Tender For Addition/Alteration Of Bldg No T-105 Of 2136 Fd Hosp At Karcham Under Ge 863 Ews.
Tender Value
38.21 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
3 days left
EMD
76420
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kinnaur → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/Alteration Of Bldg No T-105 Of 2136 Fd Hosp At Karcham Under Ge 863 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of wall and ceiling boards(fibre, pulp, insulationetc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified and as directed by Engineer-In-Charge.. |
| 2 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and as directed by Engineer-In-Charge. |
| 3 | Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames) complete all as specified and as directed by Engineer-In-Charge. |
| 4 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed by Engr-in-charge. |
| 5 | Dismantling framed timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified. |
| 6 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and as directed by Engineer-In-Charge. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and as directed by Engineer-In-Charge. |
| 8 | Demolition of RCC Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer-In-Charge. |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-In-Charge. |
| 10 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 meter in depth and getting out in soft/disintegrated soil complete all as specified and as directed by Engineer-In-Charge. |
| 11 | M & L for PCC (1:4:8) type D-2 using40mm graded stone aggregate in foundation/filling and mass concrete complete all as specified and as directed by Engineer-In-Charge. |
| 12 | M & L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-In-Charge. |
| 13 | M&L For Reinforced cement concrete Nominal Mix 1:1.5:3 Type A 1(using 20 mm graded stone aggregates) in foundations, footing, plinth beams, bases for columns and mass concrete (reinforcement to be measured separately) complete all as specified and as directed by Engineer-In-Charge. |
| 14 | All are as per item no 13 but in column complete all as specified and as directed by Engineer-In-Charge. |
| 15 | M&L For RCC 1:2:4 type B-1, ( using 20 mm graded stone aggregate ) as in beams, cantilevers, bed block, bressummers, lintels over 1.5m span , including necessary form work etc complete all as specified and as directed by Engineer-In-Charge. |
| 16 | M & L for Reinforced Cement Concrete Nominal Mix 1:1.5:3 Type A 1(using 20 mm graded stone aggregate) in Chajjas and the like complete all as specified and as directed by Engineer-In-Charge. |
| 17 | M & L for Reinforced Cement Concrete Nominal Mix 1:1.5:3 Type A 1(using 20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and inshelves and the like complete all as specified and as directed by Engineer-In-Charge. |
| 18 | M & L Use and waste of Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified & directed. |
| 19 | All as per item no 18 above but sides of square column fair finished surface complete all as specified & directed. |
| 20 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed. |
| 21 | Use and waste for flat Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Engineer-In-Charge. |
| 22 | Use & waste for Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surface complete all as specified and as directed by Engineer-In-Charge. |
| 23 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 24 | M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 25 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cement all as specified and as directed. |
| 26 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed . |
| 27 | M&L for rendering 5 mm thick on concrete surfaces of wall / vertical surfaces in cement mortar 1:3, and finish the surface even and smooth without using extra cement complete all as specified and as directed . |
| 28 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 29 | M & L for PCC 1:2:4 type B-1, 40 mm thick, using 20mm graded stone aggregate as in surface of flooring finishing surface even and smooth without using extra cement all as specified and directed. |
| 30 | S&F light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles n.exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed be in C:M 1:4 complete all as specified and directed by engr in charge complete all as specified and directed by engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE |
| 31 | S&F light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, Verticle surfaces such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendiring in C:M 1:4 as in backing coat complete all as specified and directed by engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 32 | S&F in repairs Stainless steel sink with draining board made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mmx330mmx160mm |
| 33 | M&L for granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jombs, pillars, window-cill, cooking plateform and like in cement mortar (1:4) and with white cement (1:2) using pointing marble dust with admixture of pigment to match, including Circular cutting or notching and waste of any thickness and size of tiles moulding of granite complete all as specified and as directed. |
| 34 | S&F aluminium colour powder coated anodised door and shutter or double leaf glazed/pre laminated board exterior quality partly glazed/pre laminated board exterior quality partly glazed panels fabricated including aluminium anodised beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size including taking down existing old door of any description complete comprising the following:-(a) Aluminium colour anodised door frame section 101.60x44.45x1.93 mm fixed as per spd(b) Aluminium colour anodised verticle section in shutter 85x44.45x2 mm as per spd(c) Aluminium colour anodised top & style shutter section 95.25x44.45x2.00 mm as per spd (d) Aluminium clolour anodised handle 02 Nos in each shutter 200 mm long as spd(e) Aluminium clolour anodised middle lock rail/bottom rail section 150x44.x2.65mm.(f) Floor spring (g) Six lever mortice lock brass(h) 12mm thcik particle board (pre laminated both face) exterior grade ISI Marked(j) Tinted glass/plain glass (colour) 5mm thick Note :- If ground requirment for full glass or full panel contractor should provide as per direction of Engr-in-Charge |
| 35 | S & F for 12mm thick Toughned glass as in door shutter (DS), including cutting to shape, drilling holes,floor spring,decorative handle,locking arrangement required. complete all as specified and directed by Engr-in-Charge |
| 36 | S & F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 37 | S&F in Powder coated aluminium sliding window with shutter styles 40mm x20 mm sheet thickness 1.2mm two shutter of glass and one shutter of wire mesh consisiting of Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 91.80mmx31.75mmx1.2mm thick section (three track) with or without rebate. 5 mm thick tinted glass fixed with aluminium beads locking arrangement with each shutter all as directed by the Engineer-in-Charge.Note: Size of window shall be as per site requirement. |
| 38 | Excavating in post holes in hard/dense soil (or similar holes) each n exc 0.5cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed by engr in charge. |
| 39 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete.complete all as specified and directed by engr in charge. |
| 40 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc.Fe-410-W(gde-E-250) quality A complete all as specified and directed. |
| 41 | S&F For 1000 ltr. Capacity rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) hoisted and fixed in position including all fittings complete all as specified in SSR Part I complete all as specified and directed. |
| 42 | M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 43 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by engr in charge. |
| 44 | M & L Prepainted galvanume aluminium zine coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws complete all as specified and directed |
| 45 | Prepainted galvanume aluminium zine coating GI based plain steel sheeting 0.50 mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws complete all as specified and directed |
| 46 | S & F Rolled Mild Steel sections confirming to Fe 410-W (Gde-E-250) quality A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified and directed by engr in charge. |
| 47 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including welding etc all as spfd and directed by EIC.Fe-410-W(gde-E-250) quality B complete all as specified and as directed by Engr-in-charge. |
| 48 | S&F hangers 6mm dia G.I. (upto 1200mm length ) adjusting level, size of grid 605mm X605mm, fixed to Purlin/rafter mean of ceilling cleats made out of GI flat 40X3mm size 60 mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by engr in charge. |
| 49 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mmthick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. size of grid 605mm X605mm complete all as specified and directed. |
| 50 | S&F 6mm thick non asbestos fiber cement building board ( Designer board ) ,fixed to aluminium or MS galvanised snap grid frame work with screw in ceiling complete all as specified and directed by engr in charge. |
| 51 | S&F in repair 20mm dia curtain rods fancy type, mild steel chromium plated with fixing brackets, stops, rollers complete all as specified and as directed by Engr-in-charge. |
| 52 | S&F For Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel,complete all as specified and directed by engr in charge. |
| 53 | S&F For 5mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by engr in charge. |
| 54 | M&L preparing newly plastered surfaces of wall and applying complete wall with 1.5 mm Wall putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed by Engineer-in-Charge. |
| 55 | M & L for preparation of new wall plastered surfaces, applying three coats of white wash complete all as specified and directed. |
| 56 | Preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed by engr in charge. |
| 57 | M & L for Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer. |
| 58 | Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 59 | M&L 2nd class hard wood area exc 13 sqcm but nexc 25 sqcm in Plain fillets square, rectangular or triangular in section, clean sawn, secure fixed with screw or nails or brads complete all as specified and directed. |
| 60 | M&L 9mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and directed. |
| 61 | M & L for Solid PVC Wall Lining consisting of 5mm thick any colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed by Engineer-In-Charge. |
| 62 | M & L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed by Engineer-In-Charge. |
| 63 | S & F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube etc complete all as specified and as directed by Engineer-In-Charge. |
| 64 | S & F factory made solid PVC moulded door shutter, 30 mm thick 2mm thick 3D wood grain Moulded PVC sheet polyurethane painted on the front face & 2mm plain colour PVC sheet on back facecomplete all as specified and as directed by Engineer-In-Charge. |
| 65 | S & F Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as specified and as directed by Engr-in-charge. |
| 66 | M&L Aluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm complete all as specified and as directed by Engr-in-charge. |
| 67 | S&F 125mm long aluminium anodised handles or extruded section complete all as specified and as directed by Engineer-In-Charge. |
| 68 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed by Engineer-In-Charge. |
| 69 | Taking up or down 20m bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by engr in charge. |
| 70 | M & L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water complete all as specified and directed by engr in charge. |
| 71 | S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed by engr in charge. |
| 72 | S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed by engr in charge. |
| 73 | S&F in repair vitreous china wash basin ,white ,flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets , waste coupling complete all as specified and directed by engr in charge. |
| 74 | S & F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device vitrious Chaina pedestal pattern WC incl PVC seat cover etc complete all as specified and directed by Engr in charge. |
| 75 | S&F in repair 10 ltr capacity PVC valveless , syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including brackeet and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed by Engr in charge. |
| 76 | S&F in repairs vitreous china urinal half stall type flat back size of white with grating and union for discharge pipe including chromium plated water spreader , connection pipe and discharge down pipe complete all as specified and as directed. |
| 77 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed by engr in charge. |
| 78 | S&F in repair 15 mm dia pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered 'Hot' or 'Cold' woth long shanks and flynuts, screwed for iron pipe complete all as specified and directed by engr in charge. |
| 79 | S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed by engr in charge. |
| 80 | S&F in repair 15mm fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed by engr in charge. |
| 81 | S&F in repair 15mm dia stop valve / Angle valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed . |
| 82 | S&F in repair brass CP mixer, 15mm bore ,for mixing hot & cold water screw down for iron pipe complete all as specified and directed by engr in charge. |
| 83 | S&F 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by engr in charge. |
| 84 | S&F 110mm PVC(SWR) bend any radius complete all as specified and directed by engr in charge. |
| 85 | S&F 110mm PVC(SWR) junction single(single T) equal or unequal complete all as specified and directed by engr in charge. |
| 86 | M&L 75mm PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed by engr in charge. |
| 87 | S&F 110mm PVC(SWR) vent cowl complete all as specified and directed by engr in charge. . |
| 88 | S & F in repair coloured toilet paper holder,vitreous china box type fixed to wall with chromium plated brass screws complete all as specified and directed by engr in charge. |
| 89 | S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed by Engineer-In-Charge. |
| 90 | S&F in repair aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by Engineer-In-Charge. |
| 91 | S & F in repair for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer-In-Charge. |
| 92 | S & F for 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chroimium plated brass screws and cup washers complete all as specified and directed. |
| 93 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. complete all as specified and directed by engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 94 | M&L for glazed ceramic coloured tiles in verticle surface 300mm x 450mm x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat 10mm thick cement mortar in 1:4 complete all as specified and directed by engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 95 | M&L Cutting into existing manholes 110mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed, |
| 96 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-In-Charge. |
| 97 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by engr in charge. |
| 98 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and as directed by Engineer-In-Charge. |
| 99 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement complete all as specified and directed. |
| 100 | M & L for providing cement concrete cas in situ 1:2:4, type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edge including use of formwork complete all as specified and directed by engr in charge. |
| 101 | S & F door closer hydraucalically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed by engr in charge. |
| 102 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. including making good to the disturbed surfaces of wall, roof and floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 103 | M&L for point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC casing capping medium grade ISI Marked and all casing capping accessories fixed on wall/fixed to roof/truss/colums etc and including provision of 1.5 sqmm PVC insulated copper acble FRLSH as earth continuty conductor, febricated branded modular metal flush box duly make embossed, conncealed in walls with suitable modular inner and outer plate for housing modular switches, socket outlet and fan regulator etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 104 | All as per Srl item No 103 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 2.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 105 | All as per Srl item No 103 here-in-before but controlled with one 5 pin socket outlet 5 Amp, independent board with cable 1.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 106 | All as per Srl item No 103 here-in-before but controlled with one Modular Bell push 6A 1 module complete |
| 107 | All as per Srl item No 103 here-in-before but controlled with one 5 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 108 | Supply and fix in replacement of switch modular type 15 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 109 | Supply and fix in replacement of socket modular type outlet 5 pin 15 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 110 | Supply and fix in replacement of socket modular type outlet 5 pin 5 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 111 | Supply and fix in replacement of switch modular type type 5 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 112 | Supply and Fixing of Bell buzzers Multi Music type, all as per specified and directed by Engineer-in-Charge. |
| 113 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 AC decorativ type with driver jolder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 114 | Supply and fix in replacement of Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 115 | Supply and fix in replacement of surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. |
| 116 | S&F in replacement of indoor wall light E27 led bulb, antique brass 230 V AC indoor type with high pressure die cast and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 20 protection complete. all as specified and directed. Make Luker Product name BONITO WS-12 Cat Part No:-LWL135-1 OR EQUIVALENT |
| 117 | Supply and fix in replacement of stepped type electronic fan regulator modular type 120W 2module type on the existing phenolic laminated sheet etc.all as specified and directed by Engg-in-Charge. |
| 118 | Supply and fix in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 119 | S&F in replacement of outdoor wall light 2x6w, alu dia cast glass 230 V AC outdoor type with high pressure die cast and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 54 protection complete. all as specified and directed. Make Luker Product name ORA OW6 Cat Part No:-LODWS205 OR EQUIVALENT |
| 120 | Supply and fix in replacement of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply and fix in replacement of MCB SPN 40Amp,10 KA all as specified and directed by Engineer-in-Charge |
| 122 | Supply and fix in replacement of MCB SP 6 to 32 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. |
| 123 | Supply, laying in replacement of LT UG XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sq mm 4core as per IS specifications complete all as specified and directed |
| 124 | Supplying and fixing 1100 volts grade heavy duty, XLPE aluminium cable, in service connections,twin core 10 Sqmm 2 core Circural cabel, complete all as per specified and directed by Engineer-in-Charge. |
| 125 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles complete all as specified and directed |
| 126 | Returning and filling in refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- Surplus soil if any shall not be removed but left proud over the trench |
| 127 | S&F in replacement of indoor hanging light 40W pandent light 230 V AC indoor type with high pressure die cast aluminum diffuser hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 20 protection complete. all as specified and directed. Make Luker Product name CLO S2 Cat Part No:-LHL304 OR EQUIVALENT |
| 128 | S&F in replacement of indoor hanging light 20W pandent light 230 V AC indoor type with high pressure die cast aluminum diffuser hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 20 protection complete. all as specified and directed. Make Luker Product name AKIRO P1 Cat Part No:-LHL305 OR EQUIVALENT |
| 129 | M&L for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 50 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 130 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions. |
| 131 | M & L for earthing galvanished iron strip 25x4mm all as specified and directed by Engr-in-Charge |
| 132 | Supply and fix electric Water heater storage type tank and heating element upto capacity 50 litres.BEE 5 star rated complete with all accessories such as safety valve, thermosate NRV connection pieces etc. Note: Fixing of geyser on wall with suitable size anchor bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 133 | Supply and fix electric Water heater storage type tank and heating element upto 2 KW capacity 25 litres.BEE 5 star rated complete with all accessories such as safety valve, thermosate NRV connection pieces etc. Note: Fixing of geyser on wall with suitable size anchor bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 134 | Supply & fix exhaust fan made of steel body complete with AC, Single Phase 230/240V 450mm complete all as per specified and directed by Engineer-in-Charge Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 135 | Supply & fix exhaust fan made of plastic body complete with AC, Single Phase 230/240V 300mm complete all as per specified and directed by Engineer-in-Charge Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 136 | Supply and fixing building LED street light fitting 35w 230 volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 Protection complete, all as specified and directed |
| 137 | Supply and fixing in replacement of sheet metal enclousure double door vertical type on load TPN for 12 way with encl all as specified and direted by Engr-in-Charge |
| 138 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, min delivery 210CFM with service value five stat rated with brushless direct current motor (BLDC) complete all as specified and directed |
| 139 | S & F for fixing of GI Pipe bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED Street light fittings and fixing to pole, walls etc including fixing of clamp, nut bolt etc as specified and directed |
| 140 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender