Tender For 8736 : Repairs/Replacement To Certain Parts Of Cooling Appliances Split/Window Type Air Conditioners, Water Cooler, Refrigerators And Deep Freezers At Drdl Kalinga Under Age (I) R&D Nstl Visakhapatnam
Tender Value
9.90 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
20 days left
EMD
19800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 8736 : Repairs/Replacement To Certain Parts Of Cooling Appliances Split/Window Type Air Conditioners, Water Cooler, Refrigerators And Deep Freezers At Drdl Kalinga Under Age (I) R&D Nstl Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for periodical servicing including chemical cleaning of condenser tubes and cooling coils by cleaning with fresh water here after spraying with diluted caustic soda solution to remove complete scale for window Acs/Split Acs of any capacity all as directed by Engr-in-charge.(Note: The rates deemed to be included of ACs on high rise buildings upto 6 floors) |
| 2 | Material and labour for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas (R-22) and commissioning and testing the split / window type air conditioner unit 1.5/2.0 Ton capacity complete all as specified and directed. |
| 3 | Material and labour for taking out split / window type Air conditioner 1.0/1.5/2.0Ton capacity of any make from its original location & shifting of AC from existing location to new location complete installation and testing including making good of old location all as specified and directed |
| 4 | Supply only sealed compressor unit working on 230 Volts AC supply suitable for 2 TR window/ split type AC of any make/ model. [Make: Carrier/ Hitachi/ Tekumseh/ Usha/ Voltas/ Blue Star or equivalent] |
| 5 | Supply only sealed compressor unit working on 230 Volts AC supply suitable for 1.5 TR window/ split type AC of any make/ model. [Make: Carrier/ Hitachi/ Tekumseh/ Usha/ Voltas/ Blue Star or equivalent] |
| 6 | Supply only suction valve of size 5/8\\" as required |
| 7 | Supply only discharge valve of size 1/4\\" as required |
| 8 | Supply only blower motor double shaft, single/double speed, single phase, AC 230 V of 1/6 to 1/4 HP capacity to suit the existing window type AC all as directed. [Make: As per OEM] |
| 9 | Supply only blower motor single shaft, single/double speed, single phase, AC, 230 V of 1/8 to 1/5 HP capacity to suit the out door unit of split type AC all as directed. [Make: As per OEM] |
| 10 | Supply only blower motor single shaft, single/double speed, single phase, AC, 230 V suitable for indoor unit of split type AC of 1.5/ 2.0 TR capacity all as directed. [Make: As per OEM] |
| 11 | Supply only fan blade set suitable for window/ split type AC of any capacity. |
| 12 | Supply only remote control complete suitable for existing model of split type AC of any capacity. [Make: As per OEM] |
| 13 | Supply only fan motor capacitor of 2 mfd capacity[Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron or equivalent] |
| 14 | Supply only fan motor capacitor of 3 mfd capacity[Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron or equivalent] |
| 15 | Supply only fan motor capacitor of 4 mfd capacity[Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron or equivalent] |
| 16 | Supply only fan motor capacitor of 6 mfd capacity[Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron or equivalent] |
| 17 | Supply only compressor capacitor of 50 + 2 mfd capacity[Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron or equivalent] |
| 18 | Supply only compressor capacitor of 50 + 6 mfd capacity[Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron or equivalent] |
| 19 | Supply only fan blade set suitable for water cooler of any capacity. |
| 20 | Supply only PVC insulated flexible cable 3 core 2.5 sq.mm size copper conductor. |
| 21 | Supply only PVC insulated flexible communication cable for indoor to outdoor unit 4 core 2.5 sq.mm size copper conductor. |
| 22 | Supply only 15mm dia PVC flexible pipe complete for water cooler of any capacity. |
| 23 | Supply only Refrigerant gas 'R- 22' in manufacturer's sealed cylinder.[Make: Floron/ Mafron/ Retron or equivalent] [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.] |
| 24 | Supply only Refrigerant gas 'R- 32' in manufacturer's sealed cylinder.[Make: Floron/ Mafron/ Retron or equivalent] [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.] |
| 25 | Supply only Nitrogen gas in manufacturer's sealed cylinder for leak testing. [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.] |
| 26 | Supply & fixing set of MS mounting brackets for 1.5/ 2.0 TR AC Outdoor unit, heavy duty including necessary expansion fasteners. |
| 27 | Supply only indoor and outdoor for PCBs of indoor/ outdoor unit of split type AC of any make/ capacity complete all as directed. |
| 28 | Supply only PVC flexible pipe for condensed water drain fitted with clamps/concealed suitable for window/Split type Acs in wall/roof complete all as specified and directed. |
| 29 | Supply and fixing single pole MCB 20 Amps 240V 10 KA 'C' curve complete all as specified and directed. |
| 30 | S&F of Split AC 1.5 ton 5 star/existing rating indoor unit with necessary remote complete incl taking down old unserviceable and deposited to E/M store. All as specified and directed by Engr-in-Charge |
| 31 | S&F of Split AC 2.0 ton 5 star/existing rating indoor unit with necessary remote complete incl taking down old unserviceable and deposited to E/M store. All as specified and directed by Engr-in-Charge |
| 32 | S&F of Split AC 1.5 ton outdoor unit with necessary fixing arrangements complete incl taking down old unserviceable and deposited to E/M store. All as specified and directed by Engr-in-Charge |
| 33 | S&F of Split AC 2.0 ton outdoor unit with necessary fixing arrangements complete incl taking down old unserviceable and deposited to E/M store. All as specified and directed by Engr-in-Charge |
| 34 | Supply and fixing copper pipe suitable for suction line AC indoor/ Out door including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and directed. Note:- 01 Meter of 1/2''copper pipe,01 Meter of 1/4'' dia copper pipe, Clamps fixing for copper coil 01 Meter PVC corrugated pipe shall be measured as one unit length. |
| 35 | Supply and fixing copper pipe suitable for discharge line AC indoor/ Out door including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and directed. Note:- 01 Meter of 1/2''copper pipe,01 Meter of 1/4'' dia copper pipe, Clamps fixing for copper coil 01 Meter PVC corrugated pipe shall be measured as one unit length. |
| 36 | Supply only Spring Tube Bender 5/8\\" inch Inside Bender (16mm) complete all as specified and directed |
| 37 | Supply only Spring Tube Bender 1/2\\" inch Inside Bender (16mm) complete all as specified and directed |
| 38 | Supply only fare nuts of size 5/8'' made out of brass complete all as specified and directed. |
| 39 | Supply only 5/8''X1/4'' dia tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC all as specified and directed. Note:- 01 Meter of 5/8''internal dia ,01 Meter of 1/4'' internal dia shall be measured as one unit length. |
| 40 | Supply and Valve dummy caps made up of Brass of size 5/8\\" |
| 41 | Supply and Valve dummy caps made up of Brass of size 1/2\\" |
| 42 | Supply only PVC Pipe of 50 mm dia of density 6kg/mtr for fixing between indoor and out door units inside the walls of appropriate lengths and closing the balance holes with PCC/Birla white/Glass putty and making the surface finishes even as directed by the engineer in charge |
| 43 | S&F PVC drain pipe 40mm and complete all as specified and directed. |
| 44 | S&F PVC drain pipe 25mm and complete all as specified and directed. |
| 45 | Supply only sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts all as specified. [Make: Legrand/ Standard/ L&T or equivalent] |
| 46 | Supply only metal plug top 15 Amps. [Make: Anchor/ Cona/ GM or equivalent] |
| 47 | Remove of u/s stabilizer and refix with new voltage stabilizer for 1.5/2.0 Ton split type AC all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender