Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57980226

Tender For Repair / Maintenance Of E/M Installations Under Ge (Af) Marathahalli Bangalore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
46.99 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
18 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of E/M Installations Under Ge (Af) Marathahalli Bangalore

BOQ

Name of Work:- REPAIR / MAINT OF E/M INSTALLATIONS UNDER GE (AF) MARATHAHALLI BANGALORE
Sl. No. Item Description
1Taking down GI/acrylic sign board of any type any size from existing locations near sub station buildingss complete all as directed by EIC .Note : Demolition of pcc supports/base and earth work will me measured and paid under respective item .
2Supply fabricating and fixing steel board stand made of 50 mm dia stainless steel heavy duty pipe of SS 304 grade ,suitable for outdoor purpose as per site requirement for fixing aluminium composite panel of various sizes of duly lettered and emblen ,fixed with nuts ,bolts of screw or any other arrangement ,along with frame of 20 mm dia SS pipe complete all as directed by EIC .Note :Necessary excavation and earthwork ,PCCMfor embedding pipes ,20 mm dia SS pipe for frame and ACP sheet will be measured and paid separately under respective items .
3Supply,fabricating and steel board frames ,posts and connecting pipes made of 20 mm dia stainless heavy duty pipe SS 304 grade suitable for outdoor purpose boards ,as per site requirement for fixing aluminium composite panel of various sizes ,fixed with nuts bolts of screw or any other arrangement complete all as directed by Engineer in Charge .Note :ACP Sheet will be measured and paid for separately under respective items .
4Supply and fix ACP sign board sheets of not less than 4 mm (2 mm sheets sticked back to back ) of various sizes ,including writing details of installations/machinery bith sides vinyl pasting on radium sticker with self glowing letters ,emblems along with lamination on both sides as perd irections of EIC
5Material and labour for writing letters of size upto 2 inch height ,with exterior grade enamel water proof paint on panels/feeder fillar boxes etc including representing incoming and outgoing connections complete all as specified and directed by Engineer in charge .
6Material and labour for writing letters of size upto 1.5 inch height ,with exterior grade enamel water proof paint on panels/feeder fillar boxes etc including representing incoming and outgoing connections complete all as specified and directed by Engineer in charge .
7Painting of details with Trf Capacity ,Sr No,Model No .Manfacturing Year , on the plinth of transformer with the direction of Engineer in charge complete all as specified and as directed
8Taking down old board and S& F Display board (Earth pit marker) made out of 25 mm angular frame with 45 cm height one side welded with 2mm thick MS sheet, frame work of size 15cmx15cm including excavation , PCC foundation and duly painted with redoxide & two coats black enamel paint with following letter display with white paint earth pit marker.a) Earthing pit No:- b) Earthing resistance:- c) E-N volt:- d) Check done on:- e) Check due On:-
9Supply Shock treatment chart as per IE rules ,size should not be less than 4 feet x 3 feet ,printing on PVC foam board complete all as specified and as directed with direction of EIC
10Supply Electrical safety rules as per IE norms,size should not be less than 4 feet x 3 feet ,printing on PVC foam boardc omplete all as specfied and as directed with direction of Engineer in charge .
11Supply operational safety gum boots of different size as per complete all as specified and as directed with direction of Engineer in charge .
12Supply operational safety torch light of 1500 W with zoom in/out feature complete all as specified and as directed directed by Engineer in charge
13Supply raincoats of different size as per quantity directed by Engineer incharge complete all as specified and as directed
14Supply and installation of the following fire safety accessories :Metal board of size ( 4 feet x 3 feet x 2 mm thickness ) mounted on angle of (6 feet x 6 feet , x 3 mm thickness ) with slope of gi sheet on both sides with size (4 feet x 1feet x 2mm thickness ) alongwith 3 Fire buckets of 9 litres capacity ,and fire beater on both sides ,with painting of two coat with red colour ,marked fire on one side and with related accessories etc complete all as specified and as directed with direction of EIC
15Taking down old Material and labour for Mild steel plates, plain or chequered, 5mm thick or over in thickness including cut to shape and required size to match the existing trench available at pump house/ power house/ open wells sizes complete.
16Supply and fixing singnage boards (Single Line diagram of HT /LT/Watersupply pipelines ) at different locations of any size as per site requirement. comuterised Letters/symbols/diagrams must be printed on 5mm thick self illuminated opaque PVC foam board of diffrent sizes including all fixing arrangement complete all as specified and as directed by Engr-in-Charge. Note : The board shall be fixed on wall with suitable chromium plated screws including washers, the letter size shall be not less than 40mm with approved colour.
17Demolition of existing wall in the pump house and removing material out of the premises with the direction of Engineer in charge complete all as specified and as directed .
18Taking down old UNSV panels from the pump house/power house and shifting to new location with disconnection the cables and to be reconnected in new locations if required with direction of Engineer inc charge complete all as specified and as directed .
19Supply stationary items Log book /Log sheet/ 400 pageswith specified format in A3 complete all as specified and directed with the direction of Engineer in charge
20M&L for Cutting or uprooting grass on old mud phuska including cutting the bushes, plants/ trees (less than 5 inch gridth) situated surroundings of water sumps/ OH tanks and removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster complete all as directed by Engg-in-Charge
21Excavation in trenches in soft /loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete.
22Excavating in trenches exceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
23Returning filling including spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick complete all as specified.
24Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified.
25Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
26Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
27M & L for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
28All as per Srl item No 27 here in above but GI pipe of size 80mm bore
29Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
30Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 240 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: Havells/ Polycab/Grandlay)
31All as per Srl item No 30 here in above but size of cable 16 Sqmm 4 core
32All as per Srl item No 30 here in above but size of cable 10 Sqmm 4 core
33All as per Srl item No 30 here in above but size of cable 95 Sqmm 3.5 core
34All as per Srl item No 30 here in above but size of cable 120 Sqmm 3.5 core
35All as per Srl item No 30 here in above but size of cable 50 Sqmm 3.5 core
36Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure.
37M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
38M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of the LT poles including form work complete all as specified
39Supply and fixing of Endura Citylite Platinum, 45 W LED Street Light fittingpressure die cast aluminium housing, heat resistance toughened glass, IP-66 protection in replacement of old UNSV 70W HPSV light fittings complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells)
40Taking down unsv 250 Amps MCCB and Supply & Fix MCCB TPN 415 Volts 250 Amps rating with breaking capacity of 35 kA with adjustable thermal & magnetic release complete with making all connections as per site requirement as specified and directed. (Make : Havells / L&T/ Legrand)
41All as per ser item no.35 here-in-before but MCCB TPN 415 Volts 100 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand)
42All as per ser item no.35 here-in-before but MCCB TPN 415 Volts 63 Amps, 25 kA complete with making all connections as specified and directed. (Make : Havells / L&T/ Legrand)
43Supply and fix Notice Board of wooden/UPVC material with Galss sliding door ,size should not be less than 4 feet x 3 feet with escalated sheet and also with locking arrangement complete all as specified and as directed with direction of Engineer in Charge .
44Supply water testing chlorine kit along with TDS meter complete all as specified and directed with direction of Engineer in Charge .
45Supply Plumbing tool Kit containing 10 inch water pump plier ,10 inch pipe wrench ,8 inch adjustable wrench,also with socket wrench set of different sizes ,allen key ,hammer.,screw driver,axe saw,Spanner of different sizes all within tool kit bag complete all as specified and as directed with direction of Engineer in charge .
46Taking down unserviceable RO Dosing Pump from position, material and labour with all fittings & fixtures, electrical connections for fixing the new Dosing Pump checking for leakages complete all as specified and as directed with direction of Engineer in Charge .
47Supply 2 HP automatic ,single phase 220 V submersible pump with discharge size 2 inch complete all as specified and as directed with direction of Engineer in Charge .
48Supply 23.6 Feet Aluminium folding telescopic ladder with 2 triangle support with EN131 certified with 2 year warranty ,weight capacity 150 Kg complete all as specified and as directed .
49Taking down meagger,EM tool equipemts for callibration and to change minor items copper wires,batteries if required complete all as specified and as directed by Engineer in Charge .
50M & L for cleaning and preparation of old painted surfaces of LT pannels and spray painting to pannel complete with two coats of synthetic enamel paint all as directed.
51Supply organization chart ,not less than size 4 ffet x 3 feet,with boundary bidding ,with PVC foam material ,complete all as specified and as directed with direction of Engineerin in charge .
52Disconnection & taking down the unserviceable GI bracket of size 50mm dia from the pole / building and M&L for street light bracket made out of 40 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles complete, including preparation of steel and iron surface and applying two coats of aluminium paint, first quality, over a coat of primer, etc complete, all as specified and as directed.Make of GI Pipe:- Jindal / Zenith / Prakash.Make of paint:- Asian / Berger / Jenson & Nicholson.
53Taking down old unserviceable earth pit and M/L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth strip 32 x 6 mm dia by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in RCC (1:2:4) Type B-1using 20mm crushed stone aggregate with 8 CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed by Engr-in-Charge. Note:- (i) GI earth lead beyond 7.5M shall be measured and paid separately. (ii) The rate include measuring earth resistance (iii)Weather coating paint will be done over chamber and inclusive in the above rate quoted .
54Taking down old earth pit and M/L for earthing complete with Copper earth plate electrode 600 X 600 X 3. 15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to copper earth strip 20 x 3 mm thick by means of with brazing at joints all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed . Notes:- (i) copper strip beyond 7.5 M shall be measured and paid separately under relevant items of this schedule.(iii)Weather coating paint will be done over chamber and inclusive in the above rate quoted .
55,Supply ,Fixing,installation and testing of industrial exhaust fan ,axial flow ,1 HP 6000 Cfm/Hr ,Fan size 36 inch complete all as specified and as directed .Note : louvers , nut bolts ,grating,and making hole with good surface finish complete all as specified and as directed .
56Supply Long handle umbrella 47 inch auto opening mechanism ,foldable handle ,silver lining complete all as specifed and as directed
57Supply A type ladder 5 feet ,with locking mechanism ,slip resistant steps ,mamimum loading capacity 150 Kg complete all as specified and as directed
58,Supply A type ladder 30 feet ,with locking mechanism ,slip resistant steps ,mamimum loading capacity 150 Kg complete all as specified and as directed
59Supply Air blower machine BOSCH GB_82-270 ,820W motor,4.5 m3/min,16000 rpm airflow.lightweight 2.25 kg ,dust cleaner ,multiple nozzles complete all as specified and as directed .Make :Bosch Please Enable Macros to View BoQ information
60Supply Air blower machine BOSCH GB_82-270 ,820W motor,4.5 m3/min,16000 rpm airflow.lightweight 2.25 kg ,dust cleaner ,multiple nozzles complete all as specified and as directed .Make :Bosch Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57980226
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.99 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of E/M Installations Under Ge (Af) Marathahalli Bangalore
Basic Detail
Tender No GE (AF) MARATHAHALLI / 8885 / E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 10 Oct 2026
Submission Date 31 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 46.99 Lakhs
Tender Fee 500
EMD 94000
Exemption Available
Document List
6757c9df-9259-47bb-b99d-5d7d32ec96ba.html
BOQ_889645.xls
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

6757c9df-9259-47bb-b99d-5d7d32ec96ba.html

xls

BOQ_889645.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders