Tender For Providing Partition Wall, Rolling Blinds And Other Modifications Works In New Chemistry Building At Iit Roorkee.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Nov 2026
12 days left
EMD
93000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Partition Wall, Rolling Blinds And Other Modifications Works In New Chemistry Building At Iit Roorkee.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 2 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregae 20 mm nominal size derived from natural sources). |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 6 | Suspended floors, roofs, landings, balconies and access platform |
| 7 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 9 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 10 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 12 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor Vlevel |
| 15 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 16 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. Complete at all levels. |
| 17 | Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble |
| 18 | Area of slab over 0.50 Sqm |
| 19 | Granite stone slab of colour black, Cherry/Ruby red |
| 20 | Area of slab over 0.50 Sqm |
| 21 | Granite stone slab of all colour and texture except black, Cherry/Ruby red |
| 22 | Area of slab over 0.50 Sqm |
| 23 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 24 | Marble work |
| 25 | Granite work |
| 26 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 27 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 28 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, includingpointing in white cement mixed with pigment of matching shade complete |
| 29 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 30 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 31 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 32 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): |
| 33 | Rectangular or square |
| 34 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 35 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete |
| 36 | Fixed to steel windows by welding |
| 37 | Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378 |
| 38 | 300x16 mm |
| 39 | 250x16 mm |
| 40 | Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 41 | 200x10 mm |
| 42 | 150x10 mm |
| 43 | 100x10 mm |
| 44 | Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) |
| 45 | 125 mm |
| 46 | 100 mm |
| 47 | 75 mm |
| 48 | Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 49 | 300x16 mm |
| 50 | 250x16 mm |
| 51 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 52 | 300x10 mm |
| 53 | 250x10 mm |
| 54 | 200x10 mm |
| 55 | 150x10 mm |
| 56 | 100x10 mm |
| 57 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete |
| 58 | 125 mm |
| 59 | 100 mm |
| 60 | Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 61 | Twin rubber stopper |
| 62 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 63 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. |
| 64 | 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) |
| 65 | 75 mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 66 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge |
| 67 | Providing & Fixing decorative high pressure laminated sheet of plain I wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 68 | 1.0 mm thick |
| 69 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1. 70 mm for Series R 1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a GovernmentEngineering Institute, to be provided by the manufacturer for(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii) Sites with structure height more than 20m for all wind speeds |
| 70 | Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 71 | Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m). |
| 72 | Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height above 1.8m). |
| 73 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body |
| 74 | Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 75 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multipoint locking system. (Height above 1.8m) |
| 76 | Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body. |
| 77 | Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). |
| 78 | Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above)' x (85 mm & above). (Height above 2.5 metre). |
| 79 | Two track four panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, adjustable nylon rollers with SS 304 body |
| 80 | Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). |
| 81 | Using R4 series with frame (64 mm & above) x (45 mm & above) & sash (44 mm & above) x (85 mm & above). (Height above 2.5 metre). |
| 82 | Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body. |
| 83 | Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). |
| 84 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (85 mm & above). (Height above 2.5 metre). |
| 85 | Three track three panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body |
| 86 | Using R3 series with frame (98 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre |
| 87 | Using R4 series with frame (115 mm & above) x (45 mm & above) & sash (44 mm & above) x (85 mm & above). (Height above 2.5 metre). |
| 88 | Fixed window/ ventilator without mullion/ transom. |
| 89 | Using R2 series with frame (39 mm & above) x (39 mm & above). (Height upto 1.2 metre) |
| 90 | Using R3 series with frame (55 mm & above) x (45 mm & above). (Height upto 2.5 metre) |
| 91 | Using R4 series with frame (64 mm & above) x (50 mm & above). (Height above 2.5 metre) |
| 92 | Fixed window/ ventilator with mullion / transom |
| 93 | Using R 1 series with frame (33 mm & above ) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre) |
| 94 | Using R2 series with frame (39 mm & above ) x (39 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre) |
| 95 | Using R3 series with frame (55 mm & above ) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre |
| 96 | Using R4 series with frame (64 mm & above ) x (50 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 2.5 metre) |
| 97 | Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. |
| 98 | Using R1 series with frame (33 mm & above) x (35 mm & above) & sash /mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre). |
| 99 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash /mullion (39 mm & above) x (60 mm & above). (Height upto 1.2metre) |
| 100 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash /mullion (55 mm & above) x (65 mm & above). (Height above 1.2 metre) |
| 101 | Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system zinc alloy (zamak) powder coated handles. |
| 102 | Using R3 series with frame (55 mm & above ) x (45 mm & above) & sash (55 mm & above) x (65 mm & above). (Height upto 1.8 metre |
| 103 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above). (Height above 1.8 metre) |
| 104 | Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles |
| 105 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). |
| 106 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre). |
| 107 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre) |
| 108 | Casement window double panels with French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles |
| 109 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & French (False) mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). |
| 110 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 1.8 metre). |
| 111 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 1.8 metre). |
| 112 | Casement cum fixed panel window having one single casement panel & one fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles |
| 113 | Using R2 series with frame (39 mm & above ) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above)x (60 mm & above). (Height upto 1.2 metre; Each openable shutter upto 0.8m width) |
| 114 | Using R3 series with frame (55 mm & above ) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre; Each openable shutter upto 0.8m width) |
| 115 | Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre; Each openable shutter upto 0.8m width) |
| 116 | Casement cum fixed panel window having single casement panel at both ends & middle fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. |
| 117 | Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre; Each openable shutter upto 0.8m width) |
| 118 | Using R3 series with frame (55 mm & above) x (45 mm & above) & sash (55 mm & above) x (65 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 1.8 metre; Each openable shutter upto 0.8m width) |
| 119 | Using R4 series with frame (64 mm & above ) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre; Each openable shutter upto 0.8m width) |
| 120 | Casement Window with Double Rebate Frame with one Side Hung Glazed Panel and one Side Hung wire mesh Panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel |
| 121 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre) |
| 122 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel and two Side Hung wire mesh Pane and Fixed Mullion with S.S. 304 friction hinges as per siez and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles on both glazed and fly screen panel. |
| 123 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm & above) x (65 mm & above) & fly screen sash (30 mm & above) x (55 mm & above) & mullion (55 mm & above) x (65 mm & above) & metal grill (if required to be paid separately). (Height upto 1.8 metre |
| 124 | Casement Window with Double Rebate Frame with two Side Hung Glazed Panel on outside and two Side Hung wire mesh Panel on inside and French (False) Mullion with S.S. 304 friction hinges as per size and weight of sash, multipoint locking system, zinc alloy (zamak) powder coated handles with shoot bolt on both glazed and fly screen panel |
| 125 | Using R3 series with frame (110 mm & above) x (45 mm & above) & glazed sash (55 mm &above) x (65 mm & above) & fly screen sash(30 mm & above) x (55 mm & above) & French(False) mullion (55 mm & above) x (60 mm& above) & metal grill (if required to be paid separately). (Height upto 1.8 metre). |
| 126 | Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. |
| 127 | Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre |
| 128 | Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above). (Height above 2.5 metre). |
| 129 | Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides. |
| 130 | Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 2.5 metre). |
| 131 | Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 2.5 metre). |
| 132 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 133 | 125 mm |
| 134 | 100mm |
| 135 | 75 mm |
| 136 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 137 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 138 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 139 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 140 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 141 | Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 142 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 143 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with |
| 144 | 4.0 mm thick glass panes |
| 145 | 5.5 mm thick glass panes |
| 146 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 147 | 40 mm thick with 20 mm nominal size stone aggregate |
| 148 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. |
| 149 | 40 mm wide and 4 mm thick |
| 150 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/Sqm including pointing the joints with white cement and matching pigment etc., complete |
| 151 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete |
| 152 | Size of Tile 600x600 mm |
| 153 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily |
| 154 | Double charge vitrified tile polished finish of size |
| 155 | Size of Tile 600 x 600 mm |
| 156 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ Sqm. |
| 157 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge |
| 158 | Size of Tile 600x600 mm |
| 159 | Providing gala 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design |
| 160 | In 75x75 mm deep chase |
| 161 | Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per Sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 162 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross \\"T\\" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x 24 X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making openingfor services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main 'T'. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. |
| 163 | 12 mm cement plaster of mix : |
| 164 | 1:4 (1 cement: 4 coarse sand) |
| 165 | 1:6 (1 cement: 6 coarse sand) |
| 166 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 167 | 1:4 (1 cement: 4 coarse sand) |
| 168 | 1:6 (1 cement: 6 coarse sand) |
| 169 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge |
| 170 | For door/ window/ clerestory window |
| 171 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 172 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 173 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 174 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 175 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge |
| 176 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 177 | In cement mortar |
| 178 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 179 | From brick work in cement mortar |
| 180 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 181 | Of area 3 sq. metres and below |
| 182 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 183 | For thickness of tiles 10 mm to 25 mm |
| 184 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 185 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 186 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-charge. |
| 187 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 188 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 189 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge |
| 190 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge |
| 191 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 192 | Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost) |
| 193 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge |
| 194 | 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 195 | 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern |
| 196 | Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. |
| 197 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required |
| 198 | Size 600x450x200 mm |
| 199 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 200 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 201 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc |
| 202 | 20 mm nominal dia .Pipes. |
| 203 | 25 mm nominal dia .Pipes. |
| 204 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanicallywherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 205 | For fixed portion |
| 206 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 207 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 208 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 209 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 210 | Powder coated aluminium (minimum thickness of powder coating 50 micron |
| 211 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge |
| 212 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 213 | Pre-laminated particle board with decorative lamination on both sides |
| 214 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 215 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/Sqm) |
| 216 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/Sqm) |
| 217 | With float glass panes of 8 mm thickness (weight not less than 20 kg/Sqm) |
| 218 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in- charge. |
| 219 | With stainless steel cover plate minimum 1.25 mm thickness |
| 220 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 221 | Upto 5mm depth and 5 mm width |
| 222 | Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete |
| 223 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 224 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 225 | Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6&7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the exiting frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge |
| 226 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge |
| 227 | With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 |
| 228 | P/F stainless steel first quality curtain rod with all fitting and fixture i/c bracket and all other necessary accessories complete as per direction of engineer in charge. or equivalent of approved make as per directions of E.I.C. |
| 229 | S/F of 100 mm wide vertical blinds NEHA/VISTA/CLASSIC or any other equivalent approved brand with prior approval of EIC, complete in all respect. or equivalent of approved make as per directions of E.I.C. |
| 230 | Providing & fixing Blackout Fabric roller blinds which should be made up of 100% polyster with acrylic coating resistant to cracking and fraying it should have 100% black out rate. The fabric should be min. 0.50 mm (+-5%) and having weight 350 g/sqmt (+-5%), light fasteness >6., can be installed on face ceiling mount on frame in recuses. The fixing bracket are made by steel with powder coating to give grater finish, bracket shall be accomedating over head or side mounting with clutch assembly on either end of the blinds. The roller tube shall be extruded by non rusting aluminium alloy with 1.25 mm thickness, with anodized for long life available in 32-40 mm dia for small and big blinds respectively, aluminium bottom bar with powder coating 55 microns or 10 microns anodized operating chain : 10 Plastic / steel ball chain or as per manufacture specifications adopted clutch pitch for smooth lifting and lowering of blinds. The blinds can be stopped in desire position with help of stop lock used for raising or lowering action of the shades. The fixing arrangement as per approved make and specifications all complete as per direction of EIC. Approval of the samples shall be taken before supplying and fixing.Make - IKEA, DECKO, D’Decor or Equivalent |
| 231 | Providing laying and jointing 160 mm dia UPVC pipe of Ist quality complete in all respect as per direction of EIC or equivalent of approved make as per directions of E.I.C. |
| 232 | Providing laying and jointing 110 mm dia UPVC pipe of Ist quality complete in all respect as as per direction of EIC or equivalent of approved make as per directions of E.I.C. |
| 233 | Providing laying and jointing 75 mm dia UPVC pipe of Ist quality complete in all respect as as per direction of EIC or equivalent of approved make as per directions of E.I.C. |
| 234 | Providing and fixing table mounted sink cock with swinging pipe spout (Table Mounted Model) with ESSCO make model no. SQT 523S or equivalent approved make as per directions of EIC |
| 235 | Providing and fixing wall mounted sink cock with swinging pipe spout with ESSCO make model no. SQT-522S or equivalent approved make etc. complete as per directions of EIC |
| 236 | Providing and fixing short body bib cock with ESSCO make model no. SQT-511KN or equivalent approved make as per directions of EIC |
| 237 | Providing and fixing long body bib cock with Wall Flange & Aerator ESSCO make model no. SQT-512KN or equivalent approved as per instruction of EIC |
| 238 | Providing and fixing health faucet with 8 mm dia, 1 meter long flexible Tube & Wall hook. Jaquar make model no. ALD 573 or equivalent approved make as per directions of EIC |
| 239 | Providing and fixing CP brass angular stop cock with valve flange Jaquar Make Model No. CON-059KN or equivalent approved make as per directions of EIC |
| 240 | Providing and fixing 75 mm dia upvc nahani trap with material and labour etc complete as per directions of EIC or equivalent of approved make as per directions of E.I.C. |
| 241 | Providing and fixing 100 mm dia CP floor jali (Heavy Duty) as per direction of EIC or equivalent of approved make as per directions of E.I.C. |
| 242 | Brick work with old bricks (supplied free of cost at our stores) in superstructure above plinth level up to floor V level in cement mortar 1:6 (1 cement : 6 coarse sand) or equivalent of approved make as per directions of E.I.C. |
| 243 | Half brick masonry with old bricks (supplied free of cost at our central stores) in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) masaonry with old bricks (1:4 cm) etc. complete in all respects as per directions of EIC or equivalent of approved make as per directions of E.I.C. |
| 244 | Supplying and fixing SS pull handle H type (pair) size of 450 mm Dorset make model no. SH 18 P SS or equivalent of approved make as per direction of EIC |
| 245 | Supplying and fixing SS pull handle H type (pair) size of 300 mm Dorset make model no. SH 12 P SS or equivalent of approved make as per direction of EIC |
| 246 | Supplying and fixing SS pull handle H type (pair) size of 600 mm dorset make model no. SH 24 P SS or equivalent of approved make as per direction of EIC |
| 247 | Extra difference cost for providing and fixing glass door fitting combo set with lock patch. Top bottom patch fittings of dorset model no. CS 100 WL or equivalent approved make having brand logo embossed on the body/plate with a double spring mechanism and door weight upto 100 kg for doors, including cost of cutting floor, embedding in floors as required and making good the same matching to the existing floor finishing and cover plate with brass pivot and single piece MS sheet (With SS Cover plate minimum 1.25 mm thickness) outer box with slide plate etc. complete as per the direction of EIC. or equivalent of approved make as per directions of E.I.C. |
| 248 | Extra difference cost for providing and fixing glass door fitting combo set with lock patch. Top bottom patch fittings of dorset model no. CS 70 WL or equivalent approved make having brand logo embossed on the body/plate with a double spring mechanism and door weight upto 70 kg for doors, including cost of cutting floor , embedding in floors as required and making good the same matching to the existing floor finishing and cover plate with brass pivot and single piece MS sheet (With SS cover plate minimum 1.25 mm thickness) outer box with slide plate etc. complete as per the direction of EIC. or equivalent of approved make as per directions of E.I.C. |
| 249 | Supplying & fixing of 10 mm thick pvc wall penaling with prior approval of EIC, complete in all respect. or equivalent of approved make as per directions of E.I.C. |
| 250 | Providing, mixing and applying 12 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. or equivalent of approved make as per directions of E.I.C. |
| 251 | Providing, mixing and applying 15 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. or equivalent of approved make as per directions of E.I.C. |
| 252 | Providing and fixing 1mm thick lamination on door of green Lam make or equivalent of approved colour and shade as per direction of the EIC. or equivalent of approved make as per directions of E.I.C. |
| 253 | Providing and fixing 12 mm thick toughened glass in fixed portion including godrej glass clip fittings or equivalent as per approved make necessary holes etc. for fixing required fitting, all complete as per direction of EIC or equivalent of approved make as per directions of E.I.C. |
| 254 | Providing and fixing 35 mm thick ISI mark ply flush door shutters non-decorative type of century ply make or equivalent approved make complete in all respects as per directions of EIC or equivalent of approved make as per directions of E.I.C. |
| 255 | Providing and fixing 32 mm thick ISI mark flush door shutters non-decorative type of centuryply make or equivalent approved make complete in all respects as per directions of EIC or equivalent of approved make as per directions of E.I.C. |
| 256 | Providing and fixing S.S. Sliding door bolt of 200x16 mm with nuts and screw etc. complete as per direction of EIC or equivalent of approved make as per directions of E.I.C. |
| 257 | Providing and fixing mortice handle lock with of doorset make model no. Cetto or equivalent of approved make as per directions of E.I.C. |
| 258 | Providing and fixing hydraulic door closer Godrej make or equivalent approved make with necessary accessories and screws etc. complete in all respects as per directions of EIC or equivalent of approved make as per directions of E.I.C. |
| 259 | Dismantling and re-fixing of old aluminium door, window, and partition work in all respect Engineer Incharge. or equivalent of approved make as per directions of E.I.C. |
| 260 | Providing and fixing 5 mm thick toughened glass etc complete as per directions of E.I.C. or equivalent of approved make as per directions of E.I.C. |
| 261 | Providing & Fixing false ceiling grid on the existing tile of size 595 x 595 within 50 meters lead as per direction of Engineer in Charge. or equivalent of approved make as per directions of E.I.C. |
| 262 | Providing & fixing Dorset floor spring modle no. CS100 GM or equivalent of approved make as per directions of E.I.C. |
| 263 | Providing & Fixing of 18 mm WPC Wood polymer composite Solid paint white colour board or equivalent of approved make as per directions of E.I.C. |
| 264 | Fixing glazed/ceramic/Vitrified floor tiles with cement based high polymer modified quick set tile adhesive (Water based) conforming to IS 15477, in average 6mm thickness (600 x 600mm) or equivalent of approved make as per directions of E.I.C. |
| 265 | Providing & Fixing beveled edge mirror of supeior glass (of approved quality and required size) complete with 6 mm thick cement bonded particle board ground fixed to spacers with C.P. brass / SS secrew and washers etc all complete as per direction of Engineer In Charge. or equivalent of approved make as per directions of E.I.C. |
| 266 | For Calculation purpose Only |
| 267 | Sub Total (A) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysNov 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents