Tender For Upgradation Of Work Station In Svy Room And Other Revenue Works At Bldg No P-163 Under Age B/R Ii Chandimandir
Tender Overview
Project Description
Tender for Upgradation Of Work Station In Svy Room And Other Revenue Works At Bldg No P-163 Under Age B/R Ii Chandimandir
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Oct-2026 | Revised Page | Other | 29-Oct-2026 |
| 2 | 17-Oct-2026 | Revised BoQ | BOQ | 29-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed |
| 2 | Vitrified coloured light shade tiles, 8-10mm thick (square/rectangular) polished area of each tiles exc 0.36 sqm but n.exc 0.42 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 3 | Solid 14mm WPC Louvers wall paneling (size 192x2900mmx14mm) fixed to walls with necessary clip screw/adhesive complete all as directed by Engineer-in-Charge. (Make :- Mega Star) complete all as specified and directed. |
| 4 | 1.5mm thick PVC sheet fillet/angle/beading of width 35mm for wall paneling inclusive fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed. |
| 5 | False ceiling with powder coated exposed Gl grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exc 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmx600mm. Grid of modular size 600mm x600 mm shall be supported by 4mm dia Gl wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200 Kg/Cum) of size 595mmx 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per IS 1530 part 3 & BS-476 Part-4, 5, 6,7 & 8 complete all as per manufacturer's instruction, complete all as specified and directed. |
| 6 | Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed. |
| 7 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square Meter with shutters, without taking off shutters from the frame, complete all as specified and directed. |
| 8 | Factory made UPVC coloured sliding window three track made of extruded profile with wall thickness of 2.30mm, Window profile with hollow section with multi chamber frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5 x 28mm), Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corner, including railing of holes for fixing hardware and drainage etc, making arrangement for fixing of hardware, EPDM gasket 1.2, 0.2mm thick galvanized steel frame (30mm x 18mm) 02 Nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to wall with 8mm x 100mm long fasteners. Hardware touch lock with zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, 8mm thick tinted float and required accessories complete all as specified and directed. (Note: The unit rate quoted by the contractor include the cost of glass, wire cloth and includes all other connected accessories) |
| 9 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 10 | 4.80mm thick Glass pane ordinary quality frost in one side, fixed to aluminum frame work in panels exc 0.5 sqm in each pane, complete all as specified & directed. |
| 11 | 3mm thick aluminium composite panel sheet (ACP) of colour as approved by Engr In Charge, complete all as specified and directed. |
| 12 | 200mm long aluminum anodized barrel tower bolts of extruded section and fixed, complete all as specified. |
| 13 | Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 , complete all as specified. |
| 14 | Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed. |
| 15 | Mortice lock, verticle type, mild steel, 4 levers, size 100mm, brass body, complete all as specified and directed |
| 16 | Aluminium (extruded section body) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851mm to 1000mm in width and of weight between 61 to 80 Kg complete, all as specified & directed by Engineer-in-charge. |
| 17 | 10mm thick rendering in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement, including taking down existing plaster complete all as specified & directed. |
| 18 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 19 | providing cement concrete type C-2, 1:3:6 using 40 mm graded stone aggregate, as in foundation, mass concrete etc., complete all as specified and as directed |
| 20 | Virgin polymer surface drain channel of 1 mtr length of external width and height 160mm & 156mm, inner dimension 110 x 110mm with 20mm thick composite grating cover with suitable capacity of 1.5 MT wheel load and accessories like male / female end caps with push fit locking system and the end cap with minimum 110 outlet and laid as per required slope complete all as specified and directed. Make : Supreme or as approved by GE |
| 21 | Taking down copper/aluminium point wiring (light, fan, socket point 5/15 amps) complete, including fittings such as switches, ceiling rose, light fitting, sockets bulb holder, ceiling rose etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 22 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 23 | All as per serial item 22 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 24 | All as per serial item 22 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 25 | All as per serial item 22 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 26 | Switch modular type (ISI marked), single pole, one way 6 Amps one way, one module (ISI marked), complete all as specified & directed. |
| 27 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed. |
| 28 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 29 | Socket shutters outlet 2 in 1, 3/5 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 30 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 31 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
| 32 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 33 | Electric Bell, ding dong, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
| 34 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 35 | LED lamp 9 watts, B-22 type complete all as specified . |
| 36 | Disconnection and taking down old unserviceable MCB DB, junction box, panels of any size complete with al MCCB’s, MCB’s etc and removing from site , complete all as specified and directed. |
| 37 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 38 | MCB, SPN, 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 39 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 40 | LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. |
| 41 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through and including PVC conduit 25mm size(minimum size), cutting chases in walls for PVC conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 42 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through and including PVC conduit 25mm size(minimum size), cutting chases in walls for PVC conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. NOTE FOR SERIAL ITEM NO 41 & 42: (i) Two runs of cable, one run of earth wire shall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 43 | LED panel recess mounted 2'x2' - 36 watts cool day ceiling light, (6000K) fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complete all as specified and directed. |
| 44 | Sheet metal enclosre SPN with a two pin and earth plug and socket complete including with 20 Amp MCB 'C' single pole 240 volt complete all as specified and directed. |
| 45 | wall mounted fan of sweep 450 mm, operating voltage at 220-240 V with all mounting accessories complete all as specified and directed. |
| 46 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose to fan complete all as specified and directed. |
| 47 | Supply , installation & testing of voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5.0 KVA complete all as specified and directed. Please Enable Macros to View BoQ information |
| 48 | Supply , installation & testing of voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5.0 KVA complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender