Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #57970369

Tender For Improvement Strengthening And Augmentation Of Water Supply Of Mohalla Basooni Dharana

Issued by Government Departments · Poonch, Jammu and Kashmir
Tender Value
23.41 Lakhs
Estimated cost
Bid Submission
16 Oct 2026
0 days left
EMD
46820
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvement Strengthening And Augmentation Of Water Supply Of Mohalla Basooni Dharana

BOQ

Name of Work:- Improvement Strengthening and augmentation of water supply of Mohalla Basooni Dharana
Sl. No. Item Description
1Pipes Works
2Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m inwidth) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil
3Refilling of Excavated soil back into trunches
4Providing and Laying / Fititng of G.I Pipes 65mm Dia (M)
5Carriage of G.I Pipes for average 1.50 Km by HL
6Welding of Joints bt Electric arc Welding including testing and commissioning of joints includes carriage if set and all other accessories including making arrangement for electric supply /arrangement for generator etc. Complete job
7Providing and Fixing of GM gate valve of approved Quality 20mm
8Providing and Fixing of GM gate valve of approved Quality 25mm
9Providing and Fixing of GM gate valve of approved Quality 32mm
10Providing and Fixing of GM gate valve of approved Quality 40mm
11Providing and Fixing of GM gate valve of approved Quality 50mm
12Providing and Fixing of GM gate valve of approved Quality 65mm
13Providing and Fixing of GM gate valve of approved Quality 80mm
14Mechanical Work
15(I)Providing, Installation, Testing & Commissioning of 4000 GPH x 150 MtrHead as per IS reputed make Submersible Pump set with standby The Pump bowl should be of close grained cast iron with renewable wearing rings of bronze material. The Pump shaft shall be of stainless steel, guided with stainless steel distance sleeves /shaft protection sleeves provided with each bowl above and below the stainless steel impeller. The Casing wearing rings shall be of bronze material. The Coupling shall be of Mesh type rigid sleeve of stainless steel, non-slipping type with matching groove and cotter arrangement to suite keyway provided. The Suction case shall be of close grained cast iron material. The motor should be three phase AC supply having nominal speed of 2900 RPM, 400 Volts + 15% of frequency 50 Hz + 3%. The motor should be totally enclosed squirrel cage induction type, water cooled and sealed against outside water being pumped. The windings shall be wet type water lubricated and provided with metal tilting thrust pad designed to take up all untoward load to most unfavourable running conditions. The upper chamber of the submersible pump shall be duly fitted with an NRV so that during stoppage of submersible pump set reverse water cannot operate the pump set in reverse rotation. The Job also includes fabrication and providing of 80 mm dia. M.S column pipes- 22 nos. -03 Meter length each piece duly welded at both ends and attached with MS flanges-02 nos. to each pipe and all the column pipes shall be properly painted by using two coats of anti-rust primer and two coats of super enamelled black paint. Providing and welding suitable M.S flanges with 04 nos. hole on each side of column pipe with proper alignment strengthening of each flange with column pipe by providing and welding of 04 nos., angular cleats at each end. Making two nos. grooves on each flange to accommodate submersible cable. The top column pipe shall be fabricated by providing one number, 12 mm thick M.S Flange of size 350 mm dia on one side so as to rest the complete connected column pipes with 01 Job 18.0 18.0 submersible pump motor set on casing pipe in tube well. The casing pipe shall be provided with a cut of for keeping a provision of submersible cable one end of the top column pipe shall be provided and welded with 80mm dia M.S bend with proper flanges with suitable no. of holes for fitment of sluice valve/reflex valve in bore well. Fabrication of two sets of M.S Clamps set suitable for column pipe with proper tempering and no slipping mechanism in bore well. The job involves fabrication of adopter Nipple/reducer nipple approx. 0.5 mtr long fabricated out of MS Pipe, of which bottom end diameter is to be reduced to the delivery of Sub. Pump and threading the Pipe for screwing into the delivery portion to the submersible pump and other end of the adopter nipple is welded with MS flange of required size fabricated out of MS Plate for fixing with the column pipe. Two number nuts of required size are to be welded on opposite size of the proper piece so that clamping bolt of the tie rod can passed through it. Fabrication of the tie rod clamping arrangement for clamping the pump and motor to the upper adopter nipple, fabricated out of 40mmx6mm MS Plate as per required size at site. The upper ends of these flat strips should be welded with full threaded bolt 12mm dia. and 10 cm long. These bolts are to be passed through the nuts welded on the adopter nipple piece, tightening of the 12 mm double nuts on both sides including cost of material and labour charges. The Job includes coupling of both pumps and motors properly checking of movement of the pump, tightening of the adopter nipples to the delivery side of both the pumps,tightening of tie rods and testing of both the pump sets in the testing pit at workshop. Shifting of the submersible pump to work site. Providing and fitting of 16 sq mm submersible cable as per site requirement after crimpling, thimbling patching, taping etc. Lowering of submersible pump set into the borewell along with the column pipes by using special tools and tackles. Making all electrical connections of Submersible Pumpset with LT control panel by proper thimbling and crimpling all cable ends and then testing and checking for specified amperage on fullload.(II)Fabrication ,providing and fitting of MUG-30 -01 no.MU-G30 FASD — 30 HP Fully Automatic Star-Delta StarterMake: Lauritz Knudsen Electrical & Automation (formerly L&T Switchgear)Model: MU-G30 FASDApplication: 30 HP, 3-phase submersible/open-well/industrial pump motorStarter Type: Fully Automatic Star-Delta Starter (FASD)Motor Rating: 30 HP / approximately 22 kWRated Supply: 415 V AC, 3 Phase, 50 HzCoil Voltage: 380 V ACCurrent/Overload Relay Range: 30–50 ARated Insulation Voltage: 690 VRated Impulse Withstand Voltage: 8 kVStandard: IS/IEC 60947-4-1Protection: Single-phase prevention, phase-failure protection, phase/supply-voltage unbalance protection and overload protectionMetering: Combined volt-ammeter for monitoring voltage and currentStarting Method: Automatic Star-DeltaApplication: Suitable for heavy-duty water-pumping applications, including borewell and open-well pumpsOperating Temperature: Approximately −5°C to +55°CConstruction: Complete factory-assembled automatic starter/controller with required contactors, protection, control circuit and accessoriesApprox. Dimensions: 526 × 187 × 572 mm (to be confirmed against the manufacturer's current datasheet(III)Fabrication of Gantry. The job further includes Design, fabrication and erection of MS/G.I Pipe Gantry for extraction and lowering of submersible pump set along with column pipes. The job includes fabrication of 2 nos vertical members of MS/G.I Pipes 6” dia medium class each of height 15 ft. embedded in cement concrete block of 3’x 3’x3’ from bottom of the vertical column pipes 2 nos. It includes earth work for excavation of foundation of size 3’ x 3’ x 3’ of cement concrete block for embedding of foot of vertical column. Cast of cement concrete block in 1:2:4 mix of size 3’ x 3’ x 4’ (1’ AGL). Providing and embedding of 4 nos foundation bolts of size 2’ x 16mm in each block. The job also includes providing and fitting of 02 nos MS plates 8 mm thick of size 2’x2’ welding of 4 nos ribs at the base of the column pipes and 02 nos MS plates 8 mm thick of size 1’x1’ at the top of column pipes, welding of 4 nos ribs at the base of the vertical column pipes for strengthening of vertical column pipes, placing/welding of horizontal 4”dia- 8 ft pipe above the column vertical pipes. The job also includes providing and welding of main cross member made out of 4” dia M.S/G.I Pipe – 1.5 mtrs medium class on top. Making of one number MS steel ladder on side of vertical pipe fabricated out of MS angle (1.5’ length) of suitable size and shall be welded properly at an equidistant of 1’ each from bottom to top of the MS column pipe. The job also includes painting of the pipes by way of making surface smooth emery paper and initially giving one coat of red oxide and finally two coats of black enamel paint for smooth finish.
16Borewell
17Setting up of drilling site by way of shifting of machinery and allied material after making proper approaches as per requirement at site
18Deep drilling of bore hole 200mm dia. Upto 140 mtrs below ground level or above as per strata encountered till sufficient aquifer Zone/discharge is encountered by using ODEX method and simultaneously driving of 200 mm dia ERW casing pipe after providing fixing of casing drive shoe with first 200 mm dia casing pipe complete as per IS: 2800 (Part I),including collecting sample for different strata including hire and running charges of all equipment tools plants and machinary required for job,all complete as per direction of Engineer-in-charge.
19Cost of MS Pipe assembly (including welding) lowering and fixing in vertical position in bore well ERW 200 mm dia FE 410 beveled ended MS Casing pipe,conforming to IS 4270 of reputed & approved make,including painting with two coat inner and outer of anti corrosive paint of approved brand including loading unloading and transportation of M.S Casing pipe upto location of borewell as per direction of Engineer-in-charge.
20Development to tubewell in accordance with IS: 2800 (Part I) and IS : 11189 to establish maximum rate of usable water yield without sand content with air compressor,running of compressor till well is fully developed measuring yield of well by \\"v\\" notch method or any other method taking water sample and getting tested in approved laboratory,I/C disinfection of tubewell all completed including hire and labour charges of air compressor tools and accessories etc as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57970369
AUTHORITY Government Departments
TENDER VALUE 23.41 Lakhs
LAST DATE 16-10-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Improvement Strengthening And Augmentation Of Water Supply Of Mohalla Basooni Dharana
Basic Detail
Tender No enit no 06 of 2026_27
Bidding Type Tender
Location
City Poonch
State Jammu and Kashmir
Key Dates
Publish Date 10 Oct 2026
Submission Date 16 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value 23.41 Lakhs
Tender Fee 800
EMD 46820
Exemption Not Available
Document List
49a8ecb5-d93c-475f-912c-9d28ef3271a0.html
BOQ_1108940.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

49a8ecb5-d93c-475f-912c-9d28ef3271a0.html

xls

BOQ_1108940.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender