Tender For Demolition And Re-Construction Of Existing Perimeter Wall (Ph-Ii) With Lighting Facilities And Construction Of Watch Towers At Afs Begumpet
Tender Value
2.89 Crore
Estimated cost
Bid Submission
14 Nov 2026
26 days left
EMD
3.65 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Demolition And Re-Construction Of Existing Perimeter Wall (Ph-Ii) With Lighting Facilities And Construction Of Watch Towers At Afs Begumpet
BOQ
| Sl. No. | Item Description |
| 1 | BOQ No.1 |
| 2 | GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to IX are prepriced by MES under Ser No. 2 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 3 | Lumpsum price worked out by the contractor for “BUILDINGS OR WORKS” as listed in Schedule ‘A’ Part–I |
| 4 | Lumpsum price worked out by the contractor for “DEMOLITION OF BOUNDARY WALL” as listed in Schedule ‘A’ Part–II |
| 5 | Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part–III |
| 6 | Lumpsum price worked out by the contractor for \\"INTERNAL ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part -IV . |
| 7 | Lumpsum price worked out by the contractor for “PATH” as listed in Schedule ‘A’ Part – V. |
| 8 | Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part – VI. |
| 9 | Lumpsum price worked out by the contractor for “FENCING/BOUNDRY WALL AND GATE” as listed in Schedule ‘A’ Part – VII. |
| 10 | Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – VIII. |
| 11 | Lumpsum price worked out by the contractor for \\"EXTERNAL ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part -IX. |
| 12 | Sch 'A' Part - X : Fittings / Fixtures & Misc items. |
| 13 | DEMOLITION OF BOUNDRY WALLDismantling concertina coil (any dia) complete all as specified and as directed |
| 14 | Dismantling barbed wire complete all as specified and as directed. |
| 15 | INTERNAL ELECTRIC SUPPLY: Supply and fix exhaust fan, AC, single phase, 240 V, 200 mm sweep, PVC body with louvers, including connected with 3 core 1.5 sq mm copper conductor cable from ceiling rose to exhaust fan all as specified and as directed. |
| 16 | Material and labour for Earthing complete with galvanized iron earth plate electrode of size 600mmx600mm x 6.3 mm thick buried directly under ground vertically to depth not less than 2.25 meter below ground level with top edge of plate at a depth not less than 1.5 m below ground level connected to and including GI wire 4mm dia and GI protection pipe 15mm dia and light grade connected to and including by means of bolts nuts check nuts and washers made of copper as shown plate no 3 of SSR part 1 to the extent applicable to this item including necessary excavation earth work , PCC 1;3;6 chamber RCC 1;2;4 cover 50mm tick with 6mm TMT bar 100mm center to center watering pipe medium grade 20mm boe funnel wire mesh etc. and testing on completion all as specified and as directed. |
| 17 | Supply and fix modular telephone socket RJ-11 one module all as specified and as directed by Engr-in-charge |
| 18 | Material and labour for Mild steel box of telephone wiring including blocks, suitable for 30 pair all as specified and as directed by Engr-in-charge. |
| 19 | Material and labour for Telephone wiring with unarmoured solid annealed bare copper industrial cable in concealed of size 0.5 mm, 3 pair with PVC conduit 25 mm dia all as specified and as directe by Engr-in-charge. |
| 20 | SEWAGE DISPOSAL :Supply and fix on site LLDPE septic tank Conventional type , for 05 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all specified and as directed. |
| 21 | FENCING/BOUNDRY WALL AND GATE Supply and fix concertina coils super barbed bladed profile of dia 600mm and weight of coil for 50 spiral turns shall not be less than 0.9 kg and one coil (50 spiral)shall not be streached to more than 6.0 mt blade shall be 0.50mm thick galvanised steel strip and 2.5mm dia core wire fixed to angle iron brackets or masonry surfaces with necessary accessories like straining wires, fixing clips etc complete all as specified and as directed by Engineer-in-Charge. |
| 22 | EXTERNAL WATER SUPPLY Material and labour for Cutting of Existing Pipe line of diameter upto 80 mm dia in Position for insertion of new TEE, Supply and fixing of Union and Tee Reducer of required size dimention and reconnecting the main water supply line with all required fittings complete all as specified and as directed by Engr-in-Charge. |
| 23 | Material and labour for construction of Valve chamber having inner dimension 600x600x600 mm suitable for gate valve upto 50mm with PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for copping, rendering plaster in CM 1:4, 15mm thick including provision of MS sheet top cover 3mm thick with brazing of MS flat of Size 25mm x 4mm at edges and in diagonal and angle iron base frame of 40 x 40 x 5mm painting with two coat of synthatic enemel paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work complete all as specified and as directed. |
| 24 | EXTERNAL ELECTRIC SUPPLY : Supply and installation, testing and commissioning of silent Diesel Engine driven generating set with acoustic enclosure,415 volts, 15 KVA/12KW, 3 phase 4 wire, with Automatic on mains failure (AMF) Panel,0.8 power factor, 50 Hz, , 1500 RPM, self excited, self regulated, brushless AC generator suitable for ambient condition complete with relay panel for automatic starting on mains failure control panel and confirming to latest CPCB norms and IS for DG Set with acoustic enclusure complete with the following : (a) Diesel Engine: Adequate Capacity diesel engine producting not less than 25 BHP at 1500 RPM, Water cooled, directly coupled through flexible coupling multi cylinder, multi stroke direct injection, cold starting with capable of 12 Hrs continous running and 01 Hr running with 10% Overload complete with standard accessories all as specifiedas and as required for safe handing and operation. Make of DG Set should be same make of Engine mentioned in here-in-after. (b) Alternator Standard design alternator rated at 15 KVA, net output at power factor 0.8, AC, 3 Phase 4 Wire, 415 Volts, 50 Cycles, 1500 RPM self excited,self regulated, screen protected drip proof IP 23 brushless design with hub and shield/roller bearing with winding in each face insulating class 'F' Band of voltage regulation to generate supply with frequency / regulation within + 1% tolerence. |
| 25 | (c) Generator monitoring panel - comprising of all standard items as mentioned under this schedule or as per standard practice of manufacture, ignition key switch, start/stop arrangement indication for engine parameters, hour run meter, RPM meter, engine oil pressure indication, water/coolant temparature indication, battery vilts display, annunciation with indication lamps for, low lube oil pressure, high water temperature, engine over speed, battery low voltage. |
| 26 | (d) AMF Control panel: Factory fabricated cubicle type, free standing, floor mounted, outdoor type, IP-66, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 3.0mm thick CRCA sheet duly powder coated and comprising of following: (ii) MCCB 415V. 3 phase 63 A adjustable, 16 KA-02 (one for main supply & one for DG set supply)(III) Suitable Power contactor four pole - 02 Nos (one for main supply and one for DG set supply)(iv) Copper bus bar TPN 100 Amps - 01 set(v) Suitable battery charging unit -01 No(vi) DIgital multifunction meter for display of voltage, current, frequency, KVA, KW, KWH and PF.(vii) Electronic hooter(viii) Indication lamp for main ON, load mains, DG set ON, load on DG set, Battery DC supply ON.(ix) Voltmeter and ammeter for battery charging.(x) Suitable for MCBs for control circuit.(xi) Supply and lay control cable LT 1100 volts PVC insulted armoured heavy duty copper conductor of suitable size multicore (from DG set monitoring panel to AMF panel)(xii) Rubber matting of LV grand 19mm thick of suitable size chequered. |
| 27 | Notes :1 .Some of the salient features of Diesel Engine shall be as under :-(i) Radiator with blower fan or heat exchanger with guard.(ii) Pipe coupling for engine cooling system piping.(iii ) Corrosion inhibitor coolant(iv) Paper element filters for Fuel,Lube oil & By pass(v) Fly wheel housing and fly wheel to suit alternator.(vi) Engine bearing mechanism in fly wheel housing(vii) Shut off coil with safeties for LLOP/HWT/over speed.(viii) Battery charging alternator.(ix) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(o) Interconnecting copper cabling of adequate capacity.(p ) Fuel pipe as required (q) Self starter(r) Electronic governor.(s) Fuel injection pump. |
| 28 | 2. Fuel Tank :- The inbuilt fuel tank shall be mild steel suitable to hold fuel for not less than 12 hours running capacity and shall be including fuel level indicator, fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling from exterior canopy (without opening its DG panel). 3. Battery :- Suitable Maintenance free battery with leads & terminals as per OEM recommendation. 4. Acoustic Enclosure:- Acoustic enclosure with outer body made of CRCA sheet of thickness as recommended by manufacturer and sound insulation by Rock wool to reduce noise level to as per guide of Central Pollution Control Board or latest CPCB norms and OEM specification and inside illumination light fitting. |
| 29 | 5. Civil Work:- All civil works including PCC platform and foundation suitable for installation of DG set alngwith anti vibration pad. The depth of foundation & PCC shall be as per OEM Recommendations. Contractor should submit the foundation drawings for approval to Engr -in- Charge along with GA Drwaings. Rate quoted is deemed to be inclusive for this provision. 6. The Phase- I & PHASAE II TEST:- The phase-I Test will be performed for 1 hour without load after completion of installation by Engineer-in-Charge and Phase-II Test will be performed for 13 hours as mentioned in PS Clause by the rep of Accepting Officer.The Diesel, grease, engine oil. etc required for commissoning and testing shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department. |
| 30 | Supply and fix Octagonal shaped GI hot dipped (65 microns) internally and externally as per IS - 2629 minimum 3mm thick electric pole, Polished finished (7 metre long) Double arm bracket(1.5 Mtrs) complete with PCC base, bolts, nuts, washers and base plates all as specified including the following complete all as specified and as directed. Note:- (a) Excavation in post hole not exceeding for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres. (b) Material and labour for Providing PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation as per manufacturers design upto GL including Nuts, bolts, washers ,PVC pipe for cable and base plates of suitable size and length for grouting. (c) Inbuilt internal junction box consists of 4 terminals for cable and outgoing of MCB SP 6 Amps 10 KA. (d) attached GI Pipe Bracket made out of Galvanised Iron Tubing 40mm bore (dia), light grade, 1.50 Metre long bent to shape as per specified for fixing Street Light Fitting including taking out old existing poles and lights as schedule of credit complete all as specified and as directed. |
| 31 | Material & labour for taking out existing serviceable poles without damaging and intact shifting to MES storeyard for reuse complete all as specified and as directed. |
| 32 | Material and labour for Taking down old unserviceable Steel tubluar pole complete with PCC all as specified and as directed. |
| 33 | Supply and installation on LT Electric Control Panel, cubical type, for Out door use Floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 40mm x 40mm x 5mm having front and rear open hinged doors with front openable shutter for each MCCB / Timer with spreader compartment withfully enclosed bus bar chamber, having insulated busbar made out of aluminium strips of rating 150 Amps for 3 Phase , 415 Volts,50 Hz , 4 Wire system, with cable entry provision with suitable lugs , gland, Voltmeter, Ammeter, CTs and Phase indicator complete , duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut, bolts, washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items:- |
| 34 | INCOMER: (i) MCCB , 4 Pole, 63 Amps, rupturing capacity 16 KA thermal Magnetic Protection - 1 Nos (ii) Digital Ammeter 0-300 Amps CT Operated with selector switch - 01 Nos (iii) Digital Voltmeter 0-500 Volts with selector switch - 01 No (iv) LED Indication lamp in three colour RYB - 01 Set OUTGOING : (i) Street Light timer, switching ON and OFF the street light based on 3 Phase Astronomical time controlling switch for automatic controller of street light of 230 Volt Astronomical Time Switch- 02 Nos , 32 Amp MCB TPN - 4 Nos, 25 Amp 3 Pole contactor-2 Nos , indicator lamp, selector switch for auto / manual and internally pre wired , terminal blocks mounting brackets, cable glands etc and openable door with lock and key and manual setting features complete all as specified and as directed. |
| 35 | Material and labour for returning and filling of trenches using riddled soil obtained from excavated soil upto depth of 30cm(8cm below ground and remaining above cable ) for cushioning of UG Cable complete all as specified and as directed. Note : Remaining depth of Trench is filled with excavate soil and measured in Returning & filling item above) |
| 36 | Material and labour for road cutting /Hard standing for taking up or laying of LT UG Cable upto a depth of 15cm, after laying of cable well ramming to the excaved soil including repair the excavated portion of the road as existing or by providing suitable mixture of PCC complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender