Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57956498

Tender For Special Repair To Retaining Wall, Otm Bldg And Allied Works In 33 Mtn Bde Coy At Dharamshala Under Ge Pal Ur

Issued by Statutory Bodies & Commissions/Committees · Kangra, Himachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Oct 2026
13 days left
EMD
93000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Retaining Wall, Otm Bldg And Allied Works In 33 Mtn Bde Coy At Dharamshala Under Ge Pal Ur

BOQ

Name of Work:- Special repair to retaining wall, OTM Bldg and allied works in 33 Mtn Bde Coy at Dharamshala under GE Pal ur
Sl. No. Item Description
1Taking down chowkhats of frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) complete all as specified and as directed.
2All as per Srl Item No1 above but exceeding 1.5 Sqm and n.exc 4 Sqm(without taking off shutters from the frames) complete all as specified and as directed.
3S&F 35mm thick factory made plain framed panelled shutters of 2nd class hard wood two panel with lock rail and panel of 9mm thick BWP commercial ply. The size of rail and stile as per IS-1003 (Part-I) Kiln seasoned and chemically pressure treated factory made shutters wood is to be incorporated complete all as specified and as directed.
4S&F pressed steel frame made out of MS sheet 1.25mm thick of size 105x60 mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed.
5PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in back filling of chowkhat complete all as specified and as directed.
6S&F Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consisting two Nos sash bar of T-section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 No's for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf, (iii) MS tower bolt 150mm long - 2 No per leaf (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge - 1 No per leaf, (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf, (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge, complete all as specified & directed.
7Supply and fixing steel ventilators with centre hung shutter including two pairs of brass cup pivoted catch spring and pulley wheel complete all as specified and as directed.
83mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares size n exc 0.5 sqm in each pane all as specified and directed.
9S & F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded setion or cast aluminium alloy and fixed 250 mm long.complete all as specified and as directed.
10S & F anodised aluminium barral tower bolt extruded section 200 mm size.complete all as specified and as directed.
11S & F anodised aluminium handle cast type 125 mm size.complete all as specified and as directed.
12Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, or galvanized wire staples complete all as specified and as directed.
13Preparation of new or previously untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
14M&L for two coat of synthetic enamel paint over a coat of pink primer on new or previously untreated wooden based or wood Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and as directed.
15Taking down cement plaster on brick walls or stone walls any description etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
16Rendering 10mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement complete all as specified and as directed.
17M&L for 15mm thick cement plaster in CM 1:4 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
18M&L for (non skid), premium class I grade, coloured ceramic tiles, 7 to 8mm thick Sqm (square/rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 complete, complete all as specified and as directed.
19M&L non skid ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm on vertical surfaces such as skirtings/dado etc., set and jointed in neat cement slurry and pointed with white or coloured cement, laid over and including 10mm thick bedding layer in cement mortar 1:4 on surfaces of walls complete all as specified and as directed.
20M&L for (non skid), premium class I grade, coloured ceramic tiles, 7 to 8mm thick Sqm (square/rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 complete all as specified and as directed.
21Demolition of cement concrete in ground floors and paving, not exceeding 15cm thickness Cum (below or above ground level), un-reinforced, complete all as specified and as directed.
22Taking down cement plaster/terrazo dado/wall tiling and skirting. etc on brick or stone walls etc including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
23M&L for glazed ceramic coloured tiles, premium class I grade, of size 300mm x 450mm x 7mm Sqm thick as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white or coloured cement, laid over and including 10mm thick bedding layer in cement mortar 1:4 on surfaces of walls complete all as specified and as directed.
24Taking down GI pipe of 15mm bore etc. complete all as specified and as directed.
25S&F 15mm bore GI tubing medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor/wall complete all as specified and as directed.
26Refixing only old GI tubing 15 mm bore pipe and connections in new or old position as on walls ceiling floors etc complete all as specified and as directed.
27Taking down GI pipe of 20mm bore etc. complete all as specified and as directed.
28S&F 20mm bore GI tubing medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor/wall.complete all as specified and as directed.
29Cutting chases, pinning in, making good to facings where required and pointing in cement RM mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed water complete all as specified and as directed.
30S&F Glass/PTMT shelf with CP railing fancy type complete all as specified and as directed.
31S&F Glass/PTMT corner shelf with CP railing fancy type complete all as specified and as directed.
32S&F in repair Vitreous China wash basin, angle back, size 600x480mm white, including cutting for and pinning in ends of brackets or erecting stand including 15mm pillar taps, with 32mm chromium plated waste coupling, waste pipe of bore 32mm, PVC connection pipe 450mm long with brass nuts on both side, fixed in repairs, including bracket,s complete all as specified and as directed.
33S & F Vitreous china wash down water closet pan (pedestal pattern), white and trap including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc seat and cover for pedestal pan . Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in posisition complete in all respect all as specified and directed.
34S&F PVC valve less, crystal white, syphonic action type flushing cistern 10 liter capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32mm dia PVC long bend flush pipe 90cm long and 15mm dia 450 mm long PVC connection with CP brass coupling nuts and PVC washers at bothy ends fixed, in repairs,complete all as specified and as directed.
35S&F vitreous china urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (Inclusive of fixing supply pipe to flushing cistern, trap and waste pipe) incl urinal spreader complete all as specified and as directed.
36S&F 15mm bore Bip taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated and fixed in repairs complete all as specified and as directed.
37S & F 15 mm bore CP brass stop valve cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
38S & F in repairs brass chromium plated tubular towel rail, 20mm dia, D type 60cm long between flanges complete all as specified and as directed.
39S & F in repairs Toilet paper holder recessed type stainless steel complete all as specified and as directed.
40S & F in repairs CP grating (with or without waste hole), 125 mm size, fixed on floor/nahani traps etc complete all as specified and as directed.
41S&F (600mm x 450mm) bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood with aluminium frame 15 x 15 and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
42S&F CP soap tray fixed to walls with rubber plugs complete all as specified and directed.
43Demolition of stones or brick masonry/rcc wall built in cement mortar including all quoins, arches etc. but excluding ashlar facing, dressed stone work etc. complete all as specified and as directed.
44M&L for stone walling of random rubble with best quality locally available harder stone such as granite, trap or basalt brought upto courses well bonded bedded, solidly hearted and built in cement mortar 1:6, complete all as specified & directed.
45All as per Srl item No. 44 above but except stone complete all as specified and as directed.
46M & L PCC 1:3:6 type C2 (40mm graded ) as in plinth protection 75mm thick complete all as specified and as directed.
47S&F 25 mm curtain rod, colour coated with wooden bracket and wooden funnel over door and window fixed with steel screw and PVC cleat complete all as specified and as directed.
48Preparation of plastered surface of wall by applying 1.5 mm wall care putty in two layer and making the surface smooth with sand paper and applying two coat of OBD over new/old surfaces complete all as specified and as directed.
49Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new /old surfaces complete all as specified and as directed.
50Dismantling of corrugated or plain steel sheeting of any gauge thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
51Pre pantined galvalume aluminum zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding fixed with self tapping screws complete all as specified and as directed.
52Pre pantined galvalume aluminum zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed.
53M&L false ceiling using anodised aluminium T&L sections, snap grid frame work of size 600 x 600mm including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long complete with 4mm thick non-asbestos fibre cement board ISI marked Eboard colour coated and designed, complete all as specified and as directed.
54Dismantling of wall & ceiling boarding (fibre, pulp, insulation etc.., or insulation board/slab/blankets, any thickness, with nails, including cover fillets and removing from site complete all as specified and as directed.
55Dismantling of framed work timber scantlings 40 Sqcm and over in section, in any position.complete all as specified and as directed.
56Material and labour for 2nd class hard wood as in scantling, framed work as in ceiling, clean swan timber and fixed in any position complete all as specified and as directed.
57M&L machine cut kota stone slab flooring 18-20mm thick over cement screed base laid over 15mm screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
58All as per item No 57 above but on vertical surfaces over 10 mm thick plastering in cement mortor1:4 complete all as specified and as directed.
59M&L for Chequered cement concrete tiles with grey cement and not pigment .30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 15mm thick screed bedding layer in cement mortar 1:6 complete all as specified and as directed.
60PCC M-15, nominal mix, type B-1, using 20mm graded mechanically crushed stone aggregate as in floors, 25mm thick, finished even and rough to receive floor finishes, complete all as specified and as directed.
61M&L PCC (1:2:4) type B-1 using 20 mm graded stone agg as in coping, benching cills, pcc gola,roof kerbs and the like including weathering slgitely rounded or chamfered on edges directed mixed with water proofing compound (water proofing compound shall be measured separately) complete all as specified and as directed.
62M & L for Cement concrete type C2 (1:3:6) in foundations, filling and mass concrete using 40mm graded aggregate complete all as specified and as directed.
63M & L for walling of random rubble stone masonry brought upto course well bonded bedded and solidly hearted built in CM 1:4 but except stone complete all as specified and as directed.
64M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:4 brought upto courses complete all as specified and as directed.
65PCC M-15 (Nominal Mix ) Using 20mm graded crushed stone aggregate as in coping including necessary formwork complete all as specified and directed.
66Precast cement concrete M-15 (Nominal Mix ) Using 20mm graded crushed stone aggregate as Bond stone including necessary formwork complete all as specified and directed.
67M & L for Hand packing of Broken stone or boulders (any thickness) at back of walls over areches etc. and raising (or lowering) to the required level complete all as specified and as directed.
68PVC (SWR) pipe 110mm dia of pressure rating 4kg/Sqcm fixed in retaining wall complete all as specified and as directed.
69Extra over stone walling for hammer dressing with maximum despression from a straight edge held against the surface not exceeding 40mm dressing on sand stone complete all as specified and as directed.
70Raised pointing to random rubble walling uncoursed in cement mortar 1:4 complete all as specified and as directed.
71Wire netting of stainless steel wire 1.4mm dia and mesh size 12 mm fixed with tinned tacks of stainless steel wire staples complete all as specified and as directed.
72Excavating over areas, n exc 1.5 m deep and getting out in hard dense soil complete all as specified & directed.
73Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and as directed.
74Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed.
75Taking down carefully copper/aluminium point wiring for light, fan, bell, socket or power complete including all fittings such as switches, ceiling roses pendants regulators, sockets and tube light fittings etc, removing materials from site and making good distributed surface of wall, floors, etc, complete all as specified and as directed.
76Taking down main switches/ DBs with sheet metal enclosure complete all as specified and as directed.
77Dismantling of house service brackets of any size and type and making good the disturbed wall surfaces complete all as specified and as directed.
78Material and labour for point wiring complete with 1.5 Sqmm PVC insulated unsheathed 1100 volts, grade cable stranded copper conductor single core in casing caping of 20/25 mm size complete with PVC rectangular block with 3mm thick plastic laminated sheet for mounting switch/ sockets regulators etc and with 1.5 Sqmm PVC insulated copper earth wire and connected to earth dolly for one light/fan point controlled by one switch complete all as specified and as directed
79All as per serial item No. 78 above but for 3 pin socket outlet point controlled by one, one way switch on the same board
80All as per serial item No. 78 above but for one 3 pin socket cobination of 5 Amp capacity on independent board
81All as per serial item No. 78 above , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm cropper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed.
82Supply and fix switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type complete all as specified and as directed.
83Supply and fix switch piano type 5 Amp single pole one way complete all as specified and as directed
84Supply and fix switch socket outlet 3 pin 5 Amp flush type complete all as specified and as directed
85Supply and fix switch socket combination 2 in 1 , 3 pin 5 Amp flush type complete all as specified and as directed.
86Supply and fix ceiling rose surface backelite three terminal complete all as specified and as directed.
87Supply and fixing PVC body Exhaust fan 200/250 mm sweep, 5 star rating, 230 V AC, copper binding, blades, frame and, louverscomplete all as specified and as directed.
88Supply and fix LED tube light fittings 1 x 20 Watt 220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed
89Supply and fix lamp holder, PVC/Polycarbonate type complete all as specified and as directed.
90Supply and Fixing wall security LED light fittings of Cap 18 W suitable for New generation energy saving and environmental friendly long life, light made up of pressure die cast aluminium housing with highly efficient LEDs as Lighting Source and PC cover with integrated lens with IP66 protection and impact resistance of Ik07 complete all as specified and directed
91Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 Watt, 220 V AC recessed type with high efficient PMMA diffuser soft glare-free light complete with driver, holders, & LED lampsuitable for roof ceiling; including connecting up with three core flexible copper connector cable of suitable size including taking down old unserviceable one complete all as specified and as directed.
92Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 kA rating complete all as specified and as directed.
93Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 kA ratingcomplete all as specified and as directed.
94Supply and fix sheet metal enclosure powder painted for MCB SPN 8 way DB double door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed.
95Supply and laying XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 2 core including taking down of old unserviceable one complete all as specified and as directed.
96Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation of pole etc and getting out in any type of soil complete all as specified and as directed.
97Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5 mtr from the starting point complete all as specified and as directed.
98Supply and laying High density polyethylene pipes (HDPE), for cable protection of pressure rating 6 kg/cm2 laid in trenches of size 25 mm Bore complete all as specified and as directed.
99M&L for GI pipe light grade 40 mm dia fixed to pole laid in tranches for cable protection complete all as specified and as directed.
100S&F bracket for bldg security light made out of 25 mm GI tubing medium grade 0.60 Mtr long bend to required shape as in bracket for bldg security light fittings, incl drilling hole in pipe for fixing with nut, bolt/screw in building wall complete all as specified and as directed
101S & F PVC rectangular block for mounting, DBs etc with 3mm thick plastic laminated sheet cover of size 250x200x50 mm deep complete all as specified and as directed.
102M & L for earthing complete with galvanised steel earth plate electrode 60x60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57956498
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 30-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Retaining Wall, Otm Bldg And Allied Works In 33 Mtn Bde Coy At Dharamshala Under Ge Pal Ur
Basic Detail
Tender No GEP-94/2026-27
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 09 Oct 2026
Submission Date 30 Oct 2026
Open Date 06 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 93000
Exemption Available
Document List
BOQ_889468.xls
cfd487da-0c3c-47e0-87ae-57632179356e.html
td.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_889468.xls

html

cfd487da-0c3c-47e0-87ae-57632179356e.html

pdf

td.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender