Tender For Supply, Survey, Erection, Testing And Commissioning Including Laying Of Lt/Ht After Creation Of 12 Nos 25 Kva Substation At Varnall-Ii (Sarwagani-A), Kharhall Neel D W.No 7 (Ladrihall), Upper Badla (Kumaitar), Pudlina Kutra (Karma), Nalyan
Tender Overview
Project Description
Tender for Supply, Survey, Erection, Testing And Commissioning Including Laying Of Lt/Ht After Creation Of 12 Nos 25 Kva Substation At Varnall-Ii (Sarwagani-A), Kharhall Neel D W.No 7 (Ladrihall), Upper Badla (Kumaitar), Pudlina Kutra (Karma), Nalyan W.No 6(Sumber Upper), Senihall Bangara, Gohnihal, Beakh Phagmulla, Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla, W.No. 4 Mutlal (Alinbasss B),Charna (Ganote), Imnari Pogal Paristan (Rayisabad) And 2 Nos 63 Kva Sub Stns At Varnal Audik (Sarwagni A) & Bajuni Upper W.No 1,4(Sumber Upper) And Ht/Lt Only For St Basti Tanka Ward No 10, W.No 5, Upper Halla, Urendhar, Kadro (Dhundrath B) And Dhar, Larna, Darzangal (Dhundrath C) For Electrification Of Unelectrified Households Of Ukhral Ramsoo Ramban And Gool Blocks Of Ramban District Under The Jurisdiction Of Ed Jpdcl Batote (Scheme Code Pddss2425100377)
BOQ
| Sl. No. | Item Description |
| 1 | Creation of New 63kVA Xmer at Varnall Audik village Sarwagmi A |
| 2 | 63 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings |
| 3 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 4 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 5 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 6 | 120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type |
| 7 | 9 Mtr. Long Pole( ST-410 SP33) |
| 8 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | GI Channel/Angle/Flat of sizes including clamps |
| 10 | Galvinized Nuts and Bolts. |
| 11 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 12 | 11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm |
| 13 | Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete. |
| 14 | Wedge connctors/PG Clamps |
| 15 | Danger plates with clamps |
| 16 | GI Barbed wire for Anti Climbing |
| 17 | 3-phase 4 wire Trivector meter with CT |
| 18 | Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole |
| 19 | LT Distribution Box for 63 kVA DTR with MCCB forincomer & Switch Fuse Units for Outgoing Circuits |
| 20 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 21 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 22 | Sundry Item like aluminium lugs, jumpers, binding tape. |
| 23 | Laying of HT for Creation of New 63kVA Xmer Varnall Audik village Sarwagmi A |
| 24 | 9 Mtr. Long Pole( ST-410 SP33) |
| 25 | GI V cross-arm with top Bracket including clamp |
| 26 | GI Channel X-arm including clamps and braces |
| 27 | 50 mm² ACSR Conductor |
| 28 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 29 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 30 | Galvanized Nuts and Bolts |
| 31 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 32 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 33 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 34 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 35 | Danger Plates with Clamps |
| 36 | Anti-Climbing Device with Clamps |
| 37 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 38 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 39 | Laying of LT for Creation of New 63kVA Xmer Varnall Audik village Sarwagmi A |
| 40 | 8 Mtr. Long Pole(ST-410 SP15) |
| 41 | 30 mm² ACSR Conductor |
| 42 | 16 KN Shackle Insulator |
| 43 | Galvanised M Clamp |
| 44 | Galvanized Nuts and Bolts |
| 45 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 46 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 47 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 48 | Danger Plates |
| 49 | Anti-Climbing Device with Clamps |
| 50 | Cement bottoming 1:2:4 mix as per REC standards.45cum /pole |
| 51 | Creation of New 63kVA Xmer at Bajuni Upper W.No 1,4(Sumber Upper) |
| 52 | 63 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings |
| 53 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 54 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 55 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 56 | 120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type |
| 57 | 9 Mtr. Long Pole( ST-410 SP33) |
| 58 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 59 | GI Channel/Angle/Flat of sizes including clamps |
| 60 | Galvinized Nuts and Bolts. |
| 61 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 62 | 11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm |
| 63 | Galvanized stay set with 50*8 mm stay clamp, guy insulator(2 nos), anchor plate (200*6mm), nuts-bolts, 2 Nos turn buckets, 1.8m long, 16 mm diameter solid GS stay rod & 7/15 mm dia GI strandard wire complete. |
| 64 | Wedge connctors/PG Clamps |
| 65 | Danger plates with clamps |
| 66 | GI Barbed wire for Anti Climbing |
| 67 | 3-phase 4 wire Trivector meter with CT |
| 68 | Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole |
| 69 | LT Distribution Box for 63 kVA DTR with MCCB forincomer & Switch Fuse Units for Outgoing Circuits |
| 70 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 71 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 72 | Sundry Item like aluminium lugs, jumpers, binding tape. |
| 73 | Laying of HT for Creation of New 63kVA Xmer at Bajuni Upper W.No 1,4(Sumber Upper) |
| 74 | 9 Mtr. Long Pole( ST-410 SP33) |
| 75 | GI V cross-arm with top Bracket including clamp |
| 76 | GI Channel X-arm including clamps and braces |
| 77 | 50 mm² ACSR Conductor |
| 78 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 79 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 80 | Galvanized Nuts and Bolts |
| 81 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 82 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 83 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 84 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 85 | Danger Plates with Clamps |
| 86 | Anti-Climbing Device with Clamps |
| 87 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 88 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 89 | Laying of LT for Creation of New 63kVA at Bajuni Upper W.No 1,4(Sumber Upper) |
| 90 | 8 Mtr. Long Pole(ST-410 SP15) |
| 91 | 30 mm² ACSR Conductor |
| 92 | 16 KN Shackle Insulator |
| 93 | Galvanised M Clamp |
| 94 | Galvanized Nuts and Bolts |
| 95 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 96 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 97 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 98 | Danger Plates |
| 99 | Anti-Climbing Device with Clamps |
| 100 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 101 | Creation of new 25KVA Xmer at at Varnall -II village Sarwagni A |
| 102 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 103 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 104 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 105 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 106 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 107 | 9 Mtr. Long Pole( ST-410 SP33) |
| 108 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 109 | GI Channel/Angle/Flat of sizes including clamps |
| 110 | Galvinized Nuts and Bolts. |
| 111 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 112 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 113 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 114 | Danger plates with clamps |
| 115 | GI Barbed wire for Anti Climbing |
| 116 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 117 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 118 | Laying of HT for Creation of new 25KVA Xmer at at Varnall -II village Sarwagni A |
| 119 | 9 Mtr. Long Pole( ST-410 SP33) |
| 120 | GI V cross-arm with top Bracket including clamp |
| 121 | GI Channel X-arm including clamps and braces |
| 122 | 50 mm² ACSR Conductor |
| 123 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 124 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 125 | Galvanized Nuts and Bolts |
| 126 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 127 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 128 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 129 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 130 | Danger Plates with Clamps |
| 131 | Anti-Climbing Device with Clamps |
| 132 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 133 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 134 | Laying of LT for Creation of New 25KVA Xmer at at Varnall -II village Sarwagni A |
| 135 | 8 Mtr. Long Pole(ST-410 SP15) |
| 136 | 30 mm² ACSR Conductor |
| 137 | 16 KN Shackle Insulator |
| 138 | Galvanised M Clamp |
| 139 | Galvanized Nuts and Bolts |
| 140 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 141 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 142 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 143 | Danger Plates |
| 144 | Anti-Climbing Device with Clamps |
| 145 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 146 | Creation of new 25KVA Xmer at Kharhall Neel D W.No 7 (Ladrihall) |
| 147 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 148 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 149 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 150 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 151 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 152 | 9 Mtr. Long Pole( ST-410 SP33) |
| 153 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 154 | GI Channel/Angle/Flat of sizes including clamps |
| 155 | Galvinized Nuts and Bolts. |
| 156 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 157 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 158 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 159 | Danger plates with clamps |
| 160 | GI Barbed wire for Anti Climbing |
| 161 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 162 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 163 | Laying of HT for Creation of new 25KVA Xmer at Kharhall Neel D W.No 7 (Ladrihall) |
| 164 | 9 Mtr. Long Pole( ST-410 SP33) |
| 165 | GI V cross-arm with top Bracket including clamp |
| 166 | GI Channel X-arm including clamps and braces |
| 167 | 50 mm² ACSR Conductor |
| 168 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 169 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 170 | Galvanized Nuts and Bolts |
| 171 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 172 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 173 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 174 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 175 | Danger Plates with Clamps |
| 176 | Anti-Climbing Device with Clamps |
| 177 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 178 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 179 | Laying of LT for Creation of New 25 kVA at Kharhall Neel D W.No 7 (Ladrihall) |
| 180 | 8 Mtr. Long Pole(ST-410 SP15) |
| 181 | 30 mm² ACSR Conductor |
| 182 | 16 KN Shackle Insulator |
| 183 | Galvanised M Clamp |
| 184 | Galvanized Nuts and Bolts |
| 185 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 186 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 187 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 188 | Danger Plates |
| 189 | Anti-Climbing Device with Clamps |
| 190 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 191 | Creation of new 25KVA Xmer at Upper Badla (Kumaitar) |
| 192 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 193 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 194 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 195 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 196 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 197 | 9 Mtr. Long Pole( ST-410 SP33) |
| 198 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 199 | GI Channel/Angle/Flat of sizes including clamps |
| 200 | Galvinized Nuts and Bolts. |
| 201 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 202 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 203 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 204 | Danger plates with clamps |
| 205 | GI Barbed wire for Anti Climbing |
| 206 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 207 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 208 | Laying of HT for Creation of new 25KVA Xmer at Upper Badla (Kumaitar) |
| 209 | 9 Mtr. Long Pole( ST-410 SP33) |
| 210 | GI V cross-arm with top Bracket including clamp |
| 211 | GI Channel X-arm including clamps and braces |
| 212 | 50 mm² ACSR Conductor |
| 213 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 214 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 215 | Galvanized Nuts and Bolts |
| 216 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 217 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 218 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 219 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 220 | Danger Plates with Clamps |
| 221 | Anti-Climbing Device with Clamps |
| 222 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 223 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 224 | Laying of LT for Creation of New 25 kVA at Upper Badla (Kumaitar) |
| 225 | 8 Mtr. Long Pole(ST-410 SP15) |
| 226 | 30 mm² ACSR Conductor |
| 227 | 16 KN Shackle Insulator |
| 228 | Galvanised M Clamp |
| 229 | Galvanized Nuts and Bolts |
| 230 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 231 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 232 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 233 | Danger Plates |
| 234 | Anti-Climbing Device with Clamps |
| 235 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 236 | Creation of new 25KVA Xmer at Pudlina Kutra (Karma) |
| 237 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 238 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 239 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 240 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 241 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 242 | 9 Mtr. Long Pole( ST-410 SP33) |
| 243 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 244 | GI Channel/Angle/Flat of sizes including clamps |
| 245 | Galvinized Nuts and Bolts. |
| 246 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 247 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 248 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 249 | Danger plates with clamps |
| 250 | GI Barbed wire for Anti Climbing |
| 251 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 252 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 253 | Laying of HT for Creation of new 25KVA Xmer at Pudlina Kutra (Karma) |
| 254 | 9 Mtr. Long Pole( ST-410 SP33) |
| 255 | GI V cross-arm with top Bracket including clamp |
| 256 | GI Channel X-arm including clamps and braces |
| 257 | 50 mm² ACSR Conductor |
| 258 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 259 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 260 | Galvanized Nuts and Bolts |
| 261 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 262 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 263 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 264 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 265 | Danger Plates with Clamps |
| 266 | Anti-Climbing Device with Clamps |
| 267 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 268 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 269 | Laying of LT for Creation of New 25 kVA at Pudlina Kutra (Karma) |
| 270 | 8 Mtr. Long Pole(ST-410 SP15) |
| 271 | 30 mm² ACSR Conductor |
| 272 | 16 KN Shackle Insulator |
| 273 | Galvanised M Clamp |
| 274 | Galvanized Nuts and Bolts |
| 275 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 276 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 277 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 278 | Danger Plates |
| 279 | Anti-Climbing Device with Clamps |
| 280 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 281 | Creation of new 25KVA Xmer at Nalyan W.NO 6(Sumber upper) |
| 282 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 283 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 284 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 285 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 286 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 287 | 9 Mtr. Long Pole( ST-410 SP33) |
| 288 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 289 | GI Channel/Angle/Flat of sizes including clamps |
| 290 | Galvinized Nuts and Bolts. |
| 291 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 292 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 293 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 294 | Danger plates with clamps |
| 295 | GI Barbed wire for Anti Climbing |
| 296 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 297 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 298 | Laying of HT for Creation of new 25KVA Xmer at Nalyan W.NO 6(Sumber upper) |
| 299 | 9 Mtr. Long Pole( ST-410 SP33) |
| 300 | GI V cross-arm with top Bracket including clamp |
| 301 | GI Channel X-arm including clamps and braces |
| 302 | 50 mm² ACSR Conductor |
| 303 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 304 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 305 | Galvanized Nuts and Bolts |
| 306 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 307 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 308 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 309 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 310 | Danger Plates with Clamps |
| 311 | Anti-Climbing Device with Clamps |
| 312 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 313 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 314 | Laying of LT for Creation of New 25 kVA at Nalyan W.NO 6(Sumber upper) |
| 315 | 8 Mtr. Long Pole(ST-410 SP15) |
| 316 | 30 mm² ACSR Conductor |
| 317 | 16 KN Shackle Insulator |
| 318 | Galvanised M Clamp |
| 319 | Galvanized Nuts and Bolts |
| 320 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 321 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 322 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 323 | Danger Plates |
| 324 | Anti-Climbing Device with Clamps |
| 325 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 326 | Creation of new 25KVA Xmer at Senihall Bangara |
| 327 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 328 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 329 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 330 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 331 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 332 | 9 Mtr. Long Pole( ST-410 SP33) |
| 333 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 334 | GI Channel/Angle/Flat of sizes including clamps |
| 335 | Galvinized Nuts and Bolts. |
| 336 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 337 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 338 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 339 | Danger plates with clamps |
| 340 | GI Barbed wire for Anti Climbing |
| 341 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 342 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 343 | Laying of HT for Creation of new 25KVA Xmer at Senihall Bangara |
| 344 | 9 Mtr. Long Pole( ST-410 SP33) |
| 345 | GI V cross-arm with top Bracket including clamp |
| 346 | GI Channel X-arm including clamps and braces |
| 347 | 50 mm² ACSR Conductor |
| 348 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 349 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 350 | Galvanized Nuts and Bolts |
| 351 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 352 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 353 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 354 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 355 | Danger Plates with Clamps |
| 356 | Anti-Climbing Device with Clamps |
| 357 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 358 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 359 | Laying of LT for Creation of New 25 kVA at Senihall Bangara |
| 360 | 8 Mtr. Long Pole(ST-410 SP15) |
| 361 | 30 mm² ACSR Conductor |
| 362 | 16 KN Shackle Insulator |
| 363 | Galvanised M Clamp |
| 364 | Galvanized Nuts and Bolts |
| 365 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 366 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 367 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 368 | Danger Plates |
| 369 | Anti-Climbing Device with Clamps |
| 370 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 371 | Creation of new 25KVA Xmer at Gohnihal |
| 372 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 373 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 374 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 375 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 376 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 377 | 9 Mtr. Long Pole( ST-410 SP33) |
| 378 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 379 | GI Channel/Angle/Flat of sizes including clamps |
| 380 | Galvinized Nuts and Bolts. |
| 381 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 382 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 383 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 384 | Danger plates with clamps |
| 385 | GI Barbed wire for Anti Climbing |
| 386 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 387 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 388 | Laying of HT for Creation of new 25KVA Xmer at Gohnihal |
| 389 | 9 Mtr. Long Pole( ST-410 SP33) |
| 390 | GI V cross-arm with top Bracket including clamp |
| 391 | GI Channel X-arm including clamps and braces |
| 392 | 50 mm² ACSR Conductor |
| 393 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 394 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 395 | Galvanized Nuts and Bolts |
| 396 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 397 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 398 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 399 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 400 | Danger Plates with Clamps |
| 401 | Anti-Climbing Device with Clamps |
| 402 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 403 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 404 | Laying of LT for Creation of New 25 kVA at Gohnihal |
| 405 | 8 Mtr. Long Pole(ST-410 SP15) |
| 406 | 30 mm² ACSR Conductor |
| 407 | 16 KN Shackle Insulator |
| 408 | Galvanised M Clamp |
| 409 | Galvanized Nuts and Bolts |
| 410 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 411 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 412 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 413 | Danger Plates |
| 414 | Anti-Climbing Device with Clamps |
| 415 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 416 | Creation of new 25KVA Xmer at Beakh Phagmulla |
| 417 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 418 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 419 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 420 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 421 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 422 | 9 Mtr. Long Pole( ST-410 SP33) |
| 423 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 424 | GI Channel/Angle/Flat of sizes including clamps |
| 425 | Galvinized Nuts and Bolts. |
| 426 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 427 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 428 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 429 | Danger plates with clamps |
| 430 | GI Barbed wire for Anti Climbing |
| 431 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 432 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 433 | Laying of HT for Creation of new 25KVA Xmer at Beakh Phagmulla |
| 434 | 9 Mtr. Long Pole( ST-410 SP33) |
| 435 | GI V cross-arm with top Bracket including clamp |
| 436 | GI Channel X-arm including clamps and braces |
| 437 | 50 mm² ACSR Conductor |
| 438 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 439 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 440 | Galvanized Nuts and Bolts |
| 441 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 442 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 443 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 444 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 445 | Danger Plates with Clamps |
| 446 | Anti-Climbing Device with Clamps |
| 447 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 448 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 449 | Laying of LT for Creation of New 25 kVA at Beakh Phagmulla |
| 450 | 8 Mtr. Long Pole(ST-410 SP15) |
| 451 | 30 mm² ACSR Conductor |
| 452 | 16 KN Shackle Insulator |
| 453 | Galvanised M Clamp |
| 454 | Galvanized Nuts and Bolts |
| 455 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 456 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 457 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 458 | Danger Plates |
| 459 | Anti-Climbing Device with Clamps |
| 460 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 461 | Creation of new 25KVA Xmer at Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla |
| 462 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 463 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 464 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 465 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 466 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 467 | 9 Mtr. Long Pole( ST-410 SP33) |
| 468 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 469 | GI Channel/Angle/Flat of sizes including clamps |
| 470 | Galvinized Nuts and Bolts. |
| 471 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 472 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 473 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 474 | Danger plates with clamps |
| 475 | GI Barbed wire for Anti Climbing |
| 476 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 477 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 478 | Laying of HT for Creation of new 25KVA Xmer at Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla |
| 479 | 9 Mtr. Long Pole( ST-410 SP33) |
| 480 | GI V cross-arm with top Bracket including clamp |
| 481 | GI Channel X-arm including clamps and braces |
| 482 | 50 mm² ACSR Conductor |
| 483 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 484 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 485 | Galvanized Nuts and Bolts |
| 486 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 487 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 488 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 489 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 490 | Danger Plates with Clamps |
| 491 | Anti-Climbing Device with Clamps |
| 492 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 493 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 494 | Laying of LT for Creation of New 25 kVA at Hajam Mohalla Upper Bhatti/ Nainsukh Mohalla |
| 495 | 8 Mtr. Long Pole(ST-410 SP15) |
| 496 | 30 mm² ACSR Conductor |
| 497 | 16 KN Shackle Insulator |
| 498 | Galvanised M Clamp |
| 499 | Galvanized Nuts and Bolts |
| 500 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 501 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 502 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 503 | Danger Plates |
| 504 | Anti-Climbing Device with Clamps |
| 505 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 506 | Creation of new 25KVA Xmer at W.No. 4 Mutlal (Alinbasss B) |
| 507 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 508 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 509 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 510 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 511 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 512 | 9 Mtr. Long Pole( ST-410 SP33) |
| 513 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 514 | GI Channel/Angle/Flat of sizes including clamps |
| 515 | Galvinized Nuts and Bolts. |
| 516 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 517 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 518 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 519 | Danger plates with clamps |
| 520 | GI Barbed wire for Anti Climbing |
| 521 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 522 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 523 | Laying of HT for Creation of new 25KVA Xmer at W.No. 4 Mutlal (Alinbasss B) |
| 524 | 9 Mtr. Long Pole( ST-410 SP33) |
| 525 | GI V cross-arm with top Bracket including clamp |
| 526 | GI Channel X-arm including clamps and braces |
| 527 | 50 mm² ACSR Conductor |
| 528 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 529 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 530 | Galvanized Nuts and Bolts |
| 531 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 532 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 533 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 534 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 535 | Danger Plates with Clamps |
| 536 | Anti-Climbing Device with Clamps |
| 537 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 538 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 539 | Laying of LT for Creation of New 25 kVA at W.No. 4 Mutlal (Alinbasss B) |
| 540 | 8 Mtr. Long Pole(ST-410 SP15) |
| 541 | 30 mm² ACSR Conductor |
| 542 | 16 KN Shackle Insulator |
| 543 | Galvanised M Clamp |
| 544 | Galvanized Nuts and Bolts |
| 545 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 546 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 547 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 548 | Danger Plates |
| 549 | Anti-Climbing Device with Clamps |
| 550 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 551 | Creation of new 25KVA Xmer at Charna (Ganote) |
| 552 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 553 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 554 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 555 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 556 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 557 | 9 Mtr. Long Pole( ST-410 SP33) |
| 558 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 559 | GI Channel/Angle/Flat of sizes including clamps |
| 560 | Galvinized Nuts and Bolts. |
| 561 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 562 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 563 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 564 | Danger plates with clamps |
| 565 | GI Barbed wire for Anti Climbing |
| 566 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 567 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 568 | Laying of HT for Creation of new 25KVA Xmer at Charna (Ganote) |
| 569 | 9 Mtr. Long Pole( ST-410 SP33) |
| 570 | GI V cross-arm with top Bracket including clamp |
| 571 | GI Channel X-arm including clamps and braces |
| 572 | 50 mm² ACSR Conductor |
| 573 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 574 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 575 | Galvanized Nuts and Bolts |
| 576 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 577 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 578 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 579 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 580 | Danger Plates with Clamps |
| 581 | Anti-Climbing Device with Clamps |
| 582 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 583 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 584 | Laying of LT for Creation of New 25 kVA at Charna (Ganote) |
| 585 | 8 Mtr. Long Pole(ST-410 SP15) |
| 586 | 30 mm² ACSR Conductor |
| 587 | 16 KN Shackle Insulator |
| 588 | Galvanised M Clamp |
| 589 | Galvanized Nuts and Bolts |
| 590 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 591 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 592 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 593 | Danger Plates |
| 594 | Anti-Climbing Device with Clamps |
| 595 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 596 | Creation of new 25KVA Xmer at Imnari Pogal Paristan (Rayisabad) |
| 597 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 598 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 599 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 600 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 601 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 602 | 9 Mtr. Long Pole( ST-410 SP33) |
| 603 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 604 | GI Channel/Angle/Flat of sizes including clamps |
| 605 | Galvinized Nuts and Bolts. |
| 606 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 607 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 608 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 609 | Danger plates with clamps |
| 610 | GI Barbed wire for Anti Climbing |
| 611 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 612 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 613 | Laying of HT for Creation of new 25KVA Xmer at Imnari Pogal Paristan (Rayisabad) |
| 614 | 9 Mtr. Long Pole( ST-410 SP33) |
| 615 | GI V cross-arm with top Bracket including clamp |
| 616 | GI Channel X-arm including clamps and braces |
| 617 | 50 mm² ACSR Conductor |
| 618 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 619 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 620 | Galvanized Nuts and Bolts |
| 621 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 622 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 623 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 624 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 625 | Danger Plates with Clamps |
| 626 | Anti-Climbing Device with Clamps |
| 627 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 628 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 629 | Laying of LT for Creation of New 25 kVA at Imnari Pogal Paristan (Rayisabad) |
| 630 | 8 Mtr. Long Pole(ST-410 SP15) |
| 631 | 30 mm² ACSR Conductor |
| 632 | 16 KN Shackle Insulator |
| 633 | Galvanised M Clamp |
| 634 | Galvanized Nuts and Bolts |
| 635 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 636 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 637 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 638 | Danger Plates |
| 639 | Anti-Climbing Device with Clamps |
| 640 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 641 | Laying of HT line at ST Basti Tanka Ward no 10 village Upper Trigam |
| 642 | 9 Mtr. Long Pole( ST-410 SP33) |
| 643 | GI V cross-arm with top Bracket including clamp |
| 644 | GI Channel X-arm including clamps and braces |
| 645 | 50 mm² ACSR Conductor |
| 646 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 647 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 648 | Galvanized Nuts and Bolts |
| 649 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 650 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 651 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 652 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 653 | Danger Plates with Clamps |
| 654 | Anti-Climbing Device with Clamps |
| 655 | Cement bottoming 1:2:4 mix as per REC standards 0.5 cum per pole |
| 656 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 657 | Laying of LT at ST Basti Tanka Ward no 10 village Upper Trigam |
| 658 | 8 Mtr. Long Pole(ST-410 SP15) |
| 659 | 30 mm² ACSR Conductor |
| 660 | 16 KN Shackle Insulator |
| 661 | Galvanised M Clamp |
| 662 | Galvanized Nuts and Bolts |
| 663 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 664 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 665 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 666 | Danger Plates |
| 667 | Anti-Climbing Device with Clamps |
| 668 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 669 | Laying of LT at Dhar, Larna, Darzangal |
| 670 | 8 Mtr. Long Pole(ST-410 SP15) |
| 671 | 30 mm² ACSR Conductor |
| 672 | 16 KN Shackle Insulator |
| 673 | Galvanised M Clamp |
| 674 | Galvanized Nuts and Bolts |
| 675 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 676 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 677 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 678 | Danger Plates |
| 679 | Anti-Climbing Device with Clamps |
| 680 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole |
| 681 | Creation of new 25KVA Xmer at W.No.5 (Upper Halla, Urendhar, Kadro) village Dhundhrath C |
| 682 | 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment |
| 683 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 684 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical |
| 685 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 686 | 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 687 | 9 Mtr. Long Pole( ST-410 SP33) |
| 688 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 689 | GI Channel/Angle/Flat of sizes including clamps |
| 690 | Galvinized Nuts and Bolts. |
| 691 | Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole |
| 692 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 693 | 32/63 amps TPN Switch Disconnector Fuse Unit |
| 694 | Danger plates with clamps |
| 695 | GI Barbed wire for Anti Climbing |
| 696 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 697 | Painting of ST poles 9 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 698 | Laying of LT for 25KVA Xmer at W.No.5 (Upper Halla, Urendhar, Kadro) village Dhundhrath C |
| 699 | 8 Mtr. Long Pole(ST-410 SP15) |
| 700 | 30 mm² ACSR Conductor |
| 701 | 16 KN Shackle Insulator |
| 702 | Galvanised M Clamp |
| 703 | Galvanized Nuts and Bolts |
| 704 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 705 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 1 coat of Red Oxide (Asian/Nerolac make) |
| 706 | Painting of ST poles 8 mtr of substation including cross arm, clamps with 2 coat of Aluminium Paint (Asian/Nerolac make) |
| 707 | Danger Plates |
| 708 | Anti-Climbing Device with Clamps |
| 709 | Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender