Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #57954612

Tender For Special Repair To Wiring At Certain Otm Bldg And Roof Treatment At Certain Md Accn / Otm At Af Stn Kanheri Hills Under Ge Af Thane

Issued by Statutory Bodies & Commissions/Committees · Thane, Maharashtra
Tender Value
44 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
7 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Wiring At Certain Otm Bldg And Roof Treatment At Certain Md Accn / Otm At Af Stn Kanheri Hills Under Ge Af Thane

BOQ

Name of Work:- SPECIAL REPAIR TO WIRING AT CERTAIN OTM BLDG AND ROOF TREATMENT AT CERTAIN MD ACCN / OTM AT AF STN KANHERI HILLS UNDER GE AF THANE
Sl. No. Item Description
1Removing existing water proofing treatment where so ever exist (except concretepadding) and removing debris/rubbish off the site complete all as specified and directed by Engr-in-Charge.
2Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and directed by Engr-in-Charge. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place
3M&L for providing PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and directed by Engr-in-Charge. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after
4M&L for 10 mm thick plaster in roof surface in CM 1:3 mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and directed by Engr-in-Charge.
5Supply only Liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
6Material and labour for water proofing treatment with APP based standard membrane over in roof with the following courses of treatment for:-(a) Apply bituminous primer (IS 3384) @ 0.40 Ltr per sqm of the surface area including cleaning the surfaces complete all as specified and directed by Engr-in-Charge. (b) Applying APP based polymeric membrane, minimum weighing 3Kg/Sqm and minimum 3mm thick, over a coat hot blown bitumen grade (30/40) applied @ 1.20 kg/Sqm with side overlap of membrane shall be minimum 75mm and end overlap shall be 100mm and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified and directed by Engr-in-Charge. (c) The entire surface of finished APP membrane shall finally be painted with two coat of Solar reflective bituminous aluminium paint @ 0.1 ltr per Square Meter and other as prescribed by manufacturer ,complete all as specified and as directed by Engr-in-charge
7Fixing only, after cleaning old steel water tubing, 20mm bore and connections in new or old position using new fittings complete all as specified and directed by Engr-in-Charge.
8Taking up or down existing steel water tubing, 25mm bore alongwith connections fixed/laid in any situation complete all as specified and directed by Engr-in-Charge.
9Fixing only, after cleaning old steel water tubing, 25mm bore and connections in new or old position using new fittings complete all as specified and directed by Engr-in-Charge.
10S&F Galvanised iron steel water tubing, 25mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed by Engr-in-Charge.
11S&F in repair 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge.
12Disconnecting existing tanks, of capacity exc 500 ltr but n. exc 1000 ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
13Dismantling water tank capacity exc 500 and n exc 1000 ltr and removing to store complete all as specified and directed by Engr-in-Charge.
14S&F1000 Ltr Rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
15S&F in repair 20mm Ball valves, high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms complete all as specified and directed by Engr-in-Charge.
16Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and making good disturbed surfaces of walls, floors etc to match with existing surfaces of colour shade complete all as specified and directed by Engr-in-Charge.
17Material and labour for Point wiring with 1.5 sqmm copper conductor single core core , cable (multistrand) PVC insulated FRLS(unsheathed) concealed drawing in existing PVC conduit/casing caping 25 mm dia, having wall thickness not less than 2 mm for one light pont, controlled by one , one way switch , including 1.5 sqmm PVC insulated FRLS (unsheathed ) copper conductor continuous earth wire all as specified and directed by Engr-in-Charge.
18All as per item No 17 above, but for One fan point controlled by one switch completed all as specified and directed by Engr-in-Charge.
19All as per item No 17 above, but for One 3 pin 6 amps socket out let point controlled by one 6 amps switch on independent board complete all as specified and directed by Engr-in-Charge.
20All as per item No 17 above, but for One 3 pin 6 amps socket point controlled by one 6 amps switch on same board complete all as specified and directed by Engr-in-Charge.
21All as per item No 17 above, but with 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switch on on Ind board complete all as specified and directed by Engr-in-Charge.
22Supplying and fixing following modular 6 A switch on the existing modular plate & switch box including connections but excluding modular plate etc complete all as specified and directed by Engr-in-Charge.
23Supplying and fixing following modular 16 A switchon the existing modular plate & switch box including connections but excluding modular plate etc complete all as specified and directed by Engr-in-Charge.
24Supplying and fixing following modular 6 A socket on the existing modular plate & switch box including connections but excluding modular plate etc complete all as specified and directed by Engr-in-Charge.
25Supplying and fixing following modular 16 A socket on the existing modular plate & switch box including connections but excluding modular plate etc complete all as specified and directed by Engr-in-Charge.
26Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding complete all as specified and directed by Engr-in-Charge.
27Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc complete all as specified and directed by Engr-in-Charge.
28Supplying and fixing following modular 6 A Bell push on the existing modular plate & switch box including connections but excluding modular plate etc complete all as specified and directed by Engr-in-Charge.
29Supplying and fixing call bell/ buzzer suitable for single phase, 230 V complete all as specified and directed by Engr-in-Charge.
30Supplying and fixing 1 or 2 module, GI box along with modular base & cover plate for modular switches in recess etc complete all as specified and directed by Engr-in-Charge.
31Supplying and fixing 3 module, GI box along with modular base & cover plate for modular switches in recess etc complete all as specified and directed by Engr-in-Charge.
32Supplying and fixing 4 module, GI box along with modular base & cover plate for modular switches in recess etc complete all as specified and directed by Engr-in-Charge.
33Supply and Fixing 8 module, GI box alongwith modular base & cover plate for modular switches in ecess etc complete all as specified and directed by Engr-in-Charge.
34Material and labour for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed.Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit complete all as specified and directed by Engr-in-Charge.
35Supply & fix in repair LED lights 1x20 watt ,220 V, AC decorative box type with driver , holder including LED tube light connecteing up with three core flexible copper conductor cable of suitable size from ceiling rose including connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed by Engr-in-Charge.
36Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
37Supply and fix in repair LED Bldg security light fitting 35 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish.prismatic polycarbonate cover with individual LED lenses with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete all as specified and directed by Engr-in-Charge.
38Supply and Fixing in repair recess mounting high lumen LED flat panel 2'x2' 36 Watt, slim fit white powder coated CRCA housing with highpower LEDs aluminium front frame with flat white high transmission acrylic cover, internally prewired 230 V complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all connnected accessories all as specified and directed by Engr-in-Charge.
39Supply and fix in repair recess/surface mounting light fittings and supply and fix new LED 15 watt surface mounting light fitting LED backlit round or square (as reqd at site) down lighter with high effcient LEDs & glare free opal diffuser IP20, internally prewired, 230V, complete with all accessories such as electronic driver, connector block etc.and necessary fixing arrangement at any height and removing old unserviceable item with all connected accessories complete all as specified and directed by Engr-in-Charge.
40Supply and fix exhaust fan, steel body AC Single Phase.230V of size 300 MM sweep with, blades,andframeand louvers includingremoving of existing complete all as specified and directed by Engr-in-Charge.
41Supply and fix in repairs MCB distribution board SPN 8 way 240 volts, double door with IP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete and making good the disturbed surfaces to match with existing complete all as specified and directed by Engr-in-Charge.
42Supply and fix in repairs MCB distribution board SPN 4 way 240 volts, double door with IP 42 protection duly painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN as incomer and MCB SP/DP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gland plate including removing old unserviceable item complete and making good the disturbed surfaces to match with existing complete all as specified and directed by Engr-in-Charge.
43Supply and fix in repair MCB SP 6 to 32 Amps,10 KA, \\"C\\" series, 240 volts complete all as specified and directed by Engr-in-Charge.
44Supply & fix in repair MCB SPN 40 Amps 10 KA, \\"C\\" series, 240 volts complete all as specified and directed by Engr-in-Charge.
45Supply and fix in repair, factory made, sheet metal enclosure, double door, 415 volts, AC,TPN, vertical distribution board, 4 way, painted with epoxy based powder coated suitable for mounting MCCB as incomer of rating upto 160Amps, FP, 16-36 KA and MCB SP /TP as outgoings and complete with and including 200 amps rated copper busbar, neutral bar,earth bar, connecting cable links with and including top and bottom removable gland plate, complete with IP 43 protection, and making good the disturbed surfaces to match with existing complete all as specified and directed by Engr-in-Charge.
46Supply & fix in repair MCCB FP 63 Amps,16 KA, 415 volts complete all as specified and directed by Engr-in-Charge.
47Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified and directed by Engr-in-Charge.
48Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required and providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.(7.5 Mtr) (For High Mast) complete all as specified and directed by Engr-in-Charge.
49Supply,lay and testing in replacement LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 35 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed by Engr-in-Charge.
50Supply,lay and testing in replacement LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 50 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed by Engr-in-Charge.
51Supply,lay and testing in replacement LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 95 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed by Engr-in-Charge.
52Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed by Engr-in-Charge.
53Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed by Engr-in-Charge.
54Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
55Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose complete all as specified and directed by Engr-in-Charge.
56Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm complet all as specified and directed by Engr-in-Charge.
57Supply and lay GI pipe 50mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables including removing old unserviceable item as required complete all as specified and directed by Engr-in-Charge.
58Supply and lay GI pipe 80mm dia light grade in any length with all GI fittings such as socket, elbow, bend, union, Tee etc laid in trenches/duct/culvert/road crossing etc for protection of cables including removing old unserviceable item ccomplete all as specified and directed by Engr-In-Charge. Make for I No 32 & 33 :- Jindal/Tata/BST
59Supply & fix in repair including, installation, testing and commissioning of totally enclosed LT electric panel outdoor type (IP-55) fabicrated out of 3.15mm thick CRCA, CPRI approved sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each ACB/MCCBs, bus bar chamber enclosed complete suitable for operating on 415 volt 50 Hz AC supply internally wired with copper conductor/strip of adequate size from main incoming MCCB to bus bar and bus bar to outgoing MCCB/MCBs having legs 45cm made out of 65x65x6mm angle iron grouted on brick masonary platfor upto 30 Cm. Brick masonary platform should be 60Cm above the ground level, comprising the following:- (a) MCCB 250 Amps,FP, 36 KA,415 volts,50Hz-02 No (b) MCCB 125 Amps,FP,16 KA,415 volts,50Hz-2Nos (c) MCCB FP 40 to 100 AMPs-4 Nos (d) Digital voltmeter,with VSS -01 set,Digital, Ammeter,with CTs & ASS-01 set (e) LED phase indication lamps RYB-01 set (f) Aluminium bus bar TPN 400 Amps rating -01 set complete all as specified and directed by Engr-In-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57954612
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44 Lakhs
LAST DATE 28-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Wiring At Certain Otm Bldg And Roof Treatment At Certain Md Accn / Otm At Af Stn Kanheri Hills Under Ge Af Thane
Basic Detail
Tender No GE (AF) T-66 OF 2026-27 (8683)
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 09 Oct 2026
Submission Date 28 Oct 2026
Open Date 04 Nov 2026
Finance
Tender Value 44 Lakhs
Tender Fee 500
EMD 88000
Exemption Available
Document List
BOQ_889440.xls
de3ccbe1-dd1d-4408-88c7-ef1e234a48a9.html
TD8683.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_889440.xls

html

de3ccbe1-dd1d-4408-88c7-ef1e234a48a9.html

pdf

TD8683.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender