Communications and Information Technology Government Departments Closing in 16 days TDR #57960393

Bids Are invited for Sitc Of 2 Tr Split And Cassette Type Ac Unit At Te Building Arera Bhopal

Issued by Government Departments · Bhopal, Madhya Pradesh
Tender Value
19.39 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
16 days left
EMD
38780
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
540

Project Description

Bids Are invited for Sitc Of 2 Tr Wall Mounted Ac - Supplying Of 2 Tr ( Rated Cooling Capacity Not Less Than 6 Kw) Inverter Type 5 Star Rated Wall Mounted Split Air-Conditioner Unit As Per Bee Star Rating Minimum (Iseer) Of 5 With Temperature Control Thermistor Remote Control Unit Filters Rotary / Scroll Type Compressor Copper Tubes For Both Indoor And Outdoor Unit And Installation Testing & Commissioning Of The 2 Tr Inverter Type Split Ac Unit At A Specified Location By Mounting/Fitting Indoor And Outdoor Units At Their Respective Locations Laying And Fixing Of Both Liquid And Hot Gas Lines Inter Connecting Wiring For Both Indoor Outdoor Units Up To 3 Metres Length And Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line Insulating The Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit Leak Testing Entire System Charging Refrigerant Gas In The Unit Making Power Supply Connections From The Power Point Etc Complete As Requiredproviding The Following Up To The Length Of 3 Meter Etc As Required (1) Gas & Liquid Refrigerant Piping Each And (2) Suitable Connecting Electrical Cable Between Indoor And Outdoor Unit (Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier Or Similar Superior Make) , Supply Fixing Copper Piping For Sac - Supplying And Fixing Extra Copper Pipe Line Beyond 3 Meter Suitable For 2 Tr Split Ac For Gas Line And For Liquid Line Of Suitable Dia To Match With The Pipeline Of The Split Type Unit Supplied Along With Suitable Size Rubber Foam/Insulation As Per Manufacturer Recommendation On Surface Of The Wall / Cable Tray I/C Necessary Flare Nuts Suitably Brazing With The Existing Pipe Cl Ing Making Holes In Walls Same Etc As Per Site Requirement (Note The Rate Of Per Meter Length Included Cost Of Both Gas & Liquid Line Insulation Accessories Additional Refrigerant Etc) , Sitc Of 2 Tr Cassette Type Ac - Supplying Of 2 Tr ( Rated Cooling Capacity Not Less Than 7 Kw) Inverter Type 5 Star Rated Four Way Cassette Type Air Conditioner Unit Suitable For False Celling With Temperature Control Thermistor Remote Control Unit Filters Rotary / Scroll Type Compressor Copper Tubes For Both Indoor And Outdoor Unit And Installation Testing & Commissioning Of The 2 Tr Cassette Type Air-Conditioner Unit At A Specified Location By Mounting/Fitting Indoor And Outdoor Units At Their Respective Locations Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line Leak Testing Entire System Charging Refrigerant Gas In The Unit Making Power Supply Connections From The Power Point Etc Complete As Required ( Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier Or Similar Superior Make) , Supply Fixing Of Copper Piping - Supplying And Fixing Copper Pipe Line For Suitable For 2 Tr Cassette Ac Gas Line And For Liquid Line Of Suitable Dia Along With Suitable Size Rubber Foam/Insulation As Per Manufacturer Recommendation On Surface Of The Wall / Cable Tray I/C Necessary Flare Nuts Suitably Brazing With The Existing Pipe Cl Ing Making Holes In Walls Same Etc As Per Site Requirement (Note The Rate Of Per Meter Length Included Cost Of Both Gas & Liquid Line Insulation Accessories Additional Refrigerant Etc) , Supply Laying Of 3X4 Sqmm Copper Cable - Supplying And Laying 3 Core 4 Sqmm Pvc Insulated And Pvc Sheathed Flexible Copper Cable Along With Refrigerant Pipe Or Along With Existing Conduit / Cable Tray I/C Binding With Plastic Tags For Extending Supply From Existing Industrial Socket To Indoor Unit Etc As Required (Make Isi Make) , Supply Fixing Ms Stand - Supplying & Fixing Of Powder Coated Ms Frame Stand Comprising Of Two Numbers Bracket Made Of Heavy Duty Ms Sheet To Accommodate The Condenser (Outdoor) Unit For Fixing On The Wall / Floor With Suitable Diameter And Length Of Anchor Fast Bolts And Making Good Damages Etc As Per Site Requirement , Pvc Braided Drain Pipe - Supplying And Fixing Of Heavy Duty Pvc Braided Pipe Of Suitable Size For 2 Tr Split / Cassette Air Conditioner Unit With Accessories For Drain Water Connection Etc Complete As Required , M S Cable Tray 150 Mm - Supplying And Installing Of 150 Mm Width X 50 Mm Depth X 1 Decimal 6 Mm Thickness Size Of Perforated Painted With Powder Coating M S Cable Trays With Perforation Not More Than 17 Decimal 5 Percentage In Convenient Sections Joined With Connectors Suspended From The Ceiling With M S Suspenders Including Bolts & Nuts Painting Suspenders Etc As Required , M S Cable Tray 300 Mm - Supplying And Installing Of 300 Mm Width X 50 Mm Depth X 1 Decimal 6 Mm Thickness Size Of Perforated Painted With Powder Coating M S Cable Trays With Perforation Not More Than 17 Decimal 5% In Convenient Sections Joined With Connectors Suspended From The Ceiling With M S Suspenders Including Bolts & Nuts Painting Suspenders Etc As Required , Ms Angle Iron - Providing & Fixing Of Ms Angle Iron / Ms Flat For Fabricating Of Outdoor Unit Stand I/C Cutting Welding Painting And Grouting Fixing In The Ground/Floor/Wall/Recess Etc Complete Asreqd

BOQ

Sl. No. Item TitleItem Description
1SITC of 2 TR wall mounted ACSupplying of 2 TR ( Rated Cooling Capacity Not Less than 6 kW) inverter type 5 Star rated wall mounted split Air-Conditioner unit as per BEE star rating minimum (ISEER) of 5 with temperature control thermistor remote control unit filters rotary / scroll type compressor copper tubes for both indoor and outdoor unit and Installation Testing & Commissioning of the 2 TR Inverter type Split AC unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations laying and fixing of both liquid and hot gas lines inter connecting wiring for both indoor outdoor units up to 3 Metres length and interconnecting the indoor unit and outdoor unit with refrigerant line insulating the refrigerant pipe with expandable polyethylene Foam tubing unit Leak testing entire system charging Refrigerant gas in the unit making power supply connections from the power point etc complete as requiredProviding the following up to the length of 3 Meter etc as required (1) Gas & Liquid refrigerant piping each and (2) suitable connecting electrical cable between indoor and outdoor unit (Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier or similar superior Make)
2Supply fixing Copper Piping for SACSupplying and fixing extra copper pipe line beyond 3 meter suitable for 2 TR Split AC for gas line and for liquid line of suitable dia to match with the pipeline of the split type unit supplied along with suitable size rubber foam/insulation as per manufacturer recommendation on surface of the wall / cable tray i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement (Note The rate of per meter length included cost of both gas & liquid line insulation accessories additional refrigerant etc)
3SITC of 2 TR Cassette type ACSupplying of 2 TR ( Rated Cooling Capacity Not Less than 7 kW) inverter type 5 Star rated four way cassette type Air Conditioner unit suitable for false celling with temperature control thermistor remote control unit filters rotary / scroll type compressor copper tubes for both indoor and outdoor unit and Installation Testing & Commissioning of the 2 TR cassette type Air-Conditioner unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations interconnecting the indoor unit and outdoor unit with refrigerant line Leak testing entire system charging Refrigerant gas in the unit making power supply connections from the power point etc complete as required ( Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier or similar superior Make)
4Supply fixing of Copper PipingSupplying and fixing copper pipe line for suitable for 2 TR Cassette AC gas line and for liquid line of suitable dia along with suitable size rubber foam/insulation as per manufacturer recommendation on surface of the wall / cable tray i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement (Note The rate of per meter length included cost of both gas & liquid line insulation accessories additional refrigerant etc)
5Supply laying of 3x4 Sqmm copper cableSupplying and laying 3 core 4 sqmm PVC insulated and PVC sheathed flexible copper cable along with refrigerant pipe or along with existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc as required (Make ISI Make)
6Supply fixing MS StandSupplying & fixing of Powder Coated MS frame stand comprising of Two numbers bracket made of heavy duty MS Sheet to accommodate the Condenser (Outdoor) unit for fixing on the wall / Floor with suitable diameter and length of Anchor fast bolts and making good damages etc as per site requirement
7PVC braided drain pipeSupplying and Fixing of heavy duty PVC Braided pipe of suitable size for 2 TR Split / Cassette Air Conditioner Unit with accessories for drain water connection etc complete as required
8M S Cable Tray 150 mmSupplying and installing of 150 mm width X 50 mm depth X 1 decimal 6 mm thickness size of perforated painted with powder coating M S cable trays with perforation not more than 17 decimal 5 percentage in convenient sections joined with connectors suspended from the ceiling with M S suspenders including bolts & nuts painting suspenders etc as required
9M S Cable Tray 300 mmSupplying and installing of 300 mm width X 50 mm depth X 1 decimal 6 mm thickness size of perforated painted with powder coating M S cable trays with perforation not more than 17 decimal 5% in convenient sections joined with connectors suspended from the ceiling with M S suspenders including bolts & nuts painting suspenders etc as required
10MS Angle IronProviding & Fixing of MS Angle Iron / MS Flat for fabricating of outdoor unit stand i/c cutting welding painting and grouting fixing in the ground/floor/wall/recess etc complete asreqd

AI Tender Summary

OUR REF NO 57960393
AUTHORITY Government Departments
TENDER VALUE 19.39 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Department Of Telecommunications
Work Description Bids Are invited for Sitc Of 2 Tr Wall Mounted Ac - Supplying Of 2 Tr ( Rated Cooling Capacity Not Less Than 6 Kw) Inverter Type 5 Star Rated Wall Mounted Split Air-Conditioner Unit As Per Bee Star Rating Minimum (Iseer) Of 5 With Temperature Control Thermistor Remote Control Unit Filters Rotary / Scroll Type Compressor Copper Tubes For Both Indoor And Outdoor Unit And Installation Testing & Commissioning Of The 2 Tr Inverter Type Split Ac Unit At A Specified Location By Mounting/Fitting Indoor And Outdoor Units At Their Respective Locations Laying And Fixing Of Both Liquid And Hot Gas Lines Inter Connecting Wiring For Both Indoor Outdoor Units Up To 3 Metres Length And Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line Insulating The Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit Leak Testing Entire System Charging Refrigerant Gas In The Unit Making Power Supply Connections From The Power Point Etc Complete As Requiredproviding The Following Up To The Length Of 3 Meter Etc As Required (1) Gas & Liquid Refrigerant Piping Each And (2) Suitable Connecting Electrical Cable Between Indoor And Outdoor Unit (Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier Or Similar Superior Make) , Supply Fixing Copper Piping For Sac - Supplying And Fixing Extra Copper Pipe Line Beyond 3 Meter Suitable For 2 Tr Split Ac For Gas Line And For Liquid Line Of Suitable Dia To Match With The Pipeline Of The Split Type Unit Supplied Along With Suitable Size Rubber Foam/Insulation As Per Manufacturer Recommendation On Surface Of The Wall / Cable Tray I/C Necessary Flare Nuts Suitably Brazing With The Existing Pipe Cl Ing Making Holes In Walls Same Etc As Per Site Requirement (Note The Rate Of Per Meter Length Included Cost Of Both Gas & Liquid Line Insulation Accessories Additional Refrigerant Etc) , Sitc Of 2 Tr Cassette Type Ac - Supplying Of 2 Tr ( Rated Cooling Capacity Not Less Than 7 Kw) Inverter Type 5 Star Rated Four Way Cassette Type Air Conditioner Unit Suitable For False Celling With Temperature Control Thermistor Remote Control Unit Filters Rotary / Scroll Type Compressor Copper Tubes For Both Indoor And Outdoor Unit And Installation Testing & Commissioning Of The 2 Tr Cassette Type Air-Conditioner Unit At A Specified Location By Mounting/Fitting Indoor And Outdoor Units At Their Respective Locations Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line Leak Testing Entire System Charging Refrigerant Gas In The Unit Making Power Supply Connections From The Power Point Etc Complete As Required ( Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier Or Similar Superior Make) , Supply Fixing Of Copper Piping - Supplying And Fixing Copper Pipe Line For Suitable For 2 Tr Cassette Ac Gas Line And For Liquid Line Of Suitable Dia Along With Suitable Size Rubber Foam/Insulation As Per Manufacturer Recommendation On Surface Of The Wall / Cable Tray I/C Necessary Flare Nuts Suitably Brazing With The Existing Pipe Cl Ing Making Holes In Walls Same Etc As Per Site Requirement (Note The Rate Of Per Meter Length Included Cost Of Both Gas & Liquid Line Insulation Accessories Additional Refrigerant Etc) , Supply Laying Of 3X4 Sqmm Copper Cable - Supplying And Laying 3 Core 4 Sqmm Pvc Insulated And Pvc Sheathed Flexible Copper Cable Along With Refrigerant Pipe Or Along With Existing Conduit / Cable Tray I/C Binding With Plastic Tags For Extending Supply From Existing Industrial Socket To Indoor Unit Etc As Required (Make Isi Make) , Supply Fixing Ms Stand - Supplying & Fixing Of Powder Coated Ms Frame Stand Comprising Of Two Numbers Bracket Made Of Heavy Duty Ms Sheet To Accommodate The Condenser (Outdoor) Unit For Fixing On The Wall / Floor With Suitable Diameter And Length Of Anchor Fast Bolts And Making Good Damages Etc As Per Site Requirement , Pvc Braided Drain Pipe - Supplying And Fixing Of Heavy Duty Pvc Braided Pipe Of Suitable Size For 2 Tr Split / Cassette Air Conditioner Unit With Accessories For Drain Water Connection Etc Complete As Required , M S Cable Tray 150 Mm - Supplying And Installing Of 150 Mm Width X 50 Mm Depth X 1 Decimal 6 Mm Thickness Size Of Perforated Painted With Powder Coating M S Cable Trays With Perforation Not More Than 17 Decimal 5 Percentage In Convenient Sections Joined With Connectors Suspended From The Ceiling With M S Suspenders Including Bolts & Nuts Painting Suspenders Etc As Required , M S Cable Tray 300 Mm - Supplying And Installing Of 300 Mm Width X 50 Mm Depth X 1 Decimal 6 Mm Thickness Size Of Perforated Painted With Powder Coating M S Cable Trays With Perforation Not More Than 17 Decimal 5% In Convenient Sections Joined With Connectors Suspended From The Ceiling With M S Suspenders Including Bolts & Nuts Painting Suspenders Etc As Required , Ms Angle Iron - Providing & Fixing Of Ms Angle Iron / Ms Flat For Fabricating Of Outdoor Unit Stand I/C Cutting Welding Painting And Grouting Fixing In The Ground/Floor/Wall/Recess Etc Complete Asreqd
Basic Detail
Tender No GEM/2026/B/8141117
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 09 Oct 2026
Submission Date 30 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 19.39 Lakhs
Tender Fee Ref. Documents
EMD 38780
Exemption Not Available
Document List
203e77ec-f26a-4313-94be-4ee1e37506fb.pdf
nitnocsac_2026-10-09-16-50-59_b5bb9016af6fb2f1b44bb692b2465f9e.pdf
10012446_Boq_1.xlsx
NITNOCSAC_c22389ce-c993-4c9b-acb81791546794508_SDEEPMM2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

203e77ec-f26a-4313-94be-4ee1e37506fb.pdf

pdf

nitnocsac_2026-10-09-16-50-59_b5bb9016af6fb2f1b44bb692b2465f9e.pdf

xlsx

10012446_Boq_1.xlsx

pdf

NITNOCSAC_c22389ce-c993-4c9b-acb81791546794508_SDEEPMM2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender