Tender For Special Repair To Bldg No T-09, T-35, T-36 & T-37 At Surankote And T-18 At Jhullas Under Age B/R-Iii Of Ge 881 Ews
Tender Value
44.80 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
13 days left
EMD
89600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No T-09, T-35, T-36 & T-37 At Surankote And T-18 At Jhullas Under Age B/R-Iii Of Ge 881 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: SPL REPAIR TO BLDG NO T-09, T-35, T-36 & t-37 AT SURANKOTE AND T-18 AT JHULLAS UNDER AGE B/R-III OF GE 881 EWS Contract No : GE/PNH-70/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | B/R Portion:Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering, all as specified & directed. |
| 3 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 4 | Demolition of cement concrete (un- reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level complete all as specified and as directed. |
| 5 | Demolition of cement concrete (reinforced) of any description and in any position,complete all as specified and directed. |
| 6 | Taking down chowkhats or frames n. exc 1.5 Sqm but (without taking off shutters from frame) complete all as specified and directed. |
| 7 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each, complete all as specified and directed. |
| 8 | Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed. |
| 9 | Rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 410W(Gde E-250), quality 'B' complete all as specified and directed. |
| 10 | Mild steel rolled section in purlin, main and cross beam, rafter, posts etc including connected cleats, hold fast etc of grade conforming to Fe 410-W (Gde E-250 quality A) complete all as specified and directed. |
| 11 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed by Engineer- in Charge. |
| 12 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified and directed by Engineer- in Charge. |
| 13 | Applying two coats of synthetic enamel paint of Ist quality over a coat of red oxide zinc chrome primer to new or previously untreated steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed. |
| 14 | Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 15 | Walling of random rubble stone masonry, brought upto courses , well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed. |
| 16 | Description all as per item no. 14 above but except stone (using old serviceable stone after cleaning) complete all as specified and directed. |
| 17 | 50 mm thick PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 18 | Rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 19 | Rendering 15mm thick on other than fair faces of brick or stone masonry wall surfaces on walls in cement mortar 1:6 and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 20 | Preparation of newly plastered or unplastered surface of wall and applying two coats of cement base paint in camouflage pattern over a coat of Primer complete all as specified and directed. Note:- Camouflage pattern shall be approved by Engineer in charge. |
| 21 | Preparation of newly plastered or unplastered surface and applying three coats of white wash complete all as specified and directed. |
| 22 | Factory made pressed steel frames of size 105x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & PCC 1:3:6 type C-0 in back filling of chowkats & tarring back of chowkats and hold fasts complete all as specified & directed. |
| 23 | 35mm thick 2nd class hard wood(Sal/Hollock) plain, framed, panelled door shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified & directed. |
| 24 | 35mm thick 2nd class hard wood (Sal/Hollock) Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified & directed. |
| 25 | Factory made steel windows/ventilators double shutter box type outer frame made of ERW tube ‘P’ section (65 x 45 x 25mm) and shutters of ERW tube ‘P’ (50 x 35 x 20mm) openable shutters side hung including pintol hinges with two Nos of MS tower bolts 150mm size on each shutter steel handle and stopper of ‘Z’ section as specified complete with sash bars dovetailed or welded ready for glass fixing and wire gauge fixing. Steel windows will be double shutter external glazed and internal wire gauged, complete all as specified, as shown in Drg No. CEPZ/TD-324/07 Sheet 1/3 to 3/3 and as directed by Engr-In-Charge. Notes : The quoted rate shall also include :- (i) Provision of one shop coat of red oxide zinc chrome primer on all exposed steel surfaces and one coat of tar coal on the ends of steel frame in contract with brick / concrete surface. (ii) 04 Nos MS steel lugs 20x5mm MS flat 20cm long over all welded to frame (iii) PCC block for embedding lugs all as directed. |
| 26 | Aluminium anodised, barrel tower bolts of extruded section of size 150 and fixed, complete all as specified and directed. |
| 27 | Extruded aluminium alloy handles, fabricated type, anodised of size 150 mm and fixed, complete all as specified and directed. |
| 28 | Extruded aluminium alloy handles, fabricated type, anodised of size 100 mm and fixed, complete all as specified and directed. |
| 29 | 250mm long aluminium alloy anodized sliding door with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed. |
| 30 | Sheet glass ordinary quality, 3mm thick, glazing with rubber neoprene packing to aluminium frame in squares not exceeding 0.50 Sqm in each pane, fixed in repairs, complete all as specified. |
| 31 | Stainless steel wire cloth 0.36 nominal dia of wire and average width of aparture 1.40mm and fixed with tinned tacks or aluminium wire staples, complete all as specified & directed. |
| 32 | 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in flooring including finishing surface even and fair without using extra cement, complete all as specified and directed. |
| 33 | 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base of floor and surface finished even and fair, complete all as specified and directed. |
| 34 | Reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in foundation, including rafts, footings, foundation beams, plinth beams, bases columns, basement slab, under reamed piles and mass concreting complete all as specified and directed. |
| 35 | Reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in chajjas complete all as specified and directed. |
| 36 | Reinforced cement concrete (nominal mix) 1:2:4 type B-1 (using 20mm graded aggregate) in beams, cantilevers, bresssummers, lintel over 1.5m span etc complete all as specified and directed. |
| 37 | Formwork to sides and soffits of flat surfaces of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers including supports, overhangs etc also splays between floors and beams etc, for rough finished surface complete all as specified and directed. |
| 38 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed. |
| 39 | Description all as per srl item 37 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 40 | S&F in repair MS powder coated decorative aluminum curtain rod 25mm dia with decorative head on both end of rod and necessary clamps / fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 41 | Preparation of new wooden surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer,complete all as specified & directed. |
| 42 | Complete removal of existing treatment on walls and applying a coat of 2mm thick wall care putty and applying two coats of Oil Emulsion Distemper (any tint) over a coat of primer complete as specified and directed. |
| 43 | Complete removal of existing treatment on walls and applying two coat of cement base paint (any tint), camouflage pattern as approved by Engr-in-charge, on walls complete as specified and directed. |
| 44 | Taking down cement plaster from brick or stone walls hacking for keys & scrubbing down with water including raking of joints etc as in patches complete all as specified and directed. |
| 45 | Rendering 5mm thick on fair faces of ceiling using cement mortar 1:3 and finished the surface even and smooth without using extra cement, complete, all as specified and directed. |
| 46 | Preparation of newly plastered or unplastered surface of wall and applying two coats of Oil Bound Distemper (any tint) over a coat of primer including 2mm thick wall care putty complete all as specified and directed |
| 47 | Preparation of newly plastered or unplastered surface on ceiling and applying three coats of white wash complete all as specified and directed. |
| 48 | Coloured Ceramic tiles 7-8 mm thick area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4,complete all as specified and as directed by Engr-in-Charge |
| 49 | All as per item no 47 above but in vertical surfaces such as skirtings, dados and risers to steps etc including 10mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 50 | Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 51 | Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 52 | Chequered cement concrete tiles 300x200x25mm thick, set & jointed in neat cement slurry in floors and pointed in white or coloured cement mixed with pigments to match with the colour of tiles, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 53 | Dismantling floor, hearth, or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 54 | Glazed ceramic coloured tiles of size 300x200mm/450x350mm x 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick back coat layer in cement mortar 1:4, complete all as specified and directed by Engr-In-Charge. |
| 55 | Dismantling of wall/ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 56 | False ceiling calcium silicate fissured pattern semi perforated butt edge ceiling tiles , of size 600mm x 600mm x 4mm thick having thermal conductivity K=0.15 W/mOK, having fire performance (BS-476) fixed with and including grid system hot dipped galvanised steel section, exposed surface with pre-coated capping, main tee of size 24 x 38 mm, having 0.25mm gauge at every 1200 mm centre to centre maximum and rotary stitched cross tee of size 24 x 38 mm having 0.25 mm gauge at every 600mm c/c and sub cross tee of size 24 x 38mm, having 0.25 mm gauge at 1200 mm c/c and wall angle of size 19 x 19mm, having 0.35mm gauge fixed to the periphery of the wall and suspended with hangers at every 1200 mm c/c in both directions using 4.0mm dia pre-straightened GI wire fixed with suitable cleats and fastners complete all as specified and directed.. |
| 57 | Factory made pressed steel frames of size 125x60mm made out of PBI sheet 1.25 mm thick for doors with one or more rebates including necessary fixing lugs, hinge,lock strike plate etc.complete including bottom of each chowkat to be welded with 02 Nos 25x3mm thick Flat iron projecting 10cm on either side & tarring back of chowkats and hold fasts complete all as specified & directed. |
| 58 | S&F in repair 25 mm dia stainless steel tubular curtain rod, fancy type, conforming to grade not less than S-304 complete all as specified and directed. |
| 59 | Stainless steel decorative curtain rod 25mm dia with decorative head on both end of rod and necessary clamps / fixing brackets, stops, rollers etc, conforming to grade not less than S-304 complete all as specified and as directed. |
| 60 | Rendering 15mm thick on fair faces of brick or concrete wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 61 | 25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of flooring, finishing surface even and fair , complete all as specified and directed. |
| 62 | E/M Portion:-Taking down carefully copper/ aluminium unserviceable/ perished point wiring with casing caping (light, fan, socket or power complete) including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site and making good disturbed surfaces of wall, floors, complete all as specified and directed. |
| 63 | Point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed copper conductor cable as earth continuity to common earth and connecting to earth dolly drawing in and including PVC heavy duty concealed conduit imcluding accessories such as bend, junction box, connectors and SS boxes wioth requisite accessories for mounting switches, sockets, fan regulators etc for following point wiring, complete all as specified and directed:-Note:-The colour coding of wiring to be followed as Red/Yellow/Blue for Phase/Neutral/Earth respectively. |
| 64 | One light/fan point (Ceiling and Exhaust) controlled by one switch complete all as specified and directed. |
| 65 | One 5 Pin switch socket combination 6 Amp on independent board complete all as specified and directed. |
| 66 | One 5 Pin switch socket combination 6 Amp on same board complete all as specified and directed. |
| 67 | Description all as per item No. 62 here-in-before but for 3 Pin socket outlet 15 Amps point on independent board controlled by other switches with 4.00 sqmm copper conductor PVC insulated cable 1100 Volts grade with 4.00 sqmm copper conductor as earth wire, complete all as specified and directed |
| 68 | Ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed. |
| 69 | Switch piano flush type 5 Amp single pole one way, (ISI marked), complete all as specified and directed. |
| 70 | Socket outlet multipurpose combination 2 in 1, 3 pin, 6 Amp flush type universal,complete all as specifed and directed. |
| 71 | Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal,complete all as specifed and directed. |
| 72 | Switch socket multipurpose combination 2 in 1, 5 pin, 5 and 15 Amp flush type universal,complete all as specifed and directed. |
| 73 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I including providing alternate layers of common salt and charcoal arround earth plate, connected to earth test point all as specified or indicated including excavation and connected earth work in any of soil, P.C.C 1:3:6 type C-1 as in pit, 15mm dia GI pipe medium grade for watering pipe, 15mm bore GI light grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, testing on completion including dismantling unserviceable earthing complete all as specified and directed. |
| 74 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable size and aluminium lugs for connection complete all as specified and directed. NOTE:- Excavation, earthwork, sand cushioning, brick protection shall be measured and paid separately. |
| 75 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth forlaying of cables etc. and getting out in any type of soil, complete all as specified and directed. |
| 76 | Removing excavated material (soil) exceeding 250m but not exceeding 500m and deposition where dircted at a level not exceeding 1.50m above the starting point, all as specified and directed. |
| 77 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, in any type of soil, complete all as specified and directed. |
| 78 | Approved quality clean dry sharp sand as in cushioning to under ground cable laying 15cm thick before laying and 8cm after laying the cable in trenches for cable cushioning, complete all as specified and directed. |
| 79 | M&L for laying of well burnt bricks locally available, laid flat for protection of under ground cable complete all as specified and directed. |
| 80 | Tubes, 40 MM 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 81 | S&F in replacement conneting, and commissioning of street light fitting 30 watt LED, IP-65 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 5 KV, prewired including three core PVC insulated , sheathed 1.5 sqmm multistranded aluminium conductor with 2 core 1.5 sqmm pvc insulated cable from junction box to light fitting complete all as specified and directed. |
| 82 | Street light bracket made out of GI tubing 40mm bore, light grade, 1.5 metre long bent to shape as directed, including suitable MS clamp of F.I. 50 x 6mm with MS bolts, nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint complete all as specified and directed. |
| 83 | S&F in Replacement of old unserviceable DB's with wooden board / boxes S&F distribution board , IP 43 in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN (08 Way double door) Make: Legrand or equivalent in ABB/Schneider and making good the disturbed surface all as directed by Engg-in-charge. |
| 84 | S&F MCB SPN 63 Amps 240V, \\"C' series complete all as specified and directed. |
| 85 | S&F MCB SPN 40 Amps 240V, \\"C' series complete all as specified and directed. |
| 86 | S&F MCB single pole 6 to 32 Amps, 10 KA, \\"C' series complete all as specified and directed. |
| 87 | Supply and fixing Inverter LED batten 20W with square profile and polycarbonate channel, lithium Ion battery with charging time 8 Hours-10 Hours and backup time upto 4 Hours with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 88 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFMwith service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC complete and as directed by engineer-in-charge. |
| 89 | Step type fan regulator electronic type in 5 step, 100 watt capacity switch/socket type complete all as specified and directed. |
| 90 | Lamp holder insulated body all as specified and as directed. |
| 91 | Inverter LED Lamp, CDL, 12 watt, B22 base all as specified and as directed. |
| 92 | S&F in repair switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flusy type universal ISI Marked . complete all as specified and directed. |
| 93 | LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 94 | Submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 6 Sqmm (nominal area) each and one single core 6 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping, incl taking down old u/s complete all as specified and directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate. (ii) Two run of 6 Sqmm and one run of 6 Sqmm copper cable shall be measured as one length. |
| 95 | S&F in replacement conneting, and commissioning of street light fitting 35 watt LED, IP-65 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 5 KV, prewired including three core PVC insulated , sheathed 1.5 sqmm multistranded aluminium conductor with 2 core 1.5 sqmm pvc insulated cable from junction box to light fitting complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender