Tender For Renovation Work Of Conference Hall With Room (G. Floor), Renovation Work Of Dgp Conference Hall And Installation Of Lift At Phq, Dhurwa In The District Of Ranchi.
Tender Value
2.09 Crore
Estimated cost
Bid Submission
27 Oct 2026
10 days left
EMD
4.19 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Work Of Conference Hall With Room (G. Floor), Renovation Work Of Dgp Conference Hall And Installation Of Lift At Phq, Dhurwa In The District Of Ranchi.
BOQ
| Sl. No. | Item Description |
| 1 | Section-I Civil Work (DGP Conference Hall) |
| 2 | 5.7.3Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 3 | 5.7.6Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 4 | 5.10.7Disrnantling old plaster and pointing in cement or lime and raking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as perdirection of E/|. |
| 5 | 5.8.9Extra for cleaning the old surface by scrapping the entire old white wash or colour wash rncluding cost of scaffolding all complete as per direction of E/I. |
| 6 | 5.8.21Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 7 | 5.8.41Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 8 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 9 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.11:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | 5.10.4Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 12 | 11.41 A/D.S.RProviding and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.2Glazed vitrified floor tiles polished finish of size 11.41A.2.5Size of Tile 1200 x 1200 mm |
| 13 | 5.10.2Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 14 | DSR 9.147AProviding and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 15 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 16 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 17 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 18 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 19 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 20 | 9.147.A4Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 21 | 9.147.A4.1Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 meter). |
| 22 | DSR/25.2Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels including: |
| 23 | DSR 11.56.1Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 24 | DSR/8.3Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 25 | DSR/12.45Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, |
| 26 | shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 27 | DSR/12.45.312.5 mm thick tapered edge gypsum moisture resistant board. |
| 28 | DSR/13.44Finishing walls with water proofing cement paint of required shade : |
| 29 | DSR/13.44.1New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 30 | DSR/14.72Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 31 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 32 | Coarse sand (10 Km) |
| 33 | Stone Chips (12 km) |
| 34 | Cement (3 km) |
| 35 | Electrical Installation Work |
| 36 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Anchor/Nitcab/Paraflex/V-GUARD (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG/Paraflex (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB/Anchor/ Great white (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / Legrand(Allazy)/L&T(enGem/ABB(TIVISHA) (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCBDB:Havell's/L&T/Legrand/Schneider/C&S/Anchor (6)XLPE/PVC aramoured cable:-Havell's/Polycab/KEI/Paraflex (7) LED FTTING FIXTURE -: Havells/Crompton/Philips/Panasonic/Jaquar/Doreka (Model/as per E/I ) |
| 37 | (8) CEILING / WALL / EXHAUST FAN -: Havells /Polar / Usha/Crompton (Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Crompton/RR ISPAT/Valmont/Transrail (10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN/HITACHI (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C.P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Eicher/Kirloskar/Mahindra |
| 38 | 1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 39 | 1.3.3Group C |
| 40 | 1.5Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 41 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 42 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 43 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 44 | 1.7.124x16 sq mm+2x6 sq mm earth wire |
| 45 | M-44910 q mm ISI Marked, FR L.S PVC insulated, single core copper conductorcable. |
| 46 | M-45125 sq mm ISI Marked, FR I.S PVC insulated, Single core copperconductor cable. |
| 47 | 1.21S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 48 | 1.21.332mm |
| 49 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 50 | 1.24.15/6 amps, one way switch |
| 51 | 1.24.45/6 amps, 3 pin socket outlet |
| 52 | M-1493Supply of Modular type AC starter switch for single phase 230 V /50 Hz of capacity 20/25 amp |
| 53 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 54 | 1.27.36 module(78mm x 205mm x 50mm) |
| 55 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required. |
| 56 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 57 | 1.37S/F Electronic musical Call bell :-Supplying and fixing electronic music call bell suitable for DC/AC single phase,230 volt, complete as required. |
| 58 | 1.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 59 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 60 | 2.9.44 way (4+12),Double door, Horizontal type |
| 61 | 2.9.56 way (4+18),Double door, Horizontal type |
| 62 | 2.11S/F 'B' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 63 | 2.11.16/32 amps,single pole, \\"B\\" SERIES |
| 64 | 2.12S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 65 | 2.12.16/32 amps,single pole, \\"C\\" SERIES |
| 66 | 2.12.1050/63 amps, TPN |
| 67 | 2.15S/F four pole MCB isoletor:-Supplying and fixing following rating four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commisioning etc as required. |
| 68 | 2.15.4125 amps |
| 69 | 3.6Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke) |
| 70 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 71 | M - 775Providing of 12'' (300 mm) Metal exhaust fan of make bajaj/havells/usha/crompton |
| 72 | M - 777Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 73 | M-15052 x 5W LED outdoor UP-DOWN light with IP:65 protection, die castaluminium housing |
| 74 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 75 | 9.3.418/20 W LED Round Down Light of make bajaj/havells/crompton/C&S /Jaquar |
| 76 | 9.3.112'x2' LED Panel Light of make bajaj/havells/crompton/C&S /Jaquar |
| 77 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 78 | 9.5.110/12 W LED Batten of make bajaj/havells/crompton/C&S/ Jaquar |
| 79 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S/ Jaquar |
| 80 | AC INSTALLATION |
| 81 | M -918Supply of Category \\"A\\" 2.0 Tr capacity Hi-Wall Split AC Unit of BEE Star Rating 5 Star, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising along with original company make stand to fix outdoor unit by suitable size of fasteners, copper pipes up to any length, insulating materials, heavy duty PVC drain pipe. Each drain pipe should be connected with building rain water drain pipe (Make:- Hilty/Fischer) etc as required.Make: Hitachi / Mitsubishi / Daikin / Carrier/Voltas. |
| 82 | M - 1622Supply, fitting, fixing of wall mount 5 KVA capacity of Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connecting 3 Mtr 3 core 2.5 Sq. mm Flexible Copper cable ( indoor unit to Stabilizer) Make- V-Guard/Totaline/Sen & Pandit. |
| 83 | M -1625Out door stand for 2.0 Tr Split AC |
| 84 | M -1617Copper Tube of size 1/4\\" for Split AC unit 1/1.5/2/3 Tr Capacity including nitride rubber insulation |
| 85 | M -1619Copper Tube of size 3/8\\" for Split AC unit 1/1.5/2/3 Tr Capacity including nitride rubber insulation |
| 86 | M -1623Drain pipe |
| 87 | MAIN PANEL |
| 88 | Design manufacture, supply installation, testing and commissioning of WEATHER PROOF DOUBLE DOOR with rubber gasket 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel. |
| 89 | Part-A |
| 90 | LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following: |
| 91 | INCOMING |
| 92 | 2.4.4160 amps, 35 KA Adjustable thermal seting |
| 93 | 2.5.1100 amps BUSBAR |
| 94 | 2.5.2200 amps BUSBAR |
| 95 | 2.7.263 amps, 4 pole CHANGEOVER |
| 96 | OUTGOING |
| 97 | 2.4.3125 amps, 16 KA Adjustable thermal seting MCCB |
| 98 | 2.12.86/32 amps,TPN |
| 99 | 2.12.1050/63 amps, TPN |
| 100 | 2.12.56/32 amps ,DP |
| 101 | OTHER ACCESSOSRIES |
| 102 | M- 873 ADIGITAL VOLT METER 500V(3phase class 0.5) |
| 103 | M- 873 BDIGITAL A METER 500V(3phase class 0.5) |
| 104 | M- 445COPPER WIRE 1.5MM |
| 105 | M- 448COPPER WIRE 6MM |
| 106 | M -450COPPER WIRE 16MM |
| 107 | M -451COPPER WIRE 25MM |
| 108 | M- 1455LED INDICATOR LAMP R/Y/B/G |
| 109 | M- 1452C.T COIL OF CT ratio 500/5 IS2705 part -3 |
| 110 | PART-B |
| 111 | Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, selector switches, CT's, PT's, etc.Space for single phase energy metre. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel.(50% of part -A ) |
| 112 | Installation of Conference System with all accessories all complete as per specification and direction of E/I. |
| 113 | Installation of Audio Video Conference System all complete as per specification and direction of E/I. |
| 114 | Section-II Civil Work (G.F Conference hall) |
| 115 | 5.7.3Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 116 | 5.7.6Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 117 | 5.10.7Disrnantling old plaster and pointing in cement or lime and raking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as perdirection of E/|. |
| 118 | 5.8.9Extra for cleaning the old surface by scrapping the entire old white wash or colour wash rncluding cost of scaffolding all complete as per direction of E/I. |
| 119 | 5.8.21Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 120 | 5.8.41Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.) |
| 121 | 5.8.45Providing two coats of synthetic enamel paint of approved shade and made over steel surface including cleaning the surface thoroughly including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I |
| 122 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.11:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 123 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 124 | 5.10.4Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 125 | 11.41 A/D.S.RProviding and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.11.41A.2Glazed vitrified floor tiles polished finish of size 11.41A.2.5Size of Tile 1200 x 1200 mm |
| 126 | 5.10.2Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 127 | DSR 11.56.1Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 128 | DSR/8.3Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 129 | DSR/12.45Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, |
| 130 | shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 131 | DSR/12.45.312.5 mm thick tapered edge gypsum moisture resistant board. |
| 132 | DSR/13.44Finishing walls with water proofing cement paint of required shade : |
| 133 | DSR/13.44.1New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 134 | DSR 9.147AProviding and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 135 | After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. |
| 136 | Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. |
| 137 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: |
| 138 | (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 |
| 139 | (ii) Sites with structure height more than 20m for all wind speeds. |
| 140 | 9.147.A4Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 141 | 9.147.A4.1Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 meter). |
| 142 | 5.10.1Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 143 | 5.2.11Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge |
| 144 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 145 | Bricks (1K+7P=8 KM.) |
| 146 | Coarse sand (10 Km) |
| 147 | Stone Chips (12 km) |
| 148 | Cement (3 km) |
| 149 | Electrical Installation Work |
| 150 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Anchor/Nitcab/Paraflex/V-GUARD (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG/Paraflex (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB/Anchor/ Great white (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / Legrand(Allazy)/L&T(enGem/ABB(TIVISHA) (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCBDB:Havell's/L&T/Legrand/Schneider/C&S/Anchor (6)XLPE/PVC aramoured cable:-Havell's/Polycab/KEI/Paraflex (7) LED FTTING FIXTURE -: Havells/Crompton/Philips/Panasonic/Jaquar/Doreka (Model/as per E/I ) |
| 151 | (8) CEILING / WALL / EXHAUST FAN -: Havells /Polar / Usha/Crompton (Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Crompton/RR ISPAT/Valmont/Transrail (10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN/HITACHI (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C.P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Eicher/Kirloskar/Mahindra |
| 152 | 1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 153 | 1.3.3Group C |
| 154 | 1.5Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 155 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 156 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 157 | 1.7.104x6 sq mm+2x6 sq mm earth wire |
| 158 | 1.7.124x16 sq mm+2x6 sq mm earth wire |
| 159 | M-44910 q mm ISI Marked, FR L.S PVC insulated, single core copper conductorcable. |
| 160 | M-45125 sq mm ISI Marked, FR I.S PVC insulated, Single core copperconductor cable. |
| 161 | 1.21S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required . |
| 162 | 1.21.332mm |
| 163 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 164 | 1.24.15/6 amps, one way switch |
| 165 | 1.24.45/6 amps, 3 pin socket outlet |
| 166 | M-1493Supply of Modular type AC starter switch for single phase 230 V /50 Hz of capacity 20/25 amp |
| 167 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 168 | 1.27.36 module(78mm x 205mm x 50mm) |
| 169 | 1.32S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required. |
| 170 | 1.33S/F ceiling rose:-Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required. |
| 171 | 1.37S/F Electronic musical Call bell :-Supplying and fixing electronic music call bell suitable for DC/AC single phase,230 volt, complete as required. |
| 172 | 1.48ITC exhaust fan up to 450 mm, sweep:-Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required. |
| 173 | 2.9S/F T.P.MCB DB:-Supplying and fixing following way three pole and nutral,sheet,MCB distribution board,415 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 174 | 2.9.44 way (4+12),Double door, Horizontal type |
| 175 | 2.9.56 way (4+18),Double door, Horizontal type |
| 176 | 2.11S/F 'B' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 177 | 2.11.16/32 amps,single pole, \\"B\\" SERIES |
| 178 | 2.12S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 179 | 2.12.16/32 amps,single pole, \\"C\\" SERIES |
| 180 | 2.12.1050/63 amps, TPN |
| 181 | 2.15S/F four pole MCB isoletor:-Supplying and fixing following rating four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commisioning etc as required. |
| 182 | 2.15.4125 amps |
| 183 | 3.6Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke) |
| 184 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 185 | M - 775Providing of 12'' (300 mm) Metal exhaust fan of make bajaj/havells/usha/crompton |
| 186 | M - 777Providing of 16'' (400 mm) Wall fan of make bajaj/havells/usha/crompton |
| 187 | M-15052 x 5W LED outdoor UP-DOWN light with IP:65 protection, die castaluminium housing |
| 188 | 9.3SITC of following rating recess/ surface mounted LED round /square shape down light luminire with pressure dia cast housing for single phase supply voltage, Luminarie shall be confirmto IS:10322 part - 5/section -2 or IEC : 62722 with all neccessary accessories as required. |
| 189 | 9.3.418/20 W LED Round Down Light of make bajaj/havells/crompton/C&S /Jaquar |
| 190 | 9.3.112'x2' LED Panel Light of make bajaj/havells/crompton/C&S /Jaquar |
| 191 | 9.5SITC of following rating surface mounted LED tube light fitting suitable for 230 V 50 Hz, single phase supply etc .complete as required |
| 192 | 9.5.110/12 W LED Batten of make bajaj/havells/crompton/C&S/ Jaquar |
| 193 | 9.5.220/22 W LED Batten of make bajaj/havells/crompton/C&S/ Jaquar |
| 194 | AC INSTALLATION |
| 195 | M -918Supply of Category \\"A\\" 2.0 Tr capacity Hi-Wall Split AC Unit of BEE Star Rating 5 Star, with original company make out door structure including rigging of indoor out door units, pressure testing vacuumingising along with original company make stand to fix outdoor unit by suitable size of fasteners, copper pipes up to any length, insulating materials, heavy duty PVC drain pipe. Each drain pipe should be connected with building rain water drain pipe (Make:- Hilty/Fischer) etc as required.Make: Hitachi / Mitsubishi / Daikin / Carrier/Voltas. |
| 196 | M - 1622Supply, fitting, fixing of wall mount 5 KVA capacity of Automatic Voltage Stabilizer, voltage range 140V to 280V of copper wound Transformer along with suitable size of connecting 3 Mtr 3 core 2.5 Sq. mm Flexible Copper cable ( indoor unit to Stabilizer) Make- V-Guard/Totaline/Sen & Pandit. |
| 197 | M -1625Out door stand for 2.0 Tr Split AC |
| 198 | M -1617Copper Tube of size 1/4\\" for Split AC unit 1/1.5/2/3 Tr Capacity including nitride rubber insulation |
| 199 | M -1619Copper Tube of size 3/8\\" for Split AC unit 1/1.5/2/3 Tr Capacity including nitride rubber insulation |
| 200 | M -1623Drain pipe |
| 201 | MAIN PANEL |
| 202 | Design manufacture, supply installation, testing and commissioning of WEATHER PROOF DOUBLE DOOR with rubber gasket 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel. |
| 203 | Part-A |
| 204 | LT PANEL (NORMAL SUPPLY) :35 KA) -INCOMING (1- sets ) each with following: |
| 205 | INCOMING |
| 206 | 2.4.4160 amps, 35 KA Adjustable thermal seting |
| 207 | 2.5.1100 amps BUSBAR |
| 208 | 2.5.2200 amps BUSBAR |
| 209 | 2.7.263 amps, 4 pole CHANGEOVER |
| 210 | OUTGOING |
| 211 | 2.4.3125 amps, 16 KA Adjustable thermal seting MCCB |
| 212 | 2.12.86/32 amps,TPN |
| 213 | 2.12.1050/63 amps, TPN |
| 214 | 2.12.56/32 amps ,DP |
| 215 | OTHER ACCESSOSRIES |
| 216 | M- 873 ADIGITAL VOLT METER 500V(3phase class 0.5) |
| 217 | M- 873 BDIGITAL A METER 500V(3phase class 0.5) |
| 218 | M- 445COPPER WIRE 1.5MM |
| 219 | M- 448COPPER WIRE 6MM |
| 220 | M -450COPPER WIRE 16MM |
| 221 | M -451COPPER WIRE 25MM |
| 222 | M- 1455LED INDICATOR LAMP R/Y/B/G |
| 223 | M- 1452C.T COIL OF CT ratio 500/5 IS2705 part -3 |
| 224 | PART-B |
| 225 | Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proof complete with all inter connections small wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, selector switches, CT's, PT's, etc.Space for single phase energy metre. The panels shall be got fabricated only from panel builders having 7 tank process finishing system and CPRI approved certificate for similar LT Panel.(50% of part -A ) |
| 226 | Installation of Audio Video Conference System all complete as per specification and direction of E/I. |
| 227 | Section-III Civil Work (Lift Pit) |
| 228 | 5.7.3Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 229 | 5.7.3Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 230 | 5.10.7Disrnantling old plaster and pointing in cement or lime and raking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as perdirection of E/|. |
| 231 | 5.8.18Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 232 | 13.80 Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 233 | 5.3.11Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 234 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 235 | JSR 2021 page no.32 sl no 55 (ii)Providing & supplying Cico liquid / impermo water proofing compound in cement concrete or cement mortar @ 2% of cement quqntity by weight ( as specified) for water proofing, including all carraige and taxes . |
| 236 | DSR/13.45Finishing walls with textured exterior paint of required shade : 13.45.1New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. |
| 237 | DSR 11.56.1Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.8.13.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 238 | DSR 13.45.1Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 239 | 13.46Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 240 | Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I. |
| 241 | Coarse sand (10 Km) |
| 242 | Cement (3 km) |
| 243 | Steel (3 km) |
| 244 | Electrical Installation Work |
| 245 | Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Anchor/Nitcab/Paraflex/V-GUARD (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG/Paraflex (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB/Anchor/ Great white (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / Legrand(Allazy)/L&T(enGem/ABB(TIVISHA) (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCBDB:Havell's/L&T/Legrand/Schneider/C&S/Anchor (6)XLPE/PVC aramoured cable:-Havell's/Polycab/KEI/Paraflex (7) LED FTTING FIXTURE -: Havells/Crompton/Philips/Panasonic/Jaquar/Doreka (Model/as per E/I ) |
| 246 | (8) CEILING / WALL / EXHAUST FAN -: Havells /Polar / Usha/Crompton (Model/as per E/I) (9)OCTAGONAL POLE/High Mast-: Bajaj/Philips/Crompton/RR ISPAT/Valmont/Transrail (10) CENTRALISED AIR CONDITIONING-:VOLTAS/MITSHUBISHI/TOSHIBA/DAIKIN/HITACHI (11)ALL ELECTRICAL WIRING WORK SHOULD BE CONCEALED (12)CCTV CAMERA /DVR-:Panasonic/Hik vision/C.P Plus/Godrej (13)Monitor Camera -: Dell/Samsung/LG/Asus (14)Silent type D.G Set-:Kohler/Jakson/Sterling/Eicher/Kirloskar/Mahindra |
| 247 | 1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 248 | 1.3.1Group A |
| 249 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 250 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 251 | 1.7.114x10.0 sq mm+2x6.0 sq mm earth wire |
| 252 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 253 | 1.24.15/6 amps, one way switch |
| 254 | 1.24.45/6 amps, 3 pin socket outlet |
| 255 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 256 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 257 | 2.4S/F MCCB in cubical panel board:-Providing and fixing following rating and capacity four pole MCCB in existing panel borad,including drilling holes in cubical panel making connections etc as required. |
| 258 | 2.4.125/100 amps, 10 KA fixed thermal seting |
| 259 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 260 | 2.8.88 Way,Double door |
| 261 | 2.12S/F 'C' series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 262 | 2.12.16/32 amps,single pole, \\"C\\" SERIES |
| 263 | 2.12.1050/63 amps, TPN |
| 264 | 3.6Copper Earth plate electrode:-Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required.( with salt charcoal or coke) |
| 265 | 3.7S/L 8 SWG copper wire ground :-Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required. |
| 266 | Code no.Supply of PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1)g |
| 267 | 5.13Laying and fixing of one number PVC insuleted and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required.Up to35 sq.mm (clamped with 1 mm thick saddle) |
| 268 | M-74016 sq.mm. 4 core |
| 269 | 9.1 DSRSupplying and making end termination with brass commpression gland and aluminium lugs for following size of PVC insuleted and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 270 | 9.1.33 DSR 4 X 16 sq. mm (28mm) |
| 271 | M - 869Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton |
| 272 | PRODUCT :Gen2-Nova_ModularDETAILS : GeN2-Nova_MRL-1MPSCAPACITY (kgs) : 612 kg, 9 personsSPEED (mps) : 1RISE (m) : 6.8 mSTOPS : 3 Stops With (all opening on the same side)CONTROLLER TYPE : LVA/ACDDRIVE : VF Regenerative (Closed Loop)POWER SUPPLY : 400/415 Volts (3 Phase AC)OPERATION : Full collective operationCAR GROUP : One car (simplex)MACHINE : PM GearlessTRACTION MEDIA : Flat Coated Steel BeltCAR FINISH : • Rear Mid Panel = Stainless Steel #4(Hairline)• Rear Corner Panels = Stainless Steel #4(Hairline)• Side Mid Panels = Stainless Steel #4(Hairline)• Side Corner Panels = Stainless Steel #4(Hairline)• Front Panels = Stainless Steel #4(Hairline)FALSE CEILING TYPE Prime ceiling, Stainless Steel #4(Hairline)FALSE CEILING FINISH : Stainless Steel #4(Hairline)VENTILLATION : Cross flow fanHAND RAILS : Stainless Steel Mirror FinishHandrails on rear car panelsFLOORING : GRANITE provided by customer (20 mm recess by OTIS)CAR DOOR FINISH : Front Panels = Stainless Steel #4(Hairline)LANDING DOORS |
| 273 | FINISH:Stainless Steel #4(Hairline)FIRE RATED DOORS : Fire rating-120minsPIT DEPTH : 1350OVERHEAD 4200HOISTWAYDIMENSIONS (W x D –mm):2100 mm W x 1700 mm DCAR DIMENSIONS (W xD x H - mm):1200 mm W x 1300 mm D x 2300 mm HCAR & HOISTWAYDOOR TYPE:Central opening (CO) doorsDOOR OPENING (W x H- mm):800 mm W x 2100 mm HDOOR OPERATOR : DC Door OperatorCOP : Pan typeCAR POSITIONINDICATOR: Monochrome LCD-Blue Background & White fontHALL FIXTURES : O2000HALL FIXTURE FACEPLATE:SS HairlineHALL BUTTONARRANGEMENT:Hall Button with HPISTANDARD FEATURES : Anti-nuisance Car Call ProtectionIndependent Service (for Duplex only)Overload DeviceNudgingEmergency Firemen’s ServiceEmergency Car Light UnitInfrared Curtain Door ProtectionDoor Time ProtectionEmergency Alarm ButtonExtra Door Time of Lobby & ParkingDoor Open/Close ButtonManual Rescue OperationBelt Inspection DriveAuto Fan Cut OffOPTIONS INCLUDED : Automatic Rescue operation,Intercom,Audible Car Call Button, |
| 274 | MAKE:- OTIS/KONE/JOHNSON/TK OR EQUIVQLENT |
| 275 | Uninstallation of old Lift |
| 276 | Add 18% GST |
| 277 | Add 1% Lebour Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender