Tender For Maint/ Repair/ Replacement Of External Electric Supply Installations Transformers, Two/ Four Pole Structure, Vcbs, Ht Panels, Ht/ Lt Cable, Ht God Switches Including Preventive Maintenance And Allied Work At Naval Station Porbandar, Repair
Tender Overview
Project Description
Tender for Maint/ Repair/ Replacement Of External Electric Supply Installations Transformers, Two/ Four Pole Structure, Vcbs, Ht Panels, Ht/ Lt Cable, Ht God Switches Including Preventive Maintenance And Allied Work At Naval Station Porbandar, Repair/ Maintenance Of Fire Fighting System/ Fire Alarm System, Eot Cranes And Allied Works At Nae, installation Sardar Patel, Nofra, Nsb, Mes Complex And Comprehensive Repair Of Ac Plant And Other Allied Works Nae Under Cwe (Subs) Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | M&L for overhauling of compressor of capacity 40 TR of Make Voltas Model 05046S complete all as directed for improved performance and designed parameter as specified including the following at AC plant:- (a) Pumping down the compressor and transfer existing refrigerent gas, complete dismantling of each part of compressor and replacing the defective parts as found and reassembling the complete compressor, then oil charging, and doing pressure test using N2 gas as specified & hold for 24 Hrs to detect leakage and again same tests after repairing the leakage to ensure no leakage in the complete system, after that vaccuming the compressor to remove moisture & air complete all as specified & directed by Engr-in-Charge. Note :- 1) Refrigerant Gas, Oil and spare parts etc will be measured and paid separately under relevent item of Schedule |
| 2 | Supply & charging of compressor oil N68 Suitable for R-22 Refrigerant Compressor of Model Voltas compressor Model 05046S model including draing out old oil complete all as specified & directed by Engr-In-Charge Make :- Bharat Petroleum /Hindustan Petroleum |
| 3 | Supply and charging of Refrigerant Gas R 22 up to required pressure and quantity in AC plant Note:- Gas will be supplied in pack cylinder Complete in all respect all as specified & directed |
| 4 | Supply and fix in replacement HP cutout switches suitable for Voltas compressor Model 05046S including dismantling old unserviceable all as specified and directed by Engr-In-Charge. Make: Danfoss KP 1 /Indofoss. |
| 5 | Supply and fix in replacement LP cutout switches suitable for Voltas compressor Model 05046S including dismantling old unserviceable all as specified and directed by Engr-In-Charge. Make: Danfoss KP 1 /Indofoss or equivalnet it . |
| 6 | Supply and fix in replacement industrial type temperature gauge suitable for central AC plant of 40 TR capacity. |
| 7 | Material and labour for disconnecting for Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for 2 x 40TR Capacity AC Plant at Hanger 343 of NAE POrbandar. |
| 8 | M&L for detection of leakage using Nitrogen gas at AC Plant in Refrigerant Line , Evaporator Coil /colling coil using proper pressure test after completion of overhauling of compressor as per Sl item no 1 ,detecting the leakage as per standard procedure & attending the repair complete in all respect by bronze soldering stick with gas welding or any other suitable measure & Vaccuming the same after Nitrogen test all as specified and directed by Engr-In-Charge |
| 9 | Material and labour for disconnecting condenser for descaling & plugging them & providing of 15 mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be used for descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7 flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulating diluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for 2 x 40TR Capacity AC Plant at Hanger 343 of NAE POrbandar. |
| 10 | Material and Labour for dismantling of existing Air Handling Unit of any 2 x 40 TR capacity acrefully , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as directed by Engineer -in-charge. |
| 11 | Overhauling of CT fan motor of Delta cooling Tower capacity 50 TR after removing from the base plate,dismantling, replacing unserviceable bush /bearing /minor parts for repair purpose including cleaning,varnishing ,insulation replacement of bearings and greasing etc. complete and reassembling the same for smooth functioning complete suitable for AC plant all as specified & directed |
| 12 | M&L for Rewinding of unserviceable electric motor 3 phase 50 Hz 415volt of 5 HP capacity pump set complete comprises as under :-(a) Disconnecting & removing the electric motor from installed position including, loading, unloading and transporting to approved workshop.(b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wire of existing gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. complete for class 'F' insulation.(c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete.NOTE: Any damage caused during handling will be made good without any extra cost to department |
| 13 | M&L for complete Over hauling of Monoblock pump of 5 HP capacity set after removing from the base plate, disconnecting from pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacity of pumps |
| 14 | Material and labour for Repairs/Replacement Expansion valve of 40TR chiller unit complete all as specified and directed by Engineer-in-Charge.Make: Sporlon or equivalent |
| 15 | M & L for servicing of LT panel including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable, cutting and jointing the cables servicing of MCCBs/MCBs/Bush Bar/ Checking/Replacing of Nut Bolts etc. cleaning of all joint make joint Carbon free and remove rusted part by chemicals and painting the panel with synthetic enamel paint two coat complete all as specified and directed by Engineer in Charge.Note: i) The items i.e. MCCBs/MCBs, of suitable size shall be measured and paid seperately under various item.ii) The material and labour required for servicing of LT panel i.e consumables/nut bolts etc shall be deemed to be included in the item rate. |
| 16 | Suply & Fix in replacement MCCB 250 Amps 4 Pole 36 KA with thermal magnetic release complete all as specified and directed. Make L&T Desine series /schenider/Legrand |
| 17 | Supply & fix in replacement oil seal assembly in the existing Compressor 60 HP capacity including testing on completion complete all as specified and directed . |
| 18 | Taking down old unserviceable/deteriorated insulation from duct, cleaning the duct surface with steel wire brush to remove dirt, dust and make it free of scale, greases and foreign matter etc and supply and fix nitrile rubber insulation (Armaflex) one layer of 19mm thickness sticking on surface of duct / pipe line by using best quality adhesive and sealing the joints by weather proof tape complete all as directed . |
| 19 | Material and labour for manual scraping of old painted surface and providing spray painting with two coat of synthetic enamelled paint over a coat of primer on AC plant of 40 TR capacity including associated compressor, condensor and pipelines complete all as specified and directed by Engr-in-charge. |
| 20 | Supply and fix Battery suitable for 12 Volts DC supply 7.5A AH in existing fire alarm control panel, complete all as specified & directed. Make AMARON/Exide or equivalent |
| 21 | Servicing of Fire fighting pumpsets electric driven including disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out the pump set from base after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gaskets, assembling the pump with replacement of pulley key, gland packing rope, greasing, transporting back to site and fixing on the existing foundation, connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items. |
| 22 | Fire pump set of capacity 40 HP at INS SP |
| 23 | Jockey pump set of capacity 12.5 HP at INS SP |
| 24 | Booster pump of capacity 7.5 HP at INS SP |
| 25 | Mono block pump set of 10 HP at NSB Blgs (12 Nos) and Nofra Bldg (06 Nos) |
| 26 | Repair and maintenance of Diesel driven fire pump set, 60 HP horizontal end suction, centrifugal type with CI casing , stainless steel impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation of 440 V , 3 phase, 50 Hz AC supply 45 m Head. 2280 LPM discharge, disassemble and check machine assembly , Clean up the carbon deposits in the combustion chamber,exhaust pipe and muffler, Measure the quantum of wear and tear in the cylinder and change the piston ring and cylinder liner, Check the concurrence between the connecting rod bearing and the crankshaft main bearing, replace the bearing, check the axial concurrence of the camshaft and crankshaft, and acclimate , Check the miserliness of the stopcock seat and grind, Clean the cylinder block, oil painting visage and oil painting strainer, Clean the dirt on the heat exchanger and machine water tank, and check the function of the thermostat. ,Remove the pump, clean and change the oil painting; remove the dirt, Perform a pressure test of 1.5 times the rated outlet pressure of the channel affair system, complete paint the machine assembly, complete all as specified and directed. |
| 27 | Routine maintenance and testing of fire fighting system including fire pump and Hydrant system complete by attending fault testing of system, checking of system etc, (03 times during the contract period at regular interval) including replacement of unserviceable component including preventive Maintanence by replacing parts other than mentioned in relevent item of this sch also for fire fighting system installed at Senior Sailor Block ( S1-S7 Building total 07 Nos), Junior Sailor Block (J1-J5 Building total 05 Nos), at NOFRA (P-120 to P-122, total 03 Nos Building ) , INS SP, serving of each floor of bldgs comprising following: (a) All cable connectors from main control panel to Zonal fire panel.(b) Pumpset Connection checking and 3 phase connection including minor maintainace in connections.(c) Complete oiling/ Greasing in bearing, couplers, fans.(d) Checking of all inlet outlet valves including routine serviceaing of valves and gland packing changing.(e) Making pumpset on and run pumpset for full capacity for at least 15 min and checking hydrant system at each floor all Minor maintainace part deemed to be included in rate. The Parts of higher cost measured and paid seperately. (Total High rise Bldgs - 12 Nos , INS SP - 03 Bldgs , = 15 x 03 Job = 45 Job |
| 28 | Routine maintenance and Testing of “FIRE ALARM CONTROL PANEL” system consisting of multi sensor detector, hooter, siren , manual call point, control panel complete in repairs including wiring and programming in bldgs (03 times during the contract period at regular interval) ( Total High rise Bldgs - 12 nos , INS SP - 03 Bldgs , = 15 x 03 Job = 45 Job) complete with the following:(a) Manual call point with electronic hooter (one in each floor)(b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator, Fire Smoke detector for each zone complete. |
| 29 | Servicing and reparing of unserviceable parts of Fire fighting terrace pump control panel indoor type 2.00 mm thick CRCA sheet having 40 Amps incoming MCCB and 10 HP starter with MCB TP 32 Amps as outgoing accesories. including disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out after opening nuts/bolts, transporting from site to workshop, serviceacing transporting back to site and fixing on the existing position connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items. |
| 30 | Material and labour for cleaning of underground fire pump house sump by draining out the water after pumping by arranging de-watering pumps or by manual operation and wash the walls & bottom surface by high pressure spray with rotary water jet pumps and removing the sludge and foreign matters complete by and socking out the fixing with high pressure wet vacuum pumps scrubbing the wall and cleaning the entire sump including disinfectioning the tanks with spray of chemical approach by concerned authorities complete all as directed by the Engineer-in-Charge |
| 31 | Supply and fix in repair/replacement of manual call point ressetable type duly painted in red colour paint fitted with front glass (to be broken in case of fire) complete with hammer and test key to check the response with out breaking the glass with LED indicator all as specified . Make : Appolo/Agni Surksha |
| 32 | Supply and fix in repair/replacement electronic hooters complete all as specified and as directed by Engineer-in-Charge. Make : Appolo/Agni Surksha |
| 33 | Supply,fixing,in repair/replacement Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360. Make : Agni or eqivalent |
| 34 | Supply and fix in repair 63 mm dia 15 meter long RRL (Reinforced Rubber Lined) Fire hose with jacket 100% synthetic yarn fabric reinforced conforming to IS 8423:1994 complete with male and female coupling conforming to IS 903 complete all as directed by Engr-in-charge. Make:- NewAge / Essel / Swati / Safex/Agni |
| 35 | Supply and fix in repair 63 mm dia 30 meter long RRL (Reinforced Rubber Lined) Fire hose with jacket 100% synthetic yarn fabric reinforced conforming to IS 8423:1994 complete with male and female coupling conforming to IS 903 complete all as directed by Engr-in-charge. Make:- NewAge / Essel / Swati / Safex/Agni |
| 36 | Repair replacement rubber hose reel including reel drum of swivelling type of 20 mm size of 30 mtr length including nozzle complete all as specified and directed at site by Engineer-in-Charge. Make:- NewAge / Essel / Swati / Safex/Agni |
| 37 | Supply and fix in Repair/replacement of “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring in high rise building upto G + 08 stories complete with the following:(a) Manual call point with electronic hooter (one in each floor)(b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator for each zone complete. Make : Agni or equivalent |
| 38 | Repair replacement for single out let fire hydrant with gun metal body having 63mm dia out let with valve and instantanious type female coupling with cap on outlet suitable for fixing on 80/100/150mm flange including taking down of the old fire hydrant complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and Fix in repairs internal hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600mm X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside and concealed in wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend \\" FIRE HOSE\\" painted prominently in graphic style and all as specified and directed |
| 40 | Supply and Fix in repairs outside hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600mm X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside and concealed in wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend \\" FIRE HOSE\\" painted prominently in graphic style and all as specified and directed |
| 41 | Supply & fix fire hydrant operating GI wheel suitable for operating 63/80 mm dia outlet valve all as specified and directed by Engineer-in-Charge. |
| 42 | Supply & fix brass blank cap and hose lock with 15 cm MS chain suitable for single/double fire hydrant including taking down the old cap & lock complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply and fix in repair steel lock pin (lugs) for 65/80 mm dia complete all as specified and directed by Engineer-in-Charge. |
| 44 | Repair replacement blank MS flange of size 100 mm made out of MS 12 mm thick including flange joint complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fix in repair brass nozzle suitable for 20 mm dia rubber hose pipe complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply and fix in repairs brass hydrant valve nut as per existing size complete all as specified and directed by Engineer-in-Charge. |
| 47 | Repair replacement PVC blank cap of hydrants with GI chain complete all as specified and directed by Engineer-in-Charge. |
| 48 | Servicing complete to hose reel drum by applying greasing, oiling etc for making free rotation complete and painting two coats of synthetic enamel red paint over a coat of metalic primer complete all as directed. |
| 49 | Servicing complete to twin out let/single out let hydrant by applying greasing, oiling etc for making free rotation complete and painting two coats of synthetic enamel red paint over a coat of metalic primer complete all as directed. |
| 50 | Servicing complete to Sluice valve of size 80/100/150 mm dia (in position) in existing position at site by applying greasing, oiling , packing , Checking threaded rod, etc for making free rotation complete and painting two coats of synthetic enamel black paint over a coat of metalic primer complete all as directed. |
| 51 | Material and labour for repair/replacement of cast iron sluice valve with flanged end class PN 1.6 including all joints with rubber gasket, bolts, and nuts washer complete all as specified of sizes :- Make : Kirloskar/Zoloto/Kartar |
| 52 | 150 mm bore |
| 53 | 100 mm bore |
| 54 | 80 mm bore |
| 55 | Supply and fix in repairs Foot valve cast iron body both ends flanged suitable for 100 mm bore CI pipe connection all as specified and directed. Make -Kirloskar/Kartar/Zoloto/AUDICO |
| 56 | Material and Labour for painting of fire hydrant/fire hose box of any size with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc all as specified and directed by Engineer-in-charge. |
| 57 | Taking down old GI tubing 80 mm bore heavy class fixed on wall etc including making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and fix in Repair replacement GI tubing 80 mm bore heavy Class complete with fittings like; Tee, bends, flanged etc to be fixed on wall or laid in trenches complete with drilling, welding, bending shaping etc all as specified and directed by Engineer-in-Chage. |
| 59 | Taking down old GI tubing 100 mm bore heavy class fixed on wall or laid in trenches including making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix Repair replacement GI tubing 100 mm bore heavy Class complete with flange type fittings like; Tee, bends, flanged etc to be fixed on wall or laid in trenches complete with drilling, welding, bending shaping etc all as specified and directed by Engineer-in-charge. |
| 61 | Material and labour for painting in existing position at site of GI/ MS pipe of size 80/100/150 mm dia, not exceeding 60 cm girth (in position), with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc all as specified and directed by Engineer-in-Charge. |
| 62 | M&L for renewal of valve pit of size up to 80 cm x 80 cm x 80 cm (internal diamension), stone / brick construction including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, PCC in foundation for mix (1:2:4) type D2 brick mansonary in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally ,finished even and fair and polishing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6 mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all exposed MS work with two coats of synthetic enamel paint of the that as approved by the Engineer - in - charge over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint complete all as specified. |
| 63 | Repair / Replacement of Contactor for starter for 10 HP pumpset tarrece fire fighting. Make L&T Model MNX-12 or equivalent in other make |
| 64 | Repair / Replacement of single phase preventor 240 V for starter of 10 HP at fire fighting panel Make : Minilec or equivalent |
| 65 | Supply and fix in repair Pressure gauge of 4\\" dial 0-14 kgs rating with ball valve including taking up / down old unserviceable pressure gauge from any position and any addition / alteration for fixing required complete all as specified and as directed. Make: FIEBIG/ H. GURU/ BAKER MERCER/ DANFOSS |
| 66 | Supply and fix in repair/replacement Fire brigade inlet connection 2way complete all as specified and as directed |
| 67 | Repair / Replacement indicating Lamp (Red,Green,orange or blue) for indicating ON,OFF,TRIP all as specified and as directed. Make : L&T or equivalent |
| 68 | Repair / Replacement selector switch for fire fighting pumpset panel all as specified and as directed. |
| 69 | Repair / Replacement digital voltmeter for fire fighting pumpset panel all as specified and as directed.Make : Schneider or eqivalent |
| 70 | Repair replacement digital Ammeter for fire fighting pumpset panel all as specified and as directed.Make : Schneider or eqivalent |
| 71 | Srapping and Painting, filling cavities of rusted parts and two coat exposed body surface with synthetic/Oil paint over one coat of red oxide paint 10 HP Pumpsets of any capacity. Colour of pumpset shall be Blue all as specified and directed by Engr-in-charge. |
| 72 | Srapping and Painting, filling cavities of rusted parts and two coat exposed body surface with synthetic/Oil paint over one coat of red oxide paint Fire fighting panel of any capacity. all as specified and directed by Engr-in-charge. |
| 73 | Repair / Replacement PVC insulated, heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core from fire fighting panel to Pumpset all as specified and directed.Make : Polycab or equivalent |
| 74 | Repair / Replacement of PVC insulated PVC sheathed cable galvanized steel strip or wire armored, electronic control cables (Heavy Duty) with stranded Copper conductor of size 2.5 sq mm 4 core 1100 Volts grade. |
| 75 | Repair / Replacement of CI Non return valve of 100 mm Butterfly size all as specified and directed. Make Balaji or equivalent |
| 76 | Comprehensive maintenance of electrically operated travelling (EOT) crane of 02 Ton capacity (02 Nos), Span 10 meter approx, Bay length 35 meter approx, height of lift 7 meter approx, floor operated through pendent puch button, comprising of hoist motor, micro motor, long travel, cross travel motor, gear box, control panel and other connected accessories installed at Technical Complex INS Sardar Patel Notes :- (a) Inspection checking decarbonising & tightning of electrical connection in total system including replacement of thimbles etc. (b) Inspection & checking of gear motor, setting, greasing, Oiling and tightning the same as per their capacity.(c) Inspection & setting of voltage system including replacement of fused indicating lamp etc.(d) Spares for EOT crane will be measured and paid seperately.(e) Contractor will carry out comprehensive maintenance once in a month for the duration of contract period and maintain the record of the same as per the performa and as directed by Engh-in-charge(f) Any breakdown during concurrency of contract shall be repaired by contractor within 48 hrs without any extra cost Please Enable Macros to View BoQ information |
| 77 | Comprehensive maintenance of electrically operated travelling (EOT) crane of 02 Ton capacity (02 Nos), Span 10 meter approx, Bay length 35 meter approx, height of lift 7 meter approx, floor operated through pendent puch button, comprising of hoist motor, micro motor, long travel, cross travel motor, gear box, control panel and other connected accessories installed at Technical Complex INS Sardar Patel Notes :- (a) Inspection checking decarbonising & tightning of electrical connection in total system including replacement of thimbles etc. (b) Inspection & checking of gear motor, setting, greasing, Oiling and tightning the same as per their capacity.(c) Inspection & setting of voltage system including replacement of fused indicating lamp etc.(d) Spares for EOT crane will be measured and paid seperately.(e) Contractor will carry out comprehensive maintenance once in a month for the duration of contract period and maintain the record of the same as per the performa and as directed by Engh-in-charge(f) Any breakdown during concurrency of contract shall be repaired by contractor within 48 hrs without any extra cost Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender