Power Government Departments Closing in 13 days TDR #57964417

Tender For Augmentation Of Grid Station Katarsamna (Kishtwar) Of 01 No. 20 Mva Transformer With 50Mva Transformer And Replacement Of Old Outlived 20Mva Transformer At Gss Nhpc With Transformer To Be Spared After Augmentation And Other Associated Work

Issued by Government Departments · Kishtwar, Jammu and Kashmir
Tender Value
8.54 Crore
Estimated cost
Bid Submission
30 Oct 2026
13 days left
EMD
17.08 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kishtwar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Augmentation Of Grid Station Katarsamna (Kishtwar) Of 01 No. 20 Mva Transformer With 50Mva Transformer And Replacement Of Old Outlived 20Mva Transformer At Gss Nhpc With Transformer To Be Spared After Augmentation And Other Associated Works In Kishtwar (Katarsamna) Grid Station And Nhpc Gss Kishtwar

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Oct-2026 Corrigendum-I Technical Bid 30-Oct-2026

BOQ

Name of Work:- Augmentation of grid station Katarsamna (Kishtwar) of 01 no. 20 MVA Transformer with 50MVA Transformer and replacement of old outlived 20MVA Transformer at GSS NHPC with Transformer to be spared after augmentation and other associated works in Kishtwar (Katarsamna) grid station and NHPC GSS Kishtwar
Sl. No. Item Description
1Design, Engineering. Manufacture,workshop testing, supply including packing, forwarding, insurance,transportation,delivery at site , Erection, testing commissioning as per approved design/drawings and in conformity to the relevant and applicable BIS/IEC and CEA standards
250 MVA, 132/33 kV Three Phase Power Transformers with OLTC, SCADA Compatible RTCC, NIFPES , HV and LV connectors and other required accessories and fittings with online DGA monitoring Kit, online dehydration kit and maintenance free automatic breathers as per technical specifications with all mandatory spares as per SBD. 50 MVA, 132/33 kV Three Phase Power Transformers with OLTC, SCADA Compatible RTCC, NIFPES , HV and LV connectors and other required accessories and fittings including all mentioned manadatory spares including HV & LV Bushing with metal parts & gaskets (1 no each),Gasket sets complete,Buchholz relay (1 No.), Cooler fan with motor (2 nos) ,Silica Gel Breather, Inlet and Outlet valves & Gasket,Oil sampling bottles (Air tight stainless steel with capacity 01 (one liter and clocks fitted at both ends)**
3SITC of CONDUCTOR AND HARDWARE FITTINGS
4500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
5Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
6Single Suspension Fittings For Single 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type suspension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 120 KN.
7T Clamps 0.5 / 0.5 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
8pad clamps/CT clamp 0.5 made of Aluminium alloy and shall comply in all respects with IS:5561-1970 (latest edition) for isolator and breaker
9Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia.Creepage total 430 mm and 260 mm protected.
10SITC of POWER AND CONTROLCABLES
113.5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,galvanised steel wire/strip armoured stranded copper conductor control cable complete
128 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,galvanised steel wire/strip armoured stranded copper conductor control cable complete
1316 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,galvanised steel wire/strip armoured stranded copper conductor control cable complete
1419 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS,galvanised steel wire/strip armoured stranded copper conductor control cable complete
15SITC of 132KV Equipments
16Single phase,50c/S 132kv Voltage Transformers (132/√3) KV/ (110/√3) V ,One min power freq withstand 275 KV rms with clamps
17132KV Control and Relay Panel for Line/Feeder simplex/duplex as per requirement, completely wired including Substation automation /SCADA/supporting IEDs/numerical relays of make ABB/SIEMENS/GE MICOM/ALSTOM/SCHNEIDER with IEC 61850 compatibility, including Distance Recorder and under Frequency Relay. (Ist Line Protection) Distance Protection Directional O/C & E/F Protection (Back Up Protection), Local Breaker Backup (LBB) Protection
18132KV Control and Relay Panel for transformer bay completely wired includingSubstation automation/SCADA, supporting IEDs/numerical relays inlcuding Distance Recorder of make ABB/SIEMENS/GE/MICOM/ALSTOM/SCHNEIDER withIEC 61850 Compatibility including under frequency relay,differencial protection,directional o/c and e/f protection(on HV &LV side) ,numericale communicable REF protection relay,,over flux protection,local breaker backup protection(integrated in distance protection and backup protection),separate relays for primary and backup protection
19SITC of 33KV Equipments
2033KV Control and Relay Panel for TRANSFORMER BAY SIMPLEX/DUPLEX as per requirement, completely wired including Substation automation/ SCADA/supporting IEDs/numerical relays of make ABB /SIEMENS/GE/MICOM/ALSTOM/SCHNEIDER with IEC 61850 compatibility
21Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 31.5KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA Acc. 0.2s with clamps
22Replacement of existing ACSR Zebra by ACSR Moose conductor including fittings , insulators discs, clamps etc. in 33kv transformer bay as per site requirements
23Dismantling of old 132kv and 33kv equipments viz: CR Panels, CT sets , Pt sets including dragging, carriage to site store as per site requirements
24Dismantling of 20mva transformer, cables & associated equipments, hardware items/accesories including dragging, loading, unloading, carriage, transportation of 20mva power transformer & accessories from GSS katarsamna kishtwar to GSS Nhpc kishtwar
25Filling of oil, filtration and dehydration of 20 MVA transformer at Gss Nhpc kishtwar
26Replacement of gaskets earthing strips etc. of 20MVA transformer(IMP Make) at Gss Nhpc kishtwar
27Erection,Testing (BDV , tan Delta, ratio, magnetic balance etc.) and commissioning of 20MVA transformer (IMP Make) at Gss Nhpc kishtwar
28Dismantling of old 20mva transformer, cables, earthing transformer and other accessories including dragging, loading, carriage, transportation of 20mva power transformer from GSS Nhpc kishtwar to Divisional store Udhampur & unloading , stacking
29Civil Works
30Earth Mat (40mm dia steel bars) as per approved design, Galavanised Iron (75x10 / 50x 6 / 25x3 )mm risers for Equipment and Structural Earthing
31Rail Track
32Laying of Transformer foundations for Three phase 50 MVA Transformer(as per Drawing)
33Construction of Oil sump & Tank for three phase 50 MVA Transformer
34Construction of Fire Protection Wall
35Dismantling of old transformer (20MVA) foundation at Gss Katrsamna kishtwar
36Minor Repair of 20MVA transformer foundation in concrete(M15) at GSS Nhpc kishtwar
37Providing of spanner set-2 No. , Binocular -1No. Of specification to be got approved from AEE Concerned, clamp on meter-1no., Rechargeable LED torch ( for long distance with good brightness) -2No.( all items to be provided at GSS kishtwar) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57964417
AUTHORITY Government Departments
TENDER VALUE 8.54 Crore
LAST DATE 30-10-2026
Authority
Authority Name Power Development Department
Work Description Tender for Augmentation Of Grid Station Katarsamna (Kishtwar) Of 01 No. 20 Mva Transformer With 50Mva Transformer And Replacement Of Old Outlived 20Mva Transformer At Gss Nhpc With Transformer To Be Spared After Augmentation And Other Associated Works In Kishtwar (Katarsamna) Grid Station And Nhpc Gss Kishtwar
Basic Detail
Tender No TLMD-III/Udh/14 of 2026-27 Dated 09-10-2026
Bidding Type Tender
Location
City Kishtwar
State Jammu and Kashmir
Key Dates
Publish Date 14 Oct 2026
Submission Date 30 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 8.54 Crore
Tender Fee 5000
EMD 17.08 Lakhs
Exemption Available
Document List
0db199ea-db93-4d70-bb0e-901925b30f6f.html
BOQ_1108676.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 13 days
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

0db199ea-db93-4d70-bb0e-901925b30f6f.html

xls

BOQ_1108676.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender