Power Government Departments Closing in 1 days TDR #57954915

Tender For Electrification Of Additional Un-Electrified Households In The State Of Assam Under Rev Ed Reforms Linked Results Based Distribution Sector Scheme (Rdss, Addl. Hh) For Additional Package Of Goalpara District

Issued by Government Departments · Goalpara, Assam
Tender Value
14.22 Crore
Estimated cost
Bid Submission
29 Oct 2026
1 days left
EMD
28.45 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Goalpara → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrification Of Additional Un-Electrified Households In The State Of Assam Under Rev Ed Reforms Linked Results Based Distribution Sector Scheme (Rdss, Addl. Hh) For Additional Package Of Goalpara District

BOQ

Name of Work:- Electrification of additional un-electrified households in the State of Assam under Rev ed Reforms Linked Results Based Distribution Sector Scheme (RDSS, Addl. HH) for additional Package of Goalpara District
Sl. No. Item Description
1Please Enable Macros to View BoQ information
2Construction of new 11 kV line along with installation of 25,63 kVA DTR and new LT lines on single and three phase AB cable for electrification of Un electrified household as per technical specifications, scope of works and approved drawings :
3Total Amount of Supply Price
4Total Amount of Installation/Erection charges
5Total of complete work
6Discount if any Offered by Bidder in %
7Construction of new 11 kV line along with installation of 25,63 kVA DTR and new LT lines on single and three phase AB cable for electrification of Un electrified household as per technical specifications, scope of works and approved drawings under:
8Goalpara District
9Construction of 38.2 Ckm, 11 kV Line on ACSR Rabbit conductor using 8.5 M P.S.C poles as per technical Specification, scope of works and approved drawings
10Supply & erection of PSC Pole 8.5 Mtr. (550kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm/ M10 Concreting at base
11Supply and fitting of 11 KV 'T' Cross Arm (GI) with angle size 50x50x6mm as per TS
12Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm
13Supply, fitting & fixing of Galvanized Channel (100x50x6X2200) mm for height rising
14Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
15Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C)
16Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR
17Supply ,Stringing, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor
18Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS
19Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS
20Supply, Fixing and Fitting of GI Stay wire 7/10 SWG
21Supply fitting and fixing of Galvanized Angle Cross Arm (50x50x6) mm for Cross Bracing for DP/TPs/FPs, as per T.S.
22Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
23Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
24Supply, Fitting and Fixing of Jointing Sleeve for Rabbit ACSR
25Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
26Supply and fixing of AI. Bi-metallic Binding Wire (10 SWG.)
27Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6) mm
28Supply , fitting & fixing of Fish Plate ( 50x6) mm
29Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A)
30Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick)
31Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
32Grouting of poles with M-10 Concreting as per TS
33Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager
34Line Crossing - Line to line / Road:
35Supply, fitting & fixing of Galvanized Angle Cross Arm (50x50x6X2500) mm for Guarding
36Supply, Fixing and Fitting of GI wire 8 SWG for Guarding as per T.S
37Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
38Supply, fitting and Fixing of I Hook GI as per TS
39Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
4011 KV DO Fuse 150A (For tapping points):
41Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three)
42Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
43Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm
44Supply, fitting & fixing of Galvanized Channel Cross Arm (100x50x6X2200) mm
45Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
46Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6) mm
47Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
48Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
49Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
50Construction of 38.9 Ckm new three phase LT lines on AB XLPE cable using 7.5 Mtr PSC poles as per technical specifications, scope of works and approved drawings
51Supply & erection of PSC Pole 7.5 Mtr. (350kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm / M10 Concreting at base upto 75 mm from bottom
52Supply ,Stringing ,fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (3C x 50 sqmm + 1Cx35 sqmm)
53Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables.
54Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for 7.5 mtr. PSC Pole
55Supply, Fixing and Fitting of GI I-Hook
56Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard
57Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard
58Supply fitting & fixing of Cable end caps for ABC cables
59Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB.
60Supply, fitting & fixing of ASA distribution box (with pre fitted lug for service connection) for 3-phase, 250 Amps busbars, for 1 no. 3-phase input and 9 no. 3-phase outputs with 1.5 mtr. 4C x 25 Sq. mm PVC cable (Al conductor) for charging DB
61Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long)
62Supply fitting & fixing Buckles for Steel Straps for DB fixing
63Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP50 for DB Charging as per NFC Std.
64Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std.
65Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std.
66Supply, Erection,fitting & fixing of LT Stay Set as per TS
67Supply, Fitting and Fixing of LT Guy Insulator Porcelain as per TS
68Supply, Fixing and Fitting of GI Stay wire 7/14 SWG
69Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification
70Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
71Supply Fitting and Fixing of LT Danger Plate (1.6mm thick)
72Supply, fitting & fixing of Galvanized Channel (100x50x6X2200) mm for height rising
73Grouting of poles with M-10 Concreting as per TS
74Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager
75Construction of 68.7 Ckm new single phase LT lines on AB XLPE cable using 7.5 Mtr PSC poles as per technical specifications, scope of works and approved drawings
76Supply & erection of PSC Pole 7.5 Mtr. (350kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm / M10 Concreting at base upto 75 mm from bottom
77Supply ,Stringing ,fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (1C x 35 sqmm + 1Cx25 sqmm)
78Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables.
79Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for 7.5 mtr. PSC Pole
80Supply, Fixing and Fitting of GI I-Hook
81Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard
82Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard
83Supply fitting & fixing of Cable end caps for ABC cables
84Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB.
85Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long)
86Supply fitting & fixing Buckles for Steel Straps for DB fixing
87Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std.
88Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP25 for DB Charging as per NFC Std.
89Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std.
90Supply, Erection,fitting & fixing of LT Stay Set as per TS
91Supply, fitting & fixing of LT Guy Insulator Porcelain
92Supply, Fixing and Fitting of GI Stay wire 7/14 SWG
93Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification
94Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
95Supply Fitting and Fixing of LT Danger Plate (1.6mm thick)
96Supply, fitting & fixing of Galvanized Channel (100x50x6X2200) mm for height rising
97Grouting of poles with M-10 Concreting as per TS
98Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager
99Construction of 70 Nos of 63 KVA DTR Substation using 8.5 Mtr PSC pole, as per technical specifications, scope of works and approved drawings
100Supply & erection of PSC Pole 8.5 Mtr. (550kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm/ M10 Concreting at base
101Supply, fitting & installation of 3-phase, 4 star, BIS Level - II, aluminium wound distribution transformer, 11/0.433 kV, 63 kVA, with bi-metallic terminal connectors at both HT & LV side
102Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm ( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.)
103Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp
104Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
105Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
106Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three)
107Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three)
108Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS
109Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS
110Supply, Fixing and Fitting of GI Stay wire 7/10 SWG
111Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
112Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing
113Supply ,fitting & fixing of DTR Cubicle for 63 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc)
114Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of DTR Cubical etc.
115Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
116Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C)
117Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR
118Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick)
119Supply ,Stringing, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor
120Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
121Supply, stringing, testing & Commissioning of XLPE Cable 1-Core 95 sq. mm unarmoured (Aluminium)
122Supply fitting & fixing of Bi-metallic Lug 50 sq.mm.
123Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A)
124Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work
125Grouting of poles with M-10 Concreting as per TS
126Supply fitting & fixing of 11 kV Gang Operated AB Switch:
127Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A
128Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm(2 no for AB Swtich, 1 no. for Handle fixing)
129Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
130Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
131Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch
132Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
133Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
134Supply, fitting and Fixing of I Hook GI as per TS
135Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel)
136Sign Board installation inclusive of supply, installation and painting as per TS
137Construction of 14 Nos of 25 KVA DTR Substation using 8.5 Mtr PSC pole, as per technical specifications, scope of works and approved drawings
138Supply & erection of PSC Pole 8.5 Mtr. (550kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm/ M10 Concreting at base
139Supply, fitting & installation of 3-phase, (4 star, BIS Level-II), Aluminium wound distribution transformer, 11/0.433 kV, 25 kVA, with bi-metallic terminal connectors at both LV and HV side
140Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm ( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.)
141Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp
142Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
143Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
144Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three)
145Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three)
146Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS
147Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS
148Supply, Fixing and Fitting of GI Stay wire 7/10 SWG
149Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
150Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing
151Supply fitting & fixing of DTR Cubicle for 25 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc)
152Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of main switch meter box etc.
153Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
154Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C)
155Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR
156Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick)
157Supply ,Stinging, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor
158Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
159Supply, stringing, testing & Commissioning of XLPE Cable 1-Core 50 sq. mm unarmoured (Aluminium)
160Supply fitting & fixing of Bi-metallic Lug 50 sq.mm.
161Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A)
162Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work
163Grouting of poles with M-10 Concreting as per TS
164Supply fitting & fixing of 11 kV Gang Operated AB Switch:
165Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A
166Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm
167Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
168Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
169Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch
170Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
171Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
172Supply, fitting and Fixing of I Hook GI as per TS
173Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel)
174Sign Board installation inclusive of supply, installation and painting as per TS
175Construction of 0 Ckm of 11 kV Line on ACSR Rabbit conductor using SP-56 poles as per technical Specification, scope of works and approved drawings
176Supply, erection,Fixing and Fitting of GI Steel Tubular Pole SP-56 as per T.S, IS and approved GTP
177Supply , fitting & fixing of G I Channel Section 75x40x6x1100 mm and 75x40x6x350 mm GI top cleat for fixing of 11 KV polymeric Pin insulator
178Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm
179Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
180Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C)
181Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR
182Supply ,Stringing, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor
183Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS
184Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS
185Supply, Fixing and Fitting of GI Stay wire 7/10 SWG
186Supply fitting and fixing of Galvanized Angle Cross Arm (50x50x6) mm for Cross Bracing for DP/TPs/FPs, as per T.S.
187Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
188Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
189Supply, Fitting and Fixing of Jointing Sleeve for Rabbit ACSR
190Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
191Supply and fixing of AI. Bi-metallic Binding Wire (10 SWG.)
192Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp
193Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A)
194Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick)
195Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
196Grouting & muffering of steel tubular poles with M-10 Concreting as per TS
197Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager
198Line Crossing - Line to line / Road:
199Supply, fitting & fixing of Galvanized Angle Cross Arm (50x50x6X2500) mm for Guarding
200Supply, Fixing and Fitting of GI wire 8 SWG for cross lacing as per T.S
201Supply, Fixing and Fitting of GI wire 6 SWG for Earthing & Guarding with GI Nut and Bolts
202Supply, fitting and Fixing of I Hook GI as per TS
203Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
20411 KV DO Fuse 150A (For tapping points):
205Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three)
206Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
207Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm
208Supply, fitting & fixing of Galvanized Channel Cross Arm (100x50x6X2200) mm
209Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
210Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6) mm
211Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
212Supply, Fixing and Fitting of GI wire 6 SWG for Earthing
213Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
214Construction of 0 Ckm of new three phase LT lines on AB XLPE cable using SP-22 poles as per technical specifications, scope of works and approved drawings
215Supply, erection,Fixing and Fitting of GI Steel Tubular Pole SP-22 with PCC grouting as per T.S.
216Supply , Stringing, fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (3C x 50 sqmm + 1Cx35 sqmm)
217Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables.
218Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for GI Steel Tubular Pole SP-22
219Supply, Fixing and Fitting of GI I-Hook
220Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard
221Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard
222Supply fitting & fixing of Cable end caps for ABC cables
223Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB.
224Supply, fitting & fixing of ASA distribution box (with pre fitted lug for service connection) for 3-phase, 250 Amps busbars, for 1 no. 3-phase input and 9 no. 3-phase outputs with 1.5 mtr. 4C x 25 Sq. mm PVC cable (Al conductor) for charging DB
225Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long)
226Supply fitting & fixing Buckles for Steel Straps for DB fixing
227Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP50 for DB Charging as per NFC Std.
228Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std.
229Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std.
230Supply,Erection, fitting & fixing of LT Stay Set as per TS
231Supply, Fitting and Fixing of LT Guy Insulator Porcelain as per TS
232Supply, Fixing and Fitting of GI Stay wire 7/14 SWG
233Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification
234Supply, Fixing and Fitting of GI wire 6 SWG for Earthing with GI Nut and Bolts
235Supply Fitting and Fixing of LT Danger Plate (1.6mm thick)
236Grouting & muffering of steel tubular poles with M-10 Concreting as per TS
237Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager
238Construction of 0 Ckm of new single phase LT lines on AB XLPE cable using SP-22 poles as per technical specifications, scope of works and approved drawings
239Supply, erection,Fixing and Fitting of GI Steel Tubular Pole SP-22 as per T.S.
240Supply Stringing,fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (1C x 35 sqmm + 1Cx25 sqmm)
241Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables.
242Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for GI Steel Tubular Pole SP-22
243Supply, Fixing and Fitting of GI I-Hook
244Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard
245Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard
246Supply fitting & fixing of Cable end caps for ABC cables
247Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB.
248Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long)
249Supply fitting & fixing Buckles for Steel Straps for DB fixing
250Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std.
251Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP25 for DB Charging as per NFC Std.
252Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std.
253Supply, Erection,fitting & fixing of LT Stay Set as per TS
254Supply, Fitting and Fixing of LT Guy Insulator Porcelain as per TS
255Supply, Fixing and Fitting of GI Stay wire 7/14 SWG
256Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification
257Supply, Fixing and Fitting of GI wire 6 SWG for Earthing with GI Nut and Bolts
258Supply Fitting and Fixing of LT Danger Plate (1.6mm thick)
259Grouting & muffering of steel tubular poles with M-10 Concreting as per TS
260Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager
261Construction of 0 Nos of 63 KVA DTR Substation using SP-56 pole, as per technical specifications, scope of works and approved drawings
262Supply,erection Fixing and Fitting of GI Steel Tubular Pole SP-56 as per T.S, IS and approved GTP
263Supply, fitting & installation of 3-phase, 4 star, BIS Level - II, aluminium wound distribution transformer, 11/0.433 kV, 63 kVA, with bi-metallic terminal connectors at both HT & LV side
264Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.)
265Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of DTR Cubical etc.
266Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp
267Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
268Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
269Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three)
270Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three)
271Supply,Erection, Fitting and Fixing of Stay set (HT) as per TS
272Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS
273Supply, Fixing and Fitting of GI Stay wire 7/10 SWG
274Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
275Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing
276Supply ,fitting & fixing of DTR Cubicle for 63 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc)
277Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
278Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C)
279Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR
280Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick)
281Supply ,erection, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor
282Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
283Supply, stringing, testing & Commissioning of XLPE Cable 1-Core 95 sq. mm unarmoured (Aluminium)
284Supply fitting & fixing of Bi-metallic Lug 50 sq.mm.
285Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A)
286Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work
287Grouting & muffering of steel tubular poles with M-10 Concreting as per TS
288Supply fitting & fixing of 11 kV Gang Operated AB Switch:
289Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A
290Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm(2 no for AB Swtich, 1 no. for Handle fixing)
291Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
292Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
293Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch
294Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
295Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
296Supply, fitting and Fixing of I Hook GI as per TS
297Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel)
298Sign Board installation inclusive of supply, installation and painting as per TS
299Construction of 0 Nos of 25 KVA DTR Substation using SP-56 pole, as per technical specifications, scope of works and approved drawings
300Supply, erection Fixing and Fitting of GI Steel Tubular Pole SP-56 as per T.S, IS and approved GTP
301Supply, fitting, installation,, testing and Commissioning of 3-phase, (4 star, BIS Level-II), Aluminium wound distribution transformer, 11/0.433 kV, 25 kVA, with bi-metallic terminal connectors at both LV and HV side
302Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm ( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.)
303Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of main switch meter box etc.
304Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp
305Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
306Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm
307Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three)
308Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three)
309Supply,Erection, Fitting and Fixing of Stay set (HT) as per TS
310Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS
311Supply, Fixing and Fitting of GI Stay wire 7/10 SWG
312Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
313Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing
314Supply fitting & fixing of DTR Cubicle for 25 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc)
315Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
316Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C)
317Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR
318Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick)
319Supply ,erection, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor
320Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
321Supply, stringing, testing & Commissioning ofXLPE Cable 1-Core 50 sq. mm unarmoured (Aluminium)
322Supply fitting & fixing of Bi-metallic Lug 50 sq.mm.
323Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A)
324Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work
325Grouting & muffering of steel tubular poles with M-10 Concreting as per TS
326Supply fitting & fixing of 11 kV Gang Operated AB Switch:
327Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A
328Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm
329Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm
330Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work
331Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch
332Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted)
333Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS
334Supply, fitting and Fixing of I Hook GI as per TS
335Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel)
336Sign Board installation inclusive of supply, installation and painting as per TS
337Construction of 5836 Nos of Service Connection to Beneficiaries
338Supply Stringing of Un-armoured PVC Cable 2 core, 4.0 Sq mm.
339Supply, Fixing and Fitting of GI Wire,10 SWG. (for Service Wire Carrier & earthing)
340Supply, Fixing and Fitting of GI Pipe (25x1800) mm for earthing with required nuts-bolts & washer.
341Supply, Fixing and Fitting of Piano type switch (ISI mark), 5A 240V, Switch
342Supply, fitting & fixing of Fibre Glass Reinforced (SMC) board 350x200x40 mm for fixing Energy Meter & Cut-out.
343Supply ,fitting & fixing of Fiber Glass Reinforced Polyester Sheet Moulding Compound (SMC) board 200x150x40mm for fixing Swithes, Socket & MCB.
344Supply, Fixing and Fitting of Pin type LED lamp, operating voltage range 144 -288 Volts up to 9 Watts (capable to produce minimum illumination of 710 lumens) as per specifications. Specially made for DDUGJY.
345Supply fitting & fixing of Bakelite/Plastic lamp holder (ISI marked) 5A, 240 volts, angle.
346Supply Fitting & Fixing of Bakelite round base to house lamp holder.
347Supply & erection of Three-pin socket (ISI marked) 5A, 240V.
348Supply and fitting of 16 A Double Pole Miniature Circuit Breaker (MCB) (ISI marked). As per TS
349Supply, Fitting and Fixing of ISI Marked PVC 1 Core 1.5 sq.mm. copper multi-strand conductor cable as per Specification for internal wiring.
350Supply, Fixing and Fitting of GI Pipe (25x3000)mm with angle, bend, socket & clamp for service support
351Supply, Fixing and Fitting of Plastic Tie of required size for tieing the PVC Service Cable and the GI carrier.

AI Tender Summary

OUR REF NO 57954915
AUTHORITY Government Departments
TENDER VALUE 14.22 Crore
LAST DATE 29-10-2026
Authority
Authority Name Assam Power Distribution Company Limited
Work Description Tender for Electrification Of Additional Un-Electrified Households In The State Of Assam Under Rev Ed Reforms Linked Results Based Distribution Sector Scheme (Rdss, Addl. Hh) For Additional Package Of Goalpara District
Basic Detail
Tender No APDCL/CGMRE/RDSSAddlHH_44GLP
Bidding Type Tender
Location
City Goalpara
State Assam
Key Dates
Publish Date 09 Oct 2026
Submission Date 29 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 14.22 Crore
Tender Fee 20000
EMD 28.45 Lakhs
Exemption Available
Document List
44_Goalpara.rar
BOQ_85321.xls
ca12bc8c-4465-45dd-bc2b-9b0c2df0d791.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
rar

44_Goalpara.rar

xls

BOQ_85321.xls

html

ca12bc8c-4465-45dd-bc2b-9b0c2df0d791.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender