Tender For Electrification Of Additional Un-Electrified Households In The State Of Assam Under Rev Ed Reforms Linked Results Based Distribution Sector Scheme (Rdss, Addl. Hh) For Additional Package Of Goalpara District
Tender Value
14.22 Crore
Estimated cost
Bid Submission
29 Oct 2026
1 days left
EMD
28.45 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Goalpara → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrification Of Additional Un-Electrified Households In The State Of Assam Under Rev Ed Reforms Linked Results Based Distribution Sector Scheme (Rdss, Addl. Hh) For Additional Package Of Goalpara District
BOQ
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information |
| 2 | Construction of new 11 kV line along with installation of 25,63 kVA DTR and new LT lines on single and three phase AB cable for electrification of Un electrified household as per technical specifications, scope of works and approved drawings : |
| 3 | Total Amount of Supply Price |
| 4 | Total Amount of Installation/Erection charges |
| 5 | Total of complete work |
| 6 | Discount if any Offered by Bidder in % |
| 7 | Construction of new 11 kV line along with installation of 25,63 kVA DTR and new LT lines on single and three phase AB cable for electrification of Un electrified household as per technical specifications, scope of works and approved drawings under: |
| 8 | Goalpara District |
| 9 | Construction of 38.2 Ckm, 11 kV Line on ACSR Rabbit conductor using 8.5 M P.S.C poles as per technical Specification, scope of works and approved drawings |
| 10 | Supply & erection of PSC Pole 8.5 Mtr. (550kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm/ M10 Concreting at base |
| 11 | Supply and fitting of 11 KV 'T' Cross Arm (GI) with angle size 50x50x6mm as per TS |
| 12 | Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm |
| 13 | Supply, fitting & fixing of Galvanized Channel (100x50x6X2200) mm for height rising |
| 14 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 15 | Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C) |
| 16 | Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR |
| 17 | Supply ,Stringing, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor |
| 18 | Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS |
| 19 | Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS |
| 20 | Supply, Fixing and Fitting of GI Stay wire 7/10 SWG |
| 21 | Supply fitting and fixing of Galvanized Angle Cross Arm (50x50x6) mm for Cross Bracing for DP/TPs/FPs, as per T.S. |
| 22 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 23 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 24 | Supply, Fitting and Fixing of Jointing Sleeve for Rabbit ACSR |
| 25 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 26 | Supply and fixing of AI. Bi-metallic Binding Wire (10 SWG.) |
| 27 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6) mm |
| 28 | Supply , fitting & fixing of Fish Plate ( 50x6) mm |
| 29 | Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A) |
| 30 | Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick) |
| 31 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 32 | Grouting of poles with M-10 Concreting as per TS |
| 33 | Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager |
| 34 | Line Crossing - Line to line / Road: |
| 35 | Supply, fitting & fixing of Galvanized Angle Cross Arm (50x50x6X2500) mm for Guarding |
| 36 | Supply, Fixing and Fitting of GI wire 8 SWG for Guarding as per T.S |
| 37 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 38 | Supply, fitting and Fixing of I Hook GI as per TS |
| 39 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 40 | 11 KV DO Fuse 150A (For tapping points): |
| 41 | Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three) |
| 42 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 43 | Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm |
| 44 | Supply, fitting & fixing of Galvanized Channel Cross Arm (100x50x6X2200) mm |
| 45 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 46 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6) mm |
| 47 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 48 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 49 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 50 | Construction of 38.9 Ckm new three phase LT lines on AB XLPE cable using 7.5 Mtr PSC poles as per technical specifications, scope of works and approved drawings |
| 51 | Supply & erection of PSC Pole 7.5 Mtr. (350kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm / M10 Concreting at base upto 75 mm from bottom |
| 52 | Supply ,Stringing ,fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (3C x 50 sqmm + 1Cx35 sqmm) |
| 53 | Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables. |
| 54 | Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for 7.5 mtr. PSC Pole |
| 55 | Supply, Fixing and Fitting of GI I-Hook |
| 56 | Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard |
| 57 | Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard |
| 58 | Supply fitting & fixing of Cable end caps for ABC cables |
| 59 | Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB. |
| 60 | Supply, fitting & fixing of ASA distribution box (with pre fitted lug for service connection) for 3-phase, 250 Amps busbars, for 1 no. 3-phase input and 9 no. 3-phase outputs with 1.5 mtr. 4C x 25 Sq. mm PVC cable (Al conductor) for charging DB |
| 61 | Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long) |
| 62 | Supply fitting & fixing Buckles for Steel Straps for DB fixing |
| 63 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP50 for DB Charging as per NFC Std. |
| 64 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std. |
| 65 | Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std. |
| 66 | Supply, Erection,fitting & fixing of LT Stay Set as per TS |
| 67 | Supply, Fitting and Fixing of LT Guy Insulator Porcelain as per TS |
| 68 | Supply, Fixing and Fitting of GI Stay wire 7/14 SWG |
| 69 | Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification |
| 70 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 71 | Supply Fitting and Fixing of LT Danger Plate (1.6mm thick) |
| 72 | Supply, fitting & fixing of Galvanized Channel (100x50x6X2200) mm for height rising |
| 73 | Grouting of poles with M-10 Concreting as per TS |
| 74 | Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager |
| 75 | Construction of 68.7 Ckm new single phase LT lines on AB XLPE cable using 7.5 Mtr PSC poles as per technical specifications, scope of works and approved drawings |
| 76 | Supply & erection of PSC Pole 7.5 Mtr. (350kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm / M10 Concreting at base upto 75 mm from bottom |
| 77 | Supply ,Stringing ,fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (1C x 35 sqmm + 1Cx25 sqmm) |
| 78 | Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables. |
| 79 | Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for 7.5 mtr. PSC Pole |
| 80 | Supply, Fixing and Fitting of GI I-Hook |
| 81 | Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard |
| 82 | Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard |
| 83 | Supply fitting & fixing of Cable end caps for ABC cables |
| 84 | Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB. |
| 85 | Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long) |
| 86 | Supply fitting & fixing Buckles for Steel Straps for DB fixing |
| 87 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std. |
| 88 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP25 for DB Charging as per NFC Std. |
| 89 | Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std. |
| 90 | Supply, Erection,fitting & fixing of LT Stay Set as per TS |
| 91 | Supply, fitting & fixing of LT Guy Insulator Porcelain |
| 92 | Supply, Fixing and Fitting of GI Stay wire 7/14 SWG |
| 93 | Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification |
| 94 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 95 | Supply Fitting and Fixing of LT Danger Plate (1.6mm thick) |
| 96 | Supply, fitting & fixing of Galvanized Channel (100x50x6X2200) mm for height rising |
| 97 | Grouting of poles with M-10 Concreting as per TS |
| 98 | Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager |
| 99 | Construction of 70 Nos of 63 KVA DTR Substation using 8.5 Mtr PSC pole, as per technical specifications, scope of works and approved drawings |
| 100 | Supply & erection of PSC Pole 8.5 Mtr. (550kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm/ M10 Concreting at base |
| 101 | Supply, fitting & installation of 3-phase, 4 star, BIS Level - II, aluminium wound distribution transformer, 11/0.433 kV, 63 kVA, with bi-metallic terminal connectors at both HT & LV side |
| 102 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm ( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.) |
| 103 | Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp |
| 104 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 105 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 106 | Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three) |
| 107 | Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three) |
| 108 | Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS |
| 109 | Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS |
| 110 | Supply, Fixing and Fitting of GI Stay wire 7/10 SWG |
| 111 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 112 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing |
| 113 | Supply ,fitting & fixing of DTR Cubicle for 63 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc) |
| 114 | Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of DTR Cubical etc. |
| 115 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 116 | Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C) |
| 117 | Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR |
| 118 | Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick) |
| 119 | Supply ,Stringing, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor |
| 120 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 121 | Supply, stringing, testing & Commissioning of XLPE Cable 1-Core 95 sq. mm unarmoured (Aluminium) |
| 122 | Supply fitting & fixing of Bi-metallic Lug 50 sq.mm. |
| 123 | Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A) |
| 124 | Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work |
| 125 | Grouting of poles with M-10 Concreting as per TS |
| 126 | Supply fitting & fixing of 11 kV Gang Operated AB Switch: |
| 127 | Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A |
| 128 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm(2 no for AB Swtich, 1 no. for Handle fixing) |
| 129 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 130 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 131 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch |
| 132 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 133 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 134 | Supply, fitting and Fixing of I Hook GI as per TS |
| 135 | Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel) |
| 136 | Sign Board installation inclusive of supply, installation and painting as per TS |
| 137 | Construction of 14 Nos of 25 KVA DTR Substation using 8.5 Mtr PSC pole, as per technical specifications, scope of works and approved drawings |
| 138 | Supply & erection of PSC Pole 8.5 Mtr. (550kg) long as per Technical Specifications and along with RCC base plate of size (450x450x75)mm/ M10 Concreting at base |
| 139 | Supply, fitting & installation of 3-phase, (4 star, BIS Level-II), Aluminium wound distribution transformer, 11/0.433 kV, 25 kVA, with bi-metallic terminal connectors at both LV and HV side |
| 140 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm ( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.) |
| 141 | Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp |
| 142 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 143 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 144 | Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three) |
| 145 | Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three) |
| 146 | Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS |
| 147 | Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS |
| 148 | Supply, Fixing and Fitting of GI Stay wire 7/10 SWG |
| 149 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 150 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing |
| 151 | Supply fitting & fixing of DTR Cubicle for 25 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc) |
| 152 | Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of main switch meter box etc. |
| 153 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 154 | Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C) |
| 155 | Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR |
| 156 | Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick) |
| 157 | Supply ,Stinging, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor |
| 158 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 159 | Supply, stringing, testing & Commissioning of XLPE Cable 1-Core 50 sq. mm unarmoured (Aluminium) |
| 160 | Supply fitting & fixing of Bi-metallic Lug 50 sq.mm. |
| 161 | Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A) |
| 162 | Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work |
| 163 | Grouting of poles with M-10 Concreting as per TS |
| 164 | Supply fitting & fixing of 11 kV Gang Operated AB Switch: |
| 165 | Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A |
| 166 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm |
| 167 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 168 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 169 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch |
| 170 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 171 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 172 | Supply, fitting and Fixing of I Hook GI as per TS |
| 173 | Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel) |
| 174 | Sign Board installation inclusive of supply, installation and painting as per TS |
| 175 | Construction of 0 Ckm of 11 kV Line on ACSR Rabbit conductor using SP-56 poles as per technical Specification, scope of works and approved drawings |
| 176 | Supply, erection,Fixing and Fitting of GI Steel Tubular Pole SP-56 as per T.S, IS and approved GTP |
| 177 | Supply , fitting & fixing of G I Channel Section 75x40x6x1100 mm and 75x40x6x350 mm GI top cleat for fixing of 11 KV polymeric Pin insulator |
| 178 | Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm |
| 179 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 180 | Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C) |
| 181 | Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR |
| 182 | Supply ,Stringing, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor |
| 183 | Supply, Erection,Fitting and Fixing of Stay set (HT) as per TS |
| 184 | Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS |
| 185 | Supply, Fixing and Fitting of GI Stay wire 7/10 SWG |
| 186 | Supply fitting and fixing of Galvanized Angle Cross Arm (50x50x6) mm for Cross Bracing for DP/TPs/FPs, as per T.S. |
| 187 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 188 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 189 | Supply, Fitting and Fixing of Jointing Sleeve for Rabbit ACSR |
| 190 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 191 | Supply and fixing of AI. Bi-metallic Binding Wire (10 SWG.) |
| 192 | Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp |
| 193 | Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A) |
| 194 | Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick) |
| 195 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 196 | Grouting & muffering of steel tubular poles with M-10 Concreting as per TS |
| 197 | Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager |
| 198 | Line Crossing - Line to line / Road: |
| 199 | Supply, fitting & fixing of Galvanized Angle Cross Arm (50x50x6X2500) mm for Guarding |
| 200 | Supply, Fixing and Fitting of GI wire 8 SWG for cross lacing as per T.S |
| 201 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing & Guarding with GI Nut and Bolts |
| 202 | Supply, fitting and Fixing of I Hook GI as per TS |
| 203 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 204 | 11 KV DO Fuse 150A (For tapping points): |
| 205 | Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three) |
| 206 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 207 | Supply, fitting & fixing of Galvanized Channel Cross Arm (75x40x6X2200) mm |
| 208 | Supply, fitting & fixing of Galvanized Channel Cross Arm (100x50x6X2200) mm |
| 209 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 210 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6) mm |
| 211 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 212 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing |
| 213 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 214 | Construction of 0 Ckm of new three phase LT lines on AB XLPE cable using SP-22 poles as per technical specifications, scope of works and approved drawings |
| 215 | Supply, erection,Fixing and Fitting of GI Steel Tubular Pole SP-22 with PCC grouting as per T.S. |
| 216 | Supply , Stringing, fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (3C x 50 sqmm + 1Cx35 sqmm) |
| 217 | Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables. |
| 218 | Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for GI Steel Tubular Pole SP-22 |
| 219 | Supply, Fixing and Fitting of GI I-Hook |
| 220 | Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard |
| 221 | Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard |
| 222 | Supply fitting & fixing of Cable end caps for ABC cables |
| 223 | Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB. |
| 224 | Supply, fitting & fixing of ASA distribution box (with pre fitted lug for service connection) for 3-phase, 250 Amps busbars, for 1 no. 3-phase input and 9 no. 3-phase outputs with 1.5 mtr. 4C x 25 Sq. mm PVC cable (Al conductor) for charging DB |
| 225 | Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long) |
| 226 | Supply fitting & fixing Buckles for Steel Straps for DB fixing |
| 227 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP50 for DB Charging as per NFC Std. |
| 228 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std. |
| 229 | Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std. |
| 230 | Supply,Erection, fitting & fixing of LT Stay Set as per TS |
| 231 | Supply, Fitting and Fixing of LT Guy Insulator Porcelain as per TS |
| 232 | Supply, Fixing and Fitting of GI Stay wire 7/14 SWG |
| 233 | Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification |
| 234 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing with GI Nut and Bolts |
| 235 | Supply Fitting and Fixing of LT Danger Plate (1.6mm thick) |
| 236 | Grouting & muffering of steel tubular poles with M-10 Concreting as per TS |
| 237 | Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager |
| 238 | Construction of 0 Ckm of new single phase LT lines on AB XLPE cable using SP-22 poles as per technical specifications, scope of works and approved drawings |
| 239 | Supply, erection,Fixing and Fitting of GI Steel Tubular Pole SP-22 as per T.S. |
| 240 | Supply Stringing,fitting & fixing of CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (1C x 35 sqmm + 1Cx25 sqmm) |
| 241 | Supply, Fixing and Fitting of Plastic Tie of required size for tieing the AB Cables. |
| 242 | Supply, Fixing and Fitting of GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for GI Steel Tubular Pole SP-22 |
| 243 | Supply, Fixing and Fitting of GI I-Hook |
| 244 | Supply and installation of Anchor clamp / dead end clamp, wedge type for L.T. A.B. cables as per NFC standard |
| 245 | Supply fitting & fixing of Suspension Clamp ABC as per NFC Standard |
| 246 | Supply fitting & fixing of Cable end caps for ABC cables |
| 247 | Supply, fitting & fixing of ASA distribution box for 140 Amps, 1-PH, 8 connector with busbar system for 1 no. 1-phase input and 7 no. 1-phase outputs with 1.5 mtr. 2C x 16 Sq. mm PVC cable (Al conductor) for charging DB. |
| 248 | Supply, Fitting and Fixing of Steel Strap for installing DB (Size: 20 mm x 1 mtr long) |
| 249 | Supply fitting & fixing Buckles for Steel Straps for DB fixing |
| 250 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std. |
| 251 | Supply, Fitting and Fixing of Insulating Piercing Connector IPC EP25 for DB Charging as per NFC Std. |
| 252 | Supply, Fitting and Fixing of Insulated crimping type midspan joint (for phase & neutral) as per NFC Std. |
| 253 | Supply, Erection,fitting & fixing of LT Stay Set as per TS |
| 254 | Supply, Fitting and Fixing of LT Guy Insulator Porcelain as per TS |
| 255 | Supply, Fixing and Fitting of GI Stay wire 7/14 SWG |
| 256 | Supply, Fitting and Fixing of Spike earthing 25mm dia & 2500 mm length with 8swg GI earthing wire as per technical specification |
| 257 | Supply, Fixing and Fitting of GI wire 6 SWG for Earthing with GI Nut and Bolts |
| 258 | Supply Fitting and Fixing of LT Danger Plate (1.6mm thick) |
| 259 | Grouting & muffering of steel tubular poles with M-10 Concreting as per TS |
| 260 | Survey, pole numbering, preperation of survey report and uploading in the web portal after approval of the Project Manager |
| 261 | Construction of 0 Nos of 63 KVA DTR Substation using SP-56 pole, as per technical specifications, scope of works and approved drawings |
| 262 | Supply,erection Fixing and Fitting of GI Steel Tubular Pole SP-56 as per T.S, IS and approved GTP |
| 263 | Supply, fitting & installation of 3-phase, 4 star, BIS Level - II, aluminium wound distribution transformer, 11/0.433 kV, 63 kVA, with bi-metallic terminal connectors at both HT & LV side |
| 264 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.) |
| 265 | Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of DTR Cubical etc. |
| 266 | Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp |
| 267 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 268 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 269 | Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three) |
| 270 | Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three) |
| 271 | Supply,Erection, Fitting and Fixing of Stay set (HT) as per TS |
| 272 | Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS |
| 273 | Supply, Fixing and Fitting of GI Stay wire 7/10 SWG |
| 274 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 275 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing |
| 276 | Supply ,fitting & fixing of DTR Cubicle for 63 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc) |
| 277 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 278 | Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C) |
| 279 | Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR |
| 280 | Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick) |
| 281 | Supply ,erection, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor |
| 282 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 283 | Supply, stringing, testing & Commissioning of XLPE Cable 1-Core 95 sq. mm unarmoured (Aluminium) |
| 284 | Supply fitting & fixing of Bi-metallic Lug 50 sq.mm. |
| 285 | Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A) |
| 286 | Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work |
| 287 | Grouting & muffering of steel tubular poles with M-10 Concreting as per TS |
| 288 | Supply fitting & fixing of 11 kV Gang Operated AB Switch: |
| 289 | Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A |
| 290 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm(2 no for AB Swtich, 1 no. for Handle fixing) |
| 291 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 292 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 293 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch |
| 294 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 295 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 296 | Supply, fitting and Fixing of I Hook GI as per TS |
| 297 | Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel) |
| 298 | Sign Board installation inclusive of supply, installation and painting as per TS |
| 299 | Construction of 0 Nos of 25 KVA DTR Substation using SP-56 pole, as per technical specifications, scope of works and approved drawings |
| 300 | Supply, erection Fixing and Fitting of GI Steel Tubular Pole SP-56 as per T.S, IS and approved GTP |
| 301 | Supply, fitting, installation,, testing and Commissioning of 3-phase, (4 star, BIS Level-II), Aluminium wound distribution transformer, 11/0.433 kV, 25 kVA, with bi-metallic terminal connectors at both LV and HV side |
| 302 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm ( Top Channel-2no, Do Fuse-1 no., DTR Base Channel-2no.) |
| 303 | Supply fitting & fixing of GI Angle (50x50x6X2200)mm for fitting & fixing of main switch meter box etc. |
| 304 | Supply, Fixing and Fitting of GI Flat (50x6 mm) Jam Clamp |
| 305 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 306 | Supply fitting & fixing of Composite Polymeric 11 kV Pin Insulator (5 KN) FRP 24mm |
| 307 | Supply,erection ,testing and commissioning of 11 KV DO Fuse 150A (Set of three) |
| 308 | Supply,erection ,testing and commissioning of 12 KV 9KA Lighting arrestor Line Type (Set of three) |
| 309 | Supply,Erection, Fitting and Fixing of Stay set (HT) as per TS |
| 310 | Supply, Fitting and Fixing of Guy Insulator (HT) Porcelain as per TS |
| 311 | Supply, Fixing and Fitting of GI Stay wire 7/10 SWG |
| 312 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 313 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 2 nos. transformer body earthing ,1 no. LA earthing, 1 no. DB earthing & 2 no. for DTR Neutral earthing |
| 314 | Supply fitting & fixing of DTR Cubicle for 25 KVA DTRs (comprising of requisite MCCB for incoming and outgoing along with busbar arrangement etc) |
| 315 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 316 | Supply, fitting & Fixing of 11kV polymer Disc insulator (70KN) with Hardware Fittings (T&C) |
| 317 | Supply Fitting and Fixing of Tension Clamp for Rabbit ACSR |
| 318 | Supply Fitting and Fixing of 11 KV Danger Plate (1.6mm thick) |
| 319 | Supply ,erection, testing and commissioning of ACSR( 50 mm sq) Rabbit Conductor |
| 320 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 321 | Supply, stringing, testing & Commissioning ofXLPE Cable 1-Core 50 sq. mm unarmoured (Aluminium) |
| 322 | Supply fitting & fixing of Bi-metallic Lug 50 sq.mm. |
| 323 | Supply, fitting & fixing of GI Barbed Wire for anticlimbing device (12 SWG=2.5mm) (Type A) |
| 324 | Supply, Fixing and Fitting of Goat Proof Security GI Fancing for DTR as per TS with civil work |
| 325 | Grouting & muffering of steel tubular poles with M-10 Concreting as per TS |
| 326 | Supply fitting & fixing of 11 kV Gang Operated AB Switch: |
| 327 | Supply,erection ,testing and commissioning of 11 KV Gang operated switch 400 A |
| 328 | Supply, Fitting and Fixing of GI Channel Cross Arm (100x50x6X2200)mm |
| 329 | Supply, Fixing and Fitting of Pole Clamp of GI flat (50x6)mm |
| 330 | Supply, fitting & fixing of 100 mm dia CI Earth pipe 1800 mm length as per technical specification, approved drawings and scope of work |
| 331 | Supply,fitting & fixing of G.I. Earthing Strip of 25 mm x 3 mm for 1 no. AB Switch |
| 332 | Supply, Fixing and Fitting of GI Nuts & Bolts with GI washer (Assorted) |
| 333 | Supply, fitting & fixing of PG Clamp for Rabbit ACSR as per TS |
| 334 | Supply, fitting and Fixing of I Hook GI as per TS |
| 335 | Supply, Fitting and Fixing of GI Channel Section (100x50x6X520)mm (for DTR Base Support Channel) |
| 336 | Sign Board installation inclusive of supply, installation and painting as per TS |
| 337 | Construction of 5836 Nos of Service Connection to Beneficiaries |
| 338 | Supply Stringing of Un-armoured PVC Cable 2 core, 4.0 Sq mm. |
| 339 | Supply, Fixing and Fitting of GI Wire,10 SWG. (for Service Wire Carrier & earthing) |
| 340 | Supply, Fixing and Fitting of GI Pipe (25x1800) mm for earthing with required nuts-bolts & washer. |
| 341 | Supply, Fixing and Fitting of Piano type switch (ISI mark), 5A 240V, Switch |
| 342 | Supply, fitting & fixing of Fibre Glass Reinforced (SMC) board 350x200x40 mm for fixing Energy Meter & Cut-out. |
| 343 | Supply ,fitting & fixing of Fiber Glass Reinforced Polyester Sheet Moulding Compound (SMC) board 200x150x40mm for fixing Swithes, Socket & MCB. |
| 344 | Supply, Fixing and Fitting of Pin type LED lamp, operating voltage range 144 -288 Volts up to 9 Watts (capable to produce minimum illumination of 710 lumens) as per specifications. Specially made for DDUGJY. |
| 345 | Supply fitting & fixing of Bakelite/Plastic lamp holder (ISI marked) 5A, 240 volts, angle. |
| 346 | Supply Fitting & Fixing of Bakelite round base to house lamp holder. |
| 347 | Supply & erection of Three-pin socket (ISI marked) 5A, 240V. |
| 348 | Supply and fitting of 16 A Double Pole Miniature Circuit Breaker (MCB) (ISI marked). As per TS |
| 349 | Supply, Fitting and Fixing of ISI Marked PVC 1 Core 1.5 sq.mm. copper multi-strand conductor cable as per Specification for internal wiring. |
| 350 | Supply, Fixing and Fitting of GI Pipe (25x3000)mm with angle, bend, socket & clamp for service support |
| 351 | Supply, Fixing and Fitting of Plastic Tie of required size for tieing the PVC Service Cable and the GI carrier. |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender