
11Supply and fixing 30 mm width of flaps (when open) continuous piano hinges Mild steel, bright finish or electroglavanised complete all as specified and directed.
12S&F magnet ball catcher with 8 mm dia steel bal and brass body and strike plate magnet ball catcher for cup board shutters complete all as specified and directed
13S&F 100mm long M S Chromium Plated, hasp and staple, safety type, with mild steel hinge pin including bolts to hinge plate and fixed with screws complete all as specified and directed
14S&F in repair magnet ball catcher with 8 mm dia steel bal and brass body and strike plate magnet ball catcher for cup board shutters complete all as specified and directed
15S&F in repair 100mm long M S Cromium Plated, hasp and staple, safety type, with mild steel hinge pin including bolts to hinge plate and fixed with screws complete all as specified and directed
16S&F 250 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed, complete all as specified and directed.
17S&F 300 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed, complete all as specified and directed.
18S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, 150 mm length of bolt complete all as specified and directed.
19S&F 100 mm size butt hinges medium weight , rolled mild steel complete all as specified and directed.
20S&F 125 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
21S&F 150 mm floor door stopper of aluminium alloy body and tonged, anodised with hard drawn steel spring, complete all as specified and directed.
22S&F in repair 250 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed, complete all as specified and directed.
23S&F in repair 300 mm aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extruded section or cast aluminium alloy and fixed, complete all as specified and directed.
24S&F in repair Aluminium, anodised, barrel tower bolts of extruded section and fixed, 100 mm length of bolt complete all as specified and directed.
25S&F in repair Aluminium, anodised, barrel tower bolts of extruded section and fixed, 150 mm length of bolt complete all as specified and directed.
26S&F in repair 100mm size butt hinges medium weight , rolled mild steel complete all as specified and directed.
27S&F in repair 125mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
28S & F in repair mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
29S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
30S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
31Hacking out old broken glass, any thickness, size, quality, or description, from frame n.exc 1.5 Sqm each pane, complete all as specified and directed.
32S&F 3.0 mm thick figured glass ordinary quality and glazing with oil putty / wooden beading / aluminium beading n.exc 0.5 Sqm each pane, complete all as specified and directed.
33S&F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beading / aluminium beading exc 0.5 Sqm each pane, complete all as specified and directed.
34S&F in repair curtain rod 20mm dia mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and directed.
35S&F aluminium powder coated fancy type domes cum bracket (20 mm dia) fixed to both ends of the drapery rod and wall complete all as specified and directed.
36Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level), complete all as specified and directed.
37M&L for 40 mm thick PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in flooring including finishing the top surface even and smooth, without using extra cement complete all as specified and as directed by Engineer-in-charge.
38M&L for 75 mm thick plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate, as plinth protection / path and the like, finished even and smooth without using extra cement all as specified and as directed.
39M&L for 75 mm thick plain cement concrete 1:4:8, type D- 2, using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
40Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc. Laid dry or laid dry and Pointed complete all as specified and directed.
41M&L for 60 mm thick factory made chamfered edge cement concrete interlocking paver block of M-35 grade, in gray cement with approved design & pattern / shape laid as in foot path, / hard standing / drive ways or parking etc., made by table vibratory method using PU mould, laid over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks over the the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
42Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including removal of debries from site, complete all as specified and directed.
43M&L for non skid ceramic coloured tiles 7-8 mm thick (square or rectangular) polished area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.(Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE)
44M&L for for coloured glazed ceramic tiles in vertical surfaces of size 350 x 250 x 7 mm/450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, over and including 10 mm thick backing coat in cement mortar (1:3),complete all as specified and directed.(Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE)
45M&L for coloured vitrified ceramic tiles (joint free) 10 mm thick (Square/Rectangular) area of each tile n exceeding 0.36 sqm in floor area, etc set over and including 15 mm thick cement mortar (1:6) screed bed, set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and directed.(Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE)
46M&L for coloured vitrified ceramic tiles (joint free) 10 mm thick (Square/Rectangular) area of each tile n exceeding 0.36 sqm as in skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, over and including 10 mm thick backing coat in cement mortar (1:3),complete all as specified and directed.(Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE)
47Demolition of stone slab of any description / thickness in floors, aprons etc including cement mortar bedding laid bedded and pointed in any mortar, complete all as specified and directed.
48M&L for 20 mm thick granite (of any type) tiles as in floor machine cut & machine polished, set & jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including screed bed 15 mm thick in cement mortor 1:4, complete all as specified and directed.Note: Design, shade and pattern of fixing of granite shall be as directed and approved by GE.
49M&L for chequered cement concrete tiles (glossy finish) 300mm x 300mm x 25 mm thick of size, set , jointed and pointed using with grey cement and pigment in floors, paving etc. including the setting and jointing in neat cement paste or slurry @0.3kg/Sqm over and including 20 mm thick screed bed or bedding layer in cement mortar (1:6) complete as per manufacturer instructions and direction.Note: Design, shade and pattern of fixing of chequered tiles shall be as directed and approved by GE.
50Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or remove to store complete all as specified and directed.
51Taking up or down 20 mm dia bore steel tubing and connection including cleaning for refixing or remove to store complete all as specified and directed.
52Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.)15 mm nominal bore complete all as specified and directed.
53Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.)20 mm nominal bore complete all as specified and directed.
54S&F GI tubing 15mm bore medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), including screwing and waste and for forged bends on piping as required, complete all as specified and as directed.
55S&F GI tubing 20mm bore medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), including screwing and waste and for forged bends on piping as required, complete all as specified and as directed.
56Supply and fix 500 litres capacity double layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position all as specified in SSR Part-I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc including dismantling old unseviceable tank, complete all as specified and as directed.
57S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, suitable for 20 mm bore pipe, screwed for iron pipe and fixed (Minimum weight 20mm-210gms), complete all as specified and directed.
58Disconnecting existing tank of capacity 500 ltrs, setting aside or lowering if required and reconnecting or refixing in same positing or other position, including cleaning and removing all scale and dirt etc from tanks and from the mouths of circulating pipes etc complete all as specified and directed.
59S&F in repairs 15 mm size bib tap, with wall glange, long body, cast copper alloy chromium plated, fancy type with capston head, screwed for 15 mm bore iron pipe or for brass ferrule and fixed complete all as specified and directed.
60S&F in repair 15 mm size Concealed stop cock, cast copper alloy, chromium plated, Reduced body ISI Marked, screwed down, high pressure, with capston head, screwed externally both ends for unions etc. and fixed complete all as specified and directed.
61S&F in repair 15 mm size Angle cock / valve, cast copper alloy, chromium plated, fancy type with capstan head, with screwed down, screwed both end for iron pipes ,complete all as specified and directed.
62S&F in repair 15 mm size two way Angle cock / valve, cast copper alloy, chromium plated, fancy type with capstan head, with screwed down, screwed both end for iron pipes ,complete all as specified and directed.
63S&F in repair 15 mm size two way stop cock cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipes, complete all as specified and directed.
64S&F in repair 15 mm size pillar taps, cast copper alloy, chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
65S&F in repairs 15 mm size swan neck pillar taps, cast copper alloy, chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and directed.
66S&F in repairs 15 mm size wall mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed.
67S&F in repair 15 mm size basin mixer cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe with 450 mm braided connection pipe complete all as specified.
68S&F in repairs 600 mm x 450 mm bevelled edge mirror 5.5 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP Brass screws and cup washers complete all as specified and directed.
69S&F in repairs Brass chromium plated shower rose 80 mm size without swivel joints, including fixing to steel pipe or union complete all as specified and directed.
70S&F in repair ABS plastic chromium plated Health faucet fixed with spring action and lever along with Flexible hose with brass nut of length 1 m to 1.2 m fitted in the existing water connection in the toilets, Complete all as specified and directed.
71S&F in repairs CP mild steel gratings suitable for 75 / 100 mm dia for Nahani trap/ Floor trap, complete all as specified and directed.
72S&F in repair PVC connection 15 mm size with PTMT nut, length 450 mm, complete all as specified and directed.
73S&F in repair PVC connection 15 mm size with PTMT nut, length 600 mm complete all as specified and directed.
74S&F in repair 32 mm size flexible pipe of PVC fixed to WHB / urinals as waste pipe (not less than 600mm long) including PVC coupling complete all as specified and directed.
75S & F in repair PVC Syphon Kit with complete fittings for low level flushing cistern complete all as specified and directed.
76Demolition of sunken slab floor or WC and Bath including WC trap etc incl taking down loose filling of aggregate in any type and removing where direted and providing water proofing treatment of sunken slab in following (a) 15mm thick rendering on vertical sides of RCC slab in CM 1:3 mixed with WP chemical Cement of Nerolac Perma/STP/Asian or equivalent Confirm to IS 2645 - 9103 as per manufacturer instructions. (b) Cleaning the concrete surface by brushing and watering and remove all surface inperfections. (c) Fixing 40mm dia PVC Pipe 450mm long bottom of the sunken and wraping of bath seal tape on the pipes inserted through walls to floor are and seal it (Perma Butyl tape product of Nerolac Perma/ STP/Asian or equivalent and grouting around the inserted pipes by porable grout as directed by Engr-in-Charge.(d) Make angle fillets by mixing sand cement and Nerolac Perma Hypercrete/STP/Asian or equivalent on all corners.
77(e) Brushing two coats with high performance cementitious elastomeric two components water proofing coating of Nerolac Perma Super 2K/STP/Asian or equivalent of thickness 1mm in two coats, Above treatment shall be giving upto height 15cm from bottom slab and allow it dry completely. Above material shall be confirm to below properties- 1. Bulk Density - 1.73g/cc, 2. Elongation - 100% as per ASTM D412 (Min) 3.Hydrostatic Pressure - 4bars as per ASTM D 7088, 4. Adhesion to concrete- Greater than 1.5N/mm2, 5. Crack Bridging ability as per AS/NZS 4548.5 Min 1mm. 6. DFT - 1mm in two coats. Seperation Layer- Providing & Laying 120 gsm non woven geo textile membrane over waterproofing coating to protect the coating prior the screed.(f) Providing PCC 1:4:8 type D-2 using 40mm graded stone aggregate mixed with intergral waterproofing compound Cement + of Nerolac Perma as per manufacturer instructions in sunken slab.(g) Fill the sanitary gaps with Nerolac PermaSIKA/Asian or equivalent sealing compounds complete all as specified and as directed.
78M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate for filling in sunken slab, complete all as specified and as directed.
79S&F in repair vitreous china wash down water closet (Padestal pattern) white with P or S trap, with and including white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device with 32mm dia polyethylene flush pipe etc (excluding fixing bolts flushing cistern and flush pipe) including connection to drain (outgoing pipe), complete all as specified and as directed.
80S&F in repairs vitreous China Squatting pan ‘Orissa’ pattern, size (580 x 440)mm, white, with integral foot rests and with ‘P’ or ‘S” trap, (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe, etc with and including provision of lime concrete bedding, including making good to existing (floor / Tiles) complete all as specified and as directed.
81S&F vitreous china wall hung/Floor mounting WC, UF seat close seat cover, hinges, accessories set of size 360 x 580 x 360 mm fixed to wall/floor with P/S trap (one piece) (cascade type) of specified make with including flushing cistern & white seat cover, complete all as specified and ditected.
82S&F in repair PVC low level flushing cistern, valveless, syphonic action type, double push botton, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection, complete all as specified and as directed.
83S&F in repairs Plastic water closet seat cover, white, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device,complete all as specified and directed.
84M&L 100 mm bore cast iron 'P' or 'S' trap fixed complete with joint to cast iron 100 mm bore pipe duly fixed in position in repairs complete including closing the wall opening in cement mortar 1:3, complete all as specified and directed.
85S&F in repair 75 mm dia cast iron floor trap with chromium plated grating including jointing to waste pipe wih cement mortar , complete all as specified and directed.
86M&L for preparation of new wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint (first Quality) over a coat of pink primer complete all as specified and directed.
87M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping holes and applying one coat of synthetic enamel paint (first Quality) complete all as specified and directed.
88M&L for preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, and applying one coat of synthetic enamel paint (first Quality) (up to 25 mtrs height) complete all as specified and directed by Engineer-in-Charge
89M&L for complete removal of existing treatment of wall / roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vacuum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour and applying 2 mm thick wall care putty, two coats of oil bound distemper (first Quality) of any tint / shade over one coat primer, complete all as specified and directed.
90M&L for preparation of old painted surfaces of ceiling by washing, rubbing down & stopping etc, and applying one coat of oil bound distemper (first Quality) of any tint / shade complete all as specified and directed.
91Desluding/Dewatering of blocking of inlet of septic tanks / manhole of depth 0.50 to 1.5 metre with suitable wooden plugs / gunny bags and pumping / bailing out effluent and taking out / removing the accumulated sludge soil sewage / any other foreign / foul materials etc (solid / semisolid) from the septic tanks / manholes, complete and cleaning the septic tank / manholes with fresh water by mechanically / manually including taking out the blocking arrangements of inlet and making the system functional and disposal off out side of MoD land all as specified and directed.
92Note :- (i) Contractor/His representative collect the complaints/docket at 0830 Hrs from complain cell daily.(ii) Sewage/ Misc B/R complaints rectified within 24 Hrs. If contractor fail to rectify the complaints within 24 Hrs, penalty of Rs 500/- fine charged per complaints per day. (iii) All staff take proper hygiene precaution and instruction followed as per order given by Stn HQ Instruction time to time. (iv) All T&P and safety eqpt provided to workers by the contractor, if he failed in any will be fined Rs 250/- per man per day.(v) Due to Security reason Supervisor reqd in each site if the contractor fail it to maintain, penalty charged 500/- per day per site. (vi) Contractor/His representative must follow proper guideline of CPHEEO (Central Public Health & Environmental Engineering Organisation.
93Removal of blockage and cleaning of sewage lines of 150 mm bore sewage line by roding from manholes to manholes or manholes to cleaning eyes, with suitable wooden plugs / gunny bags and cleaning the same by rodding and removing the sludge alongwith brick bats / stones / broken bottles / any other foreign materials etc complete and cleaning the sewage line with fresh water by mannually / mechanically as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional and disposal off out side of MoD land all as specified and directed.
94Note :- (i) Contractor/His representative collect the complaints/docket at 0830 Hrs from complain cell daily.(ii) Sewage/ Misc B/R complaints rectified within 24 Hrs. If contractor fail to rectify the complaints within 24 Hrs, penalty of Rs 500/- fine charged per complaints per day. (iii) All staff take proper hygiene precaution and instruction followed as per order given by Stn HQ Instruction time to time. (iv) All T&P and safety eqpt provided to workers by the contractor, if he failed in any will be fined Rs 250/- per man per day.(v) Due to Security reason Supervisor reqd in each site if the contractor fail it to maintain, penalty charged 500/- per day per site. (vi) Contractor/His representative must follow proper guideline of CPHEEO (Central Public Health & Environmental Engineering Organisation.
95Deployment of refrigerent mechanic for Attending the Complaints of Split AC / Window AC for rectification of minor defects etc at any location of Cantt area, complete all as specified and directed.
96Dismantling of burnt contactor and Supply & fix power contactor 1ph suitbale for Tower AC/ split AC/ Window AC of any make , model and capacity, complete all as specified and directed.
97Dismantling of defective outdoor stand of split AC and supply & fixing outdoor stand of split AC at suitable location, complete all as specified and directed.
98Dismantling of burnt capacitor and Supply & Fix capacitor of capacity 36 Mfd in plastic/ metal container, complete all as specified and directed.
99Dismantling of burnt capacitor and Supply & Fix capacitor of capacity 50+5Mfd in plastic/ metal container, complete all as specified and directed.
100Dismantling of burnt capacitor and Supply & Fix capacitor of capacity 45 Mfd in plastic/ metal container , complete all as specified and directed.
101Dismantling of burnt Indoor unit Censor and Supply & Fix Censor (in each set) of Indoor unit Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities , complete all as specified and directed.
102Dismantling of burnt Outdoor unit Censor and Supply & Fix Censor (in each set) of Outdoor unit Split AC Inverter type (Cooling / Hot and cold type) of any make and model for 1.5 TR / 2 TR capacities , complete all as specified and directed.
103Dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC , complete all as specified and directed.
104Dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR indoor unit of split AC Inverter type (cooling only / hot & cold type) , complete all as specified and directed.
105Dismantling of burnt Swing motor and Supply & Fix Swing motor for 1.5 TR / 2 TR window AC , complete all as specified and directed.
106Dismantling of defected brass suction valve and Supply & fix brass suction valve size 3/8\\" , complete all as specified and directed.
107Dismantling of defected Discharge valve and Supply & fix Discharge valve size 1/2\\" , complete all as specified and directed.
108Dismantling of defected charging valve and Supply & fix charging valve size 1/4\\", complete all as specified and directed.
109Dismantling of defected flare nuts and Supply & fix flare nuts size 3/8\\", complete all as specified and directed.
110Dismantling of defected flare nuts and Supply & fix flare nuts size 1/4\\", complete all as specified and directed.
111Dismantling of defected flare nuts and Supply & fix flare nuts size 1/2\\" , complete all as specified and directed.
112Dismantling of defected flare nuts and Supply & fix flare nuts size 5/8\\" , complete all as specified and directed.
113Dismantling of defected copper gas filter and Supply & fix copper Gas filter for AC 1.5 TR / 2 TR capacity , complete all as specified and directed.
114Dismantling of burnt connector and Supply & fix connector suitbale for Tower AC/ split AC/ Window AC of any make , model and capacity , complete all as specified and directed.
115M&L in repair PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm) , complete all as specified and directed.
116S&F in repairs Mettalic Plugs ( top) of AC box 20A, specified make , 2P+E and connecting complete all as specified and directed.
117S&F in repairs copper capillary of size 0.60 mm complete all as specified and directed
118S&F in repair 32Amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 32 Amp as required.complete all as specified and directed.
119Supply only of puff insulation of size1/2\\" suitable for 1.5 TR/2.0 TR Ac, complete all as per specified and directed.
120Supply only of puff insulation of size1/4\\" suitable for 1.5 TR/2.0 TR Ac, complete all as per specified and directed.
121Supply only of puff insulation of size5/8\\" suitable for 1.5 TR/2.0 TR Ac, complete all as per specified and directed.
122Supply and fix in repair PVC pipe nylon embraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall , complete all as per specified and directed.
123Supply and fix in repair of copper tubing 3/8\\"dia with puff insulation , complete all as per specified and directed.
124Supply and fix in repair of copper tubing 1/2\\" dia with puff insulation , complete all as per specified and directed.
125Supply and fix in repair of copper tubing 1/4\\" dia with puff insulation , complete all as per specified and directed.
126Supply and fix remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
127Supply and fix remote hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
128Supply and fix remote hand set of Inverter type Split air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed.
129Supply and fix in repair Air sensor for temperature control for 1.5 TR/ 2.0 TR Split AC/ Tower AC/ Window AC complete all as specified and directed.
130Supply and fix PVC fan blade with gun metal bush of blower , Screw complete as per complete all as directed by EIC
131Supply and fix PVC blower for window A.C. as per sample complete all as specified and directed Please Enable Macros to View BoQ information
132Supply and fix PVC blower for window A.C. as per sample complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57986893
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.99 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Internal/External Electrification System, B/R Works And Other Connected Works Such As Fire Fighting Eqpt Water Supply Pipe Line Submersible Pump At Water Supply Installation At Prabudh Vihar (Pcda) Devikhera Under Ge E/M Lucknow
Basic Detail
Tender No GE/EM/LKO/HOSP/T-26 OF 2026-27
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 12 Oct 2026
Submission Date 02 Nov 2026
Open Date 04 Nov 2026
Finance
Tender Value 48.99 Lakhs
Tender Fee 500
EMD 97980
Exemption Available
Document List
9652b4b0-b0b4-4263-b8d1-bdc6344bb150.html
BOQ_889841.xls
Tender26.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

9652b4b0-b0b4-4263-b8d1-bdc6344bb150.html

xls

BOQ_889841.xls

pdf

Tender26.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender