Tender For special Repair / Replacement Of Refrigerator, Water Cooler, Deep Freezer, Voltage Stabilizer Against Ber And special Repair / Replacement Of Air Conditioning Against Ber Under Ge (East) Ferozepur Cantt
Tender Value
47.62 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
20 days left
EMD
95240
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair / Replacement Of Refrigerator, Water Cooler, Deep Freezer, Voltage Stabilizer Against Ber And special Repair / Replacement Of Air Conditioning Against Ber Under Ge (East) Ferozepur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fix refrigerator, electric driven (single phase), capacity of/300/ 310/320 Litres. BEE 5 star rated, complete all as specified and directed. |
| 2 | Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour, complete all as specified and directed. |
| 3 | Supply and fix water cooler electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour, complete all as specified and directed. |
| 4 | Deep freezer hard top up to 320 litre capacity having single door, complete all as specified and directed. |
| 5 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0 .5 KVA, complete all as specified and directed. |
| 6 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA, complete all as specified and directed. |
| 7 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. |
| 8 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA, complete all as specified and directed. |
| 9 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. |
| 10 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. |
| 11 | Supply and fixng Sheet metal enclosure with socket plug Top and MCBs single pole and neutral enclosure with a two pin and eath plug socket complete with one single pole MCB of 20 Amp 'B Series capacity including fastners, bolts, washers. and making good the disturbed surfaces to match with the existing surface, complete all as specified and directed. |
| 12 | Supply and fixing sub main wiring two Run of 4 sqmm single core PVC FRLS insulated, unsheathed multistranded copper conductor cable 1100 voll grade, drawn through and including PVC conduit medium duty including accessaries of 25mm size and fixed with PVC sadles and cadmium plated steel screws to the surfaces of the wall/ceiling including one run of 4 sqmm single core PVC FRLS insulated unsheathed copper eath continulty conductor complete all as specified and as directed. Notes:1. Two runs of single core cable with one run of earth continuty conducto including PVC conduit and accessories shall be measured and paid as one unit.2. The rate quotes against this item is deemed to be inclusive of making good the distrubed sufaces to match with the existing surfaces. |
| 13 | Supply and install hi wall spilt unites indoor/outdoor inverted type complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating, capacity 2 TR, complete all as specified and directed.. |
| 14 | Supply and install hi wall spilt unites indoor/outdoor inverted type complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating 1.5 TR, complete all as specified and directed. |
| 15 | Supply and install hi wall spilt unites indoor/outdoor inverted type complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and capacity 1.5 TR and with cooling and heating function, complete all as specified and directed. |
| 16 | Supply and install stand for AC outdoor unit, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender