Tender For Addn/Altn To Certain Rooms In Cr & Ss And Special Repair Of Fire Damaged Items Of Tacte Hq Bldg At Af Stn Gwalior
Tender Value
44.40 Lakhs
Estimated cost
Bid Submission
31 Oct 2026
16 days left
EMD
88800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn/Altn To Certain Rooms In Cr & Ss And Special Repair Of Fire Damaged Items Of Tacte Hq Bldg At Af Stn Gwalior
BOQ
| Sl. No. | Item Description |
| 1 | S&F in repair solid PVC wall lining (Panelling) consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing all as specified and directed by Engr-in-Charge.Note: Colour design and pattern shall be approved by Engineer in charge. |
| 2 | S&F 5 mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed by Engr-in-Charge. |
| 3 | S&F 4mm thick HPSC pre-prime non asbestos fibre cement designer building board (E-classic ) decorative finish including E-grid suspended false ceiling grid system 600x600mm with main runner 33x24x0.6mm, cross tee 25x24x0.6mm and wall angle 19x22x0.4mm ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fasteners to RCC Roof or from purlin with butterfly clips hold down clips etc from soffit at approx 1.20mtr centre to centre including dismantling of old one complete all as specified and directed. |
| 4 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) n.exc 1.5 Sqm each complete all as specified and directed. |
| 5 | Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed. |
| 6 | S&F Powder coated aluminium frame for door, window, ventilators and partitions with extruded built up standard tubular sections with necessary jointing aluminium cleats using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge. |
| 7 | S&F powder coated aluminium door shutters, aluminium section weight 0.55 Kgs/m including necessary joining cleats, glazing clips, rubber neoprene packing, handle 02 Nos in each door, hinges, anodised aluminium snap beading, screws (Thickness of powder coating not less than 50 micron) etc complete all as specified and directed |
| 8 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty including necessary cutting to floor and concrete work complete all as specified and directed. |
| 9 | S&F in repairs 100 mm Brass Mortice lock, 4 Levers, vertical type suitable for aluminium doors complete all as specified and directed. |
| 10 | S&F UPVC sound proof door frame with shutter with double toughned glass glazing 65mm/C65PS3/Z-SASH,DG INS, TGH (5T+12+5T) with cylinder of one side key, one side thumb turn and locking system including necessary builders hardware etc, junction of wall and frame sealed with silicon sealent complete all as specified and as directed. |
| 11 | S&F Powder coated aluminium sliding windows shutters with extruded built up standard tubular sections (using aluminium sec not less than 1.5mm thick), fixing to frame including 4mm thick tinted glass with rubber neoprene gasket, 02 Nos sliding rollers at bottom, necessary locking arrangement to each shutter using C.P./ stainless steel screws, all as specified and directed by Engr-in-Charge. |
| 12 | S&F Aluminium powder coated grills size exc. 6 to 7 mm thick and aperture n.exc. 80mm incl colour matching to the existing Door/ window fixing with aluminium channel 1mm thick with steel screw complete all as specified and directed. |
| 13 | S&F 4mm thick aluminium composite panel of any colour fixed to door with necessary rubber gasket and aluminium snap beadings tint match with existing complete all as specified and directed by Eng-in-Charge. |
| 14 | S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 15 | S&F Solar control film 25 micron reflective type sicked to glass panes as per instructions of manufacturers including scraping and cleaning of old film complete all as specified and directed. |
| 16 | S&F 4mm thick Sheet glass, ordinary quality in squares and complete all as specified and directed. |
| 17 | Demolition of cement concrete (unreinforced) including floor tiles, screed bed at ground floors and pavings n. exc 15 cm thick below or above ground level complete all as specified and directed. |
| 18 | M & L for 25mm thick cement concrete 1:2:4 (12.5mm graded aggregate) type B-0. as in sub base complete all as specified and directed. |
| 19 | M&L for coloured vitrified ceramic tiles 8 to 9 mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM (1:6) all as specified and directed. |
| 20 | all as per item herein before but as in skirting/dado including 10mm thick cement plaster 1:4 as backing coat complete all as specified and directed. |
| 21 | M&L for 10 mm thick double charged vitrified coloured ceramic tiles (square/ rectangular) area of each tile exc. 0.42 Sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 22 | all as per item herein before but as in skirting/dado including 10mm thick cement plaster 1:4 as backing coat complete all as specified and directed. |
| 23 | M&L for 15mm thick rendering on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement in cement plaster (1:6) complete all as specified and directed. |
| 24 | M&L for 5mm thick rendering on ceiling other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement in cement plaster (1:3) complete all as specified and directed. |
| 25 | M&L for Preparation of newly plaster surface of wall and applying two coat of distemper oil emulsion white or tinted over a coat of primer incl plaster of Paris 1 mm thick over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 26 | Complete removal of existing treatment on wall surfaces (any number of layers) by scrapping with steel scrappers (manually/mechanically) and applying two coats of distemper oil emulsion with Roller over one coat of primer over a coat of wall putty including preparation of surfaces complete all as specified and directed. |
| 27 | M&L for Complete removal of old distemper on ceilling surface and applying two coat of distemper oil emulsion white or tinted over and incl plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 28 | M&L for Preparation of newly plaster surface of ceiling suraces and applying two coat of distemper oil emulsion with Roller and 1mm thck putty to make the surface even & smooth complete all as specified and directed. |
| 29 | Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out cleaning and stacking bricks, removing surplus serviceable bricks, and rubbish not exc. 50m & complete all as specified and directed. |
| 30 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil all as specified and directed. |
| 31 | Demolition of Roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and directed. |
| 32 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil all as specified and directed. |
| 33 | all as per item here in before but depth exceeding 1.5 m and not exceeding 3 m all as specified and directed. |
| 34 | M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 35 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar work vertical or to batter all as specified and directed. |
| 36 | Use and waste of formwork to sides of pillars, posts, struts, piers, column and stanchions for rough finished surfaces of concrete square, Circular rectangular on plan or polygonal all as specified and directed. |
| 37 | Use and waste of formwork to sides of sides and soffits of floor or roof beams, beam hauncheing, girders, bressmmers, lintels cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc all as specified and directed. |
| 38 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) all as specified and directed. |
| 39 | M&L for Reinforced cement concrete M25 (Design Mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete all as specified and directed. |
| 40 | M&L for Reinforced cement concrete M25 (Design Mix) using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed. |
| 41 | M&L for Reinforced cement concrete M25 (Design Mix) using 20 mm graded stone aggregate as Slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck salb and in shelves and the like all as specified and directed. |
| 42 | M&L for Reinforced cement concrete M25 (Design Mix) using 20 mm graded stone aggregate as beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed. |
| 43 | M&L for Mild steel TMT reinforcement Bars of 10 mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clip all as specified and directed. |
| 44 | M&L for Mild steel TMT reinforcement bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securing with clip all as specified and directed. |
| 45 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed. |
| 46 | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed.. |
| 47 | M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 48 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete as specified. |
| 49 | M<reating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete as specified. |
| 50 | M & L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete as specified. |
| 51 | M&L for Hard core of gauge n.exc 63 mm , with broken stone or boulders , deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface all as specified and as directed. |
| 52 | M&L for 100 mm thick PCC 1:4:8 type D-2, (using 40 mm graded aggregate) as sub base finished even and smooth with using extra cement complete as specified and directed. complete all as specified and directed. |
| 53 | M&L for 75m mm thick plain cement concrete type C-1, 1:3:6 mix using 20mm graded stone aggregate as in plinth protection, pavings, path etc. surface finished even and smooth without using extra cement complete as specified and directed. |
| 54 | M&L for Rendering 10 mm thick in cement plaster 1:6 on fair faces of concrete surfaces finished even and smooth without using extra cement all as specified and directed. |
| 55 | M&L for preparation of new plastered surfaces on walls and applying two coats of distemper oil emulsion with roller over one coat of primer white or tinted as approved complete all as specified and directed. |
| 56 | M & L 15 mm thick rendering in CM 1:4 on fair faces of bricks/concrete, finished even & smooth without using extra cement and mixed with water proofing compound (liquid type) @ 200 ml per 50 Kg of cement complete all as specified and directed by Engineer-in-Charge. (Note : WPC (liquid type) shall be measured and paid separately as supply only) |
| 57 | M&L for Preparation of newly plastered surface and applying two coat of weather coat exterior emulsion white or tinted by the use of rollers over a coat of primer as approved complete all as specified and directed. |
| 58 | Supply only Liquid water proofing compound. |
| 59 | M & L preperation of ceiling surface and applying three coats of white wash in ceiling surface complete all as specified and directed. |
| 60 | M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions (Note:Water proofing compound shall be measured and paid seprerately under respective item of \\"BoQ\\") |
| 61 | M&L for hybrid (acrylic+ polyurethene) based waterproofing flexible liquid applied membrane single component, three coat system reinforced with fibre mesh having crack bridging upto 2mm and elongation upto 200% and dry film thickness(DFT) 1000 microns with Heat reflective system for all types of exposed roof slabs (new and old) terraces (sloped and flat) complete all as specified and directed. |
| 62 | M & L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed and all as specified and directed. |
| 63 | S&F for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staples(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or csat aluminium alloy complete all as directed and specified |
| 64 | S&F 100 mm Brass Mortice lock, 4 Levers, vertical type suitable for aluminium doors complete all as directed and specified |
| 65 | S&F 4mm thick HPSC pre-prime non asbestos fibre cement designer building board (E-classic ) decorative finish including E-grid suspended false ceiling grid system 600x600mm with main runner 33x24x0.6mm, cross tee 25x24x0.6mm and wall angle 19x22x0.4mm ceiling suspended with 4mm dia GI wire hanger fixed with steel dash fasteners to RCC Roof or from purlin with butterfly clips hold down clips etc from soffit at approx 1.20mtr centre to centre complete all as specified and directed. |
| 66 | M&L for prepration of old wall surfaces by filling the cracks/ depressions with wall putty/POP to make the surface even and smooth and applying a coat of distemper oil emulsion with roller white or tinted complete all as specified and directed. |
| 67 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed. |
| 68 | Demolition of stone slabs and interlocking tiles of any description or thickness in floors, aprons etc laid in any type of mortor complete all as specified and directed. |
| 69 | M&L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 20mm th screed bed in CM 1:6 complete all as specified and directed. |
| 70 | M&L for complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers and and applying a coat with pop putty to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats distemper oil emulsion over a coat of primer with roller complete all as specified and directed. |
| 71 | S & F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified complete all as specified complete all as specified and directed |
| 72 | Supply & Fixing 5mm thick sheet glass as in hinged doors, partition, automatic doors and similar work including cutting shapes and drilling holes required as specified. |
| 73 | Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, by unscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed surfaces of walls floors etc all as directed. |
| 74 | M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, terminal boxes closed recessed type. PVC Plastic board all as required as specified and directed for the following :- |
| 75 | (a) One light/ Fan point controlled by one way switch. |
| 76 | (b ) One 5 Amps switch socket combination on independent board. complete all as specified and directed. |
| 77 | (c) One 5 Amps socket on same board with other switches. complete all as specified and directed. |
| 78 | All as per item herein above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point as directed. |
| 79 | S&F Modular switch 1 way 6A, 1 module single pole 230 V ISI marked omplete all as specified and directed. |
| 80 | S&F Modular type switch socket out let 6 amps and 16 amps 230 Volts multipurpose, ISI marked complete all as specified and directed. |
| 81 | M&L in replacement for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit. |
| 82 | M&L in replacement for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 16 Sqmm FRLS of voltage rating 1100 Volts drawn in and including recessed PVC conduit medium grade 32mm dia with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 16 Sqmm as earth continuity conductor complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and 32mm dia PVC conduit shall be measured as one unit. |
| 83 | Supply, fixing, connecting & testing in repair of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 8 way DBs vertical type for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating incl taking down old one complete all as specified and directed. |
| 84 | Supply, fixing, connecting & testing in repair of sheet metal enclosures double door (IP-42 Protection), single pole and neutral, 8 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps rating incl taking down old one complete all as specified and directed. |
| 85 | S&F in repair MCCB, 4 pole, 160 Amps current rating and ultimate breaking capacity ics=Icu =100% 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. |
| 86 | S&F in repair MCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity ics=Icu =100% 16 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. |
| 87 | S&F in repair MCB isolator double pole 63 Amps 'C' curve having current rating 10KA,240 Volt to be fixed in distribution board, complete all as specified and directed. |
| 88 | S&F in repair MCB isolator Triple pole 40 Amps 'C' curve having current rating 10KA,240 Volt to be fixed in distribution board, complete all as specified and directed. |
| 89 | S&F in repair, Single Pole 6 to 32 Amps 'C' curve having current rating 10KA,240 Volt to be fixed in distribution board, complete all as specified and directed. |
| 90 | Supply& Fixing in replacement of LED Batten fittings 1x20 Watt complete with round block etc, incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engineer-in-Charge. |
| 91 | Supplying and fixing in replacement of decorative surface mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Grid ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable, including all accessories and fixing arrangements for fixing the 2x2 LED light fitting to false ceiling complete all as specified and directed. |
| 92 | S&F ceiling rose surface backelet ISI marked , 2 to 3 terminal all as specified and directed. |
| 93 | Supply and fixing ceiling fans complete with blades, down rods, electronicregulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC)complete all as specified and directed. |
| 94 | S&F fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| 95 | S&F fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents