Tender for Special Repair To Lt Overhead To Underground Cable At 222 Asc Bn Under Ge (Utilities) Udh Ur
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Special Repair to LT Overhead to underground cable at 222 ASC Bn under GE (Utilities) Udhampur Contract No: GE/U-104/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling of existing GI earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and directed by Engr-in-Charge. |
| 3 | Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolation of concrete excavation and earth work as reqd and removing the same from site complete all as specified and directed by Engr-in-Charge. |
| 4 | Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from site complete all as specified and directed by Engr-in-Charge. |
| 5 | Dismantling of old UNSV damage/rusted PCC pole/steel tubular poles of any size necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed by Engr-in-Charge. |
| 6 | Dismantling of insulator of any type and size from existing poles after opening nuts, bolts and removing from site complete all as specified and directed by Engr-in-Charge. |
| 7 | Dismantling of cross arms fixed on steel tubular poles carefully and removing from site complete all as specified and directed by Engr-in-Charge. |
| 8 | Supply and fixing of steel tubular swaged poles with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete incl making five alternative strips 30 cm wide in different colour above ground level or plinth level incl marking of MES pole No in black paint complete with cast iron base plate, final tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00 mtr long) complete all as specified.and directed by Engr-in -charge. |
| 9 | M&L for cement concreate 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specified and directed by Engr-in-Charge. |
| 11 | S&F in replacement Stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod including taking down old old unservicable same complete all as specefied and directed by Engr-in-charge.. |
| 12 | Supply and lay and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with stranded aluminium conductor 1100 volts grade of following size :-complete all as specefied and directed by Engr-in-charge.. |
| 13 | (a) 400 Sqmm 3.5 core cable |
| 14 | (b) 240 Sqmm 3.5 core cable |
| 15 | (c 185 Sqmm 3.5 core cable |
| 16 | (d 95 Sqmm 3.5 core cable |
| 17 | (e) 70 Sqmm, 3.5 core cable |
| 18 | (f) 50 Sqmm, 3.5 core cable |
| 19 | (g) 25 Sqmm, 4 core cable |
| 20 | (h) 10 Sqmm, 4 core cable |
| 21 | (j) 16 Sqmm, 4 core cable |
| 22 | Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and as directed by engineer in charge. |
| 23 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge. |
| 24 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge. |
| 25 | Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge. |
| 26 | S&F double walled corrugated (DWC) pipe of size 180 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT/HT cable in trench/under ground complete all as spd and directed by Engineer - in-charge. |
| 27 | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed. |
| 28 | S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed. |
| 29 | S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as spd and directed by Engineer-in-charge. |
| 30 | Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe, complete all as specified and directed by Engineer-in-Charge. |
| 31 | All as per item No.20 here in before but size 50 mm bore. |
| 32 | All as per item No.20 here in before but size 40 mm bore. |
| 33 | Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed conduit wiring, etc and making good, cutting exceeding 10 cm but not exceeding 20 cm girth. |
| 34 | M&L for cutting/boring the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road complete all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 35 | Taking down existing old street light panel /feeder box/LT panel of any type and size and capaacity comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed by Engr-in-Charge. |
| 36 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands. (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables, Panel to be fixed at 450mm above Natural Ground Level on Brick Masonry Platform including Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick around the Area upto 1.50 Metre in all directions from the Panel all as ordered including Provision of Cattle Fencing with Open-able Gate (1.20 Metre to 1.50 Metre in Height) around the Area upto 1.50 Metre, complete all as specified and as directed by Engr-in-Charge. |
| 37 | (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. :- INCOMING(a) MCCB four pole 400 Amps, 36 KA at 415 Volts (Make:Havell's Cat (b) 800 Amps rated Aluminium bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils (f) Changeover Switch -320 A, 4 pole-01 Nos OUT GOING(a) MCCB four pole 250 Amps, 36 KA at 415 Volts-01 No(b) MCCB four pole 200 Amps, 25 KA at 415 Volts-01 No(c) MCCB four pole 63 Amps, 25 KA at 415 Volts-01 No |
| 38 | All as above items No 26 - above but following capacity for INCOMING(a) MCCB four pole 250 Amps, 36 KA at 415 Volts- 01 No.(b) 500 Amps rated Aluminium bus bar suitable for 3 phase 4 wire system - 01 No.(c) Phase indicating lamp RYB neon type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with selector switch.(e) Ammeter Digital type 0-200 Amp capacity with selector switch and CT coils OUT GOING(a) MCCB four pole 160 Amps, 25 KA at 415 Volts-01 No(b) MCCB four pole 100 Amps, 25 KA at 415 Volts-01 No(c) MCCB four pole 63Amps, 25 KA at 415 Volts-01 No |
| 39 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion including earth pit chamber board of 3.15 mm thick mild steel sheet sheet of size min 45cmx30cm fixed with 12 mm thick MS rod two nos upto 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letter min 6 cm height i.e Earth pit No . Location Earthing test value and date and other letters complete all as directed by Engr-in-Charge. |
| 40 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth wire 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. |
| 41 | Dismantling of existing street light fitting of any size/type complete with bracket including necessary electrical connection complete all as specified and directed by Engr-in-Charge |
| 42 | S&F 45 Watt LED street light new generation energy saving and envoirenment friendly (suitable for fixing on 40 mm dia MS pipe) with pressure die cast aluminium housing & toughened glass with high efficency LEDs as lightibg source , IP-66 degree protection and impact resistance of IK08, individual LED's must have peanut lenses and lens embeded PC cover with top opening seperate driver compartment for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specefied and directed by Engr-in-charge. |
| 43 | Supply and fixing non transparent looping SMC kiosks pole box 3 phase of size 310×210×120 mm made out of engineering plastic one piece moulding siemens gray colour with hold fast including 4 Nos aluminium strips 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one, complete all as specified directed by Engineer- in -charge. |
| 44 | S & F rigid non metallic PVC conduit of size 25 mm dia exclusive of boxed (junction/terminal) but inclusive of all tee, bends, elbows, reucers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified directed by Engineer- in -charge. |
| 45 | S & F PVC insulated and sheathed 2.5 sq mm two core stranded, aluminium conductor cable from junction box/OH line to street light fitting or for engagement lights complete all specified & directed by Engr-in-Charge. |
| 46 | Supply and fixing street light bracket made out of 40 mm light grade GI tubing minimum 1.5 Mtr long with with suitable adapter to suit the opening of street light on one end alongwith integrated fabricated adapter round cup type with 02 Nos studs on outer side to fix the braket on top of existing steel tubular pole two way, with necessary MS clamps with one coat of red oxide and two coats of alluminium paint upon fabricated adapter including nut, bolts, washers complete all as specified and directed by Engr-in-Charge. |
| 47 | Supply, install, 200 amp Aluminium Bus bar with double door enclouser dully flush in wall/wall mounted/pole mounted size 400 mmX400 mmx 100 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement complete including making good the disturbed surface complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender