Defence Statutory Bodies & Commissions/Committees Closing in 27 days TDR #57966583

Tender For Construction Of New Building For Psychiatric Ward By Demolition Of Existing Temporary Building At Af Station Jorhat

Issued by Statutory Bodies & Commissions/Committees · Jorhat, Assam
Tender Value
22.98 Crore
Estimated cost
Bid Submission
14 Nov 2026
27 days left
EMD
14.74 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jorhat → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of New Building For Psychiatric Ward By Demolition Of Existing Temporary Building At Af Station Jorhat

BOQ

Name of Work:- CONSTRUCTION OF NEW BUILDING FOR PSYCHIATRIC WARD BY DEMOLITION OF EXISTING TEMPORARY BUILDING AT AF STATION JORHAT
Sl. No. Item Description
1BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: CONSTRUCTION OF NEW BUILDING FOR PSYCHIATRIC WARD BY DEMOLITION OF EXISTING TEMPORARY BUILDING AT AF STATION JORHAT Contract No: CE(AF)SZ/JOR/ OF 2026-2027 File No: 88655/JOR/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES
2Sch 'A' Part-I (BUILDING WORK)Details of prepriced Schedule is given in tender documents
3Total amount of Such 'A' Part-II (SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)Details of prepriced Schedule is given in tender documents
4Total amount of Such 'A' Part-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
5Total amount of Such 'A' Part-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
6Total amount of Such 'A' Part-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents
7Total amount of Such 'A' Part-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
8Total amount of Such 'A' Part-VII (AREA DRAINAGE )Details of prepriced Schedule is given in tender documents
9Total amount of Such 'A' Part-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
10Total amount of Such 'A' Part-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
11Total amount of Such 'A' Part-X (TERRACE FIRE WATER TANK) Details of prepriced Schedule is given in tender documents
12Total amount of Such 'A' Part-XI (RCC UG STATIC WATER TANK OF 100 KL CAPACITY) Details of prepriced Schedule is given in tender documents
13Total amount of Such 'A' Part-XII (FIRE ALARM AND FIRE FIGHTING SYSTEM)Details of prepriced Schedule is given in tender documents
14Total amount of Such 'A' Part-XIII (LIGHTENING PROTECTION)Details of prepriced Schedule is given in tender documents
15Total amount of Such 'A' Part-XIV (HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents
16Total amount of Such 'A' Part-XV (COOLING APPLIANCES)Details of prepriced Schedule is given in tender documents
17Total amount of Such 'A' Part-XVI (DEMOLITION/DISMANTLING/TAKING DOWN)Details of prepriced Schedule is given in tender documents
18SCHEDULE \\"A\\" PART -XVII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only.
19INTERNAL ELECTRIFICATIONSupply and fixing concealed MCCB distribution box, double door, vertical type, TPN, 415 V, 4 way IP 43 suitable for MCCB of 160 Amps, 4 Pole, 36 KA as incomer and MCB SP/TP as outgoing complete with suitable busbar, neutral link, earth link, complete all as specified and directed.Note: (i) MCCB/MCBs shall be measured and paid separately.(ii) Blank space shall be covered with blank plates and cost for same shall be deemed to be included in the item quoted rate.
20INTERNAL WATER SUPPLYSupply and fixing 15mm bore Central Hole Basin mixer without pop up waste system with 450mm long braided hoses, chromium plated, fancy type, screwed down high pressure, screwed for iron/PPR pipe and fixed complete all as specified and as directed.
21S&F for 15 mm bore Two-way bib cock, fancy type, CP, cast copper alloy, long shank with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and as directed.
22Supply and fixing 15mm bore sink mixer with swinging casted spout (Wall mounted model with connecting legs and wall flanges, chromium plated, screwed for iron/PPR pipe and fixed complete all as specified and as directed.
23SEWAGE DISPOSALOn site LLDPE Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft , manhole openings with cover connection etc., complete with upflow filter including media for 30 users all as per manufacturer instructions complete all as specified and directed.
24M&L for construction of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M30 concrete including intercepting chamber and screen chamber made of Brick masonary in M30/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 m dia x 4.50 m effective depth complete all as directed and shown in drawings.
25EXTERNAL WATER SUPPLYM&L for Boring of holes under road pavement , hard standing by trenches technology using ultra sound technique machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
26M&L for Construction of brick massonry valve pit chamber of inner dimension 150x150x150 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolished old valve pit complete all as specified and directed.
27M & L for Relaying and Rerouting of serviceable water supply pipe line of any type, any size and any capacity all as specified and directed. (Note:- Excavation, sand and connected items measured and paid separately under relevant items in concerned schedule).
28EXTERNAL ELECTRIFICATIONM&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.complete all as specefied and directed .
29M & L for Relaying and Rerouting after pulling out the cable from trenches/road crossing/from the circular pipe/duct etc without damaging the cable and cleaning/straightening of cable if required at site of serviceable HT/LT UG cable of any size and any capacity complete all as specified and directed. (Note:- Excavation, sand, bricks and connected items measured and paid separately under relevant items in concerned schedule).
30Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 sqmm, Indoor/Outdoor type complete all as specified and directed
31Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 to 95 sqmm,Indoor/Outdoor type complete all as specified and directed
32Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 185 sqmm,Indoor/Outdoor type complete all as specified and directed
33Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm,Indoor/Outdoor type complete all as specified and directed
34Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 300 to 500 sqmm,Indoor/Outdoor type complete all as specified and directed
35M&L for street light bracket (suitable for street light fittings in building/ poles) up to 1.5 RM , make out of GI pipe of light grade up to 40mm dia proper shaped, bend, threaded and drilling holes for wire entry and MS clamps (02 Nos) of suitable size inproper shape and sized all as specified and directed
36S & F steel tubular swaged pole swan neck type complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 meter long) factory painted red oxide paint complete all as specified and directed. Note : (i) Contractor has to bring pole in single piece factory made. Contractor has to submit the test certificate of pole. (ii) Excavation and earth work will be measured and paid separately under relevant items in concerned schedule.
37M&L for Cable Junction Boxes out door type mounted on pole by MS clamp of suitable sizes, with metric knockout for cable entry of size 16/25 Sqmm , dimension of box are 200 x 160 x 98 mm complete with terminals all as specified and directed
38M&L for PVC sheathed copper cable of 1.5 sqmm, 3 core for street light connection complete all as specified & directed.
39Supply, fixing, grouting and painting cable route indicator made up of Factory made Precast RCC slab of size 100 cm x 40 cm x 80 mm thick duly embossed with \\"MES HT Cable\\" / \\"MES LT Cable\\",Size of Cable and grouting on the route of HT/LT cable complete.Note :- (i) Unit rate of item includes excavation, PCC foundation for erection of route indicator.(ii) Slab of route indicate to be provided with min 4 Nos x 8 mm diameters TMT bars along length of slab with 7 Nos cross bar 6 mm dia in reinforcement with shuttering.(iii) Route indicator RCC slab to painting with two coat of red colour synthetic enamel paint over on one coat of white primer base all as specified and directed
40Supply installation, commissioning and testing including providing all necessary electrical connection, LT feeder panel board (CPRI Approved), outdoor type double door, factory made out of 3 mm thick MS sheet having hinge opening arrangement in front and back side and bottom frame made out of angle of size 50 x 50 x 6mm thick and 04 Nos legs 0.6 meter length with cable entry and exist circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with power coating paint ( 5 stage process) with duly fixed in ground with necessary PC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs/glands for incoming and out going cables , bolts , screws ete complete all as specified and directed by and comprising of the following accessories including taking down unserviceable LT panel box .(Note : All the internal connection connected through suitable size of copper bus bar)
41BUS BAR CHAMBER: - Copper bus bar 600 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. INCOMER :- MCCB 400 amps, 415 volt, 35 KA breaking capacity 4 pole duly connected to bus bar as incoming - 01 Nos OUTGOING FEEDERS (a) MCCB 400 amps, 415 volt, 35 KA breaking capacity 4 pole duly connected to bus bar as incoming - 02 Nos (b) MCCB 125 amps, 415 volt,16 KA breaking capacity 4 pole duly connected to bus bar - 01 Nos INDICATING DEVICES (a) Digital Multifunction meter, Model C, class 1, with relay - 01 No. Make L&T/ABB/HPL with Suitable CT and wiring.(b) Three indication lamp Neon type for three phase
42Supply installation, commissioning and testing including providing all necessary electrical connection, LT feeder panel board (CPRI Approved), outdoor type double door, factory made out of 3 mm thick MS sheet having hinge opening arrangement in front and back side and bottom frame made out of angle of size 50 x 50 x 6mm thick and 04 Nos legs 0.6 meter length with cable entry and exist circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with power coating paint ( 5 stage process) with duly fixed in ground with necessary PC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs/glands for incoming and out going cables , bolts , screws ete complete all as specified and directed by Engr-in-charge and comprising of the following accessories including taking down unserviceable LT panel box .(Note : All the internal connection connected through suitable size of copper bus bar)
43BUS BAR CHAMBER: - Copper bus bar 600 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. INCOMER :- MCCB 400 amps, 415 volt, 35 KA breaking capacity 4 pole duly connected to bus bar as incoming - 01 Nos OUTGOING FEEDERS (a) MCCB 250 amps, 415 volt, 35 KA breaking capacity 4 pole duly connected to bus bar - 02 Nos( one spare) (b) MCCB 125 amps, 415 volt,25 KA breaking capacity 4 pole duly connected to bus bar - 01 No (c) MCCB 63 amps, 415 volt, 25 KA breaking capacity 4 pole duly connected to bus bar - 02 No (one spare). (d) MCCB 32 Amp 4 pole 16 KA - 02 Nos INDICATING DEVICES (a) Digital Multifunction meter, Model C, class 1, with relay - 01 No. with Suitable CT and wiring.(b) Three indication lamp Neon type for three phase
44Earthing for internal electrification, external electrification, fire fighting and DG Set M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (copper strip upto 7.5m including testing consider in this item).
45Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI strip 32x6 mm by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 40mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completion complete all as specified and directed .
46M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6mm thick electrode and 4 mm dia galvanised iron wire as earthing lead buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 15cm below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 50cm x 50cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 18mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed.Note:- Cost of GI wire of size 4mm dia, as earthing lead and GI protection pipe from earth electrode to test point upto 7.5 m shall deemed to be included in the quoted rate.
47M&L for Earthing complete with copper earth plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 25×3mm copper strip as earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (copper strip upto 7.5m including testing consider in this item). .
48FIRE ALARM & FIRE FIGHTING SYSTEM Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and as directed.
49Supply & fixing of 4\\" by 4\\" junction box with cover any type or outlets as ordered, complete all as specified and as directed.
50Supply and fixing Flexible conduit 20 mm for fall cealing detector and response indicator complete all as specified and as directed.
51Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 1KVA complete all as specified and as directed.
52S&F Fire bucket of minimum size 7.5 ltrs complete all as specified and as directed.
53S&F Dry chemical powder ABC type (lightweight)fire extinguisher of 9 kg capacity complete all as specified and as directed.
54S&F 9 kg mechanical foam fire extinguisher (stored pressure type lightweight) complete all as specified and as directed.
55S&F CO2 type fire extinguisher of 4.5 kgs capacity ( light weight squeeze grip type) complete all as specified and as directed.
56S&F mechanical foam fire extinguisher of capacity 6 KG complete all as specified and as directed.
57S&F fire extinguisher of clean agent type of capacity 4 kg complete all as specified and as directed.
58Supply & Laying in trenches Ductail Iron (DI) flanged pipe, centrifugally cast class K-9 conforming to IS - 8329/2000 with internal matallic zinc coating and external black bituman coating suitable for flanged type joint in length of 150 mm bore complete including all jointing materials & fittings complete all as specified and as directed.
59Supply & Laying in trenches Ductail Iron (DI) flanged pipe, centrifugally cast class K-9 conforming to IS - 8329/2000 with internal matallic zinc coating and external black bituman coating suitable for flanged type joint in length of 100 mm bore complete including all jointing materials & fittings complete all as specified and as directed.
60Material & Labour for brick masonry valve pit of internal size 100cm x 100cm x 100cm suitable for sluice valves upto 150mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cement mortar 1:6 rendering in 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including necessary earth work, including MS sheet cover of thickness 3.15mm on 50X50X6.0mm angle iron framework hinges including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolished old valve pit complete all as specified and as directed.
61Supply, installation, testesting and commissioning of LT Panel board , cubicle type , floor mounted, fabricated out of 2 mm thick CRCA sheet and 50 mm x 50 mm x 6 mm MS angle iron frame work, front and back door shutters with locking arrangement and suitable holes at the rear of the bottom of the cubicle including metallic cable glands of suitable for incoming and outgoing cables and individual shutters fitted with hinges with door gasket for each feeder separately, including auto ON-OFF system for 1 No. main pumping sets and 01 Nos jockey pumping set including following fittings :-(a) Bus bar chamber with 4 Nos copper bus bar of size 32 mm x 6 mm fixed on porcelain insulators of suitable size insulated with PVC insulation tape as per colour code.(b) MCCB 250 Amps, 4 pole, 415 volts, 3 phase, 50 Hz with adjustable current 70%-100% and breaking capacity 25 KA conforming to IS-13947-II / IEC : 947 - 1 No (For incoming supply). (c ) All as per (b) above but 160 Amp 4 Pole 25 KA -1 Nos ( for electric driven main pump)(d) All as per (b) above 100 Amp TP, 25 KA - 1 Nos ( for Jockey pump)(e) All as per (b) above but 20 Amp SPN MCB 230 Volts 10 KA - 2 Nos ( for other outgoings) (f) Automatic star delta starter confirming to IS-139474 suitable for main pumping set motor capcity, overload relay range 70-105 Amps including auto timer, single phase preventer etc complete -01 Nos. (g) All as per (f) above but suitable for Jockey pump motor capacity and overload relay range 15-22 Amps -01 No(h) Analog type Voltmeter 0-500 volt range 3 phase AC with selector switch - 1 Nos. .
62(j) Analog Ammeter 0-200 Amps range 3 phase AC with selector switches and CT coils of ratio 200/5 - 01 Set. (k) Analog Ammeter 0-200 Amps range 3 phase AC with selector switches and CT coils of ratio 200/5 - 01 Set. (l) Analog Ammeter 0-60 Amps range 3 phase AC with selector switches and CT coils of ratio 60/5 - 01 Set. (m) Indicator lamp with Integral circuit (240 Volts) and cluster LED and bakelite fuse (Red, Yellow and Blue) - 05 Nos set of 3.
63Supply and Fix single/double sided LED signage single and double phase exit signage universal, body letter colour option Red/Green of min 10 cm x 30 cm size with 5/7 watt LED complete all as specified and directed.
64Supply, installation, testing 7 commissioning of sprinkler flexible pipe (UL Listed) of stainless steel conplete with 15 NPT on reducer thresd with maximum working pressure of 175 PSI test pressure of 875 PSI(Burst) with branch line (Inlet) 25 mm NPT male thread to sprinkler head (Outlet) 15 mm NPT female thread with reducer, nipple, 2 side brackets, centre bracket, stockbar od sizes 0.70 mtr length complete all as specified and as directed.
65Supply and fixing brass primium pack brass flot valve with flexible rod and nitrile rubber seat screwd 25 mm complete all as specified and directed
66COOLING APPLIANCES Supply and fix refrigerator, electric driven (single phase), capacity more than 165 Litres upto to 195 Litres.BEE 5 star rated complete all as specified and directed
67Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed
68DEMOLITION/DISMANTLING/TAKING DOWN Taking down carefully Tube light fitting of any capacity complete complete all as specified and directed
69Taking down carefully Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed
70Taking down carefully switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as specified and directed
71Taking down carefully ceiling rose complete all as specified and directed
72Taking down carefully DB Of any capacity complete all as specified and directed
73Taking down carefully sub main wiring of any capacity complete all as specified and directed
74Taking down carefully lamp holder complete all as specified and directed
75Taking down carefully MCBs of any capacity complete all as specified and directed
76Taking down carefully Earthing set complete all as specified and directed
77DG SET Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 200 KVA/ nearest higher size available KVA, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Jorhat and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 with following:(i) The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design.(A). Alternator :- Standard design alternator rated at 200 KVA/ nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.i) Insualation class - 'H'ii) Temparature rise Class - 'H'iii) Excitation : Self Excitediv) Regulation performance: The voltage is kept constant with + 1%.v) Frequency regulation + 1%
78(B) Diesel Engine: - Adquate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Water pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade.Turbo charger typeExhaust manifoldSilencer : Residential type
79v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.Fuel filtersFuel hosesvi) Lub oil System :- Lubricating oil filterLubricating oil pumpvii) Air Intake System :- Air intake ManifoldAir cleaner dry typeviii) Governer mechanical typeix) Starting System :- Electric Self starter with and including battary charging alternator 24 Volts DC.
80v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.Fuel filtersFuel hosesvi) Lub oil System :- Lubricating oil filterLubricating oil pumpvii) Air Intake System :- Air intake ManifoldAir cleaner dry typeviii) Governer mechanical typeix) Starting System :- Electric Self starter with and including battary charging alternator 24 Volts DC.
81x) Batteries :- Batteries of maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified.Start and stop push buttonIgnition key / SwitchRadiator with blower fan & first fill of coolant oilCorrosion inhibitor coolantDirect fuel injection system through governer mechanical typexi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine.xiii) Coupling arrngement : - Flexible couplingxiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer.xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xvii) Battery Charger shall be provided as per manufacturer guidelines
82C) Civil Works :-All civil works including PCC plat form and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer.Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer. D) Acoustic Enclosure:- Manufactured by OEM suitable for 200 KVA DG Set.(i) Tested by NABL approved lab as per CPCB(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating set battery should be inside the enclosure.(iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 12 hrs continuous operation. If required contract may arrange outside fuel storage capacity to achieve this(v) Construction Details/specification are as follows : -a) Outer body :- CRCA Sheet of 1.6mm thick. b) Doors :- CRCA sheet of 1.6 mm thickc) Sound Insulation :- rock wool of required thickness(minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel levelvi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by CFL/FTL Lamp fittings.ix) The noise level should be 75 dB at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
83Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system to achieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation.(iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr detailed by accepting officer, all testing arrangements/ equipments shall be made available by the contractor for tests.(iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test.(v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates. vi) Design / drawing of the AMF panel suitable for outdoor application with IP 65 and CRCA sheet 3.15mm thick to be provided & DG SET showing the dimensions is to be obtained from DG SET/ panel board manufacturer / supplier & is to be got approved from Engr-in-charge/GE before placing final order to the manufacturer. vii) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc can be done of both SEB mains & DG mains.viii)The quoted rate shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test.
84E) Control Panel :- Control panel shall be made out of CRCA sheet 14 gauge powder coated dust and vermin proof totally enclosed and consisit the following:(a) Microprocessor based generator set monitoring and control system consists of 16 Charactor 2 line LCD disply and to monitor operator interface, fault history, alternator data, Engine data, provision for service adjustement and caliberation of DG control functions, Engine controls,engine protective functions, alternative protective functions etc.(b). Instrument fuses and control wiring.(c). Indication lamps for Set running and load on.(d). Aluminium bus bar copper bus bar TPN for 400 Amps for RYB & 200 Amps for neutral complete for in and out terminalsl wiring with PVC insulated single core copper conductor multistranded wire of 1100 volts grade of suitable capacity including CTs etc, AMF PANEL SPECIFICATIONS : AS PER MANUFACTURER SPECIFICATIONS
85S & F 40 mm bore galvanized steel tubes, Heavy grade including fittings etc. compete all as specified and directed.
86AIR CONDITIONING Supply, installation, testing and commissioning of modulating VRF indoor/ outdoor units (Cooling), with multi scrol inverter compressors ,it should come with special pre-coated fins, panel, corrosion resistant & hydrophilic treatment coated concienser, electrical & microprocessor panel, isolating valves, factory gas charged for proper functioning of the units, having capacities 28 HP (14HPX2 working and 14HPx1 standby).The same system is design in 43 degree celcius & non stop working upto 56 degree celcius ,includind all type of electrical panel/distribution board for supply and connection of VRF system for proper functioning. All false ceiling work including cutting, repairing, painting, with framework ,pipes , cbles etc , Trap Door for Ductable & Concealed AC and necessary foundation of ODU as per OEM reccommondation included in scope of work. Capacity as Iisted below. Outdoor unit system:- (i) 14 HP Top discharge system- 03 Nos Indoor unit system :- Nos of VRF ducted indoor units of different size and capacity as per site requirement on different room with remote based on detail vetted drawing by any Govt Institution submitted by contractor before execution the work
87NOTE:- The above work include:- (i) Supply, installation, testing and commissioning of Refnet joint {Y ioint} of various sizes for interconnection of lndoor units with the existing piping as required. (ii) Supply, installation, testing and commissioning of Refnet joint (Y Joint) of various sizes for interconnection of Outdoor units with the existing piping as required\\" (iii) Instailation, testing & Commissoning of VRF System of 14 HP Top discharge system and VRF ducted units of capacity 8TR, 5TR and 2 TR. (iv) Supply, installation, lesting, commissioning of required sizes (as per OEM) of hard drawn copper refrigerant piping inciuding necessary joints and accessories. brazing, insulation wrth Class- O nitrile tubuiar rubber sleeves sections of 19-13mm thickness for suction line and liquid line , suitable adjsutable ring type hanger supports etc complete as required. (v) Supplying and laying of suitable sizes FR LSH PVC insulaied copoer ccnductor unarmoured cable for controll/communication wiring on surface/recess pvc conduit including cutting the wall where ever required and making good the same etc complete as required. (Betweenlndoor to Out door Units). (vi) Supply,filling, Testing & Commissioning charges for topping-up of refrigerant gas for VRF AC Unit System etc complete as required. (vii) Suppiying, laying, fixing, tesiing cf Rigid UPVC Pipes25/32 mm dia. pipes of 6kg/sqcm, duly insulated with 6mm Thick nirtile rubber- pipe seclion, complete with all necessary fitting such as elbows, tess,reducers. serviceable 'P'traps. etc and supports such as clamps etc complete as per reouired. (viii) Supply & Commissioning 24G/22G GI sheet for ducting ,insulation of GI duct ,powder coated Al 5A Grill with Dampel etc all as required and directed.
88Note:- Schedule of credit (Sch 'A' Part- XVII) amount of Rs 4,11,400.00 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57966583
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22.98 Crore
LAST DATE 14-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Construction Of New Building For Psychiatric Ward By Demolition Of Existing Temporary Building At Af Station Jorhat
Basic Detail
Tender No 88655/JOR/E8
Bidding Type Tender
Location
City Jorhat
State Assam
Key Dates
Publish Date 09 Oct 2026
Submission Date 14 Nov 2026
Open Date 16 Nov 2026
Finance
Tender Value 22.98 Crore
Tender Fee 3000
EMD 14.74 Lakhs
Exemption Available
Document List
BOQ_889417.xls
f3f5000d-46f4-4891-821b-31b7f9d174c6.html
PrePricedShedules.pdf
TD.rar
Tender.pdf
TENDERDRAWINGS.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Nov 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_889417.xls

html

f3f5000d-46f4-4891-821b-31b7f9d174c6.html

pdf

PrePricedShedules.pdf

rar

TD.rar

pdf

Tender.pdf

rar

TENDERDRAWINGS.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender