Road Transport and Highways Local Bodies Closing in 2 days TDR #57954939

Tender For Hvac Related Work In Dialysis Maternity, Isolation Ward And Ldr Rooms At Construction Of Critical Care Block Hospital At District Jhunjhunu

Issued by Local Bodies · Jaipur, Rajasthan
Tender Value
42.44 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
2 days left
EMD
84880
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Hvac Related Work In Dialysis Maternity, Isolation Ward And Ldr Rooms At Construction Of Critical Care Block Hospital At District Jhunjhunu

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 Corrigendum to modified dates 15.10.2026 Date 21-Oct-2026

BOQ

Name of Work:- HVAC Related work in Dialysis Maternity, Isolation ward and LDR Rooms at Construction of Critical Care Block Hospital at District JHUNJHUNU
Sl. No. Item Description
11. Air conditioning system
2Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
30.60 mm
40.80mm
5Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All as per pre approved by Engineer in charge.
613mm thick for indoor Application
719mm thick for Outdoor Application with 26 SWG Aluminium Cladding
8Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
9Un Armoured
102 core x 1.5 Sq.mm
11SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
12Supply , Installation, Testing and Comissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
13SITC of Wall mounting cubical type DOL Starter panel for AHU made out of 1.6 mm thick sheet steel powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of Blower motor comprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
14Upto 4000 CFM
15Gas charging of VRF/VRV system with R410A refrigerant gas. Before gas charging system shall be flushed with high purity Nitrogen Gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with Refrigerant Gas. Thereafter System shall be tested with Nitrogen Gas at 1.5 Times of working pressure of R410 Refrigerant Gas to ensure leakproof system. Whole system shall be Vacuumed up to 500-micron level which ensures the zero-moisture content level in piping to ensure better cooling efficiency and long life of the system. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
16Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
17Supply Air Diffuser with Volume Control damper
18Return Air Diffuser without Volume Control damper
19Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
20150mm x 50mm x 1.6mm
21Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
2225mm x 6mm G.I. ( Hot Dipped ) Strip
23Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
248 SWG G.I. ( Hot Dipped ) Wire
25Supply, installation testing, commissioning and validation of Laminar Flow Units (LFU) comprising of Terminal EU 13 HEPA Filters of 99.997% Efficiency down to 0.3 Micron particle size installed in zero leakage Al frame with Al perforated plate type Al grille with Al VCD, LFD laminar flow diffusers are constructed from 18 swg aluminium sheet, perforated face with approx. 50% perforation od size 900x600mm-6nos, 600x600mm-3nos, including the cost of supply air 18 gauge Al plinum of size 8'x6'x1.5'/2', including all connection complete in all respect. Make:- Systemair, Ravistar, MetalJoint, Airmax, Mapro
26LFU Size : 2400 x 1800 mm ( +/- 100mm )
27Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
2816.0 Sq. mm
294 core
3025.0 Sq. mm
313.5 core
3235.0 Sq. mm
333.5 core
34Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
352 x 16.0 sq.mm
362 x 25.0 sq.mm
372 x 35.0 sq.mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57954939
AUTHORITY Local Bodies
TENDER VALUE 42.44 Lakhs
LAST DATE 21-10-2026
Authority
Authority Name Rajasthan State Road Development And Construction Corporation Limited
Work Description Tender for Hvac Related Work In Dialysis Maternity, Isolation Ward And Ldr Rooms At Construction Of Critical Care Block Hospital At District Jhunjhunu
Basic Detail
Tender No NIT No. 419/2026-27 dated 08.10.2026 Sl No 03
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 15 Oct 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 42.44 Lakhs
Tender Fee 590
EMD 84880
Exemption Not Available
Document List
97080081-8049-4a97-9ba8-2af5810e7671.html
agrement.pdf
AnnexureABCD_RTPPAct2012_AnnexureC.pdf
AnnxAPWDELECTBSR2022.pdf
BOQ_1070296.xls
EligibilitycriteriaofBidd_1.pdf
Engineering_Cost.pdf
gen-tc-dlp-tc-HVACCCBHospJhunjhunu.pdf
PdBankAccountNumberDetails.pdf
Tendernotice_1.pdf
various_Circulars_orders.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

97080081-8049-4a97-9ba8-2af5810e7671.html

pdf

agrement.pdf

pdf

AnnexureABCD_RTPPAct2012_AnnexureC.pdf

pdf

AnnxAPWDELECTBSR2022.pdf

xls

BOQ_1070296.xls

pdf

EligibilitycriteriaofBidd_1.pdf

pdf

Engineering_Cost.pdf

pdf

gen-tc-dlp-tc-HVACCCBHospJhunjhunu.pdf

pdf

PdBankAccountNumberDetails.pdf

pdf

Tendernotice_1.pdf

pdf

various_Circulars_orders.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender