Tender For Maintenance And Repairs To Street Lights, Security Lights, Perimeter Lights, Search Lights, High Mast Lights, And Connected Works At Domestic And Tech Area Of Afs Yelahanka Under Ge (Af) Yelahanka.
Tender Value
47 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
1 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance And Repairs To Street Lights, Security Lights, Perimeter Lights, Search Lights, High Mast Lights, And Connected Works At Domestic And Tech Area Of Afs Yelahanka Under Ge (Af) Yelahanka.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and directed. |
| 2 | Returning filling in excavated soil up to a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and directed.v |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and directed. |
| 5 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation complete all as specified and directed. |
| 6 | M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all of specified and directed. |
| 7 | Supply and laying in trenches, LT underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional area 6 Sqmm, 2 core multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed. |
| 8 | All same as per item No 7 here-in-before but cross-sectional area 10Sqmm, 4 Core. |
| 9 | All same as per item No 7 here-in-before but cross-sectional area 16 Sqmm, 4 Core. |
| 10 | All same as per item No 7 here-in-before but cross-sectional area 25 Sqmm, 3.5 Core. |
| 11 | Note: For Sl No 7 to 10, necessary excavation shall be measured and paid under respective items of the same schedule separately. |
| 12 | M&L for preparing of old faded paint surface and painting with one coat of synthetic enamel paint to existing LT Steel tubular poles of size 9 m long up to the height of 1.2 m from the bottom with approved white and blue colour alternatively including pole number with paint same as existing earlier complete all as specified and directed. |
| 13 | M&L for preparing of old faded painted surface of 9 m long steel tubular pole complete including all accessories such as cross arms, bracings, brackets etc and painting with two coats of aluminium paint of approved make including writing pole number with paint same as existing earlier complete all directed. |
| 14 | Supply and fix in repair LED street light fitting 45-Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed. |
| 15 | All same as per item No 14 here-in-before but capacity 60 Watt. |
| 16 | All same as per item No 14 here-in-before but capacity 72 Watt. |
| 17 | All same as per item No 14 here-in-before but capacity 90 Watt. |
| 18 | Supply and fix in repair energy saving rectangular LED flood light fitting 150 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed. |
| 19 | All same as per item No 18 here-in-before but capacity 200 Watts. |
| 20 | All same as per item No 18 here-in-before but capacity 250 Watts. |
| 21 | All same as per item No 18 here-in-before but capacity 100 Watts. |
| 22 | All same as per item No 18 here-in-before but capacity 70 Watts. |
| 23 | Supply and fix in repair energy saving rectangular LED flood light fitting 50Watts, 240 volts AC, Colour changing light (RGB) controlled by smart application facility of OEM , CCT 5700°K, CRI>70, THD<10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing by means of clamps, nuts, bolts and any other accessories complete all as specified and directed. |
| 24 | Repair and maintenance of all type Street/Security light fittings 45/60/70/90-watt capacity and flood light fittings 150/170/200/250-watt, solar street light fittings 10/12-watt capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the same pole/place complete all as specified and directed. |
| 25 | Supply and fix in repair of terminal box made out of made up of FRP/ Polycarbonate and locking arrangements of size 240x140x95mm Including, Backlite 4-way connector S Clamps suitable for pole, PCC/MS/GI/rail etc. with bolt, nut and washer, electrical connections incl MCB SP 6-32 Amps complete all as specified and directed |
| 26 | Supply and fix in repair three single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size and one single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing u/s one complete all as directed. |
| 27 | Supply and in repair three core PVC cable, FRLS with copper conductor round cable 1.5 Sqmm for connection from junction box to street light fittings complete all as directed. |
| 28 | Supply and fix in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB complete with connection testing and commissioning all as specified and directed. |
| 29 | Supply and fixing in repair 230V 10KA 'C' curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the Junction box/DB complete with connection testing and commissioning all as specified and directed. |
| 30 | M & L for boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure complete all as specified and directed. |
| 31 | Supply & lay GI tubing light grade 50 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed. |
| 32 | Supply & lay GI tubing light grade 40 mm bore intrenches/fixing on pole/wall/crossing in drain etc. for protection of UG cable complete all as specified and directed. |
| 33 | Supply and fix in repair driver suitable for 45-Watt LED light fittings and testing complete all as specified and directed. |
| 34 | Supply and fix in repair driver suitable for 60-Watt LED light fittings and testing complete all as specified and directed. |
| 35 | Supply and fix in repair driver suitable for 70/72-Watt LED light fittings and testing complete all as specified and directed. |
| 36 | Supply and fix in repair driver suitable for 90-Watt LED light fittings and testing complete all as specified and directed. |
| 37 | Supply and fix in repair driver suitable for 150-Watt LED flood light fittings and testing complete all as specified and directed. |
| 38 | Supply and fix in repair driver suitable for 200/250-Watt LED flood light fittings and testing complete all as specified and directed. |
| 39 | Supply and fix in repair LED Aviation light luminaries Integral LED aviation light 12 W comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed |
| 40 | Supply and fix LED Decorative multicolour light DIY Spike light of capacity 5 Watt , IP66 , 240 V , suitable for mounting on the ground as well as wall , offering enhanced aesthetic design possibilities and with momentary switch can be set at multiple colours as per requirement, The heat sink is made up of high pressure die cast aluminum suitable to mount on ground (with spike ) and on wall (without spike ) , a momentary switch made up of SS 304 havingIP67 is provided offered with system lumen efficacy of 300 lm/ watt at correlated cloud temperature (CCT) of colour white / warm white , ANSI Tolerance , colour temp rendering index (CRI) > 70 and L70 rated lifetime of 35000 hours , electrical class I. AC power factor > 0.95, offered with BIS certified potted driver having internal surge protection of 4KV the luminaire shall emit colour in cyclic rotation (red, blue, orange , yellow , pink, cool white and then warm white) dimensions of fixture shall be minimum 310x88.6x70mm . Make Orient / Havells/ Halonix/ Crompton Please Enable Macros to View BoQ information |
| 41 | Supply and fix LED Decorative multicolour light DIY Spike light of capacity 5 Watt , IP66 , 240 V , suitable for mounting on the ground as well as wall , offering enhanced aesthetic design possibilities and with momentary switch can be set at multiple colours as per requirement, The heat sink is made up of high pressure die cast aluminum suitable to mount on ground (with spike ) and on wall (without spike ) , a momentary switch made up of SS 304 havingIP67 is provided offered with system lumen efficacy of 300 lm/ watt at correlated cloud temperature (CCT) of colour white / warm white , ANSI Tolerance , colour temp rendering index (CRI) > 70 and L70 rated lifetime of 35000 hours , electrical class I. AC power factor > 0.95, offered with BIS certified potted driver having internal surge protection of 4KV the luminaire shall emit colour in cyclic rotation (red, blue, orange , yellow , pink, cool white and then warm white) dimensions of fixture shall be minimum 310x88.6x70mm . Make Orient / Havells/ Halonix/ Crompton Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayNov 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer