Power Boards / Undertakings / PSU Closing in 3 days TDR #57955446

Tender For Shifting Ksebl Utilities From Valavetty Bab To Maruthinakam Bab For Vazhayila-Pazhakutty Road Improvement Work (Krfb) Under Electrical Section, Vellanad

Issued by Boards / Undertakings / PSU · Thiruvananthapuram, Kerala
Tender Value
21 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
3 days left
EMD
50000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Shifting Ksebl Utilities From Valavetty Bab To Maruthinakam Bab For Vazhayila-Pazhakutty Road Improvement Work (Krfb) Under Electrical Section, Vellanad

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Oct-2026 Date Corrigendum Date 30-Oct-2026
2 31-Oct-2026 Date extension Date 07-Nov-2026

BOQ

Name of Work:- SHIFTING KSEBL UTILITIES FROM VALAVETTY BAB TO MARUTHINAKAM BAB FOR VAZHAYILA-PAZHAKUTTY ROAD IMPROVEMENT WORK (KRFB) under Electrical Section, Vellanad
Sl. No. Item Description
1Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
2Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle).
3Labour charges for loading LT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
4Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges.
5Transporting Transformers by hired vehicle to a distance upto 5km and carrying upto 2 numbers of 63/100/160/250kVATransformers / Ring Main Units excluding loading& unloading charges.
6Dismantling (without damage) one 11kV PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same
7Dismantling (without damage) one 11kV A type pole after disconnecting stays, strut etc. attached thereon and stacking the same.
8Dismantling (without damage) one HT TW/RSJ/Rail Strut pole including removal of clamps and stacking.
9Dismantling (without damage) one HT PSC/RCC Strut pole including removal of clamps and stacking.
10Dismantling (without damage) one km 11kV line (three conductors) including dismantling cross arm, insulators, disc, disconnecting jumper connection, rolling the conductor and stacking the materials.
11Dismantling (without damage) one HT stay including digging pit in all classes of soil and backfilling, and bringing back to section store.
12Dismantling (without damage) one Channel cross arm from existing DP structure and bringing back to section store.
13Dismantling (without damage) one AB switch from existing structure and bringing back to section store.
14Dismantling transformer station with transformer erected in DP structure by dismantling HT Double Pole Structure using PSC pole after disconnecting stay wires, 10 channel cross arms,AB switch, DO fuse, LA, GI earthing leads, DTR meter with box with metering equipments, CTs, Distribution Box, statutory display boards etc. but excluding the rate of dismantling transformer, earthing, stay sets & fencing.
15Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole.
16Drilling oval shaped hole of various sizes on existing Channel/Cross Arm/GI/MS cleat etc.
17Fitting and erecting one HT PSC Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
18Fitting and erecting one HT A type Single Pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing sufficient length of GI earthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing).
19Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point.
20Fitting and erecting one HT Double Pole Structure using A type pole in position including fitting 2 No. channel cross arm, digging and back filling pit in ordinary soil, drawing sufficient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing).
21Fitting and providing one HT Stay for 11kV pole, including digging and back filling pit in ordinary soil.
22Fitting and providing one Strut using HT PSC pole including digging and back filling pit in ordinary soil.
23Stringing of one km 11kV line with ACSR Raccoon (3 conductors) after fitting insulators and giving jumper connections including cutting and removing tree branches wherever necessary excluding cut point works
24Fitting 6 channel cross arms, AB switch, DO fuse, Station class LA, HT & LT connections upto OH lines, etc. on existing DP structure, Fixing distribution box/provision for one set (3No.) of LT fuses, drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing & mounting of Transformer on poles.
25Erecting one 100kVA Transformer to existing DP and giving connections, including loading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer.
26Erecting one 160kVA Transformer to existing DP and giving connections, including loading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer.
27Fitting one additional Fuse unit and giving connection from Transformer to fuse and Distribution box to LT OH line.
28Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling.
29Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling.
30Fitting one set AB switch on existing DP, giving connection and drawing sufficient length of GI earthing leads to the ground for earthing, excluding provision of earthing.
31Fitting one Additional V cross arm in existing single pole including conveyance of materials.
32Fitting one Additional 75x40mm, 1.8m Channel cross arm in existing single pole including conveyance of materials.
33Fitting one Additional2.4/3m Channel cross arm (75x40x6mm), in existing 11kV DP including conveyance of materials.
34Fitting one LT 4 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT Line.
35Additional rate for providing one HT Pin with insulator, complete on any type of HT pole.
36Additional rate for providing one F top bracket complete, on any type of HT pole.
37Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, strut etc. attached thereon and stacking the same.
38Dismantling (without damage) LT stay including digging pit in all classes of soil and backfilling.
39Dismantling (without damage) one km LT single phase 2 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
40Dismantling (without damage) one km LT three phase 4 wire OH line conductor by dismantling cross arms, insulators and stacking the conductors in rolls properly.
41Dismantling (without damage) one km LT additional conductor line by dismantling cross arms,insulators and stacking the conductors in rolls properly.
42Dismantling one section fuse from structure and bringing back to section store.
43Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
44Disconnecting and lowering down the three phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work.
45Erecting one LT PSC Pole in position including digging & back filling pit in ordinary soil.
46Providing Stay for LT poles including digging & back filling pit in ordinary soil.
47Providing Strut using LT PSC pole including digging and back filling pit in ordinary soil.
48Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase & Neutral and ACSR Weasel for street main, for one km LT single phase 3 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.
49Stringing, shackling, fitting cross arms, insulators and binding, giving jumper connection etc. using ACSR Rabbit for Phase and ACSR Weasel for Neutral & Street Main, for one km LT 3ph 5 wire line including cutting and removing tree branches wherever necessary and conveyance of all materials (except poles) from stacking place.
50Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc.
51Providing WP support with PSC pole including digging & back filling pit in ordinary soil. excluding transportation of poles.
52Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
53Dismantling one 2x40W fluorescent tube fitting from the existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
54Dismantling one Transformer (upto and including 160kVA) from existing structure and loading to any vehicle directly, including disconnecting HT/LT/Earth connections.
55Providing/Inserting 2 line spacer on the existing LT OH line.
56Providing/Inserting 3 line spacer on the existing LT OH line.
57Renewal of existing damaged/broken old 11kV Stay to the existing stay rod.
58Renewal of existing damaged/broken old LT stay in existing stay rod.
59Additional rate for refitting/redoing one Shackle Set, including reshacling one span, while renewing any type of LT pole.
60Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc.
61Brick work in cement mortar 1:4 with country burnt bricks for superstructure as per the direction of departmental staff
62Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizondal brasing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation
63Pole numbering using printed Aluminium sheets of 22 SWG having size 20 x 12 cm or Painting the surface of line supports where numbers are to be inscribed, Pole numbers shall be painted in circular / rectangular background, using approved quality anti algal yellow paint in two coat after scraping and cleaning the surface at a height of 2.5 metre above ground level.The number and letters should be in black synthetic enamel paint. The size of the number should be at least 2cm in height x 1.5cm in width. including cost of paint.
64Providing concrete muffing of size 0.45x0. 45x1.5m (0.5m above GL and 1m below GL). Excavation 0.45x0.45x1m, concrete (1:3:6, 20mm)0.45x0.45x1.5m, Plastering (1:3) 12mm0.45x0.45mx5sides. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57955446
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 21 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Kerala State Electricity Board
Work Description Tender for Shifting Ksebl Utilities From Valavetty Bab To Maruthinakam Bab For Vazhayila-Pazhakutty Road Improvement Work (Krfb) Under Electrical Section, Vellanad
Basic Detail
Tender No 01/AEE/ESD/PYD/2026-27/ 09.10.2026
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 31 Oct 2026
Submission Date 07 Nov 2026
Open Date 11 Nov 2026
Finance
Tender Value 21 Lakhs
Tender Fee 5900
EMD 50000
Exemption Not Available
Document List
21978791-4450-4208-983e-b229fe8b8710.html
BIDvld.pdf
BOQ_1492438.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 07, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

21978791-4450-4208-983e-b229fe8b8710.html

pdf

BIDvld.pdf

xls

BOQ_1492438.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender