Tender for Proposed Construction Of 100 Seated Girls Hostel Building (G+1 Storied) Including Boundary Wall (200 Mtr Length) In Vidyajyoti Schools Attached To Amtali H.S School Under Dukli Block, West Tripura District Under Central Financial Assistance Under North East Special Infrastcture Development Scheme (Nesids) From Modoner / Sh:- Building Portion Including Internal Water Supply, Sanitary , Installation , Swage, Drainage Works , Boundary Wall, Retaiining Wall / Providing Internal Electrification Including Outdoor Illumination Thereof.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2 x 1.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2 x 2.5 sq. mm PVC insulated Copper conductor cable (FR) on modular concealed switch board with cover plate earthing the 3rd pin etc. as required. |
| 7 | Wiring for 2 way controlling light point with 3x1.5 sq. mm PVC insulated copper conductor cable (FR) in PVC conduit (medium gauge) recessed in slab/ wall complete with 6/10 amps modular type 2 way switch, cover plate, GI box including necessary connection etc. as required. |
| 8 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 9 | 2 X 1.5 sq mm |
| 10 | 2 X 2.5 sq mm |
| 11 | 2 X 4 sq mm |
| 12 | 4 X 6 sq mm |
| 13 | 4 X 10 sq mm |
| 14 | 4 X 16 sq mm |
| 15 | 4 X 25 sq mm |
| 16 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 17 | 1 X 1.5 sq mm |
| 18 | 1 X 2.5 sq mm |
| 19 | 1 X 4 sq mm |
| 20 | 1 X 6 sq mm |
| 21 | 1 X 10 sq mm |
| 22 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 23 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 24 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 25 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 26 | 4 step fan regulator (1M):- |
| 27 | Buzzer call bell (1M):- |
| 28 | Blank plate (1M):- |
| 29 | 20/25 amps single phase motor starter switch (2M):- |
| 30 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 31 | 15 amps power top:- |
| 32 | 32 amps DP kit kat switch:- |
| 33 | Supplying & fixing of 900 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) |
| 34 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W). |
| 35 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 36 | Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:- |
| 37 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 38 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 39 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 40 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 41 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 42 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 43 | Surface mounted box type batten suitable for double 18/20 watt integrated LED tube lamp (without lamp):- |
| 44 | Surface mounted round/Square shaped 18/20 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 45 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 46 | 90 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 47 | 40 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):- |
| 48 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 49 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 50 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 51 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 52 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 53 | Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 54 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 55 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 56 | 2 way SPN MCB DB (single door):- |
| 57 | 4 way SPN MCB DB (double door):- |
| 58 | 4 way horizontal TPN MCB DB (double door):- |
| 59 | 6 way horizontal TPN MCB DB (double door):- |
| 60 | 8 way horizontal TPN MCB DB (double door):- |
| 61 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 62 | 6 to 32 amps SP MCB:- |
| 63 | 6 to 32 amps DP MCB:- |
| 64 | 40/50/63 amps FP MCB:- |
| 65 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 66 | 100 amps kitkat porcelain fuse unit with base(rewireable):- |
| 67 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 68 | 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 69 | 63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330 mmx280mmx100mm):- |
| 70 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 71 | Supplying and laying of following sizes XLPE insulated PVC sheathed Aluminium conductor Un-armoured cable including necessary connection etc as required. |
| 72 | 3 core 4 Sq mm |
| 73 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 74 | 1.5 sqmm - 4 sqmm Cable:- |
| 75 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 76 | 40 mm dia |
| 77 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 78 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 79 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 80 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 81 | Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:- |
| 82 | Enclosure suitable for MCCB upto 100 amps:- |
| 83 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. |
| 84 | 19/20 mm dia |
| 85 | 25 mm dia |
| 86 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 87 | 1-2 module GI switch board:- |
| 88 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 89 | 1-2 module :- |
| 90 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required:- |
| 91 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 40 KA (3P+N) :- |
| 92 | Supplying of 25 cm long ‘L’ hook made with 40mm x 6mm MS flat and fixing with necessary fasten nuts including finishing, painting etc as required. |
| 93 | Supplying & fixing of 40 mm dia G.I pipe (medium gauge) cross bar for fixing of ceiling fan/luminaries including painting & necessary accessories etc as required. |
| 94 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 95 | 2.5 sq mm |
| 96 | 4 sq mm |
| 97 | 6 sq mm |
| 98 | 10 sq mm |
| 99 | 16 sq mm |
| 100 | 25 sq mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender