Public Administrative Department Local Bodies Closing in 15 days TDR #57962031

Tender For Construction Of Water Resevoir At Near Kumverpar Of Sansad No.-16/136 Madhabdanga-1 G.P. Under Maynaguri. Activity Id- 110933128/2025-26(Sl. No. 07)

Issued by Local Bodies · Jalpaiguri, West Bengal
Tender Value
3.44 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
15 days left
EMD
6882
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Water Resevoir At Near Kumverpar Of Sansad No.-16/136 Madhabdanga-1 G.P. Under Maynaguri. Activity Id- 110933128/2025-26(Sl. No. 07)

BOQ

Name of Work:- Construction Of Water Resevoir at near Kumverpar of Sansad no.-16/136 Madhabdanga-1 G.P. Under Maynaguri. Activity Id- 110933128/2025-26(Sl. No. 07)
Sl. No. Item Description
1Earthwork in excavation for foundation of structures as per drawing and technical specification including setting out, removing, spreading or stacking of spoils within a lead of 150 m. as directed and including trimming the sides of the trenches, leveling, dressing and ramming the bottom, complete as per direction of the Engineer-in-Charge.In all sorts of soil excluding marshy soil & rocks (soft or hard) by manual means. Depth up to 3 m. : With pumping out water including shoring as required. (a) Depth of excavation not exceeding 1,500 mm.
2Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work. (a) With earth obtained from excavation of foundation.
3Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work. (b) With earth obtained by fresh excavation (including cost of excavation upto 1,800 mm. depth) from land arranged by the Deptt. within a lead of 100 m.
4Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
5(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety In ground floor . (a) 1:3:6 proportion
6Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(ii ) River Bazree
7Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel, II. Other than, SAIL/ TATA/RINL
8Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
9M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereofI) For structural members of specified sections weighing less than 22.5 Kg./m
10Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (c) 10 mm thick plaster
11Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
12Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer, (d) 2000 litre capacity
13Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (i) 50 mm dia. boring etc.
14Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.
15Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (ii) 50 mm dia
16Item No:-12(vi)/Page- 53 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.
17Item No:-17(i)/Page- 54 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supplying, fitting and fixing heavy type bell mouth reducing socket.
18Item No:-27/Page- 56 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
19Item No:-01/Page- 102 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supply of G. I. pipes of TATA make including necessary sockets quality.(f) 50 mm dia. (ii) Medium quality
20Item No:-01/Page- 102 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supply of G. I. pipes of TATA make including necessary sockets quality.(i) 100 mm dia. (i) Medium quality
21Item No:-10(ii)/Page- 53 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supplying, fitting and fixing plug of approved make conforming to I.S. specifications (ii) 50 mm
22Item No:-19(iii) of (A)/Page- 13 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes100 mm
23Item No:-19(iii) of (A)/Page- 13 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes50 mm
24Item No:-19(iii) of (A)/Page- 13 of PWD Sanitary & Plumbing Works with effect from 01.11.2017Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes25 mm
25PV Module Supplying, fixing commissioning and testing solor Photo Voltaic Module 300WP, 40V on existing iton frame structure each 156mm Monocrystallic Silicon solar cells laminated between sheet of Ethynal Vinyl Acetate (EVA) and high transmissivity 3 mm tempered glass. Conforming to IEC 61215(revised) specification or equivalent National Standards.The power output of the module(s) under STC should be a minimum of 300 W. The operating voltage corresponding to the power output mentioned above should be 56V. The open circuit voltage of the PV modules under STC should be atleast 57.0 Volts. The terminal Box IP 65 Protection level on the module should have a provision AC submersible pump set ( designed to use with Solar Power) in the New/Existing bore-well/Tube well of approved brand (KSB/CG/DUKE/SHAKTI/CRI/SUNLIGHT make) having dischargenot less than |1000 Ltrs /hour at 40 Mtrs. head including supply of all necessary materials viz. required dia column pipes etc. as specified of approved quality, labour etc. with all allied works as per direction of site In charge/ Engineer for opening tfor replacing module.
26Pump Controller Unit(PCU) only DC:- Supplying, fixing, commissioning and testing pump controller unit consisting with PCU Switching elements MOSFET Type of Charger PWM with MPPT technology |Input from PV 800V max to 370V DC, 1 to 1.5HP, single Phase with protection Short circuit, Deep ischarge, |Input surge Voltage, over current, Battery reverse Polarity, Solar array reverse polarity Dielectric strength1. 1 KV between input/output and ground with EMI protections removed. Cooling Forced with |temperature sensitive fan operation Ambient |temperature 50 degree Celsius (Max) Operating Humidity 95% maximum Assembly/Mounting as per |normal industrial practice Finish Epoxy Power Costing'|Cable Entry from rear, preferably 200 mm above ground |level all system parameters shall be displayed System parameters LCD display such as battery voltage, output (load) voltage, load current etc (Kriloskar/Sukam/Exide) make
27Suppy and Fixing round 2 core 4sgmm PVC multi core FR wire for array connecting.
28Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long). |13 mm dia x 80 mm long GI bolts, double nuts, double |washers incl. S & F 15 mm dia Gil pipe protection (1 Mts. fong) to be filled with bitumen partly under the ground 20 level and partly above ground level driven to an average |depth of 3.65 Mts. below the ground level as below: By ISI-Medium Gl pipe
29Supply, Installation, tesing & lowering of 1 HP oil fill DC solar submersible pump motor set complete having suitable dischage as per yeld test of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC bar chart (Kriloskar make Pump) and necessary control panel and starter as per manufacturar
30Providing and fixing of lightning conductor finial, made of |25 mm dia 300mm long, copper tube, having single prong at top, with 85 mm dia 3mm thick copper base 2e plate including holes etc. complete as required.
31Connecting the equipment to the earth busbar incl. S&F GI wire of size bellow on wall /floor as required and |making connection to the equipment with bolts, washers, cable lugs etc. as required and nmending good damages No 4 SWG GI wire
32Supply, fitting, fixing of 38mm dia column pipe having 3.04mtr length including supply and fixing one socket at one end (TATA-M make)
33Supply, Installation testing & Commissioning of Iron Filteration unit for clean, clear, and fresh water
34Supply, Installation testing & Commissioning of Automatic water Pump Contoller( ISO9001:2008)
35Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.)
36Add:- GST @ 18%
37Add:- Labour Welfare Cess @ 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57962031
AUTHORITY Local Bodies
TENDER VALUE 3.44 Lakhs
LAST DATE 28-10-2026
Authority
Authority Name Zilla Parishad
Work Description Tender for Construction Of Water Resevoir At Near Kumverpar Of Sansad No.-16/136 Madhabdanga-1 G.P. Under Maynaguri. Activity Id- 110933128/2025-26(Sl. No. 07)
Basic Detail
Tender No WBGP/01/MAD-I/MNG/2026-27
Bidding Type Tender
Location
City Jalpaiguri
State West Bengal
Key Dates
Publish Date 09 Oct 2026
Submission Date 28 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 3.44 Lakhs
Tender Fee 1000
EMD 6882
Exemption Not Available
Document List
9b2cd3b1-5c73-482b-91d9-574b91497cd3.html
BOQ_5179636.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

9b2cd3b1-5c73-482b-91d9-574b91497cd3.html

xls

BOQ_5179636.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders