Road Transport and Highways Government Departments Closing in 20 days TDR #57952197

Tender For Supply, Installation, Testing And Commissioning Of Street Light Poles And High Mast Tower At Okhla Depot (Cws-Ii).

Issued by Government Departments · Delhi, Delhi
Tender Value
79.64 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
20 days left
EMD
1.59 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing And Commissioning Of Street Light Poles And High Mast Tower At Okhla Depot (Cws-Ii).

BOQ

Name of Work:- Supply, Installation, Testing and Commissioning of street light poles and high mast tower at Okhla Depot (CWS-II).
Sl. No. Item Description
1Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
22 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
3Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
4Single pole
5Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
7Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
8Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
9Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
10Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
11Upto 35 sq. mm
12Above 35 sq. mm and upto 95 sq. Mm
13Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
14Upto 35 sq. mm (clamped with 1mm thick saddle)
15Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
16Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on,bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
17Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
184 X 25 sq. mm (28mm)
194 X 50 sq. mm (35mm)
20Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
2163 mm dia (OD-63 mm & ID-51 mm nominal)
2290 mm dia (OD-90 mm & ID-76 mm nominal)
23120 mm dia (OD-120 mm & ID-103 mm nominal)
24Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration tobe mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sunset & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hourdisplay format with suitable battery and indication for relay status i/c programming at site complete as required.
253 output(1output per phase) and suitable for threephase supply
26LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
27150 watt
28LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
29250 watt
30Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
31All kinds of soil.
32Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil
33Pipes, cables etc, not exceeding 80 mm dia.
34Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
35Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
361:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
371:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
38Centering and shuttering including strutting, propping etc. and removal of form for
39Foundations, footings, bases of columns, etc. for mass concrete
40Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
41Thermo-Mechanically Treated bars of grade Fe-500D or more.
42Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level
43Concrete of M25 grade with minimum cement content of 330 kg /cum
44Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
45Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
46Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
47Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
48Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x25 Sq. mm.
49Supply of XLPE insulated PVC Sheathed Armoured Aluminium Conductor cable 1.1KV Grade Conforming to IS-7098 of size 4x50Sq. mm.
50S/I/T/C of 7 mtr high hot dip galvanised octagonal poles with 130mm bottom A/F & 70mm top A/F made up of 3mm thk. HR sheet alongwith base plate of size 220X220X12mm thk., Foundation Accessories including foundation J Bolts , Single Arm Bracket 1 Mtr
51Supply of multi strand PVC insulated & PVC Sheathed annealed bare copper conductor multicore round flexible industrial cables for working voltage upto 100V confirming to IS 694: 2010 of size 3x2.5Sq. mm.
52SITC of Feeder Pillar Panel for 16 Mtr Motorized High Mast including1. 32A 4P MCCB- 1 Nos2. 32A Contactor- 1Nos3. 9A Contactor- 2 Nos4. Digital Timer- 1 Nos5. Push Button- 2 Nos6. Indicator Light- 3 Nos7. Connector 4 way- 2 Nos
53SITC of Feeder Pillar Panel for street lights including 1. TPN 32A 4P MCCB- 1 Nos2. Contactor 32A - 1 Nos3. Timer- 1 Nos4. Auto Manual- 1 Nos5. Light- 3 Nos6. Connector 4way- 2 Nos
54S/I/T/C of 16 M high mast shaft in Two sections suitable for wind speed as per IS: 875 part-III, with head frame, winch mounting bracket, luminariescarriage suitable to install 8-12nos Flood light luminaries in symmetrical arrangement.Supply of raising lowering system comprisin double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial. Including Counter weight.(Wiring material from JB to individual luminaire & MCB in base compartment are not included and are a part of installation).S/I/T/C of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template.
55S/I/T/C of LED type Single dome aviation obstruction light.
56Less correction factor on DSR-2023 on account of [email protected]
57Add @ 4.03% cost index on DSR 2023 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57952197
AUTHORITY Government Departments
TENDER VALUE 79.64 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Delhi Transport Corporation
Work Description Tender for Supply, Installation, Testing And Commissioning Of Street Light Poles And High Mast Tower At Okhla Depot (Cws-Ii).
Basic Detail
Tender No Dy.CGM(Civil)/CED/Elect. /2026-27/09
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 09 Oct 2026
Submission Date 30 Oct 2026
Open Date 30 Oct 2026
Finance
Tender Value 79.64 Lakhs
Tender Fee Ref. Documents
EMD 1.59 Lakhs
Exemption Not Available
Document List
4ca042a5-33a8-4cef-bf69-f31b5b226b8b.html
BOQ_400041.xls
tenderdocumentDTC.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days