Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57971579

Tender For Special Repair And Conversion Of Overhead Lt Line To Ug Lt Line And Connected Items At Ph-Iii Area Of Age E/M Under Ge Tenga

Issued by Statutory Bodies & Commissions/Committees · siliguri, West Bengal
Tender Value
36 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
11 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
siliguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair And Conversion Of Overhead Lt Line To Ug Lt Line And Connected Items At Ph-Iii Area Of Age E/M Under Ge Tenga

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 13-Oct-2026 BOQ CORRIGENDUM BOQ 31-Oct-2026

BOQ

Name of Work:-
Sl. No. Item Description
1Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
2Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
3Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
4Materials & Labour for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
5Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed.
6Materials & Labour for PCC 1:4:8 type D2 with 40 mm graded aggregate for poles / filling in mass concrete complete all as specified and directed.
7Materials & Labour for PCC 1:3:6 Type C2 for erection of pole in base with 40 mm graded coarse aggregate complete all as specified and directed.
8Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar, outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following :-
9(a) Aluminium bus bar four Nos 300 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 125-160 Ampsconforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 80-100 conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) (d) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 50-63 conforming to IEC 60947 Part-I/IS-13947 Part-I - 04 No (Ics=Icu=100%)(e) Spare for MCCB upto 100 Amps - 01(f) MCB SPN 40 AMP 10 KA - 04 Nos
10(g) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA - 1Set. (h) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
11Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar, outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following :-
12(a) Aluminium bus bar four Nos 200 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:-(b) MCCB, 04 Pole, 125 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 125-160 Ampsconforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings of range 50-63 conforming to IEC 60947 Part-I/IS-13947 Part-I - 03 No (Ics=Icu=100%)(d) Spare for MCCB upto 100 Amps - 01(e) MCB SPN 32 AMP 10 KA - 03 Nos
13(f) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA - 1Set. (g) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (i) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 50cm above the nearest ground level. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
14Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested outdoor weatherproof IP-65 enclosure aluminium bus bar four Nos 300 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code, floor mounted ,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc. complete all as specified and directed.
15Supply & Fixing in repairs of MCCB, 04 Pole, capacity 125 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%) in the existing panel with suitable connecting copper terminals at site complete all as specified and directed.
16All as per item No 11 here in above but of capacity 200 Amps with ultimate breaking capacity 36 KA all as specified and directed.
17All as per item No 11 here in above but of capacity 250 Amps with ultimate breaking capacity 36 KA all as specified and directed.
18Supply & Fixing in repairs of MCB TPN, 4 Pole, capacity 40 to 100 Amps with ultimate breaking capacity 10 KA at 415 volts , \\"C\\" curve conforming to EN/IEC 60947-3 in the existing panel with suitable connecting copper terminals at site complete all as specified and directed.
19Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 120 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires.Note : Earth work, sand filling & PCC cover laying shall be measured and paid separately.
20All as per item No 15 above but of size 70 Sqmm 3.5 core all as specified and directed.
21All as per item No 15 above but of size 50 Sqmm 3.5 core all as specified and directed.
22All as per item No 15 above but of size 25 Sqmm 4 core all as specified and directed.
23All as per item No 15 above but of size 16 Sqmm 4 core all as specified and directed.
24All as per item No 15 above but of size 16 Sqmm 2 core all as specified and directed.
25All as per item No 15 above but of size 10 Sqmm 2 core all as specified and directed.
26All as per item No 15 above but of size 400 Sqmm 1 core all as specified and directed.
27Supply and laying or fixing or passing through pipe in repalcement, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape soild conductor armoured with galvanised steel wire or tape and overall PVC sheathed of size 16 sqmm nominal cross section in service connection complete all as specified and directed.
28Supply and laying galvanised tube light grade ISI marked of size 50 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
29Supply and laying galvanised tube medium grade ISI marked of size 100 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
30Materials & Labour for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
31Supply and laying HDPE pipe PN10, ISI marked, for cable protection on pole/wall/floor or in trenches and drain/culvert etc complete with necessary clamps, nuts, bolts, washers sockets complete with all fitting of size 75 mm bore all as specified and directed.
32Supply and laying HDPE pipe PN10, ISI marked, for cable protection on pole/wall/floor or in trenches and drain/culvert etc complete with necessary clamps, nuts, bolts, washers sockets complete with all fitting of size 50 mm bore all as specified and directed.
33Materials & Labour for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick buried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 40 mm dia light grade GI pipe and 20 mm dia medium grade GI Pipe for watering complete.
34Supply & Fixing in repairs of distribution board vertical type TPN 415 Volt for fixing 4 pole MCCB, double door IP 43 protection, 4 way with copper bus bars, neutral links , earth link, earthing studs, blanking plates, interconnection between incomer MCCB and bus bar duly prewired fixed flush to wall / other surface complete all as specified and directed.
35Taking down/dismantling existing old unserviceable steel poles of any size complete all as specified and directed.
36Taking down/dismantling existing old ACSR Conductor for repair/replacement complete all as specified and directed.
37Taking down/dismantling existing old cross arms for repair/replacement complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57971579
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair And Conversion Of Overhead Lt Line To Ug Lt Line And Connected Items At Ph-Iii Area Of Age E/M Under Ge Tenga
Basic Detail
Tender No 8292/E8
Bidding Type Tender
Location
City siliguri
State West Bengal
Key Dates
Publish Date 13 Oct 2026
Submission Date 31 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
BOQ_889655.xls
ff979e7d-8ba1-45b9-82e9-737d1dd77b94.html
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_889655.xls

html

ff979e7d-8ba1-45b9-82e9-737d1dd77b94.html

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender