Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57961909

Tender For Construction Of Separate Toilet Facilities Within The Court Premises For The Litigant Public(Male And Female) And Also For Use Of The Transgender And The Pwd At Jangipur Sub-Division Court.-Electrical Installation (Ei) Work.

Issued by Government Departments · Murshidabad, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Oct 2026
0 days left
EMD
3711
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Separate Toilet Facilities Within The Court Premises For The Litigant Public(Male And Female) And Also For Use Of The Transgender And The Pwd At Jangipur Sub-Division Court.-Electrical Installation (Ei) Work.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Oct-2026 CORRIGENDUM Date 20-Oct-2026

BOQ

Name of Work:- Construction of separate toilet facilities within the court premises for the litigant public(Male and Female) and also for use of the Transgender and the pwd at jangipur Sub-Division court.-Electrical installation (EI) work.
Sl. No. Item Description
1PART-1:DISTRIBUTION WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
2Group B
3Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Havells /Finolex /Polycab /Mescab /KEI /Currency) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240V 6A 5 pin plug point incl. S&F 240V 6A 3 pin Modular type plug socket & Modular type switch S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish.
4On Board
5Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
62 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
72 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
82 X 4 sq. mm + 1 X 4 sq. mm earth wire
94 X 16 sq. mm + 2 X 6 sq. mm earth wire
10Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1120 mm
1225 mm
13Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
14Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
15100 mm X 100 mm X 60 mm deep
16150 mm X 75 mm X 60 mm deep
17150 mm X 150 mm X 60 mm deep
18PART-2:PLUGS & SOCKETSSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
19Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
20Supplying and fixing modular GI box suitable for 4 modules, complete with 3-pin, 5/6 A modular socket outlet, ISI-marked, including modular base and cover plate suitable for 2 modules, with all necessary accessories, connections and fixing arrangements, complete in all respect as required.
21PART-3:-BDB,PDB Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
224 way (4 + 12), Double door
23Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
242 + 6 way, Double door
25Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Single pole
27Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
2863 A TP
29Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3040 amps
31Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3263 amps
33Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
34160 Amp, 16 KA, TPMCCB
35Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
36Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
37Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)
38Supplying and fixing sheet metal (16 SWG) iron-clad busbar chamber on angle-iron frame on wall, including earthing attachment and painting as required, as per Drawing No. 470 of P.W.D. Specification Book, May 1991, suitable for 415 V, 4-bar, 200 A, with 4 Nos. aluminium busbars of size 50 × 5 mm and length 85 mm each, housed in a sheet-metal box of dimensions 500 × 150 mm, complete in all respects as required.
39PART-4:SUPPLY & LAYING OF CABLES Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Fort Gloster/polycab/KEI]
402 Core 6 Sq. mm
414 core 25 sqmm
42Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
43Upto 35 sq. mm (clamped with 1mm thick saddle)
44Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
45Upto 35 sq. mm
46Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
472 X 6 sq. mm (19mm)
484 X 16 sq. mm (28mm)
49Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS
5040mm dia
51PART-5:SUPPLY & FIXING OF LIGHT FITTINGSSupply & Delivery of 4 feet,220V, 18-20W single commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 502 P1 x T - LED 22 W with Master LED Tube lamp of 1200 mm , 18W 865 T 8I- 2100 ln corresponding to (Wipro / Philips / Crompton/ Havells).
52Supplying & Delivery , 220V,9 Watt LED lamp (Make Philips / Wipro / Bajaj / Crompton/ Havells ) .
53Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
54Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
55Supplying and fixing PVC batten/ angle holder including connections etc. as required.
56Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS.
57PART-6 -- SUPPLY & FIXING OF FANSSupply & delivery of following 240V, AC 50Hz,50W, 48”/1200mm A.C. ceiling fan (3 Star rating minimum ) complete with blades, canopy, fork, rubber, bush etc. including S&F connecting wire for down rod up to 30cm including painting the rod with approved paint (make: Usha Striker PWD, Orient SUMMERCOOL Brown/White or similar other approved brand)1200mm. sweep
58Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required.
59Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
60Supply & Delivery of 230 V, 50 Hz, following sizes metal body heavy duty exhaust fan . Make: EPC / Usha Fans/ Crompton or any approved and recognised brand by EIC..
6112\\"( 300mm ) Speed 900 RPM,48W
629\\"( 225mm ) Speed 900 RPM,48W
63Supply of 250 V 50 HZ high speed oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator ( Make -CG/ Orient/ Usha) 18\\" (450 mm)
64Fixing of Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC.
65Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
66Upto 450 mm sweep
67Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
68PART-7 -- COMPOUND LIGHT Supply & installation LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K/ 5700°K/ 6500°K (As per ), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
6990 watt
70Supply & installationLED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66, IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/ 4000°K/ 5700°K/ 6500°K (As per ), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
7145 watt
72Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
73Inter connection between Loop Box to fittings by 1.1 KV 3 x 1.5 sqmm single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) through 19 mm size PVC pipe incl. necy. fittings as required as per direction of EIC.
74PART-8 -- MISCELENEOUSS&F of timer box of suitable size with front door and locking arrangement with necessary connection, consisting of followings accessories (Make - L&T/ ABB/ Siemens)i. 240V, 25A DPMCB Isolator - 1 no.ii. 240V, 25A, DP Contactor - 2 no.iii. 240V, 6-32A SPMCB - 2 no.iv. 4 way (16A/way) connector for neutral connection - 1 no.v. Digital timer - 1 no.
75S&D 1.5 sq.mm 'FR' stranded Copper Wire Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57961909
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 20-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Separate Toilet Facilities Within The Court Premises For The Litigant Public(Male And Female) And Also For Use Of The Transgender And The Pwd At Jangipur Sub-Division Court.-Electrical Installation (Ei) Work.
Basic Detail
Tender No WBPWD/EE/MsdED/127/e-Q of 26-27
Bidding Type Tender
Location
City Murshidabad
State West Bengal
Key Dates
Publish Date 18 Oct 2026
Submission Date 20 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 3711
Exemption Not Available
Document List
8e64988e-6f9f-43d5-ad76-663b9d84a8ff.html
BOQ_5180581.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

8e64988e-6f9f-43d5-ad76-663b9d84a8ff.html

xls

BOQ_5180581.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender