Road Transport and Highways Government Departments Closing in 8 days TDR #57982458

Tender For Construction Of Rob At Kakati Gaon In Replacement Of Railway Lc Gate No. St-34 At Rly Km 104/7-8 On Raha K Ur Road Under Construction Of Robs On 50:50 Cost Sharing Basis (Balance Work)

Issued by Government Departments · Nagaon, Assam
Tender Value
35.69 Crore
Estimated cost
Bid Submission
06 Nov 2026
8 days left
EMD
71.39 Lakhs
Bank guarantee accepted
Document Fee
30000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagaon → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Rob At Kakati Gaon In Replacement Of Railway Lc Gate No. St-34 At Rly Km 104/7-8 On Raha K Ur Road Under Construction Of Robs On 50:50 Cost Sharing Basis (Balance Work)

BOQ

Name of Work:- Construction of ROB at Kakati Gaon in replacement of Railway LC Gate No. ST-34 at Rly KM 104/7-8 on Raha K ur Road under Construction of ROBs on 50:50 Cost Sharing Basis (Balance Work)
Sl. No. Item Description
1ROB (Span over Railway line) : Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means (I) without dewatering (i) Depth upto 3 m
2Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
3Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 (Pile diameter-1200 mm)
4Pile load test on single vertical pile in accordance with IS:2911(Part-IV).a). Initial load test.
5Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump
6Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. C. RCC Grade M30 Case II. Using Batching Plant, Transit Mixer and Concrete Pump
7Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
8Providing steel liner 8mm thick for steining of wells/pile including fabricating upto full length and setting out as per detailed drawing. (rate as per Assam PWD's approved rate)
9Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (a) Height upto 5m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
10Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
11Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (a) Height upto 5m. Case-II. With Batching Plant, Transit Mixer and Concrete Pump
12Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
13Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
14Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.
15Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45 (ii)for I-beam & Slab including launching of precast girders by launching truss upto 40m span (b) Height 5m to 10m.
16Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel Jindal panther steel/ Shyam steel or equivalent)
17Structural Steel Built up girder (BUG) Providing and launching steel truss of Structural steel BUG Super Structure including painting complete as per drawing and technical specifications under Section 1900 of MOST.
18Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified.
19Drainage Spouts complete as per drawing and Technical specification
20PVC Pipe 150mm dia, connected to drainage spout.
21Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
22Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface
23Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )(Including cost of testing of materials at site and laboratory as directed by the deptt.) I. With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification) A. with 60/70 or VG-30 grade bitumen (ii) for Grading II (13 mm nominal size)
24Mastic Asphalt Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
25Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specifications to be installed by the mnufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.
26Providing, fitting and fixing Hand railing including MS Plat Base Plat Pipe complete as per drawing and Technical Specification. Over crash barrier.
27Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (A) For Plain surface crash barrier.
28Viaduct Portion : Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means (I) without dewatering (i) Depth upto 3 m
29Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
30Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming toIS-9103-1999 (Pile diameter-1200 mm)
31Pile load test on single vertical pile in accordance with IS:2911(Part-IV).a). Routine load test (2 Nos of test).
32Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump for Approach & Suspended Slab Wall
33Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. C. RCC Grade M30 Case II. Using Batching Plant, Transit Mixer and Concrete Pump
34Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
35Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (a) Height upto 5m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
36Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
37Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (a) Height upto 5m. Case-II. With Batching Plant, Transit Mixer and Concrete Pump
38Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
39Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
40Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.
41Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45 (ii)for I-beam & Slab including launching of precast girders by launching truss upto 40m span (b) Height 5m to 10m.
42Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel Jindal panther steel/ Shyam steel or equivalent)
43Structural Steel Built up girder (BUG) Providing and launching steel truss of Structural steel BUG Super Structure including painting complete as per drawing and technical specifications under Section 1900 of MOST.
44High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications
45Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified.
46Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
47Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. A) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/SAIL/Esser Steel) Jindal panther steel/Shyam steel or equivalent.
48Drainage Spouts complete as per drawing and Technical specification
49PVC Pipe 150mm dia, connected to drainage spout.
50Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
51Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface
52Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )(Including cost of testing of materials at site and laboratory as directed by the deptt.) I. With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification) A. with 60/70 or VG-30 grade bitumen (ii) for Grading II (13 mm nominal size)
53Mastic Asphalt Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level andslope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
54Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specifications to be installed by the mnufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.
55Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (A) For Plain surface for Crash Barrier & Kerb.
56Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (B) RCC Railling
57RE Wall : Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. III. Earth work including excavation, backfilling, grading and compaction with selected backfill soil in layers in Reinforced Earth works as per Technical specification and drawings.
58Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. IV. Construction of PCC strips level footing (35cm x 15cm) in M-15 grade concrete complete as per technical specification and drawing.
59Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. I. 180 mm thick, M-35 grade RCC Facing elements of shape and size as per design and drawing with bearing pads, joint fillers, tie strips, fastener and all accessories and consumable complete.
60Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. II. Assembling, joining and laying of reinforcing elements. B. With Reinforcing elements of Synthetic Geogrids
61Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A. Granular material
62Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. V. Providing 600mm drainage bay behind RE wall with compacted granular material as per technical specification and drawing.
63Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. VI. Construction of crash barrier, parapet, coping beam with friction slab in M-30 grade concrete complete as per technical specification and drawing
64Sub Surface Drains with Perforated Pipe Construction of a narrow filter sub- surface drain consisting of porous or perforated pipe laid in narrow trench surrounded by a geotextile filter fabric, with a minimum of 450 mm overlap of fabric and installed as per clause 702.3 and 309.3.5 including excavation and backfilling .
65ROAD APPROACHES : Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202. I. By Manual Means. a. Bituminous courses
66Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202. I. By Manual Means. b. Granular courses
67Dismantling of CI water pipe line Dismantling of CI water pipe line 600 mm dia including disposal with all lifts and lead upto 1000 m and stacking of serviceable material and unserviceable material separately under supervision of concerned department as per Technical Specification Clause 202.
68Embankment Construction with material obtained from Borrow pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto ead upto 1000 m as per Technical Specification Clause 301.5. (i) From Govt land
69Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (ii) From Govt land
70Scarifying Existing Granular Surface Scarifying existing granular surface to a depth of 50mm and disposal of scarified material with a lift upto 3.0m and lead upto 1000m as per Technical specification Clause 301.4
71Compacting Original Ground (i) Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
72Granular Sub-Base with Coarse Graded Material ( Table:- 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) for grading-II material
73Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
74Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
75Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface
76Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. A. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (19mm nominal size)
77Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (13mm nominal size)
78SERVICE ROAD : Embankment Construction with material obtained from Borrow pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto ead upto 1000 m as per Technical Specification Clause 301.5. (i) From Govt land
79Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (ii) From Govt land
80Granular Sub-Base with Coarse Graded Material ( Table:- 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) for grading-II material
81Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
82Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
83Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface
84Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. A. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (19mm nominal size)
85Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (13mm nominal size)
86Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade , sloped towards the kerb, kerb stone with channel laid with kerb laying machine,foundation concrete manually all complete as per clause 408.) B. Using Concrete Batching and Mixing Plant
87RCC DRAIN : Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means I) without dewatering (i) Depth upto 3 m
88Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
89Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump
90Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in Sub Structure complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
91TRAFFIC SIGN : Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (i) 900mm equilateral triangle
92Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (ii) 600mm equilateral triangle
93Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (iii) 600mm circular
94Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. iv) 800mm x 600mm rectangular
95Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. v) 600mm x 450mm rectangular
96Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. vi) 600mm x 600mm square
97Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. vii) 900mm side octagon
98Direction and place identification sign upto 0.9sqm size board. Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
99Direction and place identification sign more than 0.9sqm Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
100Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work. Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
101Road Delineators Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming to IRC-79 and the drawings.
102Road Markers/Road Stud with Lense Reflector Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973
103Lighting on Bridges (Providing and fixing lighting on bridges, mounted on steel hollow circular poles of standard specifications, 5 m high fixed on parapets with cement concrete, 20 m apart and fitted with sodium vapour lamp) (cement concrete to be measured and paid separately) For fixing in foothpath
104Lighting on Bridge (Providing and fixing lighting on bridges, mounted on steel hollow circular poles of standard specifications, 5m high fixed on parapets with cement concrete, 20m apart and fitted with soudium vapour lamp)
105RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflectiveband of desired shade etc. complete as per design and as directed. (a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
106Protective Work (RCC Retaining Wall): Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means (I) without dewatering (i) Depth upto 3 m
107Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
108Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (a) Height upto 5m Case-II. With Batching Plant, Transit Mixer and Concrete Pump
109Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
110Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
111Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
112Protective Work (Pitching): Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. (I) Stone/Boulder
113Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302.
114Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 (I) Random rubble masonry in case of stone pitching laid with cement mortar (1:5)
115Excavation in Hard Rock (blasting prohibited) Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 200 metres, trimming bottom and side slopes in accordance withrequirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5. B. Mechanical Means
116Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. II. P.C.C grade M 15. Nominal mix (1:2.5:5)
117Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
118Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
119STRENGTHENING OF EXISTING ROAD : Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity
120Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC,and compacting with vibratory roller to achieve the desired density,complete as per cl. 401 (ii) for Grading II Material
121Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sb-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant ) By Mechanical Means with 1 km lead. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57982458
AUTHORITY Government Departments
TENDER VALUE 35.69 Crore
LAST DATE 06-11-2026
Authority
Authority Name Public Works Roads Department
Work Description Tender for Construction Of Rob At Kakati Gaon In Replacement Of Railway Lc Gate No. St-34 At Rly Km 104/7-8 On Raha K Ur Road Under Construction Of Robs On 50:50 Cost Sharing Basis (Balance Work)
Basic Detail
Tender No ROB/ST-34/ASSAM/RAHA/BALANCE WORK
Bidding Type Tender
Location
City Nagaon
State Assam
Key Dates
Publish Date 12 Oct 2026
Submission Date 06 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 35.69 Crore
Tender Fee 30000
EMD 71.39 Lakhs
Exemption Available
Document List
BOQ_85360.xls
downloads.htm.crdownload
edf9fcc9-1d3e-428d-be2c-9f7deb9406b5.html
FOB.pdf
SBDST34RahaBalancework.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_85360.xls

htm

downloads.htm.crdownload

html

edf9fcc9-1d3e-428d-be2c-9f7deb9406b5.html

pdf

FOB.pdf

pdf

SBDST34RahaBalancework.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender