Tender For Repair And Maintenance Of External Electric Supply Incl Cables, Panels And Earthing Under Age E/M At Ge Nrc
Tender Value
30 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
18 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of External Electric Supply Incl Cables, Panels And Earthing Under Age E/M At Ge Nrc
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 3 | Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 4 | Disconnecting & taking out cable LT 1100V grade any size complete all as specified. |
| 5 | S&F and lay in trenches or fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 3.5 core 500 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, armoured with galvanised steel strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed. |
| 6 | All as per Ser item No 5.00 here in before but 3.5 Core 50 Sqmm |
| 7 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 110 mm and inner dia 95mm including 90 degree bends with coupler and rubber ring laid in trenches for cable protection of size 500 sqmm cable complete all as specified and directed. |
| 8 | M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50 mm and inner dia 38 mm including 90 degree bends with coupler and rubber ring laid in trenches for cable protection of size 50 sqmm cable complete all as specified and directed. |
| 9 | Supply, fix, test and commissioning in repair of cable jointing kit of size from 16 sqmm to 50 sqmm 3.5 or 4 core, heat shrinkable 1100 Volts, XLPE straight through joints complete all as specified and directed. |
| 10 | Supply, install, test and commissioning in repair outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- Outer shell: The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. |
| 11 | Inner shell: Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys, to accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 630 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 kA, with Microprocessor release between 70-100% - 01 No.(b) Outgoing : (i) MCCB 250 Amps, 3 pole, 415 Volts, 50 Hz ICU 36 kA Microprocessor release between 70-100% - 02 Nos. (ii) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 03 Nos. (c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ratio should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.Location : Sub Stn No 32 |
| 12 | M&L for pole Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion including taking down old earthing complete all as directed.Note: These earthings shall be provided for poles, without provision of concrete earth pits. |
| 13 | M&L for Earthing complete with galvanized steel earth plate electrode 600x 600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI strip 32x6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. |
| 14 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for LT under ground cables suitable for 0.4 mPa working pressure complete all as specified and directed. |
| 15 | Supply, install, test and commissioning in repair outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- Outer shell: The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. |
| 16 | Inner shell: Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 kA with Microprocessor release between 70-100% - 01 No.(b) Outgoing : (i) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 01 Nos. (ii) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 04 Nos. (c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.(iv) Digital time switch with contactor 63 Amp.Location : Near Sainik Circle and P-8 AOP. |
| 17 | Taking down after disconnecting of cable connections from old burnt/ unserviceable MCCB and S&F MCCB 160 Amps FP, 415 V with microprocessor release and breaking capacity 36 kA capacity, retrofit complete with fixing arrangement in the existing LT panel board complete all as specifiedand directed. |
| 18 | All as per Ser Item No 15.00 above, but 250 Amps, 4 pole, 36 kA. |
| 19 | All as per Ser Item No 15.00 above, but 400 Amps, 4 pole, 36 kA. |
| 20 | All as per Ser Item No 15.00 above, but 630 Amps, 4 pole, 50 kA. |
| 21 | M&L for locating fault in U/G HT cable by using fault detector machine including transportation and by carring out high pressure test all as directed. |
| 22 | Supply, install, test commissioning in repair of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- Outer shell : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. |
| 23 | Inner shell : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 kA with Microprocessor release between 70-100% - 01 No.(b) Outgoing : (i) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 02 Nos. (ii) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 03 Nos. (c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.(iv) Digital time switch with contactor 63 Amp.Location : In front of AOP Mandir and GE Office |
| 24 | Supply, fix, test and commissioning in repair of cable jointing kit of size from 70 sqmm to 150 sqmm 3.5 or 4 core, heat shrinkable 1100 Volts, XLPE straight through joints complete all as specified and directed. |
| 25 | NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 42,595.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender