Tender For Repair / Maintenance Of Water Supply And Allied Works, Internal Wiring, Light Fittings, Dbs, Geysers, Ceiling Fan, Exhaust Fan, Street Lights, Perimeter Lights, Runway Lights, High Mast Lights, Dg Sets, Perimeter Ug Cable And Other Connect
Tender Overview
Project Description
Tender for Repair / Maintenance Of Water Supply And Allied Works, Internal Wiring, Light Fittings, Dbs, Geysers, Ceiling Fan, Exhaust Fan, Street Lights, Perimeter Lights, Runway Lights, High Mast Lights, Dg Sets, Perimeter Ug Cable And Other Connected Items At Alg Pasighat Under Ge(Af) Chabua
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Oct-2026 | BOQ Revision | BOQ | 03-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (if required), complete all as per specified and as directed by Engineer-in-Charge.Note: - (a) Cost of spares and accessories will be measured and paid seperatly under relevent items. (b) Cost for taking down and re-fixing of street lights shall be deemed to be included in the unit rate quoted.(c) Any other items or parts (other than listed in Sch A) required for smooth functioning of street lights/ Security lights on pole from junction box busbar to street light shall be provided by the contractor and rates for the same are deemed to be included in above item here in before nothing extra shall be paid on this account.(d) All the fitting of HPSV/ HVMV LED street light/ flood light will be cleaned once in a month or when required.The rates for which shall be deemed to be included in the unit rate quoted. |
| 2 | Supply and fix in repair LED driver suitable for 45 watt LED street light fitting complete all as specified and directed. |
| 3 | Supply and fix in repair LED driver suitable for 60 watt LED street light fitting complete all as specified and directed. |
| 4 | Supply and fix in repair LED driver suitable for 70 watt LED street light fitting complete all as specified and directed. |
| 5 | Supply and fix in repair LED driver suitable for 90 watt LED street light fitting complete all as specified and directed. |
| 6 | Supply and fix in repair LED driver suitable for 100 watt LED street light fitting complete all as specified and directed. |
| 7 | Taking down old unsv UG cable of size 16 sqmm x 4 cor complete all as specified and as directed at site. |
| 8 | Supply and laying in trenches or drawn through pipe or fixed on wall/poles, LT UG cable heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 16 sqmm x 4 core complet all as specified and as directed at site. |
| 9 | Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed. |
| 10 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 11 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 12 | Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. |
| 13 | M&L sub class B brick,well burn laid bridth-wise along the length the cable laid in trench over sand cushion,laid for ug cable protection complete all as specified and directed at site. |
| 14 | Supply and fixing steel tubes, galvanised, light grade, ISI marked 50 mm bore for protection of cable under floor, road and on wall complete. |
| 15 | Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreating with PCC 1:3:6 to match with the adjescent surfaces complete all as directed at site. |
| 16 | Supply and fix street light GI bracket,bend to 120 degree angle,made out of 40 mm bore,gI pipe,light grade (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts,bolts and washers etc and two coat of synthetic enameled paint over a coat of red oxide primer including taking down the old rusted one complete all as specified and directed. |
| 17 | S&F in repairs junction box 200 x 140 x95 mm in size , made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed on poles with flat aluminium clamps of size 20 x 3 mm, nuts,bolts,washers etc.& taking out of old unsv cable junction box complete all as specified and as directed.site. |
| 18 | Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension GI wire, one twin core cable flat or circular with size 6 sqmm x 2 core complete all as specified and directed at site. |
| 19 | All as per ser item no 18 here in before but size of cable 10 sqm x 2 core |
| 20 | S&F in replacement of LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 120 W capacity after taking down the old unserviceable one complete all as specified and directed . |
| 21 | S&F in replacement of LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 60 W capacity after taking down the old unserviceable one complete all as specified and directed . |
| 22 | S&F in replacement of LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 90 W capacity after taking down the old unserviceable one complete all as specified and directed |
| 23 | S&F in repair post top lantern/Gatelightst top luminaire LED type of 45 W of post top lantern with aluminium die-cast housing cum heat sink in IP-65 protection including all fixinging arrangement complete all as specified and as directed, |
| 24 | M&L for complete servicing of high mast light of any height including general checking, mechanical parts and electrical system and maintenance complete all as specified and as directed for the followings :- (a) Checking and repair of head frame of the high mast poles fitted with wire ropes and cables. (b) Checking and repair of gear box for seal leakage. (c) Checking and repair of lift cables for frayed strands (d) Testing and repairing of lowering device and fully operate to fully down position. (e) Repair and maintenance of any mechnical devices as required. (f) Checking and repairing of all electrcial devices. (g) Checking and repair of luminaires box, control gear and junction box nad tightened properly. (h) Checking and reparing of all screws and nuts properly. Please Enable Macros to View BoQ information |
| 25 | M&L for complete servicing of high mast light of any height including general checking, mechanical parts and electrical system and maintenance complete all as specified and as directed for the followings :- (a) Checking and repair of head frame of the high mast poles fitted with wire ropes and cables. (b) Checking and repair of gear box for seal leakage. (c) Checking and repair of lift cables for frayed strands (d) Testing and repairing of lowering device and fully operate to fully down position. (e) Repair and maintenance of any mechnical devices as required. (f) Checking and repairing of all electrcial devices. (g) Checking and repair of luminaires box, control gear and junction box nad tightened properly. (h) Checking and reparing of all screws and nuts properly. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.