Tender For Special Repair Of Bldg No.T-27 (Adm Block) At Lekhapani Mil Stn Under Ge Dinjan No.2
Tender Overview
Project Description
Tender For Special Repair Of Bldg No.T-27 (Adm Block) At Lekhapani Mil Stn Under Ge Dinjan No.2
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Date corrigendum | Date | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engineer- in- Charge |
| 2 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and directed by Engineer- in- Charge. |
| 3 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed by Engineer- in- Charge |
| 4 | Dismantling boarding, any description fixed in any position with nails complete all as specified and directed by Engineer- in- Charge |
| 5 | Taking down roof trusses, coupled rafters or trussed beams of clear span above 4 mtrs and upto 8 mtrs complete all as specified and directed by Engineer- in- Charge. |
| 6 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and directed by Engineer- in- Charge |
| 7 | Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any posotion complete all as specified and directed by Engineer- in- Charge. |
| 8 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed by Engineer- in- Charge. |
| 9 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified and directed by Engineer- in- Charge. |
| 10 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer- in- Charge. |
| 11 | Demolition of reinforced cement contrete of any description in any position not otherwise specifically provided for complete all as specified and directed by Engineer- in- Charge. |
| 12 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed by Engineer- in- Charge |
| 13 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and directed by Engineer- in- Charge . |
| 14 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed by Engineer- in- Charge . |
| 15 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed by Engineer- in- Charge. |
| 16 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation filling amd mass concrete complete all as specified and directed by Engineer- in- Charge |
| 17 | M&L for RCC Type A-1 1:1 1/2:3 (using 20mm nominal size graded crushed stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer- in- Charge. |
| 18 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer- in- Charge. |
| 19 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer- in- Charge |
| 20 | M&L for RCC Type A-1 1:1 1/2:3 (using 20mm nominal size graded crushed stone aggregate ) as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete including necessary form work complete all as specified and directed by Engineer- in- Charge. |
| 21 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed by Engineer- in- Charge. |
| 22 | M&L Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for rough finished flat surfaces of concrete complete all as specified and directed by Engineer- in- Charge. |
| 23 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer- in- Charge. |
| 24 | M&L TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer- in- Charge. |
| 25 | M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:4 complete all as specified and directed by Engineer- in- Charge. |
| 26 | M&L for brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls complete all as specified and directed by Engineer- in- Charge. |
| 27 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layer finished fair and even with mixing water proofing compound to top layer as per manufacturers instruction and as directed (WPC will be measured separetely) complete all as specified and directed by Engineer- in- Charge |
| 28 | Supply only Integral water proofing compound of approval brand complete all as specified and directed by Engineer- in- Charge |
| 29 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 to 2 mm thick and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engineer- in- Charge |
| 30 | M&L for rendering 10.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement complete all as specified and directed by Engineer- in- Charge |
| 31 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 to 2 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed by Engineer- in- Charge |
| 32 | S&F Pressed steel frames (125 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed by Engineer- in- Charge |
| 33 | M&L for plain cement concrete (1:3:6), type C-0, (using 12.5mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed by Engineer- in- Charge |
| 34 | S&F 30mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats complete all as specified and directed by Engineer- in- Charge |
| 35 | S&F 35 mm thick, hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified and directed by Engineer- in- Charge. |
| 36 | S&F MS butt hinges,medium weight, cold rolled 100mm long complete all as specified and directed by Engineer- in- Charge |
| 37 | Supply only 2nd Class hard wood small fittings such as brackets of any type ,latch and hinge blocks,shaped door and window stops and like ,including all necessary labours,articles n exc 200Cu.cm each complete all as specified and directed by Engineer- in- Charge |
| 38 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer- in- Charge |
| 39 | S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete all as specified and directed by Engineer- in- Charge |
| 40 | S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified and directed by Engineer- in- Charge |
| 41 | S&F 300mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer- in- Charge |
| 42 | S&F 375mm long Mild steel ordinary rat tail rod pattern springs for door including roller and roller plate complete all as specified and directed by Engineer- in- Charge |
| 43 | S&F anodised aluminium powder coating (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified and directed by Engineer- in- Charge |
| 44 | S & F anodised aluminiumpowder coating of any colour (Thickness or powder coating not less than 50 micron). door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer- in- Charge |
| 45 | S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer- in- Charge |
| 46 | S & F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed by Engineer- in- Charge |
| 47 | S & F for aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and directed by Engineer- in- Charge |
| 48 | Material & labour for false ceiling with GI frame work for EXPOSED GRID SYSTEM of grid size 600 mm x 600 mm, GI powder coating at bottom and comprising of GI perimeter wall angle with two equal flanges of 25 mm fixed to surrounding wall / partition using nylon sleeves and screws at 450 mm centre to centre. Main Tee 0.55 mm thick having 35 mm wide flange and 25 mm high web suspended from the soffit @ 1200 mm centre to centre with level clip with wire of 4 mm dia, Cross Tee - 1200, 0.55 mm thick having 35 mm wide flange and 25 mm high web inserted fixed into the slots of Main 'T' @ 600 mm centre to centre to form a grid of 1200 mm x 600 mm, Cross Tee - 600, 0.55 mm thick having 35 mm wide flange and 25 mm high web shall be placed perpendicular to the Cross Tee - 1200 to finally form a grid of 600 mm x 600 mm . complete all as per manufacturer instructions complete all as specified and directed by Engineer- in- Charge |
| 49 | S&F 4mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 2 to 3 mm dia GI wire hangers fixed with steel dash through fasteners from purlins with butterfly clips, hold down clips, with provision of ligh fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc. complete all as per manufacturer instructions and complete all as specified and directed by Engineer- in- Charge. |
| 50 | S & F mild steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 complete all as specified and directed by Engineer- in- Charge |
| 51 | S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed by Engineer- in- Charge. |
| 52 | S&FMild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long complete all as specified and directed by Engineer- in- Charge |
| 53 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed by Engineer- in- Charge |
| 54 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and directed by Engineer- in- Charge |
| 55 | M&L for 50 mm thick Cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete all as specified and directed by Engineer- in- Charge |
| 56 | M&L for coloured Matt finished joint finished ceramic tiles of 7mm to 8mm thick (Appx size 600mmx600mm) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer- in- Charge |
| 57 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified and directed by Engineer- in- Charge |
| 58 | M&L for glazed coloured ceramic tiles in vertical surface 300x450x6 to 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles laid over & including 10 mm thick rendering as in backing wall plaster in cement mortar (1:4) complete all as specified and directed by Engineer- in- Charge |
| 59 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile not exceeding 0.11 Sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer- in- Charge |
| 60 | S&F 15mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer- in- Charge |
| 61 | S&F 20mm dia bore of pipes, medium grade, galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed by Engineer- in- Charge |
| 62 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer- in- Charge |
| 63 | S&F fancy type long body 15mm dia Bib taps cast copper alloy, chromium plated screwed down to iron pipe or for brass ferrule & fixed complete all as specified and directed by Engineer- in- Charge |
| 64 | S&F fancy type swan long neck 15mm dia pillar taps suitable, cast copper alloy with capstan heads, chromium plated , screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipe & fixed complete all as specified and directed by Engineer- in- Charge. |
| 65 | S&F vitreous china wash down water closet, \\"Pedestal pattern with fixing bolt, plastic water closet seat cover, white, closed pattern with flat bottom and cover with aluminised hinging device, complete all as specified and directed by Engineer- in- Charge |
| 66 | S & F in repairs Vitreous China wash down water closet pan including P or S trap, bolts, connection to plushing pipe anti-syphonage pipe etc complete all as specified and directed by Engineer- in- Charge |
| 67 | S & F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer- in- Charge |
| 68 | S & F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer- in- Charge |
| 69 | S&F Wash basins white, vitreous China, size 580x450mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets fixed to wall complete all as specified and directed by Engineer- in- Charge |
| 70 | S/FTowel Rail 600 mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms) complete all as specified and directed by Engineer- in- Charge. |
| 71 | S&F PVC High/Low level flushing cistern 10 litres capacity including all fittings i.e float valve, syphon, flush pipe, brackets complete all as specified and directed by Engineer- in- Charge |
| 72 | S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engineer- in- Charge |
| 73 | S&F 15mm bore dia stop valves / angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer- in- Charge |
| 74 | S&F 15mm swivel shower with arm 195mm long of PTMT of any colour for fixing with 15mm pipe (Min weight 40 gms) complete all as specified and directed by Engineer- in- Charge |
| 75 | M&L 75mm dia PVC (SWR) floor trap/nahani trap, plain with grating including jointing with solvent cement in repair complete all as specified and directed by Engineer- in- Charge. |
| 76 | S&F mirror of selected quality glass, mounted on 4mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed complete all as specified and directed by Engineer- in- Charge |
| 77 | S & F steel windows/ ventilator with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer- in- Charge |
| 78 | S & F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed by Engineer- in- Charge. |
| 79 | M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer- in- Charge. |
| 80 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer- in- Charge. |
| 81 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer- in- Charge. Please Enable Macros to View BoQ information |
| 82 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer- in- Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender