Tender For Renovation Of Accounts Branch And Administrative Branch Moh Building, 30 Bays Building, Sector 17, Chandigarh.
Tender Value
80.11 Lakhs
Estimated cost
Bid Submission
16 Oct 2026
6 days left
EMD
1.60 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Accounts Branch And Administrative Branch Moh Building, 30 Bays Building, Sector 17, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete andstacking within 50 metres lead :Of area 3 sq. metres and below |
| 2 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm. (DSR 15.23.1) |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 5 | Disposal moorum/building rubbish/malba/similar unservicable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved muncipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Enginner -in- charge. |
| 6 | Dismantling wooden /aluminium /gypsum partitions doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level: ( 1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size).DSR 4.1.10 |
| 8 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board |
| 9 | Providing and fixing of lay-grid false ceiling 15 mm thick densified tegular edged eco friendly light weight calcium silicate consisting of ceilling tiles Armstrong/Anutone or equivalent as per approved sample of size 2' x 2' lay-in-modular grid/ suspension system ( hot dipped galvanized steel) of standard T-Section having its flanges face powder coaed colour white suspended from ceiling and secured with clips and G.I. etc with following details.(a) Main runners shall be T-Shaped section with single rotary stitching of size 24mm x 36 mm and 3600mm long (b) Cross runners shall be T-Shaped double rotary stitching of size 24mm x 26mm and 1200mm long.Cross runner T-Section of 24mm x 26mm and 600mm long. The frame work comprises of main gunners spaced at 1200mm centre to centre shall be securely fixes to the structural soffits by approved hangers at 1200mm maximum centres. The hangers (G.I. wire of 4mm dia) to be fixed by means of roof plug, level adjuster and screws etc. Flush fittiing 1200mm long cross tees (with double stitching) to be interlocked between main runners at 600mm centre ti firn 1200 x 600mm modules. Cut cross tees longer that 600mm to be supported independently to form 600x600mm modules. The complete work shall include the cost of all material and labour and lead and fit complete and to the entire satisfaction of Engineer-in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 10 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. |
| 11 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier ,wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of Size. Size of Tile 600 x 1200 mm |
| 12 | Glazed Vitrified tiles Matt/Antiskid finish of size (Size of Tile 600 x 600mm) |
| 13 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm. |
| 14 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) Conforming to IS: 15477, in average 3mm thickness. |
| 15 | PLASTER 12 mm thick cement plaster 1:4 |
| 16 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 17 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/liltre of approved brand and manufacture, including applying additional coates whereever required to achieve even shade and colour. Two coats. (DSR 13.83.2) |
| 18 | Providing and fixing wooden paneling with 9mm waterproof ply greenlam make on existing M.S. frame /wooden on both side fixed (i.e. horizontal and vertical ) in brick wall with the help of rawl plug/gutties and screws nails complete in all respect to the entire satisfaction of Engineer-in-Charge. |
| 19 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick. |
| 20 | Supply and fixing of Greenguard certified pentagonal modular workstation of approved make such as Herman Miller / Bristol / Godrej Interio / Steelcase or equivalent, of size 1500 mm (W1) × 1500 mm (W2) × 600 mm (D) × 750 mm (H) with partition height 1190 mm, made of factory-finished modular panel system having panel thickness 65 ± 1.5 mm with 69 mm trim width, complete with powder-coated CRCA steel framework, aluminum trims, fabric/metal tiles, concealed cable management system, 25 mm thick pre-laminated particle board worktop and side panels with PVC edge banding, all necessary hardware, fittings and accessories. |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Polyester powder coated aluminium (minimum thickness ofpolyester powder coating 50 micron) DSR 21.1.1.3 |
| 22 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSr 21.1.2.3) |
| 23 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm |
| 24 | Providing and fixing aluminium handing floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete in all respecte to the entire satisfaction of the Engineer-In-Charge.Twin rubber stopper (DSR 9.101.2) |
| 25 | Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.152x42x18 mm weighing not less than 60 gms DSR 9.108.1 |
| 26 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side DSR 21.2.1 |
| 27 | Renewing glass panes, with putty and nails wherever necessary includingracking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 28 | Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).DSR 9.12 |
| 29 | Providing and fixing 19mm + 1mm thick marine grade A ply for cupboard havng box of 6'-0\\" long, 2'-0\\" deep and 11'-0\\" high provided with one side decoratiove mica (laminated sheet) and other side balancing lamination covered with edges to be sealed with PVC edge bending 2.00 mm thick 19mm wide tape with hot glue by edge bending machine of approved brand including and back shall be covered with 6mm thick marine grade A ply including 4nos shelves of size 6'-0\\"x2'-0\\" and 2no's drawers of size 3'-0\\" x 1'-9\\" x 0'-9\\" with sliding arrangements, G profile handle in drawer & bottom with 6mm ply and to be fixed on wall with screws and gutties complete in all respect the entire satisfaction of Engineer-in-Charge. (Elevational area to be measured for payment) |
| 30 | Providing and fixing 19mm + 1mm thick commercial board cupboard shutters of 3'-0\\" long & 6'-3\\" high provided with teak veneer on all outer side and fixed in cupboard with two/three tier sliding and locking arrangement. The rate also includes the cost of handles, rollers, locking and other necessary arrangement etc. including the cost of filler and two or more coats of polish on outerside and innerside two or more coats of paint over one coat of wood primer and filler to provide smooth finish complete in all respect the entire satisfaction of Engineer-in-Charge. (Elevational area to be measured for payment) |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 13.61.1 |
| 32 | Providing and fixing stainless steel name plate of approved size (1' x 0'-6\\") and design, made of SS 304 grade sheet, including engraving/lettering, polishing, screws, fixtures and fixing complete as directed by Engineer-in-Charge. |
| 33 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR 16.90) |
| 34 | Providing and fixing roller blinds of approved make (Win Tree/Vista), shade and colour as approved by Engineer-in-Charge. The blinds shall be spring loaded resin operated media of polyester able limit rays allowing natural illumination. Spring loaded resin Mounted part made of up MS zinc coated of thickness of 2mm molded in PVC. Idler pin made of zinc plated MS of 9mm outer dia surrounded by bearing balls to support blinds at other end. This bidirectional blind shall be operational by assistance of polyester cord. This polyester cord should be molded inside PVC beads of 4.5mm outer dia. The blinds shall be operational without any hindrance. As per approved sample to the entire satisfaction of Engineer-In-Charge. |
| 35 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texturelaid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), jointstreated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing of edges to give high glossfinish etc. complete at all levels: Granite stone slab of colour black, Cherry/Ruby red: Area of slab over 0.50 sqm (DSR 8.2.2.2) |
| 36 | Credit of MS Steel |
| 37 | ELECTRICAL WORK |
| 38 | Providing and fixing under floor metal trunking (Raceway) powder coated stell sheet to make it rust proof made of 1.6 mm thick sheet metal Size M-Trunking 150x38x1.6 2 comp 2.5 Mtr 275 GSM including cutting the floor to the size and all repair work in CC motor1:2:4 after fixing the raceway finish to make goods the sameand complete the job in all respect utp the entire satisfaction of Enginner in Charge. |
| 39 | Providing and fixing of jointing sleeves receway of size all accessories as required and including cutting the floor to the size and all repair work in CC motor1:2:4 after fixing the raceway finish to make goods the same and complete the job in all respect utp the entire satisfaction of Enginner in Charge. |
| 40 | Supply and Erection of Crossover Junction box 2 component under Floor size 150x150x55.70 REc 8mm 120 GMS under Floor service outletbox. The cover plate for junction box and cross over junction box are mde of a 2.5mm thick epoxy powder coated lid, and include an 8MM recess to assist with the installation of carpeters and tiles. The trap frame (angle frame) for the junction box and cross over junction box is made of a 1.5 thick expoxy powder coated frame to provide rigidity and added strength and complete the job in all respect utp the entire satisfaction of Enginner in Charge. |
| 41 | Providing and Fixing of LED luminarie recess/surface mounting, Power coated housing made of CRCA sheet or its equivalent of size 2'x2' of 36-40 watt including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD <10%, PF > 0.95, Having coloured temperature 5700 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Philips/ Wipro/ Osram/ Twinkle Lux-Max/ Havells/ Trilux/ Panasonic/ alongwith connection, testing and commissioning etc. The fitting may be installed at the height of 20 feet. There should be a on site warranty for 5 years.This job also inclusive of all material required at site for entire satisfaction of Engineer-in-charge. |
| 42 | Point wiring in PVC conduit, with modular type switch: Wiring for light point/fan point/exhaust fan point/ cal bell point with 1.5 sq.mm FR PVC insulted copper conductor single core cable in surface/ recessed PVC Conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group-C |
| 43 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. |
| 44 | S/F modular boxes, base & cover plate: Supplying and fixing following size/modules, G.I. box alongwith modular base & cover plate for modular switches North West/ Crabitree/ Legrand/ National make. in recess etc as required. 2 Module (75mmX75mm) |
| 45 | 4 Module (125mmX75mm) |
| 46 | 6 Module 200mm x 755mm |
| 47 | 8 Module 125mm x125mm |
| 48 | 12 Module 200mm x150mm |
| 49 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 50 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 51 | S/I/T/C OF 6-9 Watt LED Downlighter, MINIMUM 100 Lumens/watt, THD <10%, Pf > 0.95, CCCV driver, protection IP 20, and CCT 4000-5700K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.Wattage - 7.5/9/10 watt MAKE- Havells, complete in all respect.All LED lights free replacement at site for a period of five year from the date of delivery, Toll free number shall be provided by the supplier to the client for all led lights. Exhaust fan etc. Complete in all respect, as required. |
| 52 | S/I/T/C OF 12-15 watt consild light MINIMUM 120 Lumens/watt, THD <10%, Pf > 0.95, CCCV driver, protection IP 20, and CCT 5700-65000K, Surge protection 4kV, Operating Voltage Range - 150V – 270Volts.Wattage - 12-15 watt MAKE- Havells, complete in all respect.All LED lights free replacement at site for a period of five year from the date of delivery, Toll free number shall be provided by the supplier to the client for all led lights. Exhaust fan etc. Complete in all respect, as required. |
| 53 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.).1 Run of cable.The cable to be approved from the Engineer in Charge. |
| 54 | Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 x 1.5 mm2 |
| 55 | Wiring in existing conduit:Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. Universal/ Finolex/ Polycab/ KEI/ Havell's/ Cirtina or Technically equivalent. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. Size 3 core x 4 mm2 |
| 56 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 57 | S/E of Wall fans 400mm sweep without fan regulator of Havell's-Swing/ Usha/ Baja/ Panasonic/ Orient make including making connection with 23/.076’ flexible wire to be adjacent fan point. The job shall be executed to the entire satisfaction of Engineer-in-charge. |
| 58 | Providing and fixing of 28 gauge copper piping between indoor & outdoor unit complete with sleeve type Kini insulation including the cost of chasing of brick wall, RCC & repairing the same in good conditions as per site requirement to the size & design of manufacture. size of copper pipe 5/8\\"x3/8\\" |
| 59 | Providing & Fixing PVC rigid drain pipe 20mm (3/4\\") dia of Diplast/ finolex make complete in all respects from indoor unit to disposal points as directed by Engineer in charge complete in all respects. |
| 60 | Supplying and fixing DP sheet steel enclosure on surface/recess along with 32/40/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required complete in all respect. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The specifications complete in all respect and to the entire satisfaction of Engineer-in-Charge. |
| 61 | Supply and Erection of Stand for Outdoor unit of 1.5/2/4 Ton Air Conditioners. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 62 | S/F modular type switch/socket: Supplying and fixing following modular switch /socket on the exisiting modular plate & switch box including connections but excluding modular plate Anchor Penta. in recess etc as required. 5/6 Amp switch |
| 63 | 15/16 Amp switch |
| 64 | 3 pin 5/6 Amp socket outlet |
| 65 | 6 pin 15/16 Amp socket outlet |
| 66 | G.I. Earth pipe electrode without salt/ Charcoal: DSR 5.2/2022 Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 3 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (without charcoal or coke and salt). The earth electrode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 67 | P/F 6 SWG GI earth wire in pipe: DSR 5.12/2022 Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 68 | Supplying and fixing Cable End Boxes (IP 43) suitable for following tripple pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.etc. ake of Panasonic, Anchor, Havells, Legrand, ABB, Siemens, L&T For 8 way, Double door TPN MCBDB |
| 69 | Providing & Fixing of Polyday 25mm flexible PVC pipe (Medium) as required complete in all respect. The job shall be executed to the entire satisfaction of Engineer-in-charge. |
| 70 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 200 Amp with Breaking Cap 35 kA, 415 Volts. Supply & Erection of 3 pole, 35 kA, 200 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 71 | Dismantling air conditioners (in all respect inclduing requirement of copper pipe/drain pipe, etc) at suitale height complete with copper pipe in all respect. The work shall be exectued as per the Satifaction of Engineer in charge. |
| 72 | Re erection of split type air conditioners (in all respect inclduing requirement of copper pipe/drain pipe, etc) at suitale height complete with copper pipe in all respect. The work shall be exectued as per the Satifaction of Engineer in charge. |
| 73 | Gas Charging of AC Split type 1.5/2 TR to the complete satisfaction of Engineer-in-Charge. |
| 74 | Supply & Erection of PVC Insulated sheathed) Copper Conductor Cable ISI marked size 3 core 2.5 mm2.Supply & Erection of ISI Marked PVC insulated 3 core 2.5mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Polycab/ Havell's/ left bare in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 3 core 2.5 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 75 | PVCCON S/F PVC Conduit:Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. (25mm) |
| 76 | Supply and Erection of Three Phase ETP grade Copper Bus Bar with enclosure of rating 200 amp. to be fixed on wall/ in main incoming panel complete in all respects of make: Havells- IHBC010004 or equivalent in ABB /Schneider /Legrand.The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 77 | S/E of Ceiling Fans 1200mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Havell's/ Bajaj/ Crompton/ Panasonic including making connection with 23/.076' flexible wire to be adjacent fan point with regulator. The work shall be executed to the entire satisfaction of Engineer in charge. |
| 78 | Providing and Fixing of Split type AC of 1.5 ton, 3 Star Rating. The AC shall be Suitable for 230 +/- 10% volts, 50 Hz Ac supply. The cost of including piping / Electrical Wire between indoor & outdoor up to two meter with sleevein type insulation I/C M.S brackets/stand for outdoor until as per madufactures standard i.e. for fixing on wall or floor/terrace as per site requirements complete in the entire statisfaction of Engineer-in-charge. The AC EER not less than 3.55 supply with Copper candensar. 1.5 Ton Capacity of nominal cooling capacity 4500 kilo calories/Hr./18000 BTU/Hr. with permissible variation of +/- 10%. Room discharge air flow 650 cfm inddor Nosir level not exceed 50 db. Refrigent 410 A/R32. Machine should have in built gas leak detctor. The make should be Carrier/ Hitachi/ Toshiba or its equivalent. There should be warrantee of 3 years in all respect to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender