Tender for Addn/Alteration Of Internal Wiring And Panelling Work In Bldg No. T-149 At Hq Cif (R) Under Age (I) Cif (R )
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets. |
| 2 | S&F AC designer composite ceiling board 4-6mm thick in 600x600mm panel confirming to IS-14682 TYPE-B category-3 including GI frame, holdfast and suspenders complete all as specified and as directed by Engr-in-charge |
| 3 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 4 | Non-skid coloured ceramic tiles (square/ rectangular) 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes, pointed in white or coloured cement to match the surface complete all as specified and directed. |
| 5 | M&L for light shade Vitrified tiles 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc.Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of existing surfaces.(Note:The contractor shall have no claim on difference what so ever on shade /colour of tile) |
| 6 | -------ditto ----- but on vertical surfaces as in skirting including 8-10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed. |
| 7 | Glazed ceramic tiles in vertical surface 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in 10 mm thick cement mortar 1:3 and finished even and rough complete all as specified and directed. |
| 8 | Taking down wall panelling and similar work complete all as specified and directed. |
| 9 | S&F, solid PVC Wall lining consisting of 5mm thick wood grain printed colour PVC sheet as in striups and chanel inclusive of solvent cement and fixing at site on necessary pvc wooden frame incl fillets as per specifications. |
| 10 | Taking down chowkhat or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) complete all as specified and directed. |
| 11 | All as per ser item No 10 above but exceeding 1.50 Sqm and not exceeding 4.00 Sqm complete all as specified and directed. |
| 12 | S&F glazed anodised (15 micron) powder coated Aluminium door made out of extruded section as standard door frame, single groove of size 100 x 45 x 2.5 mm th standard shutter top and bottom section of size 95 x 45 x 2.5mm th standard shutter vertical section of size 80 mm x 45 mm x 2.5 mm thick complete with auto hydraulic floor mounted door closer handle special cylindrical lock, neoprene dry set ,rubber gasket, with 12m th prelaminated (both side) particle board & 5mm th plain glass complete. |
| 13 | Aluminium anodised double shutter window (glazed and wire gauge) side hung/sliding with aluminium windowr frame of chowkat 1.5mm thick aluminium anodised of size 100mm x 44.5mm and window shutter frames glazed and wire gauze(middle, top rail, bottom rail) and styles 1.5mm thick aluminium anodised of size 44.5x44.5mm incl aluminium grill, stainless steel wire mesh and all fitting such as rubber gasket aluminium glazing clips and including 4mm thick tinted glass pane in glazed shutter fixed with rubber gasket and glazing clips/ aluminium beads aluminium tower bolt 100mm 02 Nos in each shutter, aluminium butt hinges 100mm 02 Nos in each shutter aluminium handle 75mm 01No each shutter incl all accessories complete all as specified and as directed. |
| 14 | S&F powder coated aluminium frame and grill for door, window,ventilators with one or more rebated incl jointing cleat for fixing etc complete all as spfd |
| 15 | Demolition of cement concrete (unreinforced) in ground floor, paving not exc. 15 cm thickness (below or above ground level) complete all as specified and directed |
| 16 | M & L for 50 mm thick cement concrete 1:3:6 type C 2 (40 mm graded aggregate ) as in plinth protection, finished even and smooth without using extra cement complete all as specified and directed |
| 17 | Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc |
| 18 | Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLSH) cable, 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLSH) cable for earth continuity wire, connected to earth dolly and in including modular pressed steel sunken boxes of required size with modular cover plate with frame for mounting modular switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to disturbed surface and pointing in using cement mortar 1:3 all as specified and as directed for the following. |
| 19 | One light/fan/exfan/call bell etc. point controled by one 5/6 Amp modular type switch |
| 20 | One 3 pin socket outlet 5 Amps on same board. |
| 21 | One 3 pin socket outlet 5 Amps on indpendent board |
| 22 | All as per item No 18 here in before but point wiring with 2.5 sqmm FRLSH multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15/16 Amp switch on independat board, complete all as specified and directed. |
| 23 | S&F in replacement of modular switch single pole one way 6 Amps 1 module complete all as specified and directed. |
| 24 | S&F in replacement of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed. |
| 25 | S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed. |
| 26 | S&F in replacement of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed. |
| 27 | S&F in replacement of ceiling rose 65x50 mm two to three terminals polycarbonate type complete all as specified and directed. |
| 28 | S&F in replacement of modular fan regulator, electronic step type heavy duty modular 2 module 230 volts, 120 watt complete all as specified and as directed. |
| 29 | Supply & fix in replacement of Call bell ding dong/buzzer type AC 230 volt single pole complete all as specified. |
| 30 | Supply and fix Exhaust Fan heavy duty, metal body complete with frame and louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 300 mm inluding making fixing arrangements including cutting of wall/surface for fixing of exhaust fan and making good the disturbed surface shall be part of job at no extra cost. |
| 31 | Supply and fix Exhaust Fan heavy duty, PVC body complete with frame and louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 200 mm inluding making fixing arrangements including cutting of wall/surface for fixing of exhaust fan and making good the disturbed surface shall be part of job at no extra cost. |
| 32 | S&F in replecement of Ultra slim LED light to new 36W, 6500 K LED (CDL/WW type as per site requirement) recess mounted bakelite panel of size 2 x 2 feet luminaire suitable for surface/grid ceiling for low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector including taking down old unserviceable luminaire, complete all as specified and as directed. |
| 33 | S&F in replacment of LED tubelight fitting 1x20Watt batten type fitting 4 feet long aluminium extruded housing IP-20 rated rated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hz system wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, system lumen efficacy 100 lm /watt ,CCT 6500K complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75 sqmm 3 core all as specidfierd and directed. |
| 34 | All as per item No 14 here in before but LED tubelight fitting 1x10Watt batten type fitting 2 feet long, complete all as specified and directed. |
| 35 | Supply and fixing LED street light fitting 25/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant ncomplete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete with 25 mm dai bend bracket for mounting arrangements all as directed by engr-in-charge. |
| 36 | S&F of box of plug & top, AC 230 Volts, with MCB SPN 25 Amps complete suitable for AC split/Window type of 1.5 TR capacity all as specified and directed. |
| 37 | S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 6 sqmm cable and one run of 6.00 sqmm earth wire with PVC casing and caping shall be measured as one unit. |
| 38 | S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as one unit. |
| 39 | All as per item above but SPN 8 ways 240 volts complete all as specified and directed. |
| 40 | All as per item above but SPN 12 ways 240 volts complete all as specified and directed. |
| 41 | Supply and fixing in replacement of MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB 63/100/125 Amps 4 pole, including grouting in the wall, cutting & chasing/surface mounting etc. as per site requirement complete all as specified. |
| 42 | S&F in replecement of MCB SP 6 to 32 Amp, 240 volts complete all as specified. |
| 43 | S&F in replecement of MCB SPN 32-40 Amp, 240 volts 50Hz AC supply, complete all specified. |
| 44 | S&F in replecement of MCCB 100 Amp,4 pole, 25 KA 415 volts 50Hz, AC supply, complete all specified. |
| 45 | M&L for replacement of under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 50 Sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately. |
| 46 | Excavation in trenches, in any type of soil not exc 1.5 mtr wide and not exc 1.5 m in depth for foundation, etc or not exceeding 10sqm on plan and not exceeding 1.5m in depth for pole, shafts, cesspits, manholes, pier holes, etc. and getting out of any type of soil for laying UG cables of various sizes complete all as specified and directed. |
| 47 | Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm in any type of soil. |
| 48 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 49 | Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed |
| 50 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. |
| 51 | S&F in replacement of GI pipe light grade 40 mm complete for laying under PCC/bitumonus road or critical narrow trench, under floors and mechanical protection of UG cable. |
| 52 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4.0 mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. All as specified and directed. |
| 53 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire |
| 54 | Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long. |
| 55 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required for 32x6 mm galvanised iron strip |
| 56 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required for 25x3 mm aluminium strip all as directed by Engr-in-Charge. |
| 57 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6 mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I |
| 58 | M&L for test point terminal block made of gunmetal or phosporus bronze of size 75 x 75 x 25 MM , drilled & screwed including 3 Nos 8MM dia 25 MM long hexagonal head screw including 2mm thick MS box of size 150 x 150 x 100 MM thick with locking arrangement complete all as specified and directed. |
| 59 | M&L pipe galvanized iron light grade 32 MM bore complete with all fittings and fixed as termination rod 1.2 m long each complete to fix at roof top complete all as specified and directed. |
| 60 | Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 17,986 during AOCNote:- Tenderers shall not quote for this Schedule Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender