Bids Are invited for Sitc Of 2 Tr Split And Cassette Type Ac Unit At Te Building Arera Bhopal
Tender Overview
Project Description
Bids Are invited for Sitc Of 2 Tr Wall Mounted Ac - Supplying Of 2 Tr ( Rated Cooling Capacity Not Less Than 6 Kw) Inverter Type 5 Star Rated Wall Mounted Split Air-Conditioner Unit As Per Bee Star Rating Minimum (Iseer) Of 5 With Temperature Control Thermistor Remote Control Unit Filters Rotary / Scroll Type Compressor Copper Tubes For Both Indoor And Outdoor Unit And Installation Testing & Commissioning Of The 2 Tr Inverter Type Split Ac Unit At A Specified Location By Mounting/Fitting Indoor And Outdoor Units At Their Respective Locations Laying And Fixing Of Both Liquid And Hot Gas Lines Inter Connecting Wiring For Both Indoor Outdoor Units Up To 3 Metres Length And Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line Insulating The Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit Leak Testing Entire System Charging Refrigerant Gas In The Unit Making Power Supply Connections From The Power Point Etc Complete As Requiredproviding The Following Up To The Length Of 3 Meter Etc As Required (1) Gas & Liquid Refrigerant Piping Each And (2) Suitable Connecting Electrical Cable Between Indoor And Outdoor Unit (Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier Or Similar Superior Make) , Supply Fixing Copper Piping For Sac - Supplying And Fixing Extra Copper Pipe Line Beyond 3 Meter Suitable For 2 Tr Split Ac For Gas Line And For Liquid Line Of Suitable Dia To Match With The Pipeline Of The Split Type Unit Supplied Along With Suitable Size Rubber Foam/Insulation As Per Manufacturer Recommendation On Surface Of The Wall / Cable Tray I/C Necessary Flare Nuts Suitably Brazing With The Existing Pipe Cl Ing Making Holes In Walls Same Etc As Per Site Requirement (Note The Rate Of Per Meter Length Included Cost Of Both Gas & Liquid Line Insulation Accessories Additional Refrigerant Etc) , Sitc Of 2 Tr Cassette Type Ac - Supplying Of 2 Tr ( Rated Cooling Capacity Not Less Than 7 Kw) Inverter Type 5 Star Rated Four Way Cassette Type Air Conditioner Unit Suitable For False Celling With Temperature Control Thermistor Remote Control Unit Filters Rotary / Scroll Type Compressor Copper Tubes For Both Indoor And Outdoor Unit And Installation Testing & Commissioning Of The 2 Tr Cassette Type Air-Conditioner Unit At A Specified Location By Mounting/Fitting Indoor And Outdoor Units At Their Respective Locations Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line Leak Testing Entire System Charging Refrigerant Gas In The Unit Making Power Supply Connections From The Power Point Etc Complete As Required ( Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier Or Similar Superior Make) , Supply Fixing Of Copper Piping - Supplying And Fixing Copper Pipe Line For Suitable For 2 Tr Cassette Ac Gas Line And For Liquid Line Of Suitable Dia Along With Suitable Size Rubber Foam/Insulation As Per Manufacturer Recommendation On Surface Of The Wall / Cable Tray I/C Necessary Flare Nuts Suitably Brazing With The Existing Pipe Cl Ing Making Holes In Walls Same Etc As Per Site Requirement (Note The Rate Of Per Meter Length Included Cost Of Both Gas & Liquid Line Insulation Accessories Additional Refrigerant Etc) , Supply Laying Of 3X4 Sqmm Copper Cable - Supplying And Laying 3 Core 4 Sqmm Pvc Insulated And Pvc Sheathed Flexible Copper Cable Along With Refrigerant Pipe Or Along With Existing Conduit / Cable Tray I/C Binding With Plastic Tags For Extending Supply From Existing Industrial Socket To Indoor Unit Etc As Required (Make Isi Make) , Supply Fixing Ms Stand - Supplying & Fixing Of Powder Coated Ms Frame Stand Comprising Of Two Numbers Bracket Made Of Heavy Duty Ms Sheet To Accommodate The Condenser (Outdoor) Unit For Fixing On The Wall / Floor With Suitable Diameter And Length Of Anchor Fast Bolts And Making Good Damages Etc As Per Site Requirement , Pvc Braided Drain Pipe - Supplying And Fixing Of Heavy Duty Pvc Braided Pipe Of Suitable Size For 2 Tr Split / Cassette Air Conditioner Unit With Accessories For Drain Water Connection Etc Complete As Required , M S Cable Tray 150 Mm - Supplying And Installing Of 150 Mm Width X 50 Mm Depth X 1 Decimal 6 Mm Thickness Size Of Perforated Painted With Powder Coating M S Cable Trays With Perforation Not More Than 17 Decimal 5 Percentage In Convenient Sections Joined With Connectors Suspended From The Ceiling With M S Suspenders Including Bolts & Nuts Painting Suspenders Etc As Required , M S Cable Tray 300 Mm - Supplying And Installing Of 300 Mm Width X 50 Mm Depth X 1 Decimal 6 Mm Thickness Size Of Perforated Painted With Powder Coating M S Cable Trays With Perforation Not More Than 17 Decimal 5% In Convenient Sections Joined With Connectors Suspended From The Ceiling With M S Suspenders Including Bolts & Nuts Painting Suspenders Etc As Required , Ms Angle Iron - Providing & Fixing Of Ms Angle Iron / Ms Flat For Fabricating Of Outdoor Unit Stand I/C Cutting Welding Painting And Grouting Fixing In The Ground/Floor/Wall/Recess Etc Complete Asreqd
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | SITC of 2 TR wall mounted AC | Supplying of 2 TR ( Rated Cooling Capacity Not Less than 6 kW) inverter type 5 Star rated wall mounted split Air-Conditioner unit as per BEE star rating minimum (ISEER) of 5 with temperature control thermistor remote control unit filters rotary / scroll type compressor copper tubes for both indoor and outdoor unit and Installation Testing & Commissioning of the 2 TR Inverter type Split AC unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations laying and fixing of both liquid and hot gas lines inter connecting wiring for both indoor outdoor units up to 3 Metres length and interconnecting the indoor unit and outdoor unit with refrigerant line insulating the refrigerant pipe with expandable polyethylene Foam tubing unit Leak testing entire system charging Refrigerant gas in the unit making power supply connections from the power point etc complete as requiredProviding the following up to the length of 3 Meter etc as required (1) Gas & Liquid refrigerant piping each and (2) suitable connecting electrical cable between indoor and outdoor unit (Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier or similar superior Make) |
| 2 | Supply fixing Copper Piping for SAC | Supplying and fixing extra copper pipe line beyond 3 meter suitable for 2 TR Split AC for gas line and for liquid line of suitable dia to match with the pipeline of the split type unit supplied along with suitable size rubber foam/insulation as per manufacturer recommendation on surface of the wall / cable tray i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement (Note The rate of per meter length included cost of both gas & liquid line insulation accessories additional refrigerant etc) |
| 3 | SITC of 2 TR Cassette type AC | Supplying of 2 TR ( Rated Cooling Capacity Not Less than 7 kW) inverter type 5 Star rated four way cassette type Air Conditioner unit suitable for false celling with temperature control thermistor remote control unit filters rotary / scroll type compressor copper tubes for both indoor and outdoor unit and Installation Testing & Commissioning of the 2 TR cassette type Air-Conditioner unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations interconnecting the indoor unit and outdoor unit with refrigerant line Leak testing entire system charging Refrigerant gas in the unit making power supply connections from the power point etc complete as required ( Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier or similar superior Make) |
| 4 | Supply fixing of Copper Piping | Supplying and fixing copper pipe line for suitable for 2 TR Cassette AC gas line and for liquid line of suitable dia along with suitable size rubber foam/insulation as per manufacturer recommendation on surface of the wall / cable tray i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement (Note The rate of per meter length included cost of both gas & liquid line insulation accessories additional refrigerant etc) |
| 5 | Supply laying of 3x4 Sqmm copper cable | Supplying and laying 3 core 4 sqmm PVC insulated and PVC sheathed flexible copper cable along with refrigerant pipe or along with existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc as required (Make ISI Make) |
| 6 | Supply fixing MS Stand | Supplying & fixing of Powder Coated MS frame stand comprising of Two numbers bracket made of heavy duty MS Sheet to accommodate the Condenser (Outdoor) unit for fixing on the wall / Floor with suitable diameter and length of Anchor fast bolts and making good damages etc as per site requirement |
| 7 | PVC braided drain pipe | Supplying and Fixing of heavy duty PVC Braided pipe of suitable size for 2 TR Split / Cassette Air Conditioner Unit with accessories for drain water connection etc complete as required |
| 8 | M S Cable Tray 150 mm | Supplying and installing of 150 mm width X 50 mm depth X 1 decimal 6 mm thickness size of perforated painted with powder coating M S cable trays with perforation not more than 17 decimal 5 percentage in convenient sections joined with connectors suspended from the ceiling with M S suspenders including bolts & nuts painting suspenders etc as required |
| 9 | M S Cable Tray 300 mm | Supplying and installing of 300 mm width X 50 mm depth X 1 decimal 6 mm thickness size of perforated painted with powder coating M S cable trays with perforation not more than 17 decimal 5% in convenient sections joined with connectors suspended from the ceiling with M S suspenders including bolts & nuts painting suspenders etc as required |
| 10 | MS Angle Iron | Providing & Fixing of MS Angle Iron / MS Flat for fabricating of outdoor unit stand i/c cutting welding painting and grouting fixing in the ground/floor/wall/recess etc complete asreqd |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender