Youth Affairs and Sports and Culture Government Departments Closing in 7 days TDR #57951836

Tender For Purchase Of Wireless Biomechanical Measurement And Rehabilitation System At G V Raja Sports School

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Oct 2026
7 days left
EMD
18000
Bank guarantee accepted
Document Fee
1800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Purchase Of Wireless Biomechanical Measurement And Rehabilitation System At G V Raja Sports School , Wireless Biomechanical Measurement , 1 Purchase Of Wireless Biomechanical Measurement & Rehabilitation System At G.V Raja Sports School • Hand Grip Strength Sensor  Measures Peak And Average Isometric Grip Strength.  Max Force: ≥90 Kg, Accuracy: ±0.1 Kg Or Better.  Sampling Frequency: 1000 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥40 M. • Handheld Push Dynamometer  For Isometric Strength Testing Of Major Muscle Groups.  Max Force: ≥90 Kg, Accuracy: ±0.1 Kg Or Better.  Sampling Frequency: 1000 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥40 M. • Pull Dynamometer  For Fixed-Position Or Chain-Based Strength Assessment.  Max Force: ≥300 Kg, Accuracy: Class C3 (0.1%).  Frequency: 1000 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥40 M. • Pneumatic Pressure Sensor (Bubble Type)  Measures Pressure Variations During Pneumatic Or Inflatable Exercises.  Max Pressure: 0.4 Bar (5.8 Psi), Accuracy: 1.5%.  Frequency: ≥100 Hz.  Compact, Disinfectable Housing Suitable For Clinical Use. • Digital Goniometer / Motion Sensor  Measures Joint Range Of Motion (Rom) Using Inertial Measurement (Imu).  Static Accuracy: ±2°, Dynamic Accuracy: ±7°.  Sampling Frequency: ≥400 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥50 M. • Force Plates (Basic)  Dual-Plate Design For Balance, Stability, And Jump Testing.  Max Load: ≥600 Kg Per Plate, Accuracy: ±0.1 Kg.  Frequency: ≥1000 Hz.  Battery Life: ≥20 Hours, Wireless Range: ≥20 M. General Technical & Safety Requirements  Auto Sleep After 10 Minutes Of Inactivity.  Rechargeable Li-Po Batteries With Medical-Grade Usb Charger.  Easy Disinfection Using 70% Alcohol Wipes.  Fully Wireless And Portable System For Lab Or Field Use.  Compliant With The Following Standards:  Iec 60601-1 (Medical Electrical Equipment Safety)  Ce / Fcc Certification  Iso 15223, Weee, Rohs Compliance Additional Requirements  Should Include Centralized Software For All Sensors Under A Single Application.  The Software Should Allow Customized Testing Protocols, Real-Time Data Visualization, And Athlete Performance Reporting.  Cloud-Based Account Management And Multi-Device Data Sync Support.  Multi-Sensor Analytics Dashboard For Team Or Institutional Monitoring. Additional Components • Grip Accessory (Size L)  Ergonomic Detachable Accessory For Hand Grip Strength Devices.  Designed For Larger Hand Sizes To Ensure Standardized Positioning And Comfort During Repeated Trials.  Durable, Washable, And Disinfectable Material Suitable For Clinical And Sports Settings.  Compatible With The SystemS Wireless Grip Strength Sensor.  Reusable And Compliant With Medical Hygiene Standards (Iso 15223, Rohs). 1

BOQ

Name of Work:- Purchase of Wireless biomechanical Measurement and Rehabilitation System at G V Raja Sports School
Sl. No. Item Description
1Wireless biomechanical Measurement
21 Purchase of Wireless biomechanical measurement & Rehabilitation system at G.V Raja Sports School • Hand Grip Strength Sensor Measures peak and average isometric grip strength. Max Force: ≥90 kg, Accuracy: ±0.1 kg or better. Sampling Frequency: 1000 Hz. Battery Life: ≥12 hours, Wireless Range: ≥40 m.• Handheld Push Dynamometer For isometric strength testing of major muscle groups. Max Force: ≥90 kg, Accuracy: ±0.1 kg or better. Sampling Frequency: 1000 Hz. Battery Life: ≥12 hours, Wireless Range: ≥40 m.• Pull Dynamometer For fixed-position or chain-based strength assessment. Max Force: ≥300 kg, Accuracy: Class C3 (<0.1%). Frequency: 1000 Hz. Battery Life: ≥12 hours, Wireless Range: ≥40 m.• Pneumatic Pressure Sensor (Bubble Type) Measures pressure variations during pneumatic or inflatable exercises. Max Pressure: 0.4 bar (5.8 psi), Accuracy: <1.5%. Frequency: ≥100 Hz. Compact, disinfectable housing suitable for clinical use.• Digital Goniometer / Motion Sensor Measures joint range of motion (ROM) using inertial measurement (IMU). Static Accuracy: ±2°, Dynamic Accuracy: ±7°. Sampling Frequency: ≥400 Hz. Battery Life: ≥12 hours, Wireless Range: ≥50 m.• Force Plates (Basic) Dual-plate design for balance, stability, and jump testing. Max Load: ≥600 kg per plate, Accuracy: ±0.1 kg. Frequency: ≥1000 Hz. Battery Life: ≥20 hours, Wireless Range: ≥20 m.General Technical & Safety Requirements Auto sleep after 10 minutes of inactivity. Rechargeable Li-Po batteries with medical-grade USB charger. Easy disinfection using 70% alcohol wipes. Fully wireless and portable system for lab or field use. Compliant with the following standards: IEC 60601-1 (Medical electrical equipment safety) CE / FCC certification ISO 15223, WEEE, RoHS complianceAdditional Requirements Should include centralized software for all sensors under a single application. The software should allow customized testing protocols, real-time data visualization, and athlete performance reporting. Cloud-based account management and multi-device data sync support. Multi-sensor analytics dashboard for team or institutional monitoring.Additional Components • Grip Accessory (Size L) Ergonomic detachable accessory for hand grip strength devices. Designed for larger hand sizes to ensure standardized positioning and comfort during repeated trials. Durable, washable, and disinfectable material suitable for clinical and sports settings. Compatible with the system’s wireless grip strength sensor. Reusable and compliant with medical hygiene standards (ISO 15223, RoHS). 1 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57951836
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 23-10-2026
Authority
Authority Name Directorate Of Sports And Youth Affairs
Work Description Tender for Purchase Of Wireless Biomechanical Measurement And Rehabilitation System At G V Raja Sports School , Wireless Biomechanical Measurement , 1 Purchase Of Wireless Biomechanical Measurement & Rehabilitation System At G.V Raja Sports School • Hand Grip Strength Sensor  Measures Peak And Average Isometric Grip Strength.  Max Force: ≥90 Kg, Accuracy: ±0.1 Kg Or Better.  Sampling Frequency: 1000 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥40 M. • Handheld Push Dynamometer  For Isometric Strength Testing Of Major Muscle Groups.  Max Force: ≥90 Kg, Accuracy: ±0.1 Kg Or Better.  Sampling Frequency: 1000 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥40 M. • Pull Dynamometer  For Fixed-Position Or Chain-Based Strength Assessment.  Max Force: ≥300 Kg, Accuracy: Class C3 (0.1%).  Frequency: 1000 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥40 M. • Pneumatic Pressure Sensor (Bubble Type)  Measures Pressure Variations During Pneumatic Or Inflatable Exercises.  Max Pressure: 0.4 Bar (5.8 Psi), Accuracy: 1.5%.  Frequency: ≥100 Hz.  Compact, Disinfectable Housing Suitable For Clinical Use. • Digital Goniometer / Motion Sensor  Measures Joint Range Of Motion (Rom) Using Inertial Measurement (Imu).  Static Accuracy: ±2°, Dynamic Accuracy: ±7°.  Sampling Frequency: ≥400 Hz.  Battery Life: ≥12 Hours, Wireless Range: ≥50 M. • Force Plates (Basic)  Dual-Plate Design For Balance, Stability, And Jump Testing.  Max Load: ≥600 Kg Per Plate, Accuracy: ±0.1 Kg.  Frequency: ≥1000 Hz.  Battery Life: ≥20 Hours, Wireless Range: ≥20 M. General Technical & Safety Requirements  Auto Sleep After 10 Minutes Of Inactivity.  Rechargeable Li-Po Batteries With Medical-Grade Usb Charger.  Easy Disinfection Using 70% Alcohol Wipes.  Fully Wireless And Portable System For Lab Or Field Use.  Compliant With The Following Standards:  Iec 60601-1 (Medical Electrical Equipment Safety)  Ce / Fcc Certification  Iso 15223, Weee, Rohs Compliance Additional Requirements  Should Include Centralized Software For All Sensors Under A Single Application.  The Software Should Allow Customized Testing Protocols, Real-Time Data Visualization, And Athlete Performance Reporting.  Cloud-Based Account Management And Multi-Device Data Sync Support.  Multi-Sensor Analytics Dashboard For Team Or Institutional Monitoring. Additional Components • Grip Accessory (Size L)  Ergonomic Detachable Accessory For Hand Grip Strength Devices.  Designed For Larger Hand Sizes To Ensure Standardized Positioning And Comfort During Repeated Trials.  Durable, Washable, And Disinfectable Material Suitable For Clinical And Sports Settings.  Compatible With The SystemS Wireless Grip Strength Sensor.  Reusable And Compliant With Medical Hygiene Standards (Iso 15223, Rohs). 1
Basic Detail
Tender No 24/DSYA/2026-27
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 09 Oct 2026
Submission Date 23 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 1800
EMD 18000
Exemption Available
Document List
a3fcf26b-41eb-42f7-b6e1-49cbdc519a90.html
BOQ_1491971.xls
Tendernotice_1.pdf
Wirelessbiomechanical.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

a3fcf26b-41eb-42f7-b6e1-49cbdc519a90.html

xls

BOQ_1491971.xls

pdf

Tendernotice_1.pdf

pdf

Wirelessbiomechanical.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender