Chemicals and Fertilizers Boards / Undertakings / PSU Closing in 3 days TDR #57969322

Tender For Repairs Of Sewerage System In Rcf Township In Rcf Estate At Chembur, Mumbai - 400074Notes: 1) Kindly Read All The Pages Of Nit & Special Conditions Before Quoting For This Work. The Party Shall Visit The Site Before Quoting To Access The Q

Issued by Boards / Undertakings / PSU · Mumbai Suburban, Maharashtra
Tender Value
87.68 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
3 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai Suburban → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs Of Sewerage System In Rcf Township In Rcf Estate At Chembur, Mumbai - 400074Notes: 1) Kindly Read All The Pages Of Nit & Special Conditions Before Quoting For This Work. The Party Shall Visit The Site Before Quoting To Access The Quantum And Nature Of The Job.

BOQ

Name of Work:- Repairs of Sewerage system in RCF Township in RCF Estate at Chembur, Mumbai – 400074NOTES: 1) Kindly read all the pages of NIT & special conditions before quoting for this work. The Party shall visit the site before quoting to access the quantum and nature of the job.
Sl. No. Item Description
1Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 and above in foundation, plinth & superstructure in:Cement mortar 1:3 (1 cement : 3 coarse sand)
2Providing and applying 20mm thick external sand faced cement plaster with neat cement rendering upto any height and at all locations in cement mortar proportion specified below in two coats for masonry (except stone masonry) and concrete surfaces including providing waterproofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete as directed By Engineer In Charge. Min. time lag between two coats shall be 24 hours.(as per IS2402 of 1963.) In cement mortar 1:3.
3Providing and applying 12 mm thick internal plaster in cement mortar 1:3 finished smooth with a floating coat of neat cement at all heights and locations in one coat for masonry (except stone masonry) and concrete surfaces including racking out joints, hacking of concrete surface, watering, finishing, curing, scaffolding etc. complete.
4Providing and laying in position plain cement concrete of specified grade with trap/granite/ quartzite /gneiss metal mixing in concrete mixer including bailing out water, compacting, finishing surface with neat cement float, curing and including the cost of centering and shuttering at all level : Nominal Mix of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5Providing and laying in position plain cement concrete of specified grade cement with trap/granite/quartzite/gneiss metal mixing in concrete mixer including bailing out water, compacting, finishing surface, curing and including the cost of centering and shuttering at all level : Nominal Mix of 1:3:6 (1 Cement OPC: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
6Providing and laying Indian patent stone flooring 40mm thick with M-15 grade concrete using 6mm to 20mm metal over bedding laid in proper grade and slope or over the slab, including compaction, marking lines, to give appearance of tiles as per the approved pattern, finishing smooth with cement slurry as mentioned below, curing etc. complete. In plain natural/ grey colours.
7Providing and fixing UV resistant selffit UPVC pipes of approved make for Rainwater downtakes confirming to IS 13592:1992 Type A suitable for 4kg/sqcm pressure for following pipe diameters including rain water receiving recess with pvc plug bend necessary fittings such as offsets shoes, fixing the pipes on wall with clips filling the joints with solvent/cement and necessary scafolding etc. complete as directed by Engineer In Charge. 100mm dia.
8Providing and fixing UV resistant selffit UPVC pipes of approved make for Rainwater downtakes confirming to IS 13592:1992 Type A suitable for 4kg/sqcm pressure for following pipe diameters including rain water receiving recess with pvc plug bend necessary fittings such as offsets shoes, fixing the pipes on wall with clips filling the joints with solvent/cement and necessary scafolding etc. complete as directed by Engineer In Charge. 150mm dia.
9Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
10Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
11Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 600 mm dia. R.C.C. pipe
12Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1000 mm dia. R.C.C. pipe
13Providing and fixing in position precast RCC manhole covers, of size 900mm x 450mm x 75mm at suitable location as per direction of Engineer-in-charge.
14Providing and fixing in position precast RCC manhole covers, of size 900mm x 600mm x 75mm at suitable location as per direction of Engineer-in-charge.
15Providing and fixing in position precast RCC manhole covers, of size 1200mm x 450mm x 75mm at suitable location as per direction of Engineer-in-charge.
16Providing and fixing RCC cement concrete cover over gully trap of size 20 cm x 30 cm.
17Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site, depositing in Township Civil Store and disposal of unserviceable materials within RCF Estate :100 mm diameter
18Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site, depositing in Township Civil Store and disposal of unserviceable materials within RCF Estate :150 mm diameter
19Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site, depositing in Township Civil Store and disposal of unserviceable materials within RCF Estate :200 mm diameter
20Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site, depositing in Township Civil Store and disposal of unserviceable materials within RCF Estate :250 mm diameter
21Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site, depositing in Township Civil Store and disposal of unserviceable materials within RCF Estate :300 mm diameter
22Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 100 mm diameter
23Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter
24Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter
25Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 250 mm diameter
26Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 300 mm diameter
27Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all- round S.W. pipes including bed concrete as per standard design:100 mm diameter S.W. pipe
28Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all- round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe
29Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all- round S.W. pipes including bed concrete as per standard design :200 mm diameter S.W. pipe
30Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all- round S.W. pipes including bed concrete as per standard design :250 mm diameter S.W. pipe
31Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all- round S.W. pipes including bed concrete as per standard design :300 mm diameter S.W. pipe
32Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe
33Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe
34Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :200 mm diameter S.W. pipe
35Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :250 mm diameter S.W. pipe
36Providing and laying cement concrete 1:4:8 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :300 mm diameter S.W. pipe
37Providing & fixing open half-round S.W. pipe above 75 mm, upto 150 mm channel filled in cement and sand mortar 1: 2 above.
38Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: For pipes 100 to 250 mm diameter
39Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: For pipes above 250 to 300 mm diameter
40Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: For pipes 350 to 450 mm diameter
41Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
42Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
43Uncoursed rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).
44Providing raised and cut pointing to any kind of stone masonry work at all heights and locations in cement mortar 1:2, including raking of joints upto the depth of 20mm, finishing, curing, cleaning the surface etc. complete as directed by Engineer in Charge.
45Excavation for foundations, substructures, basements, tanks, sumps, walls, chambers, manholes, trenches, poles, pits & general building works works in all types of soils, vegetable earth, soft murum, running sand, shingle, turf clay, loam, peat, ash, shale, slag, chalk, garbage, muddy/ marshy/ slushy soil, marine clay, reclaimed land etc. for depths/lifts upto 1.5M measured from the ground level, including dressing/ trimming the sides, leveling and ramming of bottoms, manual dewatering, removing rank vegetation as directed.
46Extra over above excavation item for lift from 1.5m to 3.0m.
47Dewatering the excavated trenches/pits, pools of water, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge including cost of machinery, labour, fuel, pipe and it's accessories etc. complete. Rate is number of hours for HP/Hr.
48Demolishing brick work in lime or cement mortar including plaster, paint, etc. manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
49Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved.
50Supply of skilled labours with tools & tackles for odd & unmeasurable work.
51Supply of unskilled labours with tools & tackles for odd & unmeasurable work.
52Systematically cleaning / functioning / non-functioning sewer of 150 mm dia to 230 mm dia sewer by passing ropes knots, bamboo kamti and disc. of required size as directed and specified including safety measures such as tests for gases, use of safety belts, drycell, torches, or lighting in manholes & drains as directed.
53Systematically cleaning / functioning / non-functioning open drain of any width as directed and specified including safety measures such as tests for gases, use of safety belts, drycell, torches, or lighting in manholes & drains as directed.
54Systematically cleaning / functioning / non-functioning sewer of 300 mm dia to 600 mm dia sewer by passing ropes knots, bamboo kamti and disc. of required size as directed and specified including safety measures such as tests for gases, use of safety belts, drycell, torches, or lighting in manholes & drains as directed.
55Systematically cleaning / functioning / non-functioning sewer of 700 mm dia to 1200 mm dia sewer by passing ropes knots, bamboo kamti and disc. of required size as directed and specified including safety measures such as tests for gases, use of safety belts, drycell, torches, or lighting in manholes & drains as directed.
56Systematically cleaning of sewarage chambers of depth upto 2 M in sewerage system by removing of muck as directed including pumping out liquid waste or sewage/plugging or diverting the flow in the drain if necessary. This also includes taking necessary precautionary safety measures such as test for gases use of safety belts, dry cell torches for lighting in manholes and drains etc. complete including, sprinkling, bleaching powder on the silt removed to avoid bad smell as directed and disposal within lead of 300 M. If material is shifted for distance more than this lead then it will be paid under transporation item.
57Systematically cleaning of Gully chamber/kitchen chamber in sewerage system by removing of muck as directed including pumping out liquid waste or sewage/plugging or diverting the flow in the drain if necessary. This also includes taking necessary precautionary safety measures such as test for gases use of safety belts, dry cell torches for lighting in manholes and drains etc. complete including, sprinkling, bleaching powder on the silt removed to avoid bad smell as directed and disposal within lead of 300 M. If material is shifted for distance more than this lead then it will be paid under transporation.
58Systematically cleaning of manholes of any depth in sewerage system by removing of muck as directed including pumping out liquid waste or sewage/plugging or diverting the flow in the drain if necessary. This also includes taking necessary precautionary safety measures such as test for gases use of safety belts, dry cell torches for lighting in manholes and drains etc. complete including, sprinkling, bleaching powder on the silt removed to avoid bad smell as directed and disposal within lead of 300 M. If material is shifted for distance more than this lead then it will be paid under transporation item.
59Hydraulic Excavator (3D) with driver and fuel (JCB) (per day)
60Diesel Truck - 9 tonne (per day) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57969322
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 87.68 Lakhs
LAST DATE 31-10-2026
Authority
Authority Name Rashtriya Chemicals And Fertilizers Limited
Work Description Tender for Repairs Of Sewerage System In Rcf Township In Rcf Estate At Chembur, Mumbai - 400074Notes: 1) Kindly Read All The Pages Of Nit & Special Conditions Before Quoting For This Work. The Party Shall Visit The Site Before Quoting To Access The Quantum And Nature Of The Job.
Basic Detail
Tender No E 9567 TROM/2908/OPEN(TCM)/14/2026
Bidding Type Tender
Location
City Mumbai Suburban
State Maharashtra
Key Dates
Publish Date 10 Oct 2026
Submission Date 31 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 87.68 Lakhs
Tender Fee Ref. Documents
EMD 1.50 Lakhs
Exemption Available
Document List
BOQ_977065.xls
ee675973-188e-4726-8388-80db78805939.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_977065.xls

html

ee675973-188e-4726-8388-80db78805939.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender