Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #57951443

Tender For Provn Of Generator Set At Tapovan Alongwith Special Repair To Capacitor Bank, Lt Poles, Solar Security Lights And Allied Works At Jpshimath Under Ge 871 Ews.

Issued by Statutory Bodies & Commissions/Committees · Chamoli, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Nov 2026
4 days left
EMD
73000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Generator Set At Tapovan Alongwith Special Repair To Capacitor Bank, Lt Poles, Solar Security Lights And Allied Works At Jpshimath Under Ge 871 Ews.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-Nov-2026

BOQ

Name of Work:- PROVN OF GENERATOR SET AT TAPOVAN ALONGWITH SPECIAL REPAIR TO CAPACITOR BANK, LT POLES, SOLAR SECURITY LIGHTS AND ALLIED WORKS AT JPSHIMATH UNDER GE 871 EWS.
Sl. No. Item Description
1SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS.
2Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating Set of capacity 15 KVA, Three Phase, 0.8 Power Factor, 50Hz, 415 Volts, speed 1500 RPM, self elicited, self regulated brushless AC generator mounted on common base plate with flexible coupling and meeting the requirement latest IS/BIS specifications conforming to conditions under ‘CPCB IV+ emission regulation’, ISO 8528-1, 3046, IS: 10002, BS- 5514/5000 and suitable for ambient conditions at Joshimath with derating factor, having capacity 10% overloading for one hour in every twelve hour duration. The DG set shall be having NAL approved acoustic enclosure, plain cement concrete platform, mild steel channel for mounting DG set with rubber pads and AMF panel, complete all as specified and directed. Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 24 of tender (CA) here-in-after.
3Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed.Note: Detailed descriptions of item shallEarth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
4Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation, etc. or for laying of cables, etc. not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, any type of soil, complete all as specified and as directed.
5Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, any type of soil, complete all as specified and as directed.
6Removing excavated soil not exceeding 50mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point, complete all as specified and as directed.
7Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured.
8Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed.
9Replacement of old unserviceable/ damaged cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
10Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, size not less than 1250mmx1000mmx600mm, outdoor, cubical type, floor mounted, factory made, CPRI approved, fabricated out of 3.15mm thick, epoxy powder coated, mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm, 60Cm above from the ground level duly supported with mild steel angle iron 40x40x6mm legs, embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) 300mm below the ground level and required masonry in brick work in cement mortar 1:6, 300mm above ground level, LT feeder pillar box shall be totally enclosed weather proof and vermin proof with front and rear openable door shutter with locking arrangements, with IP-54 protection as per IS-8623 duly powder coated, for three phase, 415 Volts, AC, 4-wire, 50 Hz, having triple pole and neutral, aluminium bus bars of 200 Amps rating duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire up to copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/ gland complete all as specified and directed.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 26 of tender (CA) here-in-after.
11Double wall corrugated HDPE pipe, orange colour, ISI marked, nominal size 90mm dia with 75mm inner dia, conforming to IS: 16205 Part-24, including connecting accessories i.e couplers, connectors, bends, sockets, for protection of electric cable, laying in trenches, duct or fixed to walls/ poles as required, complete all as specified and as directed.Make: Prince/ Finolex/ Astral/ RC Plasto/ Supreme.
12Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
13Steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed to view entire surface and two coats of bituminous paint on embedded portion, making three Nos circular strips, each 100mm wide with one No of yellow colour in middle and two Nos of black in colour, endorsing pole number with black paint on yellow strip, complete all as specified and as directed.Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
14Excavation in trenches, not exceeding 1.50mtr wide and not exceeding 1.50mtr in depth; for foundation of poles or laying of cables, etc., not exceeding 10 Sqm on plan and getting out in any type hard rock, complete all as specified and as directed.Note: Stone retrieved from excavation shall be issued to contractor.
15Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed.
16Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, or in foundation of poles and stays, complete all as specified and as directed.
17Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of pole's foundation including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed.
18Supply, installation, testing and commissioning of 100 KVAR APFC panel ‘KIOSK TYPE’ cubical shape, weather, dust and vermin proof (outdoor type) CPRI approved factory made suitable for operation on 1100 Volts, Three phase, 4-wire, 50 Hz, AC electric supply, externally powder coated and internally painted with two coats of synthetic enamel paint over one coat of red oxide primer on prepared surfaces, complete panel made with 3.15mmm thick CRCA mild steel sheet, size as required to compersing all the required accessories, having openable shutter with locking arrangements at front and back side including cable tray of size not less than 20Cm in width, also having copper bus bars of 25mmx6mm size, complete panel mounted on angle iron size 50mmx50mmx6mm having legs of 1000mm including fixing in Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), as mass concrete in foundation depth of 500mm and having 500mm above ground level, complete all as specified and as directed.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 26-27 of tender (CA) here-in-after.
19Supply, installation, testing and commissioning of 200 KVAR APFC panel ‘KIOSK TYPE’ cubical shape, weather, dust and vermin proof (outdoor type) CPRI approved factory made suitable for operation on 1100 Volts, Three phase, 4-wire, 50 Hz, AC electric supply, externally powder coated and internally painted with two coats of synthetic enamel paint over one coat of red oxide primer on prepared surfaces, complete panel made with 3.15mmm thick CRCA mild steel sheet, size as required to compersing all the required accessories, having openable shutter with locking arrangements at front and back side including cable tray of size not less than 20Cm in width, also having copper bus bars of 25mmx6mm size, complete panel mounted on angle iron size 50mmx50mmx6mm having legs of 1000mm including fixing in Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), as mass concrete in foundation depth of 500mm and having 500mm above ground level, complete all as specified and as directed.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 27-28 of tender (CA) here-in-after.
20LED street light fitting 65 Watt 230 Volt, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, connecting up with three core flexible copper conductor cable of suitable size, and including house service bracket for mounting light fittings. House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.Make: Havells cat part No- ENDURASUNBEAMGENXSL60WLED757SASYBOPC or equivalent in Phillips/ Bajaj/ Crompton.
21Supply and fixing, Lithium based Energy efficient integrated Solar Street light, capacity 50 Watt, in Single FRP body with duly polyurethane coating encases with Monocrystalline Solar PV Panel of 90/ 95 Wp, Lithium Battery 11.10/ 12.80 Volts, 43.5 Ah with inbuilt BMS, IP-65, High brightness W-LED (160-180 lumens/ Watt) lamp with Aluminium reflector for better light distribution, CRI>70, Colour Temperature 57000K to 6500K, Microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness and rest of the time at lower light level with PIR motion sensor), Dusk to Dawn Operation, suitable to working temperature (-)10℃ to (+) 55 ℃, weight not more than 80-20 Kg including fixing on medium grade Galvanised Iron pipe pole of 80mm bore, 7.00mtrs long swaged type including painting with two coat of aluminium paint over one coat of red oxide primer on all exposed to view surfaces and tarring with black bituminous paint to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black and white paint starting from plinth level at an interval of 30 Cm in between 2-bands and numbering of poles, in white paint over black painted back ground at a height of 2.00mtrs from top of coping of the pole with 5 Cm large bold letters 2”(inch) wide, pole having with mild steel base plate of size 300mmx300mmx6mm thick fixed at bottom to poles, with final taper plug, suitable adjustable mild steel clamps, bolts, nuts and washers suitable for pole mounting the light fitting with batteries etc complete all as required and all as specified. Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 28 of tender (CA) here-in-after.
22Arial bunched cable, 1100 Volts, nominal cross sectional area 25.0 Sqmm, consisting four single core (Three Phase and one Neutral), sizes 4x25Sqmm+16Sqmm, each core screened by an extruded, semi-conducting cable, XLPE insulated and screened again by semi-conducting layer and aluminium tape and XLPE insulation, phase identification tape, twisted around one insulated messenger of 16.0 Sqmm as mention here-in-before, messenger will made out of aluminium and mild steel alloy and over all PVC or polythene sheathed, stretching the cable on existing poles with mild steel anchor clamps, suspension, clamps, hooks, nuts, bolts and washers including cable ends/ straight through joints (in-line connectors), tee junctions as required at site, complete all as specified and as directed.Make: Havells/ Poycab/ Finolex/ Paragon/ seewel.
23Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, size not less than 1200mmx1200mmx350mm, outdoor, cubical type, floor mounted, factory made, CPRI approved, fabricated out of 3.15mm thick, epoxy powder coated, mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm, 60Cm above from the ground level duly supported with mild steel angle iron 40x40x6mm legs, embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) 500mm below the ground level and required masonry in brick work in cement mortar 1:6, 1.0mtr above ground level, LT feeder pillar box shall be totally enclosed weather proof and vermin proof with front and rear openable door shutter with locking arrangements, with IP-54 protection as per IS-8623 duly powder coated, for three phase, 440 Volts, AC, 4-wire, 50 Hz, having triple pole and neutral, copper bus bars of 400 Amps rating duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire up to copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/ gland complete all as specified and directed.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 28 of tender (CA) here-in-after.
24Supply, installation, testing and commissioning of electric LT Feeder Pillar Box, size not less than 1200mmx1200mmx350mm, outdoor, cubical type, floor mounted, factory made, CPRI approved, fabricated out of 3.15mm thick, epoxy powder coated, mild steel sheet mounted on frame of mild steel angle iron 40x40x6mm, 60Cm above from the ground level duly supported with mild steel angle iron 40x40x6mm legs, embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) 500mm below the ground level and required masonry in brick work in cement mortar 1:6, 1.0mtr above ground level, LT feeder pillar box shall be totally enclosed weather proof and vermin proof with front and rear openable door shutter with locking arrangements, with IP-54 protection as per IS-8623 duly powder coated, for three phase, 440 Volts, AC, 4-wire, 50 Hz, having triple pole and neutral, copper bus bars of 250 Amps rating duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire up to copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/ gland complete all as specified and directed.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 29 of tender (CA) here-in-after.
25Factory made junction box, made with thermo polycarbonate, weather, water and vermin proof, dust proof, for outdoor use, having internal dimensions 200mmx150mmx75mm, suitable for road/ street lighting for 3-phase/ 4-core high wattage LED based lighting system for industrial applications, suitable for pole mounting, including 01 No. MCB single pole, 6 Amps and 03 Nos. aluminium bus bars of 100 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections along with locking arrangement, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing/ mounting on poles, painted with two coats of synthetic enamel paint over one coat of primer on internal and external surfaces, fixing in repairs, complete all as specified and directed.
26Supply, installation, testing and commissioning of automatic street light switch with new Automatic Street light switch of capacity 8.0 KW in three phase using infrared sensor based nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete accessories as under including taking down old street light switch, complete all as specified and as directed. (i) Contactor rating (AC3) single phase, 50-63 Amp.Make : BCH/ L&T/ Schneider.(ii) MCB 63 Amps, Single Pole,10 KA, 240 Volts.(iii) NATURE Switch -01 No.
27Amount of Schedule of credit as mentioned here-in-after shall be deducted from quoted amount. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57951443
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 06-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Generator Set At Tapovan Alongwith Special Repair To Capacitor Bank, Lt Poles, Solar Security Lights And Allied Works At Jpshimath Under Ge 871 Ews.
Basic Detail
Tender No 8155/E8
Bidding Type Tender
Location
City Chamoli
State Uttarakhand
Key Dates
Publish Date 30 Oct 2026
Submission Date 06 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 73000
Exemption Available
Document List
76198122-32ce-48eb-82bb-3a6cdbd5fd66.html
BOQ_889394.xls
E-Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 06, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

76198122-32ce-48eb-82bb-3a6cdbd5fd66.html

xls

BOQ_889394.xls

pdf

E-Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender