Youth Affairs and Sports and Culture Government Departments Closing in 13 days TDR #57951001

Tender For Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Oct 2026
13 days left
EMD
50000
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center , Portable Ultrasound Machine , Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center - 1 Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center • Should Be A Diagnostic Musculoskeletal Ultrasound Machine • Complete With Preset & Measurement For Sports Medicine Application, Musculoskeletal Imaging, General Imaging, Vascular Small Parts, Thyroid, And Ceus With Quantification Tool Fully Integrated In Main Unit To Measure Wi/ Wo Curves And Intensity Against Time Packages. • System Should Be Of Latest Technology With Windows 10 Os Or Better Based Platform • Rotatable Keyboard With Height Adjustment, Should Include Alphanumeric Keyboard With Min 10 Colour Lcd Touch Screen For Accession Functions • Tiltable 15 Or Higher Medical Grade Display Monitor With Articulating Arm • Should Have 3 Active Pin Less Probes Connectors • Should Have 2D Frame Rate Of Minimum 800 Or Higher Frames Per Sec • Should Have Colourdoppler Frame Rate Of 300 Hz Or More • Should Have Minimum 256 Or Higher Gray Levels • Should Have Dynamic Range Of 350Db Or Higher • Archiving Capabilities With Sorting Of Clips And Still Images In Ssd Storage • Internal Ssd Storage With Minimum Of 128 Gb Or Higher • B-Mode/ Dual -B Mode/ M-Mode • Pw/ Hprf Doppler • Colour Doppler And Power Doppler • Speckle Reduction Software • Should Have Post Processing From Stored Data • Should Have Follow-Up Option For Comparison Of Post And Pre Surgery With Different Modality Like Mri/ Ct Or Same Modality • Speed Of Sound Regulation- Possibility To Modify The Speed Of Value In Order To Focalization On The Lateral Direction • Should Have Panoramic Imaging Of Minimum 60 Cm Or Higher With Cfm • Ultra Sensitivity Colour Doppler To Pick Up Small Vessels And Slow Flow Detections • Unlimited Users Preset For All Applications • System Imaging Capable From 1 To Min 22Mhz Or Higher Frequency For Superficial Imaging Applications • Should Have Radio Frequency Based Intima Media Thickness Measurement • Should Have Radio Frequency Based Arterial Stiffness Measurements • Should Have Strain Based Elastography In Linear Array & Convex Array Probes • Should Have Quantification Tools Fully Loaded In Ultrasound For Contrast Study Imaging With Intensity Curves • Should Have Option To Upgrade To 2D Shear-Wave Elastography In Convex Probes • Should Supply A Colour Ink - Jet Printer • Should Have Dicom, Usb, Hdmi Output In Main Unit • System Should Have Ce And Us-Fda Certification • Standard Transducer To Be Offered And The Rate Shall Be Quoted Separately Which Will Be Considered For L1 Evalution. A) Convex Array Transducer With Bandwidth Frequency Of (1.0 To 8.0 Mhz) With General Imaging Application With Min 44Cm Depth Or Higher With Strain Based Elastography Imaging B) L-Shape Linear Array Transducer With Bandwidth Frequency Of (6.0 To 18.0 Mhz) For Vascular Access, Small Parts, Msk & Sports Medicine Imaging Application With Strain Based Elastography Imaging C) Linear Array Transducer With Bandwidth Frequency Of (4.0 To 15.0 Mhz) For Vascular Access, Small Parts, Msk Imaging Application With Strain Based Elastography Imaging Or D)Linear Transducer With Bandwidth Frequency Of (3.0 To 11.0 Mhz)For Small Parts, Msk And Vascular Access Imaging Application Special Preference System Must Have Artificial Intelligence Based Tools That Includes As Below Or One Touch Calculation As Asked. Parameters To Be Demonstrated: - • Auto Detection Of Nerve At Femoral, Brachial & Sciatic With Video Assist. • Msk Video Assist Diagram • Efast Protocol With One Page Analysis Diagram Should Be There As Standard. • Needle Enhancement With Color & Power Doppler Should Be Enabled For Intervention. Panoramic Scan With 60 Cm Length Should Be There 1

BOQ

Name of Work:- Purchase of Portable Ultrasound Machine at Rajeev Gandhi Sports Medicine Center
Sl. No. Item Description
1Portable Ultrasound Machine
2Purchase of Portable Ultrasound Machine at Rajeev Gandhi Sports Medicine Center - 1 Purchase of Portable Ultrasound Machine at Rajeev Gandhi Sports Medicine Center • Should be a diagnostic Musculoskeletal Ultrasound Machine• Complete with preset & measurement for sports Medicine application, musculoskeletal imaging, general imaging, vascular small parts, thyroid, and CEUS with quantification tool fully integrated in main unit to measure wi/ wo curves and intensity against time packages.• System should be of latest technology with Windows 10 OS or better based platform• Rotatable keyboard with height adjustment, should include alphanumeric keyboard with min 10” colour LCD touch screen for accession functions• Tiltable 15 ” or higher medical grade display Monitor with articulating arm• Should have 3 active pin less probes connectors• Should have 2D frame rate of minimum 800 or higher frames per sec• Should have colourdoppler frame rate of 300 Hz or more• Should have minimum 256 or higher gray levels• Should have dynamic range of 350dB or higher• Archiving capabilities with sorting of clips and still images in SSD storage• Internal SSD storage with minimum of 128 GB or higher• B-Mode/ Dual –B Mode/ M-Mode• PW/ HPRF Doppler• Colour Doppler and power Doppler• Speckle reduction software• Should have post processing from stored data• Should have follow-up option for comparison of post and pre surgery with different modality like MRI/ CT or same modality• Speed of sound regulation- possibility to modify the speed of value in order to focalization on the lateral direction• Should have panoramic imaging of minimum 60 cm or higher with CFM• Ultra sensitivity colour Doppler to pick up small vessels and slow flow detections• Unlimited users preset for all applications• System imaging capable from 1 to min 22Mhz or higher frequency for superficial imaging applications• Should have radio frequency based intima media thickness measurement• Should have radio frequency based arterial stiffness measurements• Should have strain based Elastography in linear array & convex array probes• Should have quantification tools fully loaded in ultrasound for contrast study imaging with intensity curves• Should have option to upgrade to 2D shear-wave elastography in convex probes • Should supply a colour Ink – jet printer• Should have DICOM, USB, HDMi output in main unit• System should have CE and US-FDA certification• Standard transducer to be offered and the rate shall be quoted separately which will be considered for L1 evalution.a) Convex array transducer with bandwidth frequency of (1.0 to 8.0 MHz) with General imaging application with min 44cm Depth or higher with strain based elastography imagingb) L-shape linear array transducer with bandwidth frequency of (6.0 to 18.0 MHz) for vascular access, small parts, MSK & sports medicine imaging application with strain based elastography imagingc) Linear array transducer with bandwidth frequency of (4.0 to 15.0 MHz) for vascular access, small parts, MSK imaging application with strain based elastography imagingOR d)Linear transducer with bandwidth frequency of (3.0 to 11.0 MHz)for small parts, MSK and vascular access imaging applicationSPECIAL PREFERENCESystem must have Artificial Intelligence based Tools that includes as below or one touch calculation as asked. Parameters to be demonstrated: -• Auto detection of Nerve at Femoral, Brachial & Sciatic with video assist.• MSK Video assist diagram • eFAST protocol with one page analysis diagram should be there as standard.• Needle enhancement with color & power doppler should be enabled for intervention.Panoramic scan with 60 cm length should be there 1 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57951001
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 23-10-2026
Authority
Authority Name Directorate Of Sports And Youth Affairs
Work Description Tender for Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center , Portable Ultrasound Machine , Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center - 1 Purchase Of Portable Ultrasound Machine At Rajeev Gandhi Sports Medicine Center • Should Be A Diagnostic Musculoskeletal Ultrasound Machine • Complete With Preset & Measurement For Sports Medicine Application, Musculoskeletal Imaging, General Imaging, Vascular Small Parts, Thyroid, And Ceus With Quantification Tool Fully Integrated In Main Unit To Measure Wi/ Wo Curves And Intensity Against Time Packages. • System Should Be Of Latest Technology With Windows 10 Os Or Better Based Platform • Rotatable Keyboard With Height Adjustment, Should Include Alphanumeric Keyboard With Min 10 Colour Lcd Touch Screen For Accession Functions • Tiltable 15 Or Higher Medical Grade Display Monitor With Articulating Arm • Should Have 3 Active Pin Less Probes Connectors • Should Have 2D Frame Rate Of Minimum 800 Or Higher Frames Per Sec • Should Have Colourdoppler Frame Rate Of 300 Hz Or More • Should Have Minimum 256 Or Higher Gray Levels • Should Have Dynamic Range Of 350Db Or Higher • Archiving Capabilities With Sorting Of Clips And Still Images In Ssd Storage • Internal Ssd Storage With Minimum Of 128 Gb Or Higher • B-Mode/ Dual -B Mode/ M-Mode • Pw/ Hprf Doppler • Colour Doppler And Power Doppler • Speckle Reduction Software • Should Have Post Processing From Stored Data • Should Have Follow-Up Option For Comparison Of Post And Pre Surgery With Different Modality Like Mri/ Ct Or Same Modality • Speed Of Sound Regulation- Possibility To Modify The Speed Of Value In Order To Focalization On The Lateral Direction • Should Have Panoramic Imaging Of Minimum 60 Cm Or Higher With Cfm • Ultra Sensitivity Colour Doppler To Pick Up Small Vessels And Slow Flow Detections • Unlimited Users Preset For All Applications • System Imaging Capable From 1 To Min 22Mhz Or Higher Frequency For Superficial Imaging Applications • Should Have Radio Frequency Based Intima Media Thickness Measurement • Should Have Radio Frequency Based Arterial Stiffness Measurements • Should Have Strain Based Elastography In Linear Array & Convex Array Probes • Should Have Quantification Tools Fully Loaded In Ultrasound For Contrast Study Imaging With Intensity Curves • Should Have Option To Upgrade To 2D Shear-Wave Elastography In Convex Probes • Should Supply A Colour Ink - Jet Printer • Should Have Dicom, Usb, Hdmi Output In Main Unit • System Should Have Ce And Us-Fda Certification • Standard Transducer To Be Offered And The Rate Shall Be Quoted Separately Which Will Be Considered For L1 Evalution. A) Convex Array Transducer With Bandwidth Frequency Of (1.0 To 8.0 Mhz) With General Imaging Application With Min 44Cm Depth Or Higher With Strain Based Elastography Imaging B) L-Shape Linear Array Transducer With Bandwidth Frequency Of (6.0 To 18.0 Mhz) For Vascular Access, Small Parts, Msk & Sports Medicine Imaging Application With Strain Based Elastography Imaging C) Linear Array Transducer With Bandwidth Frequency Of (4.0 To 15.0 Mhz) For Vascular Access, Small Parts, Msk Imaging Application With Strain Based Elastography Imaging Or D)Linear Transducer With Bandwidth Frequency Of (3.0 To 11.0 Mhz)For Small Parts, Msk And Vascular Access Imaging Application Special Preference System Must Have Artificial Intelligence Based Tools That Includes As Below Or One Touch Calculation As Asked. Parameters To Be Demonstrated: - • Auto Detection Of Nerve At Femoral, Brachial & Sciatic With Video Assist. • Msk Video Assist Diagram • Efast Protocol With One Page Analysis Diagram Should Be There As Standard. • Needle Enhancement With Color & Power Doppler Should Be Enabled For Intervention. Panoramic Scan With 60 Cm Length Should Be There 1
Basic Detail
Tender No 18/DSYA/2026-27
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 09 Oct 2026
Submission Date 23 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 2500
EMD 50000
Exemption Available
Document List
BOQ_1491886.xls
eac4d549-3707-47f8-99b7-95db521792a8.html
Portableultrasound.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1491886.xls

html

eac4d549-3707-47f8-99b7-95db521792a8.html

pdf

Portableultrasound.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders