Tender For Maintenance Of Perimeter/ External Lightning System In Rakhmuthi Mil Stn And Its Outstations Under Ge (S) Akhnoor.
Tender Overview
Project Description
Tender for Maintenance Of Perimeter/ External Lightning System In Rakhmuthi Mil Stn And Its Outstations Under Ge (S) Akhnoor.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing in replacement with new LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specifeid and directed. |
| 2 | Supply and fixing in replacement with new LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specifeid and directed. |
| 3 | Supply and fixing in replacement with new LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specifeid and directed. |
| 4 | Supply and fixing in replacement with new LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specifeid and directed. |
| 5 | Supply and fixing in replacement with new LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specifeid and directed. |
| 6 | Supply and fixing in replacement with new LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specifeid and directed. |
| 7 | Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25cm thick, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point , complete all as specified and as directed by Engineer-in-Charge. |
| 10 | M&L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. |
| 11 | M&L for sub class 'B' bricks, modular size, brick covering laid dry, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and as directed. |
| 12 | Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 16 Sqmm 4 core, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-Charge. |
| 13 | Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 25 Sqmm 4 core, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-Charge. |
| 14 | Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 50 Sqmm 3.5 core, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 15 | Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of size 50 Sqmm 3.5 core, including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender