Tender For Supply And Fixing Of Split Type Airconditioner Units To Thethaei Ward Doctors Room In Government Medical College Hospital At Virudhunagar In Virudhunagar District
Tender Value
1.02 Lakhs
Estimated cost
Bid Submission
26 Oct 2026
6 days left
EMD
1100
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Virudhunagar → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply And Fixing Of Split Type Airconditioner Units To Thethaei Ward Doctors Room In Government Medical College Hospital At Virudhunagar In Virudhunagar District
BOQ
| Sl. No. | Item Description |
| 1 | Renewal by Supply and errection of 1.5 Ton 3STAR rated Split type Airconditioners ) GI sheet (ABS, HIPS plastic Fitted with rotary compressors operating refrigerant R-22/non CFC suitable (for floor mounting and ceiling mounting) confiriming to IS 1391 (part2) 92 (AMDT .1)(except power consumption Norms) suitable,operation on 230V,50HZ single phase AC supply. 1.Mounting/ Fitting Indoor and Outdoor units at the respective locations.. 2. Laying refrigerant pipeline of required length not exceeding 4 metres distance and connecting both units after drilling hole/holes in the wall, if required. Thickness of copper tubing shall not be less than 0.7mm 3. Insulating the suction pipe with expanded polyethelene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit. 5. Leakage testing the entire system. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 sqmm PVC insulated copper wire between indoor and outdoor units upto 4 metres length and upto switch within 3 metres of location of indoor unit. (Carrier/Voltas/Blue star make only) |
| 2 | Supply and fixing of 4KVA Electronic Automatic voltage Stabilizer V-Guard make model SMART - TECH VND 500 15A / 150 - 285V / Equivalent output range 150 -285 V with high and low voltage cut of and 3 minutes time delay. |
| 3 | Renewal by supply and laying of 5/8\\" and 3/8\\" copper refrigerant pipes of 0.8mm thick with 2.5 sqmm 3 core copper chord complete between indoor and outdoor units. ( Extra beyond 3 mts / AC unit. (For split AC unit) |
| 4 | Renewal by supply and fixing of MS stand for fixing Spilt Airconditioner Outdoor Unit. |
| 5 | Gst @ 18 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender