Housing Urban and Rular Development Private Organizations Closing in 23 days TDR #57962091

Tender For Construction Of Vendor Market Cum Multi Level Car Parking At Plot No Cp-2/A Under Nabadiganta Industrial Township Authority.

Issued by Private Organizations · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Nov 2026
23 days left
EMD
2.88 Crore
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Vendor Market Cum Multi Level Car Parking At Plot No Cp-2/A Under Nabadiganta Industrial Township Authority.

BOQ

Name of Work:- Construction of Vendor Market cum Multi Level Car Parking at Plot No CP-2/A under Nabadiganta Industrial Township Authority.
Sl. No. Item Description
1TOTAL
2This BOQ is inclusive of all the taxes including Labour Welfare Cess and GST.
3Providing RCC cast in situ bored piles in position as per specifications in all kinds of soil except rock of any hardness including cost of boring by any method but using drilling mud (bentonite) to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremmie method in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of hire charges of all implements (i.e. pile rigs and thin mobilisation) necessary for boring, placing of concrete, welding of reinforcement cage complete but excluding the cost of reinforcement and labour for bending, binding etc. Work to be executed as per IS : 2911 (Part I / Sec 2).Cement concrete should have an ultimate crushing strength of not less than 250 kg. / cm2 on 15 cube at 28 days and its cement content not less than 400 kg. / cum of concrete.Using tripod, winches and other accessories including shifting of all machinery from one bore location to another and removal of excavated earth with all lifts and lead upto 150 mtr.500 mm. Dia, Length upto 30.0 m. from F.G.L.
4The bidder shall quote individual item rate inclusive of all the taxes including Labour Welfare Cess and GST.
5Extra for Providing 10 mm × 10 mm Grooves at 125 mm c/c in M25 Concrete Flooring of Car Ramps Providing and forming 10 mm wide × 10 mm deep grooves at 125 mm centre-to-centre spacing in the M25 grade concrete flooring of car ramps, 4.0 m wide, at all levels, for providing an anti-skid/tyre-gripping surface, including setting out, marking, groove formation/cutting, finishing, cleaning and all necessary labour, tools, machinery and incidental works, complete as per approved drawings and directions of the Engineer-in-Charge.
6Providing, Supplying & fixing Glass Canopy with SS (GR. 304) Structure of 100 x 100 x 3 mm thick SHS with base plate & stiffeners as per the approved shop drawings, and 50 mm dia SS bush fixed with main structure, base plate, fixed with 12 x 125 mm RCC Chemical anchor fastener from Hilti / Fischer , glass shall be fixed with SS spider fitting from DORMA make. The glass shall be 13.52 mm thick laminated glass (6 mm thick clear toughened Glass + 1.52 PVB + 6 mm thick clear toughened glass The complete glass canopy system including laminated glass, supporting structure, fittings and connections shall be designed and executed in accordance with relevant provisions of IS 2553 (Part 1):2018, IS 16231 (Part 1):2019, IS 16231 (Part 3):2019 and IS 16231 (Part 4):2019. The supporting steel structure shall be designed in accordance with IS 800:2007 and the canopy shall be designed for applicable dead, imposed and wind loads as per IS 875 (Part 1), IS 875 (Part 2) and IS 875 (Part 3). The RCC substrate and anchorage zone shall comply with IS 456:2000. All proprietary chemical anchors shall be installed strictly in accordance with the manufacturer's approved technical data, design calculations and installation procedure. Final glass thickness, panel dimensions, fixing locations, spider fittings, anchor size and spacing shall be as per structural design calculations and shop drawings prepared by fabricator and approved by Architect.”
7Providing & fixing automatic sliding door with 12 mm thick clear toughened heat-soak tested safety glass, complying with IS 2553 (Part 1):2018, complete with DORMA ES 120 Easy 4.5 m operative package, including automatic door operator, drive unit, sensors, controllers, rollers, guides, locks, brackets, glass fittings, safety devices and all necessary fixtures and accessories, complete as per manufacturer's specifications and approved shop drawings. The complete automatic door system shall comply with applicable safety requirements for power-operated pedestrian doors and shall be tested, commissioned and handed over in proper working condition.
8Supplying, fitting & fixing surface mounted overhead door closer for 2-hour fire-rated doors, EN-4 size, suitable for door leaf width up to 950/1100 mm and maximum door leaf weight of 60/80 kg, CE certified, marked and conforming to EN 1154:2003, of approved quality and reputed make, suitable for installation on the specified fire-rated door set and tested/approved as part of the fire-rated door assembly in accordance with IS 3614:2021, including all necessary brackets, fixing accessories, fasteners, adjustment and installation complete as per manufacturer's recommendations, approved shop drawings and direction of Engineer-in-Charge.
9Supplying, fitting & fixing flat FRP Jali Panels of minimum thickness 6 mm, as per architectural design, with approved paint finish, including all necessary framework, brackets, fasteners, sealants and accessories, complete as per approved shop drawings and manufacturer’s specifications. FRP cladding and fixing shall be suitable for applicable wind loads as per IS 875 (Part 3):2015.
10Providing, fixing & painting 50 mm thick GRC jali of approved design, including MS framework, necessary fasteners, scaffolding and accessories, complete as per approved drawings. Framework shall be structurally designed and approved by the Architect, considering applicable wind loads as per IS 875 (Part 3):2015 and IS 800:2007.
11Providing, supplying, manufacturing and fixing 4.0 mm thick extruded aluminium metal Jali/screen of approved architectural design, pattern and module, manufactured from architectural grade Aluminium Alloy 6063-T5/T6,and frame size 66x33x3.6 and sub- frame 50x25x3.2 and 60-80 micron powder coating for external wall of car parking area, including all necessary perimeter framing, intermediate supporting members, stiffeners, brackets, cleats, connection plates, SS 304 fasteners, approved anchorages, cutting, drilling, fabrication, assembly, alignment and fixing at all heights, including powder coating/PVDF finish of approved colour, complete with all necessary accessories, scaffolding/access equipment and incidental works, as per approved architectural and structural drawings and direction of Engineer-in-Charge. The complete system shall be designed for applicable wind pressure and suction in accordance with IS 875 (Part 3):2015.
12MECHANICAL ANCHOR
13Supplying, drilling/cleaning hole and fixing of ETA approved, Torque Controlled, ETA approval for Seismic C1 & C2, Fire approved, FM Approved Expansion Anchor pre assembled with galvanized bolt & nut, stainless steel ingenious expansion sleeve of sizes ranging from M8 to M24. Anchor shall be fixed at right embedment depth as per embedment mark and activated using Torque Module to ensure adequate torque as per manufacture’s torque tolerance published in ETA and same shall be documented and submitted to Project Manager at the time of inspection. Design of Anchor should be done as per ETAG 001 Annex C and TR045 using Anchor Design Software as per actual load data and site conditions as provided by structural consultant and the report to be submitted to the project manager and design engineer for approval. Scanning before drilling to be done with Rebar Scanning tool to avoid rebar hits.
1410 mm core diameter
1512 mm core diameter
1616 mm core diameter
1720 mm core diameter
1825 mm core diameter
19Supplying, fitting and fixing of approved-quality speed breaker, including all necessary modules, reflective markings, anchor fasteners, fixing accessories and installation on existing road/pavement surface, complete in all respects as per approved drawings, manufacturer’s specifications and directions of the Engineer-in-Charge.
20Providing, supplying, fitting and fixing 600 mm diameter safety convex traffic mirror for multi-level car parking ramps, blind corners, turning points and vehicular intersections, of approved make and reputed quality, comprising a minimum 600 mm diameter UV-stabilized convex acrylic/polycarbonate reflective surface, providing wide-angle visibility and suitable for indoor/outdoor parking applications. The mirror shall be impact-resistant, weather-resistant, moisture-resistant and suitable for continuous exposure to parking environment. The mirror shall be mounted in a robust UV-stabilized ABS/HDPE/polycarbonate protective frame with heavy-duty adjustable/swivel mounting bracket and suitable SS 304/galvanized fasteners, anchor bolts, nuts and washers. The mirror shall be securely anchored to the RCC wall/column at the location and mounting height approved by the Engineer-in-Charge and accurately oriented to provide maximum visibility at blind curves, ramp bends and junctions. The rate shall include mirror, protective frame, mounting bracket, anchor fasteners, drilling, fixing, alignment, adjustment, labour, tools, tackles, access equipment and all incidental works, complete in all respects as per approved drawings, manufacturer's recommendations and direction of Engineer-in-Charge.**
21L-shaped MS column barrier/guard
22Supplying, fabricating and fixing L-shaped MS column barrier/guard as shown, comprising MS plates/sections of s 50X50 mm in size and 2.5m in length and size, formed to suit the column profile, with welded joints, stiffeners, base plates and suitable anchor fasteners for secure fixing to the floor/column. Barrier shall be finished with approved reflective yellow paint and black diagonal warning stripes, including surface preparation, primer, anti-corrosion treatment and finishing coats. Complete with all materials, fabrication, welding, fixing, fasteners, painting, labour and accessories, as per approved drawings and directions of the Engineer-in-Charge.
23Providing & fixing automatic sliding door with 12 mm thick clear toughened heat-soak tested safety glass, complying with IS 2553 (Part 1):2018, complete with DORMA ES 120 Easy 4.5 m operative package, including automatic door operator, drive unit, sensors, controllers, rollers, guides, locks, brackets, glass fittings, safety devices and all necessary fixtures and accessories, complete as per manufacturer's specifications and approved shop drawings. The complete automatic door system shall comply with applicable safety requirements for power-operated pedestrian doors and shall be tested, commissioned and handed over in proper working condition. (size: 6.500 x 1.500 M)(for 5500 openting) width x 1500 height sliding Gate and 1.200 x 1.500M.) height wicket Gate)
24Supplying, fitting and fixing automatic boom barrier of approved make and capacity, complete with boom arm, drive motor, control panel, limit switches, safety sensors, manual release, LED warning lights, mounting base, loop detector/vehicle detection system, remote/access-control interface, wiring and all necessary accessories. Complete installation, testing and commissioning as per manufacturer’s specifications, approved drawings and directions of the Engineer-in-Charge. (2-5.5 Meter Heavy duty )
25Supply and installation of indoor LED parking information (available & full) display board . Communication port RS 485)
26\\"Logo of Government of West Bengal\\" (14.0Ft dia)
27Supplying and fixing ,develop signage concept and design and create with all required technical drawing with materials of NDITA Facad Logo Signage basic structure made of MS Hollow Section 50x50mm x 2.5mm hidden structure fixing on the wall with chemical fastner, logo dimension is 16ft dia , Side part of Logo should be maintain 2 layer projected with partition made of Aluminium Profile ( 1.2mm thk ) , raise with 100 mm Cutting and folding by computer numeric control cutting and grooving machine and Typography made of electro cut vinyl Film 3M/ LG -guided CNC base plotter and Surface material 3mm laser cut acrylic , the text part and as per drawing , backlit Portion should be Illuminated with GOQ LED module with Power Supply , proper alignment should be as per approved drawing and instruction of Archetect and back part of logo should be made (ACM ) 3mm are flat panels consisting of two thin coil - coated (paint thick ness SDP - 24 - 28) aluminium sheeets bonded to a core First grde LDPE. Min. Good shear strength (N/mm square ASTM D732) and frame which should be coated epoxy base anti rust paint (base panel) . Base ms plate as per drawing and cutting by laser machine.
28\\"ASHOK STAMBH \\" BACK THROUGH LIGHT
29Supplying, fabricating and fixing ‘ASHOK STHAMBH’ signage, including concept, design and all required technical/shop drawings. Signage shall be fabricated from 2 mm thick MS plate, fibre-laser cut as per approved drawings, with outer profile raised by 40 mm using 0.8 mm thick CRC sheet. Surface shall be finished with approved-colour Duco paint. Rear side shall be provided with warm-colour LED modules for halo illumination, complete with suitable power supply, wiring and accessories. Signage shall be fixed to the wall maintaining a 1.5 inch clear gap, including all necessary brackets, anchors, supports, finishing, alignment and complete installation as per approved drawings and directions of the Architect/Engineer-in-Charge.
30\\"NDITA PARKING \\" Self Standing Backlit Letter
31Supplying, fabricating, fixing and installing NDITA façade logo signage, including concept, design and all required technical/shop drawings. Concealed structure shall be 50 × 50 × 2.5 mm MS hollow section, fixed to the wall with approved chemical fasteners, for 16 ft dia logo, designed for applicable wind loads as per IS 875 (Part 3):2015 and fabricated using structural steel conforming to IS 2062:2011 and IS 800:2007. Logo sides shall be maintained in two projected layers with 1.2 mm thick aluminium profile partitions, raised by 100 mm, CNC cut, grooved and folded. Typography shall be in 3M/LG electro-cut vinyl film with 3 mm laser-cut acrylic face, as per approved drawings. Backlit portions shall be illuminated with GOQ LED modules and suitable power supply, including wiring and accessories, conforming to IS 732:2019 and IS 1646:2015. Rear/base panel shall comprise 3 mm ACM, with coil-coated aluminium skins bonded to first-grade LDPE core, supported on MS framing. MS base plates shall be laser-cut and all MS components shall receive epoxy-based anti-rust coating. Chemical fasteners and fixing shall be suitable for the substrate and installed as per manufacturer’s recommendations. Complete with all hardware, accessories, finishing, alignment, testing and commissioning as per approved drawings and directions of the Architect/Engineer-in-Charge.
32Supplying, fitting and fixing LED Display (Ready Cabinet Module P5) of size 75 ft × 55 ft, The size may vary marginally as per site conditions. comprising P5 LED modules/cabinets, SMPS/RC, receiving and sending cards/controllers, power and data cables, connectors, control system and all necessary accessories. The display shall be properly aligned, supported and securely fixed on the approved structural framework, including all required mounting hardware, electrical connections, testing, programming, commissioning and complete installation as per manufacturer’s recommendations, approved shop drawings and directions of the Architect/Engineer-in-Charge. 3 no.s 3 D-animation film to be provided each of 30 sec duration, created as per directions of the Architect/Owner.
33Parking
34Celling hanging signage single side (1500mmx250mm)
35Supplying, fabricating and fixing ceiling-hung signage of size as per site condition, comprising 3 mm thick black ACP panel, CNC-router cut as per approved drawing, with text in yellow vinyl, CNC plotter cut and neatly pasted on the panel. Signage shall be suspended/fixed from the ceiling using suitable approved brackets, rods, anchors, fasteners and necessary fixtures, including alignment, finishing and complete installation as per approved drawings and directions of the Architect/Engineer-in-Charge.
36i) size : 1500x250 mm
37ii) Size : 1200x 250mm
38iii ) Size : 1000x300 mm
39Wall Signage In Front of Ramp (Ref A)
40Supplying, fabricating and fixing wall-mounted signage of size 1200 × 2000 mm, comprising 3 mm thick black ACP panel, CNC-router cut as per approved drawings, with text in yellow vinyl, CNC-plotter cut and neatly pasted on the panel. Signage shall be securely fixed to the wall using suitable approved brackets, anchors, fasteners and necessary fixtures, including alignment, finishing and complete installation as per approved drawings and directions of the Architect/Engineer-in-Charge.
41SANITARY FIXTURES OF CP & CHINA WARE WITH ANCEALARIES
42Providing and fixing s Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook.
43Providing and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.600 mm long
44Providing and fixing Chromium plated double coat Hook .
45Providing and fixing liquid soap container. a) Chromium plated.
46Providing and fixing CP Pillar Cock with 200 mm extended Lever Handle.
47Providing and fixing CP towel Ring complete with brackets fixed to wooden cleats with C.P. brass screws.
48Providing and fixing CP brass Two way bib tap.
49DOMESTIC WATER SUPPLY
50Providing and Installation C.I. body bolted bonnet inside screw non-rising SS Stem Gate Valve (Sluice Valve) PN 1.0 as per IS:14846, lubricated asbestos gland packing and flange as per IS:1538.
5165mm nominal bore
5280mm nominal bore
53Providing and fixing gun metal Pressure Reducing station for cold water supply comprising of 2 Nos. of gun metal ball valves on outlet and bye-pass and ball valve with inbuilt strainers and a PRV (Diaphram type) unit with out going pressure gauge with flanged or union connection including safety valve. The complete system is tested to a pressure not less than 15 Kg/Cm2 and suitable to reduce the pressure to 1.5 Kg/Cm2 (Or as desired at site) including flanges/unions, nuts, bolts and washers complete as required for applications.
54a) 50 mm nominal bore
55b) 65 mm nominal bore
56Providing & fixing, Testing & Commissioning gunmetal float valve (heavy duty) of approved superior quality with low or high pressure plastic float for uPVC/CPVC/G.I Pipes, complete in all respects. (Rate including with required fitting for connection in the tank).
57a) 40 mm nominal bore
58Providing & fixing CI 600 mm dia medium grade man hole cover with frame for OHT .
59Providing & fixing 100mm dia G.I Vent Pipe for OHT.
60Providing & fixing Foot Rest for OHT .
61SOIL, WATSE & RAIN WATER PIPE SYSTEM
62Providing & fixing, jointing, testing and commissioning of uPVC SWR pipe confirming to IS : 13592, Type- A cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces (plain or door). Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated. ( Rain water & Drain pipes)
63a) 110 mm O.D
64b) 160 mm O.D
65Providing & fixing, testing and commissioning of uPVC SWR pipe confirming to IS-13592, Type-B cut to required lengths including all necessary fittings and special such as bends, junctions offset, access pieces (plain or door), Tees, bends, reducers, flanges, plugs unions and clamps Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated including chasing, cutting and making good the walls / floor etc. wherever required. (Soil, Waste & Vent Pipes)
66a)110 mm O.D
67Providing & fixing, jointing, testing and commissioning of uPVC pipe schedule 40 (for waste drainage of wash basin and kitchen sink etc.) cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces (plain or door). Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly paint epoxy coated.
68a) 32 mm
69b) 40 mm
70c) 50 mm
71Providing & fixing of Floor Trap of 100x100 mm dia including cutting and making good the wall/floor wherever required.
72Providing & fixing heavy duty 125mm S.S. Floor grating with frame of approved design brand including setting in floor with cement motor to match with floor finish as per architect requirement including cutting and making good floor or wall wherever required.
73Providing & fixing of Floor drain of 100x100 mm dia including cutting and making good the wall/floor wherever required.
74Providing & fixing uPVC cowl complete including cutting and making good the walls and floors wherever required.
75a) 110 mm O.D
76Providing & fixing 3mm thick C.I. grating with frame to the inlet mouth of drainage pipes/floor drains.
77a) 125 mm dia
78b) 175 mm dia
79Excavating trenches of required width for pipes, cables, etc., including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including taking out the excavated soil and then backfilling the soil as required in layers, not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus soil as directed within a lead of 100m.
80All kind of soils (Pipes exceeding 80mm dia but not exceeding 300mm dia).
81Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design.
82PUMPING SYSTEM
83Supplying, installing, testing & commissioning of Horizontal centrifugal non clog water pumps with CI Head & Base, SS304 / Bronze Impeller along with motor, pressure gauge with isolation cock, Mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia) for the pump. The pump shall be suitable for 415±10% volts 3 phase AC supply. (SS304 Impeller)
84Domestic Water Transfer Pumps : -
85Set of two pumps (1 Working + 1 Standby)
86Capacity : 10 cum/hr
87Head : 65 M
88RPM : 2900
89Drainage Sump Pumps
90Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage pumps with Bronze impeller complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricatd from 14 gauge CRCA sheet volt meter ammeter with selector switch, TPMCB, 5 VA CL: CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to BAS, both pumps may run simultaneously at pre determind level. Consisting 02 pumps in a set.
91For Plant room.
92(1 Working + 1 Standby)
93Capacity : : 18 cum/hr
94Head : 15 M
95Terrace Booster Pump
96Supplying, installing, testing & commissioning of Hydro Pneumatic variable speed drive, SS316 Bronze Impeller along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Mechanical seal, suitable vibration elimination pads, neoprine connector of approved design, The pump shall be suitable for 415±10% volts 3 phase AC supply including contol panel with PLC and pressure vesel capacity 20 ltrs as per manufacturer specifications.
97Location : Terrace of Each Block
98(1 Working + 1 Standby)
99Capacity : 2.5 LPS
100Head : 20 M Please Enable Macros to View BoQ information
101Head : 20 M Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57962091
AUTHORITY Private Organizations
TENDER VALUE Ref. Documents
LAST DATE 04-11-2026
Authority
Authority Name Mackintosh Burn Limited
Work Description Tender for Construction Of Vendor Market Cum Multi Level Car Parking At Plot No Cp-2/A Under Nabadiganta Industrial Township Authority.
Basic Detail
Tender No MBL/ NDITA/ NIT 03 OF 2026-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 09 Oct 2026
Submission Date 04 Nov 2026
Open Date 06 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2.88 Crore
Exemption Not Available
Document List
b4223869-99b9-4cee-9bb9-620059268cca.html
BOQ_5180371.xls
GAD.pdf
makelist.pdf
SOQ.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

b4223869-99b9-4cee-9bb9-620059268cca.html

xls

BOQ_5180371.xls

pdf

GAD.pdf

pdf

makelist.pdf

pdf

SOQ.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders