Tender For special Repair / Replacement Of Lt Cable At Neel Bhawan And Vikram Batra Enclave Under Ge (East) Ferozepur Cantt
Tender Value
38.83 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
1 days left
EMD
77660
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair / Replacement Of Lt Cable At Neel Bhawan And Vikram Batra Enclave Under Ge (East) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cable, pole foundation, etc including taking out old brick cable protection cover and getting out forming bottom surface to required gradient, complete all as specified and directed. |
| 2 | Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25 cm thick each layer, complete all as specified and directed. |
| 3 | Removal of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point, complete all as specified and directed. |
| 4 | Material and labour for sand cushioning with fine sand for cable protection laid in trenches 8 cm before laying of cable and 15 cm after laying and stretching the cable, complete all as specified and directed.Note:- Punned down thickness as laid down in SSR Part I shall be measured and paid. |
| 5 | Material and labour brick protection layer for cables laid in trenches using sub-class ‘B’ bricks laid dry width wise acrose the line of cable (perpendicular to the direction of cable), complete all as specified and directed. |
| 6 | Dismantling and taking down old UNSV LT UG cable of any type and size complete all as specified and directed. |
| 7 | Supply & laying & testing in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured ,aluminium conductor, electric power cable (heavy duty) of size 400 Sqmm 3.5 Core1100 Volts. Note: Rate of underground cable excludes earth work, sand cushioning, brick of PCC/RCC covering, light grade GI tubing where necessary, etc, quantity of the same will be measured and paid separately. |
| 8 | ll as per item No 07 here-in-before but size 240 sq mm 3.5 core complete all as specified & directed. |
| 9 | ll as per item No 07 here-in-before but size 95 sq mm 3.5 core complete all as specified & directed. |
| 10 | ll as per item No 07 here-in-before but size 70 sq mm 3.5 core complete all as specified & directed. |
| 11 | ll as per item No 07 here-in-before but size 50 sq mm 3.5 core complete all as specified & directed. |
| 12 | ll as per item No 07 here-in-before but size 35 sq mm 3.5 core complete all as specified & directed. |
| 13 | ll as per item No 07 here-in-before but size 25 sq mm 4.0 core complete all as specified & directed. |
| 14 | Dismantling and taking down old worn out ACSR conductor of any type and size, complete all as specified and directed. |
| 15 | Dismantling & taking down old worn out MS clamps/cross arms/channels complete with nuts & bolts etc, complete all as specified and directed. |
| 16 | Dismantling insulators any type, any size, complete all as specified and directed. |
| 17 | Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet duly powder coated with pure polyester based paint on both externally and internally. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands, complete all as specified & directed.Base frame of the panel shall be made of angle iron of size 50 x 50 x 6 mm embedded in PCC (1:3:6) type C-2 using 40 mm stone aggregate of upto 1/2 mtr height below GL & 1/2 mtr for above GL. (i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. Contd...17.01/- |
| 18 | (ii) Incoming:-(a) MCCB Fixed TM type with overload short circuit release suitable size and capacity, 400 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 No . (Incoming)(iii) Outgoing:-(a) MCCB Fixed TM type suitable size and capacity, 125 Amp 4 Pole ICU = ICS = 25 KA with overload variation 40-100% - 05 Nos. (outgoing)(b) All as per (a) above but MCCB of Capacity 63 Amps, 4 Pole 25 KA -01 Nos . (outgoing)(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete |
| 19 | Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet duly powder coated with pure polyester based paint on both externally and internally. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands, complete all as specified & directed.Base frame of the panel shall be made of angle iron of size 50 x 50 x 6 mm embedded in PCC (1:3:6) type C-2 using 40 mm stone aggregate of upto 1/2 mtr height below GL & 1/2 mtr for above GL. (i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. Contd...18.01/- |
| 20 | (ii) Incoming:-(a) MCCB Fixed TM type with overload short circuit release suitable size and capacity, 400 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 No . (Incoming)(iii) Outgoing:-(a) MCCB Fixed TM type suitable size and capacity, 200 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos. (outgoing)(b) All as per (a) above but MCCB of Capacity 125 Amps, 4 Pole 25 KA -03 Nos . (outgoing)(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete |
| 21 | Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet duly powder coated with pure polyester based paint on both externally and internally. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands, complete all as specified & directed.Base frame of the panel shall be made of angle iron of size 50 x 50 x 6 mm embedded in PCC (1:3:6) type C-2 using 40 mm stone aggregate of upto 1/2 mtr height below GL & 1/2 mtr for above GL. (i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. Contd...19.01/- |
| 22 | (ii) Incoming:-(a) MCCB Fixed TM type with overload short circuit release suitable size and capacity, 200 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 No . (Incoming)(iii) Outgoing:-(a) MCCB Fixed TM type suitable size and capacity, 125 Amp 4 Pole ICU = ICS = 25 KA with overload variation 40-100% - 03 Nos. (outgoing)(b) All as per (a) above but MCCB of Capacity 63 Amps, 4 Pole 25 KA -01 Nos. (outgoing)(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CT's 200/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete |
| 23 | Supply , installation, testing and commissioning factory made LT bus bar panel board cubical, out door type, floor mounted double door, 3 phasse 4 wire, 50 cycles, 415 volts IP- 65 the panel board shall be made of 3.15 mm thick CRCA sheet for load bearing members shall be powder coated both side.Base frame of the panel shall be made of ICMC channel of size 50x50x6 mm, duly grouted on PCC plareform of size (0.8mx0.8m) made of brick work in CM (1:4), including 15 mm thick plastering in CM (1:6) having minimum height of 600mm including digital type ampere meter (0-400 Amp) and volt meter(0-500 volts). The panel board shall be ssuitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following :-(i) Epoxy insulated 200 Amps rated high conductivity aluminium bas bar including aluminium lugs to conect the cable.(ii) MCCB 4 Pole, 415 V, Fixed TM type, 125 Amps with breaking capacity 25 KA-01 No (For main Incomming) |
| 24 | Earthing complete with galvanized mild steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below ground level connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 50 mm bore medium grade galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50 mm bore light grade galvanized iron protection pipe for earth strip 32 x 6 mm upto 7.5 m length, charcoal, common salt, complete all as shown in EP No 1 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion, complete all as specified and directed. |
| 25 | Material and labour for galvanised iron pipe light grade (ISI marked) 80 mm bore for passing of cables etc. laid in trenches, under floors, roads or fixed to walls including all fittings as required and MS clamps nuts & bolts etc complete all as specified and directed. |
| 26 | Material and labour for galvanised iron pipe light grade (ISI marked) 40 mm bore for passing of cables etc. laid in trenches, under floors, roads or fixed to walls including all fittings as required and MS clamps nuts & bolts etc complete all as specified and directed. |
| 27 | Material & labour for boring holes under road suitable for laying upto 100mm bore pipe for crossing cable not less than one metre below ground level, including getting out,disposal rubbish off to a distance upto 50 meter after making good road with same material to match with existing surface, complete all as specified and as directed. |
| 28 | Supply, Installation and Fixing LT Cable junction box shall be made out of Thermoplastic Polycarbonate and size should be not less than 200mm x 160mm x 98 mm(upto Cable Size 16/25sq.mm). The Polycarbonate JB shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive,IP 65 in accordance with IEC 60529,Weatherproof UV-resistant, rainwater-proof, temperature-resistant. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and MCB of 6 amp and complete all accessories. Complete all as specified and directed. |
| 29 | Supply & fixing 1.5 sqmm, 3 core PVC insulated and FR PVC round sheathed copper conductor flexible cable, 1100 volts grade for connection from Junction Box to street light fittings complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender