Power Government Departments Closing in 15 days TDR #57978501

Tender For Supply, Survey, Erection, Testing And Commissioning Including Laying Of Lt/Ht After Creation Of 12 Nos 25 Kva Substation At Varnall-Ii (Sarwagani-A), Kharhall Neel D W.No 7 (Ladrihall), Upper Badla (Kumaitar), Pudlina Kutra (Karma), Nalyan

Issued by Government Departments · Doda, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Nov 2026
15 days left
EMD
6.84 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Doda → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Survey, Erection, Testing And Commissioning Including Laying Of Lt/Ht After Creation Of 12 Nos 25 Kva Substation At Varnall-Ii (Sarwagani-A), Kharhall Neel D W.No 7 (Ladrihall), Upper Badla (Kumaitar), Pudlina Kutra (Karma), Nalyan W.No 6(Sumber Upper), Senihall Bangara, Gohnihal, Beakh Phagmulla, Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla, W.No. 4 Mutlal (Alinbasss B),Charna (Ganote), Imnari Pogal Paristan (Rayisabad) And 2 Nos 63 Kva Sub Stns At Varnal Audik (Sarwagni A) & Bajuni Upper W.No 1,4(Sumber Upper) And Ht/Lt Only For St Basti Tanka Ward No 10, W.No 5, Upper Halla, Urendhar, Kadro (Dhundrath B) And Dhar, Larna, Darzangal (Dhundrath C) For Electrification Of Unelectrified Households Of Ukhral Ramsoo Ramban And Gool Blocks Of Ramban District Under The Jurisdiction Of Ed Jpdcl Batote (Scheme Code Pddss2425100377)

BOQ

Name of Work:- Supply, Survey, Erection, Testing and Commissioning including laying of LT/HT after creation of 12 Nos 25 KVA substation at Varnall-II (Sarwagani-A), Kharhall Neel D W.No 7 (Ladrihall), Upper Badla (Kumaitar), Pudlina Kutra (Karma), Nalyan W.NO 6(Sumber upper), Senihall Bangara, Gohnihal, Beakh Phagmulla, Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla, W.No. 4 Mutlal (Alinbasss B),Charna (Ganote), Imnari Pogal Paristan (Rayisabad) and 2 Nos 63 KVA Sub Stns at Varnal Audik (Sarwagni A) & Bajuni Upper W.No 1,4(Sumber Upper) and HT/LT only for ST Basti Tanka Ward No 10, W.No 5, Upper Halla, Urendhar, Kadro (Dhundrath B) and Dhar, Larna, Darzangal (Dhundrath C) for electrification Of Unelectrified Households of Ukhral Ramsoo Ramban And Gool Blocks Of Ramban District under the jurisdiction of ED JPDCL Batote (Scheme Code PDDSS2425100377)
Sl. No. Item Description
1Creation of New 63kVA Xmer at Varnall Audik village Sarwagmi A
263 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings
3Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
511 kV Horn Gap Fuse Set 3 Phase 200A
6120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
79 Mtr. Long Pole( ST-410 SP33)
811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
9GI Channel/Angle/Flat of sizes including clamps
10Galvinized Nuts and Bolts.
11Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
1211 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
13Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete.
14Wedge connctors/PG Clamps
15Danger plates with clamps
16GI Barbed wire for Anti Climbing
173-phase 4 wire Trivector meter with CT
18Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
19LT Distribution Box for 63 kVA DTR with MCCB forincomer & Switch Fuse Units for Outgoing Circuits
20Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
21Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
22Sundry Item like aluminium lugs, jumpers, binding tape.
23Laying of HT for Creation of New 63kVA Xmer Varnall Audik village Sarwagmi A
249 Mtr. Long Pole( ST-410 SP33)
25GI V cross-arm with top Bracket including clamp
26GI Channel X-arm including clamps and braces
2750 mm² ACSR Conductor
2811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
2911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
30Galvanized Nuts and Bolts
3111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
32Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
33Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
34Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
35Danger Plates with Clamps
36Anti-Climbing Device with Clamps
37Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
38Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
39Laying of LT for Creation of New 63kVA Xmer Varnall Audik village Sarwagmi A
408 Mtr. Long Pole(ST-410 SP15)
4130 mm² ACSR Conductor
4216 KN Shackle Insulator
43Galvanised M Clamp
44Galvanized Nuts and Bolts
45Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
46Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
47Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
48Danger Plates
49Anti-Climbing Device with Clamps
50Cement bottoming 1:2:4 mix as per REC standards.45cum /pole
51Creation of New 63kVA Xmer at Bajuni Upper W.No 1,4(Sumber Upper)
5263 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings
53Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
5411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
5511 kV Horn Gap Fuse Set 3 Phase 200A
56120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
579 Mtr. Long Pole( ST-410 SP33)
5811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
59GI Channel/Angle/Flat of sizes including clamps
60Galvinized Nuts and Bolts.
61Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
6211 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
63Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete.
64Wedge connctors/PG Clamps
65Danger plates with clamps
66GI Barbed wire for Anti Climbing
673-phase 4 wire Trivector meter with CT
68Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
69LT Distribution Box for 63 kVA DTR with MCCB forincomer & Switch Fuse Units for Outgoing Circuits
70Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
71Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
72Sundry Item like aluminium lugs, jumpers, binding tape.
73Laying of HT for Creation of New 63kVA Xmer at Bajuni Upper W.No 1,4(Sumber Upper)
749 Mtr. Long Pole( ST-410 SP33)
75GI V cross-arm with top Bracket including clamp
76GI Channel X-arm including clamps and braces
7750 mm² ACSR Conductor
7811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
7911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
80Galvanized Nuts and Bolts
8111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
82Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
83Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
84Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
85Danger Plates with Clamps
86Anti-Climbing Device with Clamps
87Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
88Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
89Laying of LT for Creation of New 63kVA at Bajuni Upper W.No 1,4(Sumber Upper)
908 Mtr. Long Pole(ST-410 SP15)
9130 mm² ACSR Conductor
9216 KN Shackle Insulator
93Galvanised M Clamp
94Galvanized Nuts and Bolts
95Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
96Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
97Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
98Danger Plates
99Anti-Climbing Device with Clamps
100Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
101Creation of new 25KVA Xmer at at Varnall -II village Sarwagni A
10225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
103Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
10411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
10511 kV Horn Gap Fuse Set 3 Phase 200A
10695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
1079 Mtr. Long Pole( ST-410 SP33)
10811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
109GI Channel/Angle/Flat of sizes including clamps
110Galvinized Nuts and Bolts.
111Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
112Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11332/63 amps TPN Switch Disconnector Fuse Unit
114Danger plates with clamps
115GI Barbed wire for Anti Climbing
116Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
117Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
118Laying of HT for Creation of new 25KVA Xmer at at Varnall -II village Sarwagni A
1199 Mtr. Long Pole( ST-410 SP33)
120GI V cross-arm with top Bracket including clamp
121GI Channel X-arm including clamps and braces
12250 mm² ACSR Conductor
12311kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
12411kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
125Galvanized Nuts and Bolts
12611kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
127Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
128Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
129Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
130Danger Plates with Clamps
131Anti-Climbing Device with Clamps
132Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
133Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
134Laying of LT for Creation of New 25KVA Xmer at at Varnall -II village Sarwagni A
1358 Mtr. Long Pole(ST-410 SP15)
13630 mm² ACSR Conductor
13716 KN Shackle Insulator
138Galvanised M Clamp
139Galvanized Nuts and Bolts
140Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
141Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
142Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
143Danger Plates
144Anti-Climbing Device with Clamps
145Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
146Creation of new 25KVA Xmer at Kharhall Neel D W.No 7 (Ladrihall)
14725 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
148Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
14911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
15011 kV Horn Gap Fuse Set 3 Phase 200A
15195 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
1529 Mtr. Long Pole( ST-410 SP33)
15311kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
154GI Channel/Angle/Flat of sizes including clamps
155Galvinized Nuts and Bolts.
156Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
157Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
15832/63 amps TPN Switch Disconnector Fuse Unit
159Danger plates with clamps
160GI Barbed wire for Anti Climbing
161Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
162Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
163Laying of HT for Creation of new 25KVA Xmer at Kharhall Neel D W.No 7 (Ladrihall)
1649 Mtr. Long Pole( ST-410 SP33)
165GI V cross-arm with top Bracket including clamp
166GI Channel X-arm including clamps and braces
16750 mm² ACSR Conductor
16811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
16911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
170Galvanized Nuts and Bolts
17111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
172Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
173Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
174Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
175Danger Plates with Clamps
176Anti-Climbing Device with Clamps
177Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
178Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
179Laying of LT for Creation of New 25 kVA at Kharhall Neel D W.No 7 (Ladrihall)
1808 Mtr. Long Pole(ST-410 SP15)
18130 mm² ACSR Conductor
18216 KN Shackle Insulator
183Galvanised M Clamp
184Galvanized Nuts and Bolts
185Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
186Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
187Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
188Danger Plates
189Anti-Climbing Device with Clamps
190Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
191Creation of new 25KVA Xmer at Upper Badla (Kumaitar)
19225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
193Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
19411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
19511 kV Horn Gap Fuse Set 3 Phase 200A
19695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
1979 Mtr. Long Pole( ST-410 SP33)
19811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
199GI Channel/Angle/Flat of sizes including clamps
200Galvinized Nuts and Bolts.
201Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
202Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
20332/63 amps TPN Switch Disconnector Fuse Unit
204Danger plates with clamps
205GI Barbed wire for Anti Climbing
206Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
207Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
208Laying of HT for Creation of new 25KVA Xmer at Upper Badla (Kumaitar)
2099 Mtr. Long Pole( ST-410 SP33)
210GI V cross-arm with top Bracket including clamp
211GI Channel X-arm including clamps and braces
21250 mm² ACSR Conductor
21311kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
21411kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
215Galvanized Nuts and Bolts
21611kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
217Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
218Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
219Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
220Danger Plates with Clamps
221Anti-Climbing Device with Clamps
222Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
223Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
224Laying of LT for Creation of New 25 kVA at Upper Badla (Kumaitar)
2258 Mtr. Long Pole(ST-410 SP15)
22630 mm² ACSR Conductor
22716 KN Shackle Insulator
228Galvanised M Clamp
229Galvanized Nuts and Bolts
230Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
231Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
232Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
233Danger Plates
234Anti-Climbing Device with Clamps
235Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
236Creation of new 25KVA Xmer at Pudlina Kutra (Karma)
23725 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
238Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
23911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
24011 kV Horn Gap Fuse Set 3 Phase 200A
24195 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
2429 Mtr. Long Pole( ST-410 SP33)
24311kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
244GI Channel/Angle/Flat of sizes including clamps
245Galvinized Nuts and Bolts.
246Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
247Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
24832/63 amps TPN Switch Disconnector Fuse Unit
249Danger plates with clamps
250GI Barbed wire for Anti Climbing
251Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
252Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
253Laying of HT for Creation of new 25KVA Xmer at Pudlina Kutra (Karma)
2549 Mtr. Long Pole( ST-410 SP33)
255GI V cross-arm with top Bracket including clamp
256GI Channel X-arm including clamps and braces
25750 mm² ACSR Conductor
25811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
25911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
260Galvanized Nuts and Bolts
26111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
262Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
263Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
264Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
265Danger Plates with Clamps
266Anti-Climbing Device with Clamps
267Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
268Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
269Laying of LT for Creation of New 25 kVA at Pudlina Kutra (Karma)
2708 Mtr. Long Pole(ST-410 SP15)
27130 mm² ACSR Conductor
27216 KN Shackle Insulator
273Galvanised M Clamp
274Galvanized Nuts and Bolts
275Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
276Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
277Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
278Danger Plates
279Anti-Climbing Device with Clamps
280Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
281Creation of new 25KVA Xmer at Nalyan W.NO 6(Sumber upper)
28225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
283Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
28411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
28511 kV Horn Gap Fuse Set 3 Phase 200A
28695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
2879 Mtr. Long Pole( ST-410 SP33)
28811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
289GI Channel/Angle/Flat of sizes including clamps
290Galvinized Nuts and Bolts.
291Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
292Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
29332/63 amps TPN Switch Disconnector Fuse Unit
294Danger plates with clamps
295GI Barbed wire for Anti Climbing
296Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
297Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
298Laying of HT for Creation of new 25KVA Xmer at Nalyan W.NO 6(Sumber upper)
2999 Mtr. Long Pole( ST-410 SP33)
300GI V cross-arm with top Bracket including clamp
301GI Channel X-arm including clamps and braces
30250 mm² ACSR Conductor
30311kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
30411kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
305Galvanized Nuts and Bolts
30611kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
307Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
308Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
309Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
310Danger Plates with Clamps
311Anti-Climbing Device with Clamps
312Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
313Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
314Laying of LT for Creation of New 25 kVA at Nalyan W.NO 6(Sumber upper)
3158 Mtr. Long Pole(ST-410 SP15)
31630 mm² ACSR Conductor
31716 KN Shackle Insulator
318Galvanised M Clamp
319Galvanized Nuts and Bolts
320Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
321Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
322Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
323Danger Plates
324Anti-Climbing Device with Clamps
325Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
326Creation of new 25KVA Xmer at Senihall Bangara
32725 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
328Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
32911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
33011 kV Horn Gap Fuse Set 3 Phase 200A
33195 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
3329 Mtr. Long Pole( ST-410 SP33)
33311kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
334GI Channel/Angle/Flat of sizes including clamps
335Galvinized Nuts and Bolts.
336Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
337Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
33832/63 amps TPN Switch Disconnector Fuse Unit
339Danger plates with clamps
340GI Barbed wire for Anti Climbing
341Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
342Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
343Laying of HT for Creation of new 25KVA Xmer at Senihall Bangara
3449 Mtr. Long Pole( ST-410 SP33)
345GI V cross-arm with top Bracket including clamp
346GI Channel X-arm including clamps and braces
34750 mm² ACSR Conductor
34811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
34911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
350Galvanized Nuts and Bolts
35111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
352Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
353Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
354Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
355Danger Plates with Clamps
356Anti-Climbing Device with Clamps
357Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
358Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
359Laying of LT for Creation of New 25 kVA at Senihall Bangara
3608 Mtr. Long Pole(ST-410 SP15)
36130 mm² ACSR Conductor
36216 KN Shackle Insulator
363Galvanised M Clamp
364Galvanized Nuts and Bolts
365Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
366Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
367Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
368Danger Plates
369Anti-Climbing Device with Clamps
370Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
371Creation of new 25KVA Xmer at Gohnihal
37225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
373Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
37411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
37511 kV Horn Gap Fuse Set 3 Phase 200A
37695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
3779 Mtr. Long Pole( ST-410 SP33)
37811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
379GI Channel/Angle/Flat of sizes including clamps
380Galvinized Nuts and Bolts.
381Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
382Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
38332/63 amps TPN Switch Disconnector Fuse Unit
384Danger plates with clamps
385GI Barbed wire for Anti Climbing
386Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
387Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
388Laying of HT for Creation of new 25KVA Xmer at Gohnihal
3899 Mtr. Long Pole( ST-410 SP33)
390GI V cross-arm with top Bracket including clamp
391GI Channel X-arm including clamps and braces
39250 mm² ACSR Conductor
39311kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
39411kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
395Galvanized Nuts and Bolts
39611kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
397Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
398Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
399Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
400Danger Plates with Clamps
401Anti-Climbing Device with Clamps
402Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
403Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
404Laying of LT for Creation of New 25 kVA at Gohnihal
4058 Mtr. Long Pole(ST-410 SP15)
40630 mm² ACSR Conductor
40716 KN Shackle Insulator
408Galvanised M Clamp
409Galvanized Nuts and Bolts
410Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
411Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
412Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
413Danger Plates
414Anti-Climbing Device with Clamps
415Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
416Creation of new 25KVA Xmer at Beakh Phagmulla
41725 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
418Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
41911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
42011 kV Horn Gap Fuse Set 3 Phase 200A
42195 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
4229 Mtr. Long Pole( ST-410 SP33)
42311kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
424GI Channel/Angle/Flat of sizes including clamps
425Galvinized Nuts and Bolts.
426Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
427Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
42832/63 amps TPN Switch Disconnector Fuse Unit
429Danger plates with clamps
430GI Barbed wire for Anti Climbing
431Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
432Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
433Laying of HT for Creation of new 25KVA Xmer at Beakh Phagmulla
4349 Mtr. Long Pole( ST-410 SP33)
435GI V cross-arm with top Bracket including clamp
436GI Channel X-arm including clamps and braces
43750 mm² ACSR Conductor
43811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
43911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
440Galvanized Nuts and Bolts
44111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
442Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
443Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
444Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
445Danger Plates with Clamps
446Anti-Climbing Device with Clamps
447Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
448Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
449Laying of LT for Creation of New 25 kVA at Beakh Phagmulla
4508 Mtr. Long Pole(ST-410 SP15)
45130 mm² ACSR Conductor
45216 KN Shackle Insulator
453Galvanised M Clamp
454Galvanized Nuts and Bolts
455Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
456Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
457Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
458Danger Plates
459Anti-Climbing Device with Clamps
460Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
461Creation of new 25KVA Xmer at Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla
46225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
463Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
46411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
46511 kV Horn Gap Fuse Set 3 Phase 200A
46695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
4679 Mtr. Long Pole( ST-410 SP33)
46811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
469GI Channel/Angle/Flat of sizes including clamps
470Galvinized Nuts and Bolts.
471Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
472Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
47332/63 amps TPN Switch Disconnector Fuse Unit
474Danger plates with clamps
475GI Barbed wire for Anti Climbing
476Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
477Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
478Laying of HT for Creation of new 25KVA Xmer at Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla
4799 Mtr. Long Pole( ST-410 SP33)
480GI V cross-arm with top Bracket including clamp
481GI Channel X-arm including clamps and braces
48250 mm² ACSR Conductor
48311kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
48411kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
485Galvanized Nuts and Bolts
48611kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
487Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
488Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
489Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
490Danger Plates with Clamps
491Anti-Climbing Device with Clamps
492Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
493Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
494Laying of LT for Creation of New 25 kVA at Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla
4958 Mtr. Long Pole(ST-410 SP15)
49630 mm² ACSR Conductor
49716 KN Shackle Insulator
498Galvanised M Clamp
499Galvanized Nuts and Bolts
500Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
501Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
502Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
503Danger Plates
504Anti-Climbing Device with Clamps
505Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
506Creation of new 25KVA Xmer at W.No. 4 Mutlal (Alinbasss B)
50725 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
508Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
50911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
51011 kV Horn Gap Fuse Set 3 Phase 200A
51195 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
5129 Mtr. Long Pole( ST-410 SP33)
51311kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
514GI Channel/Angle/Flat of sizes including clamps
515Galvinized Nuts and Bolts.
516Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
517Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
51832/63 amps TPN Switch Disconnector Fuse Unit
519Danger plates with clamps
520GI Barbed wire for Anti Climbing
521Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
522Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
523Laying of HT for Creation of new 25KVA Xmer at W.No. 4 Mutlal (Alinbasss B)
5249 Mtr. Long Pole( ST-410 SP33)
525GI V cross-arm with top Bracket including clamp
526GI Channel X-arm including clamps and braces
52750 mm² ACSR Conductor
52811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
52911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
530Galvanized Nuts and Bolts
53111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
532Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
533Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
534Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
535Danger Plates with Clamps
536Anti-Climbing Device with Clamps
537Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
538Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
539Laying of LT for Creation of New 25 kVA at W.No. 4 Mutlal (Alinbasss B)
5408 Mtr. Long Pole(ST-410 SP15)
54130 mm² ACSR Conductor
54216 KN Shackle Insulator
543Galvanised M Clamp
544Galvanized Nuts and Bolts
545Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
546Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
547Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
548Danger Plates
549Anti-Climbing Device with Clamps
550Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
551Creation of new 25KVA Xmer at Charna (Ganote)
55225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
553Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
55411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
55511 kV Horn Gap Fuse Set 3 Phase 200A
55695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
5579 Mtr. Long Pole( ST-410 SP33)
55811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
559GI Channel/Angle/Flat of sizes including clamps
560Galvinized Nuts and Bolts.
561Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
562Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
56332/63 amps TPN Switch Disconnector Fuse Unit
564Danger plates with clamps
565GI Barbed wire for Anti Climbing
566Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
567Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
568Laying of HT for Creation of new 25KVA Xmer at Charna (Ganote)
5699 Mtr. Long Pole( ST-410 SP33)
570GI V cross-arm with top Bracket including clamp
571GI Channel X-arm including clamps and braces
57250 mm² ACSR Conductor
57311kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
57411kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
575Galvanized Nuts and Bolts
57611kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
577Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
578Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
579Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
580Danger Plates with Clamps
581Anti-Climbing Device with Clamps
582Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
583Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
584Laying of LT for Creation of New 25 kVA at Charna (Ganote)
5858 Mtr. Long Pole(ST-410 SP15)
58630 mm² ACSR Conductor
58716 KN Shackle Insulator
588Galvanised M Clamp
589Galvanized Nuts and Bolts
590Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
591Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
592Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
593Danger Plates
594Anti-Climbing Device with Clamps
595Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
596Creation of new 25KVA Xmer at Imnari Pogal Paristan (Rayisabad)
59725 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
598Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
59911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
60011 kV Horn Gap Fuse Set 3 Phase 200A
60195 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
6029 Mtr. Long Pole( ST-410 SP33)
60311kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
604GI Channel/Angle/Flat of sizes including clamps
605Galvinized Nuts and Bolts.
606Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
607Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
60832/63 amps TPN Switch Disconnector Fuse Unit
609Danger plates with clamps
610GI Barbed wire for Anti Climbing
611Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
612Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
613Laying of HT for Creation of new 25KVA Xmer at Imnari Pogal Paristan (Rayisabad)
6149 Mtr. Long Pole( ST-410 SP33)
615GI V cross-arm with top Bracket including clamp
616GI Channel X-arm including clamps and braces
61750 mm² ACSR Conductor
61811kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
61911kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
620Galvanized Nuts and Bolts
62111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
622Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
623Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
624Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
625Danger Plates with Clamps
626Anti-Climbing Device with Clamps
627Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
628Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
629Laying of LT for Creation of New 25 kVA at Imnari Pogal Paristan (Rayisabad)
6308 Mtr. Long Pole(ST-410 SP15)
63130 mm² ACSR Conductor
63216 KN Shackle Insulator
633Galvanised M Clamp
634Galvanized Nuts and Bolts
635Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
636Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
637Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
638Danger Plates
639Anti-Climbing Device with Clamps
640Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
641Laying of HT line at ST Basti Tanka Ward no 10 village Upper Trigam
6429 Mtr. Long Pole( ST-410 SP33)
643GI V cross-arm with top Bracket including clamp
644GI Channel X-arm including clamps and braces
64550 mm² ACSR Conductor
64611kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
64711kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
648Galvanized Nuts and Bolts
64911kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
650Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
651Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
652Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
653Danger Plates with Clamps
654Anti-Climbing Device with Clamps
655Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole
656Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
657Laying of LT at ST Basti Tanka Ward no 10 village Upper Trigam
6588 Mtr. Long Pole(ST-410 SP15)
65930 mm² ACSR Conductor
66016 KN Shackle Insulator
661Galvanised M Clamp
662Galvanized Nuts and Bolts
663Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
664Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
665Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
666Danger Plates
667Anti-Climbing Device with Clamps
668Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
669Laying of LT at Dhar, Larna, Darzangal
6708 Mtr. Long Pole(ST-410 SP15)
67130 mm² ACSR Conductor
67216 KN Shackle Insulator
673Galvanised M Clamp
674Galvanized Nuts and Bolts
675Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
676Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
677Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
678Danger Plates
679Anti-Climbing Device with Clamps
680Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole
681Creation of new 25KVA Xmer at W.No.5 (Upper Halla, Urendhar, Kadro) village Dhundhrath C
68225 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment
683Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
68411kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
68511 kV Horn Gap Fuse Set 3 Phase 200A
68695 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
6879 Mtr. Long Pole( ST-410 SP33)
68811kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
689GI Channel/Angle/Flat of sizes including clamps
690Galvinized Nuts and Bolts.
691Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
692Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
69332/63 amps TPN Switch Disconnector Fuse Unit
694Danger plates with clamps
695GI Barbed wire for Anti Climbing
696Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
697Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
698Laying of LT for 25KVA Xmer at W.No.5 (Upper Halla, Urendhar, Kadro) village Dhundhrath C
6998 Mtr. Long Pole(ST-410 SP15)
70030 mm² ACSR Conductor
70116 KN Shackle Insulator
702Galvanised M Clamp
703Galvanized Nuts and Bolts
704Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
705Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make)
706Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make)
707Danger Plates
708Anti-Climbing Device with Clamps
709Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57978501
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 02-11-2026
Authority
Authority Name Power Development Department
Work Description Tender for Supply, Survey, Erection, Testing And Commissioning Including Laying Of Lt/Ht After Creation Of 12 Nos 25 Kva Substation At Varnall-Ii (Sarwagani-A), Kharhall Neel D W.No 7 (Ladrihall), Upper Badla (Kumaitar), Pudlina Kutra (Karma), Nalyan W.No 6(Sumber Upper), Senihall Bangara, Gohnihal, Beakh Phagmulla, Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla, W.No. 4 Mutlal (Alinbasss B),Charna (Ganote), Imnari Pogal Paristan (Rayisabad) And 2 Nos 63 Kva Sub Stns At Varnal Audik (Sarwagni A) & Bajuni Upper W.No 1,4(Sumber Upper) And Ht/Lt Only For St Basti Tanka Ward No 10, W.No 5, Upper Halla, Urendhar, Kadro (Dhundrath B) And Dhar, Larna, Darzangal (Dhundrath C) For Electrification Of Unelectrified Households Of Ukhral Ramsoo Ramban And Gool Blocks Of Ramban District Under The Jurisdiction Of Ed Jpdcl Batote (Scheme Code Pddss2425100377)
Basic Detail
Tender No eNIT 30 of 2026-27
Bidding Type Tender
Location
City Doda
State Jammu and Kashmir
Key Dates
Publish Date 12 Oct 2026
Submission Date 02 Nov 2026
Open Date 03 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 6.84 Lakhs
Exemption Not Available
Document List
BOQ_1109488.xls
f270b86f-2a95-4644-8e82-70960a7a33c3.html
SBD30pdf.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1109488.xls

html

f270b86f-2a95-4644-8e82-70960a7a33c3.html

pdf

SBD30pdf.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender