Tender For Provision Of Guard Room Near Engr Regt Under Age B/R Of Ge (P) Nagrota
Tender Value
31.55 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
1 days left
EMD
63100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota/ JAMMU → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Guard Room Near Engr Regt Under Age B/R Of Ge (P) Nagrota
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Oct-2026 | Amendment in BOQ and tender document and index page | BOQ | 31-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BR PORTION Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out any kind of soil complete all as specified and directed by Engineer-in-Charge. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out any kind of soil complete all as specified and directed by Engineer-in-Charge. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting outgetting out any type of soil complete all as specified & directed by Engr-in-Charge. |
| 4 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge. |
| 5 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep in soft/disintegrated rocks getting out and levelling of bottom surface to required level complete all as specified and directed by Engineer-in-Charge. |
| 6 | M&L Cement concrete Type D2 1:4:8 (40mm graded crushed aggregate) in foundations,filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 7 | RCC (Design mix) M-25 for Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. |
| 8 | RCC (Design mix) M-25 for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge. |
| 9 | RCC (Design mix) M-25 for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified and directed by Engineer-in-Charge. |
| 11 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where complete all as specified and directed by Engineer-in-Charge. |
| 12 | Removing excavated material exc. 50mtr and up to 150 mtr and depositing where directed at a level n exc. 1.5 mabove the starting point complete all as specified & directed by Engr-in-Charge. |
| 13 | M&L for removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 14 | M&L for formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge. |
| 15 | Rough finished surfaces of concrete flat formwork Square, Circular rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer-in-Charge. |
| 16 | Rough finished surfaces of concrete flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge. |
| 17 | Rough finished surfaces of concrete flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge. |
| 18 | Rough finished surfaces of concrete flat formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and directed by Engineer-in-Charge. |
| 19 | Mild steel bars 10mm dia and over, cut to length, bent to shape required, ncluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 20 | Mild steel bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, ncluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for brickwork with sub class \\"B\\" bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified & directed by Engr-in-Charge. |
| 23 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L 2nd class HW 35mm thick flush shutters, solid core construction, but with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge. |
| 25 | S&F for pressed steel frame for door with two rebate incl necessary fixing lugs,hold fast,hings,lock strike plate including for one shop coat of priming complete all as specified of size 105x60mm incl filling PCC 1:3:6 Type C0 (12.5mm graded aggregate) complete all as specified and directed by Engineer-in-Charge. |
| 26 | S&F for pressed steel frame for door with two rebate incl necessary fixing lugs,hold fast,hings,lock strike plate including for one shop coat of priming complete all as specified of size 125x60mm incl filling PCC 1:3:6 Type C0 (12.5mm graded aggregate) complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F for solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F for factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face with particle board Core , supplying & fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F for factory made, single piece wire guazed panel HDF door shutter 35mm thick (style) with 2, 4 or 6 raised panel design including GI wire gauge complete supplied & fitted in the frame at site as per specification complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F for box type steel window frame with side hung double shutter with provision for desert cooler / AC (inside for wiremesh & out side for glass) including guard bar, hinges, steel, handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing and fixed steel window shall be conforming to relevant IS complete all as directed (Note : Wire mesh and sheet glass shall be meaured and paid separately). |
| 31 | S&F for sheet glass 4mm thick ordinary qaulity and glazing with oil putty in sqaures n exc 0.5 sqm each panes etc complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F for 150mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F 100mm mild steel butt hinges, medium weight, cold rolled and fixed complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F 150mm long aluminium handles cast type, anodised and fitted complete all as specified and directed by Engineer-in-Charge. |
| 36 | S&F 300mm long ordinary MS rat tail rod pattern springs incl roller and roller plate complete all as specified and directed by Engineer-in-Charge. |
| 37 | S&F for box type steel ventilators frame with top hung double shutter with frame (inside for wiremesh & outside for glass), incl guard bar, hinges, steel handle tower bolt and steel peg stay complete with glazing bar dovbetailed or welded including a coat of red oxide after preparation of surface before fixing, steel ventilators shall be conforming to relevant IS complete and directed (Note : Wire mesh and sheet glass shall be meaured and paid separately). |
| 38 | M&L two coats of synathetic enamel paint over a coat of pink primer on new wood or wood surfaces, over 10 cm width or girth incl preparation of surfaces. Complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L two coats of synathetic enamel paint on new steel surfaces, over 10 cm width or girth incl preparation of surfaces. Complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F for mild steel drapery rod 25mm dia plastic coated fixed on wall including providing rings through out the length at some intervals complete all as specified and directed by Engineer-in-Charge. |
| 41 | S&F for mild steel brackets powder coated at both ends to hang curtain rod and colour complete all as specified and directed by Engineer-in-Charge. |
| 42 | S&F for PVC ball shaped knobs at both end of curtain rod and colour complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 45 | Rendering 5mm thick on fair faces of brick work or concrete surfaces cement mortar 1:3 without using extra cement complete all as specified |
| 46 | M&L for preparing new plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed by Engineer-in-Charge. |
| 47 | M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer incl 3mm thick wall care putty complete all as specified and directed by Engineer-in-Charge. |
| 48 | M&L preparing new plastered surfaces of ceiling, chajjas facia etc. and applying three coat of white wash complete all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for 100mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in flooring complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for 100mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in flooring complete all as specified and directed by Engineer-in-Charge. |
| 51 | M&L Machine cut kota stone slab (single piece using in treads) flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, cutting in square or rectangular and polishing including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 52 | M&L Kota stone slab for skirting, dado and pillar laid over cement screed and jointed including rubbing, cutting in square or rectangularand polishing including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 53 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 54 | M&L glazed, coloured, ceramic, tiles of size (350x250x7mm/300x450x7mm thick), on vertical surfaces, such as skirting, dadoes, etc set and jointed in neat cement slurry and pointed in coloured cement to match with the surface over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 55 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade A complete all as specified and directed by Engineer-in-Charge. |
| 56 | M&L for PCC 1:3:6 type C2 (75 mm thick as in plinth protection & finishing the surface even & fair W/o using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 57 | M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface Broken stone or boulders |
| 58 | M&L for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including provision of lean concrete bedding connection to drain out pipe, to flush pipe and antisyphonage pipe etc, complete all as specified and directed by Engineer-in-Charge. |
| 59 | M&L for 10 Ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets for fixing to wall, Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed by Engineer-in-Charge. |
| 60 | M&L for vitreous Cliina wash basin, white, flat back, size 580x450 iron excluding taps, waste, chain and plug and porcelain stopper but including brackets for fixing to wall , 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F wall mounted soap dish holder fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F 15 mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 65 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth. (in brick walls) complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F for 20mm dia GI tubing medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed by Engineer-in-Charge. |
| 67 | S&F for bib tap fancy type 15mm dia cast copper alloy chromium plated with capstan handle screwed down for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 69 | S&F angle cock/ stop valve cast copper alloy 15mm dia fancy type chromium plated, with long shank and cup (concealed type) screwed down, high pressure, with capstan handle screwed both ends for iron pipes or for unions all as specified and directed |
| 70 | Supply and fixing 50mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/ cm2 fixed complete to walls, ceilings or floors including elbows, unions, tees, reducing tees, adoptors, sokets, plug house clips etc and fixing to walls etc complete with saddles (snap clips), wall clips hooks complete all as specified and directed. |
| 71 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 72 | S&F glass corner shelf of 300mm long complete all as specified and directed by Engineer-in-Charge. |
| 73 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-Charge. |
| 74 | S&F brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge. |
| 75 | S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engineer-in-Charge. |
| 76 | S&F 1000 Ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge. |
| 78 | M&L for 10 mm rendering in CM 1:4 mixed with water proofing compound @2% of cement over roof surfaces finished even and smooth without using extra cement complete all as specified Note:- WPC Mesured and Paid Separately. |
| 79 | Supplied only liquid water proofing compound ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 80 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) 50mm thick as in roof padding finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 81 | M&L for applying evenly a tack coat of induatrial bitumen 85/25 grade @ 1.2 Kg/Sqm including bitumen primer @ 3.50 Kg/Sqm over plaster surfaces of roof complete all as specified and directed by Engineer-in-Charge. |
| 82 | M&L for laying APP (atatic polypropylele) modified membrance 3mm thick and weight not less than 3.00 Kgs per Sqm with 160 GSM/Sqm non woven polyester mat as centre core reinforcement laid with 75mm side over lap and 100mm end lap the membrane has to be laid with LPG tourch and over lap sealed and finished neat over roof including a coat of bitumen 85/25 at the rate of 1.2 Kg per sqm over APP membrane and grouting with mixture of white cement and marble powder over roof complete all as specified and directed by Engr-in-Charge. NOTE : S&F of APP based polimeric membrane of approved manufacturer will be laid/fixed by authorised person of the same manufacturers units asper relevent IS. |
| 83 | S&F Precast factory made plain cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors jointed and pointed with grey cement and pigment including screed bed or bedding layer of mortar 15 mm thick in CM (1:4) complete all as specified and directed by Engineer-in-Charge. |
| 84 | M&L for Cast iron cowl for 50mm bore pipe complete all as specified and directed by Engineer-in-Charge. |
| 85 | M&L for Cast iron soil, waste and vent pipes (Sand cast) in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed 50mm bore |
| 86 | M&L for Cast iron soil, waste and vent pipes (Sand cast) in any length with or without ears, with cement joints, fixed to walls, complete all as specified and directed 100mm bore |
| 87 | M&L for Cast iron soil, waste and vent pipes (Sand cast) in any length, with or without ears, with cement joints laid in trenches or in floors, complete all as specified and directed 100mm bore |
| 88 | M&L for Cast iron soil, waste and vent pipes (Sand cast) in any length, with or without ears, with cement joints laid in trenches or in floors, complete all as specified and directed 75mm bore |
| 89 | M&L for Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured,for pipes of bore 50mm complete all as specified and directed |
| 90 | M&L for Cast iron sanitary connection socket to fit WC out-let for pipes of bore 100mm complete all as specified and directed |
| 91 | M&L for branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors, for pipes of bore 100mm complete all as specified and directed |
| 92 | M&L for Bends (any radius), diminishing pieces or tapers (larger bore measured), for pipes of bore 100mm complete all as specified and directed |
| 93 | M&L for Cast iron bends (any radius) with duck's foot or heel rest, for pipes of bore 100mm, complete all as specified and directed. |
| 94 | M&L for Cast iron Floor trap with stainless steel grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) with cement joint, dia of outlet 75mm, complete all as specified and directed. |
| 95 | M&L for Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured),for pipes of bore 75mm complete all as specified and directed |
| 96 | M&L for Salt glazed stoneware Gully trap, square or round mouthed, type 'P', 150mm x 150mm, set and jointed to drain pipe in CM 1:1 complete including excavation and earth work in any type of soil, concrete bed in PCC 1:2:4 type B-1, surrounds, kerbs, etc. and cast iron grating, complete all as specified and directed. |
| 97 | M&L Stack clamps for 100mm bore out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 98 | M&L Stack clamps for 50mm bore out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 99 | M&L for providing lead joints for 100mm dia in lieu of cement joints for pipes embedded in masonry or concrete complete all as specified and directed. |
| 100 | M&L for providing lead joints for 75mm dia in lieu of cement joints for pipes embedded in masonry or concrete complete all as specified and directed. |
| 101 | M&L for cement Concrete bed Type D2 1:4:8 (40mm crushed stone graded aggregate), to 100mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 102 | S&F 15mm bore brass CP mixer for mixing hot & cold water screwed down for iron pipe for bath & WHB and fixed Complete all as specified and directed. |
| 103 | S&F 15mm Bore brass chorominum plated shower rose 125mm size with or without swivel joints any size including fixing to steel pipe or union complete all as specified and directed. |
| 104 | S&F 15mm bore stop/angle valve cast copper alloy fancy type chromonium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. |
| 105 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwedboth ends for iron pipe and fixed complete all a sprecified and directed |
| 106 | M&L PCC 1:2:4 Type B1 (using 40mm graded aggrgate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified & directed by Engr-in-Charge. |
| 107 | M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified & directed by Engr-in-Charge. |
| 108 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2021 of 60 mm thickness, M-35 Grade With Grey Cement and pigment complete all as specified & directed by Engr-in-Charge. |
| 109 | M&L Concrete bed cement concrete 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) to drain pipe of 150mm bore incl packing under and completely srrounding pipes with concrete after they are laid and tested, complete all as specified & directed by Engr-in-Charge. |
| 110 | M&L 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified & directed by Engr-in-Charge. |
| 111 | Supply only integral water proofing compound ISI Marked complete all as specified & directed by Engr-in-Charge. |
| 112 | M&L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping etc. including necessary formwork all as specified and directed. |
| 113 | M&L RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in Man hole cover etc. including necessary formwork all as specified and directed |
| 114 | Precast cement concrete 1:3:6 type C-1 using 20mm greaded crushed stone agg in manhole channel complete all aspecified and directed. |
| 115 | Extra for forming fair finished drain or channel exc 30 cm inner girth in cemernt concrete , using extra cement including forms, moulds, mittered/stoped ends etc complete all as specified and directed. |
| 116 | S&F LLDPE septic tank designed to carry sewage and sludge water, comprising earth work , excavation in any type of soil, returning filling, disposal of surplus spoils to a distance not exc 50 mtr from starting point in any type of soil, PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundation, 200mm thick, vent shaft, connections etc.for 20 users including all fittings, fixtures, testing on completion complete all as directed and specified by Engr-in- Charge. |
| 117 | M&L Soakage well 1.8 mtr dia and 3.00 m effective depth ,excavation in any type of soil, foundation in PCC 1:3:6 wall of honey combed masonary with top ring of M-25 (Design Mix) including intercepting chamber and screen chamber made of brick masonary in cement mortar (1:4), RCC cover slab of RCC M-25 (Design Mix)/SFRC cover, intercepting pipes of RCC/ DWC complete filled with bricks bats, complete all as directed and specified by Engr-in- Charge. |
| 118 | EM PORTIONS&F cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor of size 2 core 10 Sqmm. |
| 119 | M&L for DWC pipe for cable protection of ID 32 mm complete with all fitting complete all as specified and directed by Engineer-in-Charge. |
| 120 | Supply and Laying Tubes (Pipe), 'medium grade', galvanised, with all fitting;laid in trenches including fitting 25 mm dia complete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply and fix Gun Metal, globe or gate valves, with iron wheel head, screwed both ends for pipe and fixed of size 25 mm |
| 122 | M& L for cutting of existing pipeline upto 150 mm dia for taking branch connection alongwith insertion of CI/GI Tee and connecting material such as joint, nut bolts, etc all as required at site. |
| 123 | M&L for Point wiring for One light point (T/L, Batton Hoder, Mirror Light, Bldg Sec Light & Bulk Head) controlled by one switch 5 Amp SP one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including PVC concealed conduit (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including suitable size Modular MS sunken box for fixing of modular switches,sockets,regulators with frame and top white cover plate and machine made brass screw and washers etc complete all as specified and directed for one light point controlled by one one way switch. |
| 124 | Description all as per item No - 123 above but for one ceiling fan/exhaust fan point. |
| 125 | Description all as per item No - 123 above but for one 3 pin 5 amp socket on same board all as directed. |
| 126 | Description all as per item No - 123 above but for one 3 pin 5 amp socket on indipendant board all as directed. |
| 127 | Description all as per item No - 123 above but with 2.5 sqmm copper conductor for 15 amp socket with 2.5 sqmm earth continuity conductor |
| 128 | S&F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified and directed by Engineer-in-Charge. |
| 129 | S&F Modular socket 3 pin 5/6 Amps suitable for 2 Module complete all as specified and directed by Engineer-in-Charge. |
| 130 | S&F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified and directed by Engineer-in-Charge. |
| 131 | S&F Modular socket 5 pin 15/16 Amps suitable for 2 Module complete all as specified and directed by Engineer-in-Charge. |
| 132 | S&F ceiling rose surface backalite three terminals complete all as specified and directed by Engineer-in-Charge. |
| 133 | Supply and fix lamp holder insulated body with back plate suitable for any type of fitting all as specified and directed. |
| 134 | Supply and fixing LED Batten lights fttings 1 x 20Watt, 220V, AC complete all as specified and directed by Engineer-in-Charge. |
| 135 | Supply and fixing LED Batten 5 Watt cool white tube light with 500 Lumen for bathroom mirror fitting all as specified and directed. |
| 136 | Supply and fix LED lamp 9 Watt acomplete all as specified and directed by Engineer-in-Charge.. |
| 137 | Supply and fixing LED bldg Security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and directed by Engineer-in-Charge. |
| 138 | Supply and fixing ceiling fans complete with blades, down rods, Fan Regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge. |
| 139 | Supply and fix electric water heater,storage type steel body with steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed by Engineer-in-Charge. |
| 140 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by Engineer-in-Charge. |
| 141 | Supply and fix Wall fan made plastic body complete, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 400 mm complete all as specified and directed by Engineer-in-Charge. |
| 142 | S & F sheet metal enclosure for DB's , MCB DB SPN 8 way double door complete all as specified and directed by Engineer-in-Charge. |
| 143 | Supply and fixing MCB SPN 240 Volts 32 Amps complete all as specified and directed by Engineer-in Charge. |
| 144 | Supply and fixing MCB SP 240 Volts 5 Amps to 32 Amps complete all as specified and directed by Engineer-in Charge. |
| 145 | S&F Sub main wiring with PVC insulated, FRLS cable 2 single core 6 Sq mm 1100 V grade with stranded copper conductor on and incl PVC rigid non metalic conduit (ISI marked) in concealed incl all specials like joint, elbow , Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 6 sq mm for earth continuityconductor complete all as directed by Enginer-in-charge. |
| 146 | Earthing complete with GI earth plate 60cm ×60cm ×6 mm thick electrode buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth wire lead 4 mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of SSR Part-I connected to continuous earth wire on earthing point all as specified and testing on completion, including provision of GI earth lead wire protected by 15 mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 19, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 31, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender