Tender For Additional Improvement Works To Icds At Srinivasa Perumal Koil Street And Mgr 1St Street In Division - 20, Unit - 5, Zone 2
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Oct 2026
8 days left
EMD
5000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Additional Improvement Works To Icds At Srinivasa Perumal Koil Street And Mgr 1St Street In Division - 20, Unit - 5, Zone 2
BOQ
| Sl. No. | Item Description |
| 1 | Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with |
| 2 | Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor as directed by Department Officers and conducting yield test by ‘V’ notch method. Charges for developing the Borewell with air compressor of 600 CFM capacit |
| 3 | Supplying and stacking of sand (Supply and stackin...,sharp and angular type free of adherent coatings) |
| 4 | Supply and fixing of See-Saw 4 Seater FRP: Heigh...roduct area : 5’ft * 10’ft Play area:8’ft * 12’ft |
| 5 | upplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 6 | 1.5 HP Jet Pump Set |
| 7 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unshe...light point / fan point (for electronic regulator) |
| 8 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement |
| 9 | Supplying and fixing of FRP manhole cover and fra...ar opening) 900mm Dia (Medium Duty - 10MT) (SWD 9) |
| 10 | Providing and laying in position, standardised concrete Mix M-20 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including |
| 11 | Supplying, fabricating and placing in position Ribbed Tor Steel / TMT reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complyin |
| 12 | Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with |
| 13 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works. |
| 14 | Supplying and stacking of sand (Supply and stackin...,sharp and angular type free of adherent coatings) |
| 15 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement |
| 16 | Dismantling RCC by manual / by using deploying machineries |
| 17 | 1.5 HP Jet Pump Set |
| 18 | Dismantling - Brick / Stone in Clay Walls under 3m high |
| 19 | Providing UNDER REAMED PILES R.C.C.30cm (12\\") dia cast-in-situ with single reamed (bulb) in cement concrete 1:1.5:3, 11.5cm above G.L. including boring, erecting, vibrating,curing, hire charges for drilling equipments, etc.,complete as per relevent ISI specifications(excluding cost steel reinforcement). |
| 20 | Earth work excavation for foundation in all kinds soils in varying depths including dismantling any masonry or roots met within foundation and shoring with planks, baling water if necessary and filling the sides with excavated earth including clearing and levelling site etc., complete with an initial lead of 10m.and lift of 2m |
| 21 | Supplying stone dust and filling in regular laye...ting etc. complete for foundation, basement, etc |
| 22 | Plain Cement concrete work 1:4:8 (1 cement, 4 Crushed Stone Sand (Commercially called M-Sand) and 8 blue granite broken stone jelly 40mm gauge)including consolidation curing, etc. |
| 23 | Supplying and erecting shuttering including necessary supports for plane surface in foundation and basement for RCC column footings,pintol blocks, plinth beam, staircase steps, critical steps, critical piers,etc.,using mild steel sheets of size |
| 24 | Supplying and erecting centering for sides and soffits including supports and structting upto 3m high for plane surfaces such asRCC coloumns,top and bottom slabs of boxing. sill labs,sun shades,etc.,with necessary facia u |
| 25 | Providing and laying in position ,Standardised Concrete Mix M-20 Grade in accordance with IS :456- 2000,using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and m,aximum water cement ration of 0.55, including admixture (Plasticiser/S |
| 26 | Brick work using best quality II class table moulded chamber burnt bricks of size 9\\" X 4-3/8\\" X 2-3/4\\" in cement |
| 27 | Plastering with cement mortar 1:4 (1 cement and 4 P sand)12mm thickincluding curing, etc., complete. |
| 28 | Painting the new plastered walls with two coats of Exterior emulsion paint (weather proof ) first class quality and of approved colour over a priming coat including thorough scrapping,clean removal of dirt,etc.,complete and including necessary plaster paris,putty etc., wherever required.as per (ISI STD) (It must provide. |
| 29 | Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc.,complete,including painting a priming coat of approve |
| 30 | Painting new iron work two coats with ready mixed paint with relevent ISI STD of superior quality and approved colour. |
| 31 | Supplying, fabricating and placing in position Ribbed tor steel (RTS) for all RCC works as per design given including cost of steel and GI |
| 32 | PVC Water Tank Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender