Tender For Repair/ Replacement To Roof Treatment, Plumbing And Sanitary Fitting Under Age B/R-Ii Of Ge Sgnr Mil Stn
Tender Value
30 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
20 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement To Roof Treatment, Plumbing And Sanitary Fitting Under Age B/R-Ii Of Ge Sgnr Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in slab supported on walls, beam and column in floors, roofs,landings,balconies,deck slab, parapet walls and in shelves and etc and setting in mortar complete with joints to match complete all as specified and directed by engr in charge. Note : Rates of Demolition of RCC of any descrition are included |
| 2 | Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, in flat surfaces etc. complete all as specified and directed by Engr in charge |
| 3 | M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia |
| 4 | M&L brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc including demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specified and directed by Engineer - in - Charge. |
| 5 | Dismatiling brick tiles or terracing tiles, single layer on roofs and mud phuska complete all as specified and directed by Engineer - in - Charge.ded or chamfered on edges, complete, all as directed. |
| 6 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. |
| 7 | M&L Providing, cement concrete 1:2:4, type B0 using 12.50 mm graded stone aggregate with WPC as per manufacturer's instruction in roof kerbs or mud stops/roof padding, roof kerbs, rounded or chamfered on edges, making khurra etc complete all as specified and as directed by Engineer-in-Charge. Note- Qty of WPC/SBR measuredand paid saperately. |
| 8 | M&L 15-20 mm thick cement plaster with ready mixed plaster material with WPC as per manufacturer's instruction on roof top surfaces finished even and smooth without using extra cement including all as specified. (Note-Qty of WPC measured and paid saperately). |
| 9 | M&L 5 mm thick cement plaster in ready mixed plaster on ceiling surfaces finished even and smooth without using extra cement including taking down plastering on lathing (other than wire-netting), withoutremoving lathing, in cement mortar all as specified. |
| 10 | Supply of SBR waterproofing compound @ 2% of per kg cement or as per manufacturer's instruction used complete all as specified.Make : Fosroc/Sika/Choksey/Bostik/STP/Berger Paints / Asian Paints |
| 11 | Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement mortar complete all as spcified |
| 12 | M&L for 12-15 mm thick rendering with ready mix Plaster over any surfaces of brickwork, concrete surfaces finished even, fair & smooth finishes complete all as specified and directed. directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately. |
| 13 | M & L for three coats of white washing on new plastered surfaces of on ceiling surface including preparation of surface complete all as specified. |
| 14 | M & L Preparation of new plastered surfaces of wall and applying two coats ofweather coat exterior emulsion over 1.5 mm thick wall putty and exterior primer complete all as spd & directed |
| 15 | Taking up or down GI steel water tubing 15mm bore and connections including fittings from floor/walls/ceiling complete. |
| 16 | Taking up or down GI Steel water tubing 20mm bore and connections including fittings from floor/walls/centrings complete. |
| 17 | Taking up or down GI Steel water tubing 25mm bore and connections including fittings from floor/walls/centrings complete. |
| 18 | S & F 3- layer PP-R Polypropylene random copolymer) pipes 20mm outer diameter SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete. |
| 19 | S & F 3- layer PP-R Polypropylene random copolymer) pipes 25mm outer diameter SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete. |
| 20 | S & F 3- layer PP-R Polypropylene random copolymer) pipes 32mm outer diameter SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete. |
| 21 | Dismantling water tanks exc 500ltr but n. exc 1000 Ltr and removing to store complete all as specified and directed. |
| 22 | S&F rotational molded polythylene water storage tank 1000 ltr capacity (Cylinderical vertical with closed top) white coloured, three layered premium quality tank hoisted and fixed in position including suitable uPVC tank Nipple for water tank complete all as specified |
| 23 | S&F rotational molded polythylene water storage tank 500 ltr capacity (Cylinderical vertical with closed top) white coloured, three layered premium quality tank hoisted and fixed in position including suitable uPVC tank Nipple for water tank complete all as specified |
| 24 | S&F 25 mm ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe, all as specified. |
| 25 | Re-Fixing only in repairs 25 mm ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe, all as specified. |
| 26 | S&F Bands, straps, supports or stays for rainwater (minimum gaps between surface of structure & Pipes should be 100mm), ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, tank conforming to Fe-290 Gde-E-165 |
| 27 | M&L two coat of synthetic enamel paint on old painted surfaces of steel and iron work over 10 cm width or girth including preparation complete. |
| 28 | M&L, two coats of synthetic enamel paint over a coat of red oxide on steel surface over 10 cm width or girth, not otherwise described including preparation of new surface. |
| 29 | S&F 110mm bore uPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall with PVC holding clamps/laid int trenches and includging Demolition and breaking up or taking down PVC/AC/CI/SSW 100mm bore pipe drain pipes, set in cement mortar including PCC haunching and bedding, complete complete, all as directed. |
| 30 | S&F 110mm bore uPVC (SWR) bend/Tee with rubber ring, any radius with access door. |
| 31 | S&F 110mm bore uPVC (SWR) with rubber ring vent cowl. |
| 32 | S&F 110mm bore uPVC 'S/P' Trap with rubber ring. |
| 33 | S & F Stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays for 100mm bore of pipe, including bolts and nuts and securing ends of stays (minimum gaps between surface of structure & Pipes should be 100mm) to wall or roof etc complete all as specified and directed by Engineer - in - Charge. |
| 34 | S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends compitible for PP-R and fixed |
| 35 | Dismantling and Re-Fixing in repairs serviceable 20 mm Gun-metal, globe or gate valves, powder coated with iron wheel head, screwed both ends compitible for PP-R and fixed |
| 36 | Disconnecting existing tanks of capacity exceeding 500 litres to 1000 litres etc, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed by Engineer in Charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender