Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57971008

Tender For Special Repair To Bldg No Ht-18 Cw Line Under Age B/R-I Ge (N) Ambala Cantt.

Issued by Statutory Bodies & Commissions/Committees · Ambala, Haryana
Tender Value
27.20 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
20 days left
EMD
54400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Bldg No Ht-18 Cw Line Under Age B/R-I Ge (N) Ambala Cantt.

BOQ

Name of Work:- Special repair to Bldg No HT-18 CW Line under AGE B/R-I GE (N) Ambala Cantt.
Sl. No. Item Description
1Schedule 'A' Part-I (B/R itmes)Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed.
2Dismantling timber scantlings 40 sq. cm and over in section in any position ( unframed work ) , complete all as specified and directed.
3Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall curved/lgloo type curved structure of minimum radius not exceeding 6 metre,fixed with self tapping screws complete all as specified and as directed.
4Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof ridge,valley gutter etc fixed with self tapping screws complete all as specified and as directed.
5Supply and fixing rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed .
6Material and labour preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed .
7Material and labour preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed .
8Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed
9Material and labour brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed .
10Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
11Material and labour for rendering 15mm thick in cement plaster (1:6) on any faces of brick work or concrete wall surfaces and finished even and smooth without using extra cement including necessary scaffolding etc complete all as specified and as directed.
12Material and labour rendering 15 mm thick (in patches) on brick work or concrete wall surfaces in cement mortar (1:4) including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished even and smooth without using extra cement complete, all as specified and as directed by the Engineer-in-Charge. ( Note- WPC shall be measured & paid for separately)
13Supply only integral water proofing compound, ,complete all as specified and directed.
14Material and Labour for prepartion of new plastered/ concrete surfaces and applying two coats of oil bound emulsion or acrylic distemper over and including one coat of primer and one coat of water proof putty on surface, complete all as specified and directed.
15Material and Labour for preparation of new plastered surface of wall incl applying premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm all as specified and directed .
16Dismentling of stone slabs of any description or any thickness laid bedded and pointed in any mortar in floors and walls approns etc., complete all as specified and directed.
17Dismentling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises , complete, all as specified and as directed.
18Material and labour double charged vitrified ceramic light shade tiles premium/1st quality, 9-10mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but n.exc. 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and as directed.
19Material and labour double charged vitrified ceramic light shade tiles premium/1st quality, 9-10mm thick of same description as of floor tiles as in serial item No 18 above but 100 to 150mm height as in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:4 complete all as specified and as directed .
20Material and labour non–skid ceramic coloured tiles joint free premium/1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
21Material and labour glazed ceramic coloured tiles joint free premium/1st quality in vertical surfaces/ skirtings /dados of size 300 x 600 x 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on any faces of brick /concrete surfaces in cement mortar 1:4 complete all as specified and as directed .
22Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed .
23Supply and fixing Powder coated aluminium (min thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
24Supply and fixing powder coated aluminium section (minimum thickness of powder coating 50 micron) for frame and shutters of doors, windows (fixed, sliding, hanging) & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified and as directed.
25Supply and fixing powder coated aluminium section (minimum thickness of powder coating 50 micron) for three track frame and sliding shutters of windows & sliding ventilators including providing and fixing making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws complete all as specified.
26Material and labour for sheet glass 4.80mm thick, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed.
27Supply and fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and as directed.
28Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other frames/ chowkhat of size 50 x 75 mm comprising of virgin PVC polymer of K value 58–60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant , ,complete all as specified and directed.
29Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges and necessary SS screws shall be paid separately) complete all as specified and as directed.
30Supply and fixing factory made single extruded WPC (Wood Polymer Composite) joint less fly proof shutters made out of solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-in-Charge.
31Supply and fixing for 65 mm size long mortice lock vertical type, 2 levers with key in duplicate, mild steel body fixed in shutters with screw complete all as specified and as directed by the Engineer–in–Charge
32Supply and fixing 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed ,complete all as specified and as directed.
33Supply and fixing 150 mm long aluminium handle cast type anodised ,complete all as specified and as directed.
34Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed.
35Dismantling Brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed .
36Demolition of mud in roofs, any thickness, including plastering and leeping (whethere full thickness removed or only a part thereof) including removing old tar felt, all loose dirt, cement plaster, cleaning the concrete surface including removal & cleaning of vegetation, fungus, moss, small trees etc from the roof top with wire brush, removing the strips of lightening conductor including refixing the same after repair work complete all as specified and directed .
37Material and labour for providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in roof kerbs or mud stops, padding, rounded or chamfered on edges including from work where ever required complete all as specified and as directed .
38Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bituminous primer @ 0.40 litre /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temperature and viscosity 70–160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc. after preparing the surface complete as per standred practice as per manufacture's instructions. The vital physical and chemical parameters of the membrane shell be under :–(i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms(ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d–5147)(iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer–in–Charge.(iv) The work shall be carriout at a height upto 12 metre.
39Material and labour cement concrete tiles 30 cm x 30cm x 20 mm thick, machine pressed laid on and including screed bed 15 mm thick in cement mortar 1:6 and joints grouted and pointed flush in CM (1:3) mixed with 5% crude oil by weight of cement including screed bed, complete all as specified and as directed .
40Material and labour for 10mm thick full body vitrified coloured paver tiles of size 600 x 600mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar (1:4) , complete all as specified and as directed.
41Material and labour for 50mm th PCC 1:2:4, Type B–1 (using 40mm graded crushed stone aggregate) as in sub base, foundations, filling and mass concrete complete all as specified and as directed.
42Supply and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage complete all as specified and as directed .
43Supply and fixing 20 mm bore Gun–metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair complete all as specified and as directed .
44Supply and fixing as in repair water storage tank, 500 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore and including 20mm bore tank nipple & one 20mm GI union at outlet and including dismantling of water tanks and removing to store all as specified in SSR Part–I complete all as specified and as directed.
45Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed .
46Material and Labour galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors as in repair, complete all as specified and as directed.
47Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed .
48Material and Labour galvanised iron tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors as in repair,complete all as specified and as directed.
49Supply and fixing 15mm bore cast copper alloy fancy type chromium plated stop valves with long shank and cup (concealed type), screwed down, high pressure with capstan head, screwed both ends for iron pipe or for unions as in repair complete all as specified and as directed .
50Supply and fixing fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed.
51Supply and fixing bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and as directed .
52Supply and fixing PVC connections 15 mm size with PTMT nuts of length 450 mm as in repair complete all as specified and as directed ..
53Supply and fixing vitreous china wash hand basin white, flat back of size 550mm x400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed .
54Supply and fixing in repair 15mm bore brass chromium plated overhead shower 200mm x 200mm square shape single flow alongwith 15mm bore shower arm 600 mm long complete all as specified and directed.
55Supply and fixing vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair complete all as specified and as directed .
56Supply and fixing vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including water closet pvc seat cover white closed pattern with flat bottom and cover including making connections and fixed in position as in repair complete all as specified and as directed.
57Supply and fixing 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connectionSupply and fixinglush pipes for WC as in repair complete all as specified and as directed.
58Supply and fixing soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws , complete, all as specified and as directed.
59Supply and fixing of corner Glass shelf 300 mm (with brass bracket) including fixing with brass screws to wall complete fixed as in repair complete all as specified and as directed..
60S&F in repair grating doom 125mm dia with waste hole of PTMT (minimum 50 gms) complete all as specified and directed.
61Taking down of 100mm internal dia PVC /cast iron drain pipes /rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan–necks, etc., including cleaning or refixing or removal to store, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
62Supply and fixing 100mm bore cast iron spun pipe for soil, waste and vent, single socketed, in any length with cement joints, laid in trenches complete all as specified and directed.
63Supply and fixing 100mm bore cast iron spun pipe for soil, waste and vent, single socketed, in any length with cement joints, fixed to walls including clamps complete all as specified and directed.
64Supply and fixing 100mm cast iron spun bends (any radius), diminishing pieces or tapers all as specified and directed.
65Supply and fixing as in repair 75mm bore cast iron spun pipe for soil, waste and vent single socketed, in any length with cement joints, fixed to walls including clamps complete all as specified and directed.
66Supply and fixing as in repair 75mm bore cast iron spun pipe for soil, waste and vent, single socketed, in any length with cement joints, laid in floors complete all as specified and directed.
67Supply and fixing 75mm cast iron spun bends (any radius), diminishing pieces or tapers all as specified and directed.
68Supply and fixing stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolt and nuts and securing ends of stay to wall or roof of 100mm more then 100mm dia complete all as specified and directed.
69Supply and fixing in repair 75 mm dia cast iron floor trap with grating incl jointing to waste pipe incl fixed in cement concrete type B–1 (1:2:4) complete all as specified.
70Material & labour for 110mm dia PVC (SWR) gully trap, setting and jointing with solvent cement complete all as specified.
71Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets/ aluminium partion/cabinets any thickness including cover fillets and false ceiling frame work complete all as specified and as directed .
72Material & labour of Providing & fixing false ceiling at all heights with semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, having moisture content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws all as specified and directed .
73Supply and fixing 5-8mm thick solid/ Hollow profile designer PVC paneling (thickness of inner wall 0.70mm to 1.00 mm) with panel of width 250mm to 300mm fixed to wall/ceiling with screw and rawel plug including PVC beading (U,L section) wherever required.complete all as specified and as directed .
74Preparation of exposed brick wall surface by cleaning the surface with wire brush to remove all dirt/loose materials from the bricks and from the joints between the bricks. Prepared surface should be then eashed with diluted HCL acid (Dilution ratio of 1:50) three times ina day for two day.After acid wash surface should be allowed to be air dried for one day.Carrying out efflorescence treatment to exposed and prepared wall surface in the following sequence:- (a) Prime the prepared surface with one of the following product mixed with cement in 1:1 ratio as bonding agent :- (i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (b) Immediately after priming the surface PMM (Polymer Modified Morter) to be applied \\"BY HAND\\" while the primer is tacky. PMM should be prepared by mixing one of the following compounds in Cement Mortar 1:3 as per manfacturer's instructions :-(i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (c) PMM surface should be allowed to dry for one day. After that it should be painted with two coats of one of the following compounds mixed with cement only in ratio of one part of selected compound and one point five part of cement :-(i) Pidicrete URP of M/S Pidilite (ii) Sika Latex of M/s Sika (iii) Nitobond SBR Latex of M/s FOSROC (d) Now apply two coats of one of the following compound over the surface. These compounds are to be used as per manufacturer instructions.
75Dismantling of barbed wire mesh fencing of any type/size and in any position, neatly coiled and removing from site complete, all as specified and as directed .
76Material and labour for PCC (1:3:6), Type C-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete, all as specified and as directed by the Engineer-in-Charge.
77Supply and fixing for mild steel section of any type or size as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe–290 Gde E–165 complete all as specified and as directed .
78Supply and fixing for mild steel screw bolts (machine made) of 10 mm dia, with hexagonal or square heads at one end and screwed the other and screwed end to be fitted with round washers and one hexagonal or square nut, length of bolt not exc 5 cm long complete, all as specified and as directed.
79Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete, all as specified and as directed .
80Supply only chain link fencing including line wires, any mesh size and type to any type of standards, complete, all as specified and as directed . Note :-Weight of chain link fencing shall be ascertained by BOO as ordered by GE.
81Material and labour for mild steel round bars 10mm dia and over ,cut to length, bent to shape, hooking ends for chain link fencing, complete all as specified and as directed .
82Material and labour for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete, all as specified and as directed .
83Material and labour preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
84Taking down and refixing of any description or size as in posts and struts in fencing mild steel flat iron or angle iron as directed, including drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., complete all as specified and as directed .
85Schedule 'A' Part-II (E/M itmes)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., complete all as specified and as directed.
86Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
87Description all as per serial item No.86 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed.
88Description all as per serial item No.86 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed.
89Description all as per serial item No.86 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge.Note : (i) Point wiring shall be done in a manner that not more than 02 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point.
90Description all as per srl item No 86 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge.Note : (i) Point wiring shall be done in a manner that not more than 01 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point.
91Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed.
92Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed .
93Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed.
94Supply and fixing of modular socket outlet multipin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed.
95Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed .
96Supply and fixing in repair LED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS20WLED865SPCSS of make Havells or equivalent in make given in Appx 'B'.
97S&F LED Bldg Security Light Fittings of capacity 35-45 watt made up of die cast Cast aluminium housing with black epoxy powder coating with cover heat resistance glass safty input voltage range 170 to 270 volts, with IP-66 protection and other connected accessories including service bracket of MS pipe 25/32 mm bore of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting to MS pipe as required at site and making electrical connection complete all as specified and directed.
98Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 05 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
99Supply and fixing LED tunnable luminaire 600mm x 600mm 35/36 watt 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
100Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB, 20 Amps, 10 KA, 'B' curve, including removing old unserviceable enclosure, complete all as specified and as directed .
101Supply and fixing sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811826 of make Indo Asian or equivalent in make given in Appx 'B'.
102Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge. Cat part No 811008 to 811015 of make Indoasian or equivalent make given in Appx 'B'.
103Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.Cat part No 811034 of make Indoasian or equivalent make given in Appx 'B'.
104Taking down and refixing only ceiling fan after cleaning in any model/size etc and making all connection using three core copper conductor flexible cable in size 1.5 sqmm including drawn through PVC flexible conduit pipe from ceiling rose to fan connector complete all as specified and directed.
105Taking down and refixing only exhaust fan after cleaning in any model/size etc and making all connection using three core copper conductor flexible cable in size 1.5 sqmm including drawn through PVC flexible conduit pipe from ceiling rose to fan connector complete all as specified and directed.
106Supply, laying, testing & commissioning XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area, 4 core with stranded aluminium conductor, 1100 volts grade as in repair complete all as specified and as directed. Note: execavation & earth work shall be measured & paid for separately.
107Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, manholes or laying of cable etc., not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
108Supply and fixing as in repair light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts, washers complete all as specified and as directed.
109Material and labour for dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed Note: punned thickness shall be measured for payment.
110Supply and laying well burnt brick class–B laid flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed.
111Returning, filling in, including spreading, levelling ,watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and as directed.
112Removing surplus excavated material to a distance not exc. 50m and depositing where directed complete all as specified and as directed .
113Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) IP-54 with and including MCCB 100 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar, flush /surface mounting, double door, duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed .
114Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
115Supply and fixing LED Bollard 8-10 watt, IP-65 , 6500 K luminaire made of pressure die cast aluminium housing and clear glass , 240 volt, 50HZ, AC supply , complete with all accessories including electronic driver, internally pre wired including connecting with three core flexible copper conductor cable from Electric Supply Source to connector of the light as in repair complete all as specified and as directed.
116Material & labour for sub-main wiring with two single core FRLSH PVC insulated and unsheathed cable with stranded copper conductor of 1.5 Sq mm drawing in & excluding PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional wire of 1.50 Sq mm but green in colour for earth DBs and boxes with proper thimbles all as specified and directed. For servent qtrs.Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) 3 runs of 1.5 Sqmm cable and one run of conduit, will be measured as one unit .
117Supply and laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of 06 Sqmm cable and one run of PVC conduit shall be measured and paid as one unit length.
118Note:- Amount of credit of Rs. 50,198.00 for retrieved materials is mentioned in Schedule of Credit Page No..123 & 124 of tender doCubic metre ents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57971008
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 27.20 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Bldg No Ht-18 Cw Line Under Age B/R-I Ge (N) Ambala Cantt.
Basic Detail
Tender No GE(N)/AMB-69/2026-27
Bidding Type Tender
Location
City Ambala
State Haryana
Key Dates
Publish Date 10 Oct 2026
Submission Date 31 Oct 2026
Open Date 02 Nov 2026
Finance
Tender Value 27.20 Lakhs
Tender Fee 500
EMD 54400
Exemption Available
Document List
2554cc49-2d47-4d74-8f6b-ec0fca68482f.html
BOQ_889613.xls
Tenderdocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

2554cc49-2d47-4d74-8f6b-ec0fca68482f.html

xls

BOQ_889613.xls

pdf

Tenderdocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders