Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57947148

Tender For Special Repair Of Harshvardhan Auditorium In Police Complex, Hpa Madhuban.

Issued by Government Departments · Karnal, Haryana
Tender Value
4.18 Crore
Estimated cost
Bid Submission
19 Oct 2026
6 days left
EMD
8.36 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Karnal → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Harshvardhan Auditorium In Police Complex, Hpa Madhuban.

BOQ

Name of Work:- Special Repair of Harshvardhan Auditorium in Police Complex, HPA Madhuban.
Sl. No. Item Description
1HSR PART[10.50.1]Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 1. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. [Through Rate]
2[10.51]Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc. [Through Rate]
3[10.61]Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. [Through Rate]
4[10.62]Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. [Through Rate]
5[10.63.4]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 4. Size of Tile 1000x1000 mm [Through Rate]
6[10.7]Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4 [Through Rate]
7[10.76]Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design and shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. [Through Rate]
8[11.4.2]10 mm thick cement plaster 2. 1:3 (1 cement: 3 fine sand) [Through Rate]
9[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
10[11.6.2]15 mm cement plaster on the rough side of single or half brick wall of mix : 2. 1:6 (1 cement: 6 fine sand) [Through Rate]
11[11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate]
12[11.67.1]Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 1. Water thinnable cement primer [Through Rate]
13[11.76]Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. [Through Rate]
14[11.77]Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. [Through Rate]
15[11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate]
16[12.102.1]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm [Through Rate]
17[12.102.2]Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 2. 100 mm [Through Rate]
18[12.103.2]Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper [Through Rate]
19[12.157.1.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate]
20[12.157.2.2]Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) [Through Rate]
21[12.159.2]Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 2. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) [Through Rate]
22[12.19.1.1.2]Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1.1.2. 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Kiln seasoned and chemically treated Hollock wood [Through Rate]
23[12.37.1]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws [Through Rate]
24[12.37.3]Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 3. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws [Through Rate]
25[12.56.1]Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : 1. 125x90x4.00 mm [Through Rate]
26[12.98.1]Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1. 300x16 mm [Through Rate]
27[12.99.3]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm [Through Rate]
28[12.99.5]Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5. 100x10 mm [Through Rate]
29[13.10.2]Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 2. 5.5 mm thick glass panes [Through Rate]
30[13.24.1]Providing and fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of Gasket / beading shall be paid as per respective item) 1. Float glass panes of 5.5mm thickness [Through Rate]
31[13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate]
32[13.3.2.2]Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 2.2. Profile C Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) [Through Rate]
33[13.4.1]Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) [Through Rate]
34[13.9.2]Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S. Flat 15x3 mm and nuts and bolts complete. 2. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides [Through Rate]
35[14.1]Dressing bed and preparation of sub grade for lining by mechanical/ mannual means [Through Rate]
36[20.72]Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. [Through Rate]
37[20.86]Supply, erection, testing and commissioning of G.O. Switch two poles, with blade, pin 6 insulators operating handle with GI pipe 25 mm class B complete in all respects. [Through Rate]
38[21.91.1]Construction of circular standard brick-masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular sewers up to the required depth in 1:5 cement sand mortar lime concrete in bed and sides of pipe-sewer and cement concrete 1:2:4 in benching 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with two coats of sodium silicate of interior surface where required fixing cover and frame weight not less than 2:5 quintal painted with 3 coats of black bitumen paint fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. The rate covers the cost of carriage of C.I. manhole, frame and cover and malleable iron steps from the stores of the engineer-in-charge of the works to site of works. the rate also includes the cost of accurately planed and fitted centring supports for all works as well as for all curves and special works cleaning out their beds etc. Sodium silicate will be supplied free of cost at the stores of the Engineer-in-charge. 1. For 1.80 metres depth below ground level - on 175 mm internal diameter pipe sewer [Through Rate]
39[22.1.3]Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 3. White vitreous chinaware Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps [Through Rate]
40[22.101.1.2]Providing and fixing Unplasticised PVC connection pipe with brass unions : 1.2. 30 cm length 20 mm nominal bore [Through Rate]
41[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
42[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
43[22.108.1]Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 1. 15mm nominal bore [Through Rate]
44[22.14.1.1]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 1.1. Semi rigid pipe 32 mm dia [Through Rate]
45[22.181]Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. [Through Rate]
46[22.210.2]Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 2. Rectangular shape 453x357 mm [Through Rate]
47[22.210.4]Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 4. Rectangular shape 1500x450 mm [Through Rate]
48[22.216.1]Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 1. 25 Litres capacity [Through Rate]
49[22.22.1]Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [Through Rate]
50[22.222.2.2]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete [Through Rate]
51[22.222.2.3]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.3. Single Socket Type B 90mm o/d SWR UPVC pipe lines laid complete [Through Rate]
52[22.25.2]Providing and fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 2. One urinal basin with manually operated 5 litres PVC cistern and manually operated stop cock/ angle valve [Through Rate]
53[22.25.3]Providing and fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 3. Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern [Through Rate]
54[22.33]Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. [Through Rate]
55[22.38]Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. [Through Rate]
56[22.50.1.1.1]Providing and fixing partitions for different type of urinals. 1.1.1. Vitreous Chinaware Partition plate. Small size 680mm x 330 mm White [Through Rate]
57[22.87.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 2. 20 mm nominal outer dia Pipes [Through Rate]
58[22.87.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 3. 25 mm nominal outer dia Pipes [Through Rate]
59[22.87.4]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 4. 32 mm nominal outer dia Pipes [Through Rate]
60[22.87.5]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External work 5. 40 mm nominal outer dia Pipes [Through Rate]
61[23.22.4.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.12. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 12 way ( 8 incoming 3phase*12 outgoing) [Through Rate]
62[23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) [Through Rate]
63[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
64[23.23.5.4]MISCELLANEOUS 5.4. Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 50x50 mm [Through Rate]
65[23.23.7.2]MISCELLANEOUS 7.2. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 200 X 50 X 2 mm [Through Rate]
66[23.23.7.3]MISCELLANEOUS 7.3. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 375 X 50 X 2 mm metre [Through Rate]
67[23.23.7.4]MISCELLANEOUS 7.4. Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover , suitable for cable tray of 600 X 50 X 2 mm [Through Rate]
68[23.23.8.1]MISCELLANEOUS 8.1. Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire [Through Rate]
69[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
70[23.24.1]MS STAND, BUS BAR CHAMBER AND PANELS 1. Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. [Through Rate]
71[23.24.4.4]MS STAND, BUS BAR CHAMBER AND PANELS 4.4. Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. / volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCBs ) etc.suitable for operation of 240/415 volts A.C. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. Load Bank 8 way 400 amp. [Through Rate]
72[23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate]
73[23.28.1.3]Supplying, installation, Testing and Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , UGR (Unified Glare Rating) ( 19, Flicker free (flicker should be below 5%), life time (LED,Driver and electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and (120 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) 3. Powder coated die cast /Extruded aluminum Body including trim 12-15 watt [Rate]
74[23.28.11.4]Supplying, installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency )85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80 , Flicker free (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer- in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast /Extruded aluminum Body (Thickness >= 1.20 mm) 40 Watt [Rate]
75[23.28.17.5]Supplying, installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 5. 200 watt [Rate]
76[23.28.20.2]Supplying, installation, Testing and Commissioning of Smart Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement ( ( 700ma), Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-08, CRI )80 , under voltage and over voltage protection, EMI- EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K(As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 1. Control and monitor LED luminaries with bi directional control ( Status, Fault, Alarm, dimming level, wattage, energy)2. to measure voltage, current, power, power factor, apparent energy, active energy, operating hours.3. Inbuilt ambient light sensor, motion sensor based on Passive Infra Red (PIR).4. Wi-Fi LoRA/Zigbee/Power line with Ethernet network based IOT feature as per site requirement or engineer in charge.5. should be controlled through auto/ manual6. Programmable level of not less than 48 different light intensity settings,7. Inbuilt repeater and relay signals function to other controllers 2. 50 Watt [Rate]
77[23.28.3.4]Supplying, installation, Testing and Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection ,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 4. Powder coated die cast / Extruded aluminum Body including trim 18 watt [Rate]
78[23.29.2.3]Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 3. 1200mm, service value >= 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) [Rate]
79[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
80[23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
81[23.3.6.4]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
82[23.33.1 (a).2]Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be ( 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 and 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 2. 3KVA [Rate]
83[23.35.14.11]COPPER REFRIGERANT PIPINGSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 11. 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm [Rate]
84[23.5.1.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 1.1. Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group A [Through Rate]
85[23.5.2.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 2.1. Wiring only in existing conduit and MS box for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable. Group A [Through Rate]
86[23.5.4.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 4.1. Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group A [Through Rate]
87[23.5.5.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 5.1. Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group A [Through Rate]
88[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
89[23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate]
90[23.5.6.4]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.4. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 6 Sqmm(1/2.80mm) [Through Rate]
91[23.5.6.5]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.5. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm) [Through Rate]
92[23.7.6.1]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.1. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia. [Through Rate]
93[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
94[23.7.6.3]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.3. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 32 mm dia. [Through Rate]
95[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate]
96[23.8.10.1]FITTING AND ACCESSORIES 10.1. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data [Through Rate]
97[23.8.10.2]FITTING AND ACCESSORIES 10.2. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 3 Modules [Through Rate]
98[23.8.10.4]FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules [Through Rate]
99[23.8.10.6]FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules [Through Rate]
100[23.8.11.1]FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch [Through Rate]
101[23.8.11.3]FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch [Through Rate]
102[23.8.11.4]FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket [Through Rate]
103[23.8.11.5]FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket [Through Rate]
104[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
105[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
106[24.1.16]EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. [Through Rate]
107[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
108[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
109[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
110[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
111[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
112[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
113[24.10.1]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 1. Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Metre. underground cable excluding the cost of cable/pipe complete in all respect. [Through Rate]
114[24.10.4]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 4. cement concrete 1:2:4 with stone aggregate 20 mm nominal size in Kerbs and the like items, finished smooth with 6 mm thick cement plaster 1:3 on exposed surface including from work, placing and fixing in position, complete at the ground level or in first storey [Through Rate]
115[24.10.6]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 6. Digging of pucca road in required width for laying of cable / pipe complete in all respect up to the entire satisfaction of Engineer-in charge [Through Rate]
116[24.12.48]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 48. 50 Sq mm 4 core (Arm.) [Through Rate]
117[24.13.56]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 56. 70 Sq mm 4 core (Arm.) [Through Rate]
118[24.13.62]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 62. 95 Sq mm 3.5 core (Arm.) [Through Rate]
119[24.13.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate]
120[24.14.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
121[24.16.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core [Through Rate]
122[24.4.2.4]STREET LIGHT 2.4. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 150 cm long, with 30 cm high suitable size pole cap. [Through Rate]
123[24.4.6]STREET LIGHT 6. Supply and erection of Three Phase weather proof M.S. box of size 30 cm x 20 cm x 15 cm with hinged cover made of 2 mm thick MS sheet, locking arrangements, housed in wall/fixed on pole , including the cost of 1 no 4 way 16 A Bakelite connector, 1 no. 16 amp TP MCB and 4 Nos. 16 amp. neutral links fixed on Bakelite sheet in the M.S. box and necessary connections. [Through Rate]
124[24.5.2.1]MISCELLANEOUS ITEMS 2.1. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 40/32 mm outer dia/ inner dia [Through Rate]
125[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
126[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]
127[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia [Through Rate]
128[25.10.13.1]Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 1. Indoor units [Rate]
129[25.10.13.2]Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 2. Outdoor Multi Join [Rate]
130[25.10.14.1]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 1. 6.4 mm dia (OD)(SOFT) with tube thickness 1.2 mm [Rate]
131[25.10.14.12]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 12. 41.25 mm dia (OD)(HARD DRAWN) with tube thickness 1.2 mm [Rate]
132[25.10.14.2]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 2. 9.5 mm dia (OD)(SOFT) with tube thickness 1.2 mm [Rate]
133[25.10.14.3]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 3. 12.7mm dia (OD)(SOFT) with tube thickness 1.2 mm [Rate]
134[25.10.14.4]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 4. 15.86 mm dia (OD)(SOFT) with tube thickness 1.2 mm [Rate]
135[25.10.14.5]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 5. 19 mm dia (OD)(HARD DRAWN) with tube thickness 1.2 mm [Rate]
136[25.10.14.6]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 6. 22.2 mm dia (OD)(HARD DRAWN) with tube thickness 1.2 mm [Rate]
137[25.10.14.8]COPPER REFRIGERANT PIPING Supplying, Installation, testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 8. 28.58 mm dia (OD)(HARD DRAWN) with tube thickness 1.2 mm [Rate]
138[25.10.3.3]OUTDOOR UNIT Supplying, Installation, Testing and Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V plus /- 10%, 3 Phase, 50Hz AC power supply and BMS compatible The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity (40 kWr ISEER 7.4, Capacity ) 40 and (70 ISEER 7.5, Capacity ) 70 ISEER 7.6 for Super ECSBC Building) 3. For Cooling or Heating or Both 14 HP to 22 HP [Rate]
139[25.10.4.7]INDOOR UNIT Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor) 7. 2.6 TR [Rate]
140[25.11.2.6]HI - WALL SPLIT SYSTEMS Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low and high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 6. Inverter Type- Hot & Cold 1.5 TR with 3 Star BEE Rating [Rate]
141[25.14.1.9]CEILING SUSPENDED AHU Supplying, Installation, testing and commissioning of Factory built ceiling suspended chilled water double skin type horizontal/vertical air handling units of following capacity, made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with Polyurethane Foam (PUF) insulation factory injected betweenthem by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 4 rowdeep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with Totally Enclosed Fan Cooled (TEFC) drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for Variable Frequency Drive (VFD) applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial typepressure gauges (2 nos.)and industrial type thermometres (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration Isolation arrangement, noise level shall not exceed 70 dB. AHU shall be AHRI/Eurovent certified, fan shall be AMCA certified etc.Complete as per CPWD specification/drawingsand as directed by Engineer-in-Charge (Total static pressure considered is 50 mm WG). 9. 8000 CFM [Rate]
142[25.7.1]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 1. Thickness 0.63 mm sheet [Through Rate]
143[25.7.3]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 3. Thickness 1.00 mm sheet [Through Rate]
144[25.7.4]Supply, installation, and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 4. Thickness 1.25 mm sheet [Through Rate]
145[25.9.13]Supplying, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate]
146[25.9.15]Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate]
147[25.9.16]Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate]
148[25.9.17]Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. [Rate]
149[25.9.20.1]Supplying, Fixing, installation, testing and commissioning of fire dampers of minimum 9 minutes fire rated in supply air/duct branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required. 1. Fire damper [Rate]
150[25.9.21]Supplying and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, [Rate]
151[29.5]Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevant Item).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. [Through Rate]
152[30.16.1]Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 1. With cement mortar 1:4 (1 cement : 4 fine sand) [Through Rate]
153[30.17]Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. [Through Rate]
154[30.21]Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete [Through Rate]
155[30.22]Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. [Through Rate]
156[30.25.1]Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : 1. Old work (one or more coats) [Through Rate]
157[30.37.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. Old work (Two or more coat applied @ 1.67 litre/ 10 sqm) on existing cement paint surface [Through Rate]
158[30.58]Renewal of old putty of glass panes (length) [Through Rate]
159[30.9]Regarding terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in-Charge. [Through Rate]
160[32.47.1]Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance = 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 and7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre and 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 1. With 16 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 [Through Rate]
161[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate]
162[36.1.7]Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required:(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-`F` insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation duly plastered with anti vibration pads. 7. 2280 lpm at 88 M Head [THROUGH RATE]
163[36.12.1]Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 offollowing sizes as required: 1. 50 mm dia [THROUGH RATE]
164[36.12.5]Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 offollowing sizes as required: 5. 150 mm dia [THROUGH RATE]
165[36.12.7]Supplying, fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 offollowing sizes as required: 7. 250 mm dia [THROUGH RATE]
166[36.17.1]Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type 2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve and nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve and M.S. Pipe and socket. 1. 30m [THROUGH RATE]
167[36.19.1]Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 1. 2 way-100 mm dia M.S. Pipe [THROUGH RATE]
168[36.20]Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve withrequired accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. [THROUGH RATE]
169[36.21.1]Providing, fixing, testing and commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 °C with required accessories: 1. Pendent Sprinkler [THROUGH RATE]
170[36.4.2](a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-`F` insulation,conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 2. 450 lpm at 35 M Head [THROUGH RATE]
171[36.48]Supply, Insallation, testing and commissioning of Electrical fire pump panel for terrace fabricated with 2mm thick Ms sheet with hinged lockable doors, powder coated of approved shade including all accessories complete in all respect. 450 LPM. [THROUGH RATE]
172[36.5.3]Fabrication, supplying, Installation testing and commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cablealley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earthterminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3phase, 50Hz Ac Supply with enclosure protection class IP 42 as required: 3. INCOMING630A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800AmpsOUTGOINGMain Fire Pump 250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Diesel Engine Control Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automaticoperation of diesel engineSystem ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. [THROUGH RATE]
173[36.51]Providing, fixing, testing and commissioning of AUTO GLOW EXITSIGNS with acrylic and another suitable sheet size 100MMX400MMwith complete all respect. [THROUGH RATE]
174[36.52]Providing, fixing, testing and commissioning of Wall Mounted or Free Standing Type , Weather proof hose cabinet of size 750 x 600 x 250mm with glazed double door fabricated with MS sheet of 16 gauge to accumulate 2 nos. Delivery Hoses of 15m lenght and Branch Pipe complete in all respect. [THROUGH RATE]
175[36.7.1]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 1. 25 mm dia [THROUGH RATE]
176[36.7.10]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 10. 250 mm dia [THROUGH RATE]
177[36.7.2]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 2. 32 mm dia [THROUGH RATE]
178[36.7.3]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 3. 40 mm dia [THROUGH RATE]
179[36.7.7]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 7. 100 mm dia [THROUGH RATE]
180[36.7.8]Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required. shade complete as required: 8. 150 mm dia [THROUGH RATE]
181[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
182[4.39]Providing and injection chemical emulsion for PRE-CONSTRUCTIONAL ant termite treatment (excluding the cost of chemical emulsion) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20% [Through Rate]
183[5.23.1]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 1. Nominal concrete 1:1.5:3 or richer mix (i/c equivalent design mix) [Through Rate]
184[5.43.1]Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1. For thickness of tiles 10 mm to 25 mm [Through Rate]
185[5.44]Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. [Through Rate]
186[5.46.3]Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : 3. Thickness above 25 mm up to 40 mm [Through Rate]
187[5.49]Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. [Through Rate]
188[6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate]
189[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate]
190[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
191[6.9.1]Providing and laying damp-proof course with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20mm nominal size) 1. 50 mm thick [Through Rate]
192[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
193[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
194[9.17.1]Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 1. In 75x75 mm deep chase [Through Rate]
195[9.32.2]Providing and fixing UV stabilised fibreglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated `J` or `L` hooks, bolts and nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2. 2 mm thick flat [Through Rate]
196[9.35]Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. [Through Rate]
197[9.47.5]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 5. 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I [Through Rate]
198[9.49.2]Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing `C` wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm centre to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centres with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : 2. GI Metal Ceiling Clip in plain Bevelled edge global white colour tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. [Through Rate]
199[9.50.1]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rock wool of 48 kg /cum backing. [Through Rate]
200NS PARTEarth filling with earth brought from outside the campus, irrespective of any lead, including laying in 15cm in layers, watering and consolidating complete in all respect and fully satisfaction of Engineer-in-charge (Based on HSR 2021).
201Providing and Fixing of Spandex System on G.I studs 2400mm X 50mm web flanges 15 and 50mm fully knurled giving it high strength, hot dipped galvanized steel With 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick Rock wool @48kg density insulation intact with chicken mess wires. 600x1200x15mm Magnesite pine wool tile with NRC 0.9-1 to be mechanically fastened on the G.I Studs. Then 12mm clip rail system are screw fixed on to the 12 mm MDF waterproof and Acoustics panel’s .Then the Spandex is stretched over the clip rail system. The installed system should provide NRC OF 1.00. Spandex colour as per Architect choice-Ref attached specifications for more details. The system to be installed on G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 and 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration. MAKE: ANAKON/ECOPHON/HUNTER DOUGLAS (Upto any height).
202Providing and fixing 15mm thick coloured Acoustic Panels in size 1220 x 610mm of Natural panel having Premium Square Edge. Panels are made of Pine Wood fibers containing cellulose binded with Magnesite. The panels will be screw fixed @ 200mm on GI metal frame of 50 x 50mm making a grid of 610 x 610mm c/c. The frame is to be made in proper line after leveling. The panels will be backed with 50mm Rockwool of 24 kg/cum inserted inside the grid of 610 x 610mm which will comprise of minimum NRC 0.90 as per IS: 8225/ ISO: 354/ ASTM: 423 – 90 a. The panel meets the stringent fire test required having Class ‘P’ rating for Ignitability test as per BS 476 part 5 and Class ‘1’ rating as per BS 476 part 7 for Surface Spread of Flame test. Class ‘P’ and Class ‘1’ are the highest rating. BS 476 part 6 Fire Propagation index, I = not greater than 4.11. It should meet all technical parameter. MAKE: ANAKON/BAUX/ECOPHON (Upto any height).
203Providing and Fixing Acoustical Wooden Stage Flooring Compatible with Underground signal cabling and Pop-Up Boxes: Providing and fixing 65/75 X 18 thick in random length, 2nd class teak wood planks flooring with tongue and groove joints on a layer of 15 mm thick Engineering wood of approved make and manufacture, fixed to hardwood joint 50 X 50 mm at 600 mm c/c in one direction and 60 X 50 mm Sal battens 600mm c/c on other direction, Hardwood joint resiliently supported on 100 X 100 mm Rubber Pads, the framework to be filled with 50mm thick Insulation Wool resin bonded insulation of density 24kg/cum. PU polishing of teakwood on the exposed surface: In horizontal/vertical plane (rate for flooring shall include providing additional framework required for housing microphone and power outlet junction - signal and Popup Stage boxes, If required providing and fixing hinged 18mm thick Engineering wood cover for the junction boxes. Work complete in all Respect. The Work shall be executed as per drawings, Specifications and Instruction of engineer in charge.MAKE:Greenlam, ACTION TEASA, Lemiwood.
204Providing and fixing of Woven vinyl carpet floorings series with roll dimensions of 1.8/2mtr meters width and length of 20 meters or Tiles size as per company standard should be approved by architech. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding.As per approved shade and colour as per the satisfaction of the Architect.MAKE: LG/ Woderfloor.
205Supplying and Fixing of Radium glow Stair case Nose made out of anodized aluminium profile having UV exposure shrinkage, anti slip resistance comes in different colour and sizes with the length of 2.5mtrs (Make ANAKON/DURAL/MEISER.
206Supply, installation, testing and fixing of MAIN FRONT VERTICAL CURTAIN made out of glazed cotton cloth with verticaly upward and Downward arrangement complete with fixing rails, brackets, moterised opration complete with required gear box, mini drums, weights, limit swithes, cuplink, runners, master runners,pullies, 3mm steel rope wire, 2HP motor (Crompton). 2 nos air breaker contactors (Landt/Siemens). Push buttton for stop, upward and downward positions.Motor mounting with C channel platform on side wall. Curtain cloth should be fire retarhdant Make D.Decore(Home India)/ ASIAN/ GM.
207Supply, installation, testing and fixing of Stage frills having size as required at stage as per site to be installed above the stage on 28mm dia GI pipe adjustable at position according to stage positioning plan. Cloth material of desired shade with Stitching and fire retardant
208Supply, Installation, Testing and commissioning of Rotatable Side wings made with 50 x 25 mm square pipe with rockwool insulation inside and covered with 6mm ply both side over which stretch fabric of approved colour to be applied
209Provided and fixing stage Proscenium to be fabricated on site made top side with 50x50mm MS square pipe. left and right proscenium wall fixed by using GI Framework spaced at 600mm c/c aluminum framework system is backline with 50 mm Roxul Rockwool and along with all accessories Infill in rockwool insulation padding. Fixing on 12 mm waterfroof ply.finishing with 1mm sun mica approved.
210Supply, installation, testing and fixing of REAR CURTAIN made out of glazed cotton cloth with horizontal sliding arrangement complete with fixing rails, brackets, moterised opration complete with gear box, runners, master runners,pullies, 3mm steel rope wire, 1HP motor (Crompton). 2 nos air breaker contactors (Landt/Siemens). Push buttton for stop, forward and reverse and close positions. minimum overlap at centre 900mm. The curtain stitched in double gathering.Curtain cloth should be fire retarhdant.
211Repairing of exisiting chairs with plywood institute moulded with polyurethane foam and upholstered fabric with requiste bolts/ dash fasteners etc fetaures.The polyutherene foam has Density =45 plus /-2 kgs/cu.m and hardness = 20 plus /-2 kgs on Hampden m/c at 25% compression Powder coating.
212Dismantling of existing Auditorium ceiling
213Dismantling of existing auditorium wall panelling
214Dismantling of existing auditorium stage ceiling
215Dismantling of existing auditorium stage wall panelling
216Dismantling of existing auditorium stage flooring
217Dismantling of existing auditorium flooring (Vinyl)
218Dismantling of existing auditorium stage curtains
219Dismantling of existing auditorium stage procenium
220Dismantling of existing auditorium stage wings
221Dismantling of existing auditorium stage frills
222Dismantling of existing auditorium stage chairs
223Providing and fixing in position CP Jali 110mm dia complete in all respect (Make JAYNA, YKING or as approved in brand list of HPHC)
224Repairing of LT Panel CRCA Panel Sheet 2.0mm with removing the rusting and welding, hinges, Nuts, Bolts, Washers, Ferule Numbers, Cable Ties, Tie Base, Copper Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors etc. and complete the work with proper finishing with Epoxy grey color paint complete in all respect as entire satisfaction of engineer in charge.
225Supply, carriage and laying of PVC unarm screened copper cable on surface / cable tray / in pipe with S/E of required thimbles, cable tie etc. required to complete the job. The Cable should be of either (i) 1sqmm x 4C unarm cable (for Auto operations of DG sets)
226Supply, Installation, Testing and Commissioning of 200W LED FRESNEL : Power Supply: AC 100V - 240V, 50-60HZ ,Light Source- COB LED, Wattage - 200W, CCT – 3200K / 5600K , CRI - =90, Beam angle - Manual 19°-50° gives a very soft edged beam as well as spreading a great deal of light outside the beam, Pan/ tilt - Manual Controls - DMX512,mater and slave, auto running, sound mode, DMX channels - 1/2CH (Single color), 2/5CH (2 in 1), 3/7CH (3 in 1, 4/8 CH (4 in 1),Color system - Single WW or CW (150W/ 200W/ 300W (2in1/4in1)180W( 3IN1), Optional, Dimmer/ strobe - 0~100% linearly adjustable Operating Voltage - 90-260V AC,IP Rating - IP20 Operating temperature - 30°C~50°C ,Finish - Black Weight - 8.5 Kg, Certification: CE.
227Supply, Installation, Testing and Commissioning of 200W LED PC: Power Supply: AC 100V - 240V, 50-60HZ, Light Source- COB LED , Wattage - 200W, CCT – 3200K/ 5600K , CRI - =90 , Beam angle - Manual 15°-35°,Pan/ tilt - Manual, Controls - DMX512,mater and slave, auto running, sound mode, DMX channels - 1/2CH(Single color),2/5CH (2in1), 3/7CH (3in1,4/8 CH(4in1) Color system - Single WW or CW (150W/ 200W/300W) 200W/300W(2in1/4in1)180W(3IN1), Optional Dimmer/strobe - 0~100% linearly adjustable Operating Voltage - 90-260V AC,IP Rating - IP20 Operating temperature - 30°C~50°C,Finish - Black Weight - 8.5 Kg, Certification: CE.
228Supply, Installation, Testing and Commissioning of RGBW LED PAR: Light Source: 54x3W RGBW LEDs Lamp life : 50,000 hrs, Input Voltages: AC90-260V 50/60Hz, ,Power Consumption: 170W, Strobe: high speed white color or color changing strobe with 1-13Hz frequency range, Dimmer: 0-100% electronic dimming Light Angle: 25°, Control: DMX512, master- slave and sound activated or auto operation, Channels: 7 DMX channels USITT DMX-512, Other Functions: LED display, IR Remote control (optional), automatic operation with built-in programs, efficient low noise cooling system IP20, Finish – Black , Certification: CE.
229Supply, Installation, Testing and Commissioning of MOVING HEAD : Power voltage : AC100- 240V , 50/60Hz,Power consumption : 250W,Color temperature : 8500k,Beam Angle : 0° -3.8° (by aperture}, Pan/Tilt : 540°/250°,DMX channel mode : 16 channels, Color Wheel : 14 colors plus white with rainbow effect, Gobo wheel : 1 fixed gobo wheel with 17 gobos plus open, Prism : 8/16/24 facet prism rotating in both directions, Focus : Motorized focus ,Frost : 0- 100%,Display : LCD display Power Socket : Powercon in.
230Supply, Installation, Testing and Commissioning of WW/CW LED PAR : 150W LED , CCT: TW- 3200K/TC-5600K, Ra) 93,voltage : ac-100- 240v, 50/60Hz, Max Power 143, Power Connection : Power in and out, DMX XLR : DMX SPLITTER IN/OUT.IP 65.
231Supply, Installation, Testing and Commissioning of LED BATTEN FOR CURTAIN: Body Material Aluminum alloy structure, Product size 1000mm × 59mm × 116mm, Voltage AC100-240V 50/60Hz Input Power 200W, Lamp Type 18pcs x 10W LEDs Average Life Span 50,000h, Color System 18pcs RGBW 4 in 1 ,Color Temperature 2700K~8000K, Control Channel 8/72/76 control channel modes, Control Mode Standard DMX512, Master/Slave control mode, Sound Active, Auto Run Menu Display LED display, DMX Signal Connection 3-pin XLR In/Out, Beam Angle 25°, 40°(Optional) Working Temperature -20-40?.
232Supply, Installation, Testing and Commissioning of LED FLOOD LIGHT:LIGHT SOURCE: 70W -100W, Integrated design - means the case never needs to be opened Long lifetime - no bulb replacements plus 70% light output maintenance to 30,000 hours Slimline - main body is 40mm thick. High efficiency - around 85 lumens/watt (4,300lm) More robust .TYPE: MSSP- LED 100W etc. complete as required.
233Supply, Installation, Testing and Commissioning of DMX Splitter with one DMX input and 8 buffered outputs and 3 pin / 5 pin XLR connectors.
234Supply, Installation, Testing and Commissioning of LIGHTING CONSOLE: Lighting Console with Internal Flash Drive, similar in functionality to a hard disk but faster and more rugged. Provides enough storage for:- The entire Fixture Library of more than 3,000 files, New Locate Fixture button, Fixture Selects (selecting the top row of faders), 2048 Channels, 240 Intelligent Fixtures,240 Dimmer Control Channels, Theatrical Plotting and Playback functions, Shape Generator for instant creation of patterns and effects, 15 Playback Masters controlling 450 memories, chases or cue lists, MIDI and Bass, Mid, Treble sound to light triggers, Colour VGA output fitted as standard, Front panel now reverse printed Poly Carbonate Laminate using technology from the Diamond 4, this is incredibly hard wearing and looks excellent, Each console individually has an electronic serial , Supplied with PC applications: Avolites Visualizer, Pearl Simulation program and Cache Builder.
235Supply, Installation, Testing and Commissioning of DMX loop point wiring with all required connectors from splitter to all lighting fixtures.
236Supply, Installation, Testing and Commissioning of Light Point Wiring from Patch Panel to be Provided near stage to various stage light fixtures with 2.5 Sq.mm 3 Core PVC Insulated and PVC Sheathed Cable including Cable Tray of suitable size for laying these wires on the tray including 15-20 amps metallic clad sockets with box at top etc. complete as required.
237Supply, Installation, Testing and Commissioning of foot power point etc. as required.
238Supply, Installation, Testing and Commissioning of Suspender cum clamps designed made out of MS material 150mm x 150mm x 5mm MS Base plate Threaded rod, Black powder coated finish All the materials under gone through 7 tank process with various chemical treatment to keep them rust free Suitable to hold various type grid and other rigging systems.
239Supply, Installation, Testing and Commissioning of Light Fixture dual safety Chain made up of GI wire rope Bundled and twisted together Having load bearing capacity above 200 Kgs.
240Supply, Installation, Testing and Commissioning of Analogue Addressable type Smoke Detector with Visible bi-color LEDs for 360 deg having Rotary, decimal addressing system in the range of 01-159, complete with standard base, as required, complying to EN54 and LPCB/UL.
241Supply, Installation, Testing and Commissioning of Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Switches for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/UL.
242Supply, Installation, Testing and Commissioning of Sounder cum strobes with 3 different tone variants selection options and adjustable sound pressure by 3 levels, the sound pressure 92 dB(A), Sounder should have IP40 or better protection rating. with flasher having Synchronized flash rate of 1 Hz and Light intensity 15cd- 185cd. Shall be UL/EN/VDS Certified.
243Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU`s, tripping of AHU`s, Fresh air fans, Ventilation fans, tripping of Access control doors etc.. Shall be EN54/ Vds Certification/ UL.
244Supply, Installation, Testing and Commissioning of Ball Valve assembly with suction dryer.
245Supply, Installation, Testing and Commissioning of Separation Tubes of various shapes for AHU.
246Supply, Installation, Testing and Commissioning of Wired Remotes Touch screen panel.
247Supply, Instillation, Testing and Commissioning of Control kit for AHU.
248Supply, Installation, Testing and Commissioning of Electronics Extension Valve Kits For AHU.
249Providing and fixing SWR PVC Nanhi trap with jali (110x110mm).
250Providing and fixing SWR UPVC SWR P-trap (DS) 110x110mm dia complete in all respect.
251Providing and fixing SWR UPVC Coupler/ Socket 110mm dia..
252Providing and fixing SWR UPVC Bend with Door 110mm dia..
253Providing and fixing CPVC Tank Connector 32mm dia
254Providing and fixing 40mm dia CPVC ball valve (union type) complete in all respect
255Supply, Laying, testing and commissioning of FRLS XLPE armoured cables for Electrical Power and controls from MCC/LSCP/PDB to respective Equipments with earthing, clamped on surface or on cable trays, structural supports and cable supports provided. The scope includes End Termination of cables with Double Compression type Brass Cable Glands and Copper Lugs, clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out of GI. strip 3 mm thick, treasing and Clamping of Cable on cable tray or surface, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium/PVC laminated strip and 75x20 mm in size with cable number and size punched on it. Cable tags shall be tied to cables at every 20 meter interval and at both the ends. MS Powder Coated Junction Boxes with Bolted type terminals of suitabel size shall be provided near all Fan Motors for termination of armoured cables...(i) 4C x 6 Sqmm Copper Cable
256Supply, Installation, Testing and Commissioning of UL Certified Linear pneumatic Heat Detection Tube (ID-6mm and OD-8mm) for automatic fire detection and suppression system made by special modified polyimide (PA), colour red RAL300, burst temperature 1310C, inner diameter 6mm, outer diameter 8mm. Pressurized with dry nitrogen at 15 bar pressure with all necessary fittings and supports. Certified by National Test House, Dept of Consumer Affairs, Govt. of India.
257Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP. Two loop
258Supply, Installation, Testing and Commissioning of 1/2 Way MS lighting junction box made up of 16SWG CRCA sheet undergone through various chemical treatment to keep them rust free and duly finished with black powder coated paint in black matt finish and5/15A Anchor or IEC Socket with suitable glands
259SITC of Post top Lighting Pole of 4m-4.2m Height made out MS Pipe Ø76.1mm confirming to YSt 210 and facilitating the luminaire mounting at the top. The pole shall be surface mounted on a pre-formed foundation. The base plate of the of the pole shall be E 250 grade MS 200 mm x 200mm, 12mm thick confirming to IS2062:2011 shall be facilitated with elongated slots to suit the 300mm, J-type, M16 bolts, Grade 4.6 that shall be provided with suitable nuts and plain washers. The structurally sound pole emerging out of the base plate shall be architecturally designed with a decorative cast aluminum causeway base cover Ø330mm x 806mm(H) or Ø330mm x 625mm, the grade of pressure die-cast material shall be ADC12. A GDC embellishment is provided at appropriate height enhancing the decorative outlook of the pole. The grade of gravity die cast material shall be LM6. The Pole welding shall be done with certified welders using a V groove technique with a high end MIG welding process. A base compartment with a die cast aluminum door contoured to the polis`s shape housing the gear tray, prewired with 2 way connector The surface preparation of the pole and components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zilch rich primer coat and pure polyester powder coating or epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Any other wiring/electrical consumables shall be under the scope of purchaser complete in all respect up to the entire satisfaction of Engineer - in - charge of the work including making necessary connections etc.
260Supply, Installation, Testing and Commissioning of 24 Port PoE L2 Managed Switch with SFP module1. Port Standards• IEEE 802.3 10BASE-T Ethernet (twisted-pair copper)• IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-paircopper)• IEEE 802.3u 100BASE-FX 100 Mbps over fiber optic• IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-paircopper)• IEEE 802.3z 1000BASE-X 1 Gbps over fiber optic• IEEE 802.3az Energy Efficient Ethernet (EEE)• IEEE 802.3x Flow Control• JEEE 802.3af/at compliance (for PoE ports)2. Interface: 24 x 10/100/1000BASE-T PoE Ports and4100/1000 Mbps GbE/SFP combo ports3. Duplex Mode:• Full/Half-duplex for 10/100 Mbps• Full-duplex for 1000 Mbps4. Media Interface Exchange: Auto MDI/MDIX adjustment forall twisted-pair ports5. Switching Capacity: 56 Gbps6. MAC Address Table: 8K entries7. Static MAC Addresses: 256 entries8. Memory:CPU Memory:DDR3 128 MB9. Power Budget: 193W or higher10. LED indications:Power (per device). Link/Active/Speed (per port). PWR Max.Fan Error11. Power Input: 100 to 240 V AC 50/60 Hz, internal universalPower supply12. Fan13. Operating Temperature -5ºC to 50ºC Make D Link / Netgear/Cisco
261Supply, Installation, Testing and Commissioning of 250M HDMI Extender with TCP/IP, Usage/ ApplicationProjectors, Connector Type Male, Brand Line Tek, Interface Type HDMI/ LAN TX/ RX. MAKE – MILESTONE, TENDA
262SITC of Wall Fan 16`` Sweep ( 400mm) oscillating type light duty Rated speed 1350 RPM with inbuilt regulator, blade, jaalli, Copper wound Motor, PVC body 03 no. blade. Power Consumption 57w.Air Delivery 65m³/min 2 years warranty Complete in all Respect.
263Supply and Erection of 2.5 Sqmmx3 core PVC insulated multi core copper conductor cable (armored) 1100 volts with 3 Core (Typically Phase, Neutral, and Earth), PVC (Polyvinyl Chloride) - Type A or C, Galvanized Steel Wire/Strip (Provides mechanical protection) etc.with all accessories complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work.
264Supply and Erection of 10m HDMI 2.0 Cable. High-Speed HDMI with Ethernet (Category 2). 10.0 Meters (32.8 feet). Full 18Gbps (supports HDMI 2.0b standards). 4K @ 60Hz (4:4:4) Ultra HD. ARC (Audio Return Channel), Dolby Atoms and up to 32 audio channels. 19-pin HDMI Type-A Male to Male. Gold-plated connectors to resist corrosion and ensure low contact resistance. Zinc Alloy or heavy-duty PVC Molded shell with strain relief. Minimum 24 AWG or 26 AWG Oxygen-Free Copper (OFC) to minimize signal attenuation over the 10m distance. Triple-layer shielding EMI/RFI protection. UL-listed, fire-retardant PVC or CL3-rated (safe for in-wall installation). HDCP Compliance HDCP 2.2 / 1.4, Color Depth 48-bit Deep Color, Outer Diameter Approx. 8.5 mm to 10.0 mm., Compliance RoHS, CE, FCC.complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work.
265Supply and Erection of Cable Assembly for conference system 10 or more Mtr, Difference types of Cable use in conference system Likes Active HDMI (AOC) Direct connection from laptop to a far projector, HDBaseT (Cat6) Complex setups with Power-over-Ethernet (PoE) and control., SDI (Coax) Broadcast-quality video or permanent wall-mounted cameras., XLR Long-distance microphone runs to a mixer. complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: - Bosch/ Televic/ Brahler.
266PROVIDINGand ERECTION/ LAYING OF 16 SQMM 4 CORE PVC/ XLPE INSULATED COPPER CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK.
267Supply, installation, testing and commissioning 6 Watt RMS speaker suitable for fire alarm and voice evacuation/public address systems, having rated power output of 6 W RMS with provision for multiple wattage tapping (e.g., 6/3/1.5 W) through built-in line matching transformer, designed for 100 V line operation, delivering clear and intelligible sound with wide frequency response (approx. 100 Hz to 10 kHz) and sound pressure level adequate for indoor coverage: the speaker shall be ceiling/wall mount type as required complete in all respect.
268Supply and Erection of Addressable Manual Call pull type BOX suitable for intelligent fire alarm systems, designed for manual initiation of fire alarm by pull down lever operation, with resettable mechanism using key (non-break glass type preferred) complete in all respect.
269SITC of High Power 2-Way Loudspeaker with 1 x 15” LF and Rotatable Horn: Coverage Pattern: 90° x 50° ormore with rotatable waveguide: Frequency Range 34Hz–20kHz orbetter: Maximum SPL (Peak) 130dB ormore: Passive Crossover Frequency: 1.2kHz: Sensitivity 96dB SPL: Power rating (peak) 2400W ormore: Impedance 8 Ohms: Should support Bi-amp mode and Passive mode switchable: Should have 15 ormore M10 points for suspension: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work
270SITC of High Power 2-Way Loudspeaker with 1 x 15” LF and Rotatable Horn: Coverage Pattern: 60° x 40° ormore with rotatable waveguide: Frequency Range 34Hz–20kHz orbetter: Maximum SPL (Peak) 130dB ormore: Passive Crossover Frequency: 1.8kHz: Sensitivity 96dB SPL: Power rating (peak) 2400W or more: Impedance 8 Ohms: Should support Bi-amp mode and Passive mode switchable: Should have 15 or more M10 points for suspension: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
271SITC of High Power 2-Way Loudspeaker with 1 x 15” LF and Rotatable Horn: Coverage Pattern: 120° x 60° or more with rotatable waveguide: Frequency Range 34Hz–20kHz or better: Maximum SPL (Peak) 130dB or more: Passive Crossover Frequency: 1.4kHz: Sensitivity 96dB SPL: Power rating (peak) 2400W or more: Impedance 8 Ohms: Should support Bi-amp mode and Passive mode switchable: Should have 15 or more M10 points for suspension: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
272SITC of Compact Two -way Loudspeaker with 2 x 8” orbetter LF Driver: Power rating (pk) 1500W ormore: Impedance 8 Ohms: Coverage Pattern 120° x 60° or better: Frequency Range 54Hz-20kHz or more, Frequency Response 65Hz-20kHz ormore: Max SPL 120dB ormore: System Sensitivity 94dB SPL or more: Crossover: 2.1kHz and with OEM specific wall mount bracket: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
273SITC of Two Way 8 inch - 10 inch LF, Compact Wall Loudspeaker for indoor and outdoor uses with Frequency Range 47Hz–19kHz or more: Power rating 90Watts - 100Watts Continuous or more: Max SPL (pk) 118dB or better: Should have 70/100V Transformer taps 60W, 30W, 15W or more: 100-120 degree (H) x 100-120 degree (V) or better coverage: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
274SITC of High Power Subwoofer with Dual 18` - 21` or better: Frequency Range: 28Hz–1kHz or better: Power Rating (pk) : 9600W or better: Max SPL 142dB or better: Sensitivity 102dB ormore: Impedance: 4 Ohms: Should support Drivers Parallel / Drivers Discrete mode for better performance: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
275SITC of Dual channel Digital Network Based Power Amplifier with per channel power output 2400W @ 4 Ohms: should support 70Vrms and 100Vrms output on all channels: THD 0.35% or better: Should support Cooling Continuously variable speed forced air: Voltage Gain 34dB or more: Digital bus compatibility up to 8 or more audio channel: bridgeable channels - even in 100Vrms mode for 200Vrms Output: 2digital audio bus RJ45 port: 1 Ethernet R 45 port for monitoring and configuration: Should have DSP features incl. Limiters , Input/output EQ , Delay ,Matrix Mixer ,Speaker Line Monitoring: Damping Factor (20 Hz to 100 Hz) : )5000 or more: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
276SITC of Dual channel Digital Network Based Power Amplifier with Power output 600W ormore @ 8 Ohms: Should support 70Vrms and 100Vrms output on all channels: THD 0.35% orbetter: Should support Cooling Continuously variable speed forced air: Voltage Gain 34dB ormore: Digital bus compatibility up to 8 or more audio channel: bridgeable channels even in 100Vrms mode to operate with 200Vrms output: 2digital audio bus RJ 45 port: 1 Ethernet R 45 port for monitoring and configuration: Should have DSP features like Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring: Damping Factor (20 Hz to 100 Hz) : )1000 ormore: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
277SITC of Networked Digital Signal Processor with 12 ormore inputs and 8 or more outputs or more: 12 ormore Control Inputs and 6 or more Logic Outputs for GPIO Integration: 48V phantom power on all analog inputs: THD: (0.01% 20Hz to 20KHz: Crosstalk: (-75dB orbetter: Open architecture software configurable: Separate logic processing power: 2 digital audio bus RJ45 Port: 1 Ethernet port for Monitoring and configuration: Capable to handle plus 5V unloaded logic output voltage: Should have speech sense engine: Capable to control 3rd party devices with TCP IP and RS232: Should have 1nos of RS 232 port for integration with control System: Should have Bi-Directional Locate Functionality: Should have 48 or more digital audio Channel Bus: Should have monitoring LED for COM, STAT, ERR and PWR: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
278SITC of 32 Channel Digital mixing console with 32-in/32-out USB Interface: should support wireless / Wi-Fi Openerations Via iPad Control: Should support Minium 40 Mic/Line Inputs: 31 ormore Output busses: 8 VCAs plus 8 Mute groups: 26 or more motorized faders: Should comes with 5.0inch diaongal or more touchscreen display: should Support MADI/ Dante/ cobranet Cards for digital audio routing over an ethernet cable: 20 ormore sub-group / aux busses: Multi Color LCD Channel Displays on each input fader: 4 or more studio-grade Effects engines and dedicated FX busses: 4 or more mono/stereo matrix busses: Up to 80 or more channels to mix: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work
279SITC of Wireless Handheld Microphone System with MHzcarrier frequency band, Up to 16 ormore pre-programmed frequencies within the same frequency band: Audio bandwidth 35-20000Hz orbetter: THD at 1 kHz: (0.3% (Receiver): Signal-to-noise: 120 dB(A) ( Receiver): Wideband FM Modulation: Up to 48 ormore Simultaneous channels: Upto 14 or more hours operation with one single AA battery or better: Pilot Tone transmission to know the transmitter battery status: Receiver should have microphone level and line level output: Transmitter should have display to show the battery and LED to show the Muted /Unmuted status: Sensitivity 6.3 dB V / -100 dBm orbetter: Should have Microprocessor controlled diversity: T.H.D. 0.7% or better (Transmitter): Infrared programmable: RF output power: 50mW ormore: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
280SITC of wired Vocal microphone Should be Professional Dynamic Handheld Microphone and On/Off Switch: should support Polar Pattern supercardioid orbetter Audio Frequency bandwidth 70 to 20000Hz ormore: Sensitivity 2.6 mV/Pa or better: Electrical Impedance : 600 Ohms or better: Recommended Load Impedance : 2000 Ohms or more: Connector Type : 3-pin XLR Male (Balanced): Metal Body etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
281SITC of Wired Dynamic Instrument Microphone with Cardioid orbetter Dynamic Instrument Microphone: Audio frequency bandwidth 40-20000Hz ormore: Sensitivity 2.5 mV/Pa or more: Max. SPL 47dB or more: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
282SITC of Wired Gooseneck Microphone with Desktop base unit for portable podium uses. It should support Cardioid or better polar pattern: built-in on/off switch: Audio frequency bandwidth 70-18000Hz ormore: Signal to Noise 64dB-A orbetter: 500mm (50cm) or more in Length: 9 to 52V Power Interface: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
283SITC of Big mic stand with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work
284SITC of Professional direct injection box: should support features like Premium Performance: Rugged Design: Stackable Chassis with Durable Rubber Foot: Gold-plated Neutrik XLR Connector: 3-Way 0/20/40 dB Pad Switch: plus 48V Phantom Powered Operation: Green LED Phantom Power Indicator: Low-Noise Active Circuitry: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
285SITC of 12` Two-Way Self-Powered Stage Monitor Loudspeaker System: should support Power rating 2000W(pk) ormore: Frequency Range 51Hz – 20kHz orbetter: Max. SPL 132dB or more: Coverage Pattern 100° x 60° or better: Crossover Frequency: 2000Hz: 100V - 240V ~ 50/60 Hz Operation: Should support audio connectivity with minium 2 x XLR balanced Combo jacks: XLR-M loop-through: should support Bluetooth 5.0 or latest for streaming and control: etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
286SITC of 4x24 K60 HDMI Switcher with Scalar, Shall have Minimum 4HD MI input sand Minimum 2HDMI outputs, pixel-for pixel vide ore production, EDID management, automatic or manual switching modes, HDR10, HDR10 plus , Dolby Vision, HDMI2.0, HDCP2.2, High Dynamic Range (HDR) and 36-bitper pixel Deep Color. Shall have analogy au diode – bedding from each HDMI output separately, Data rate: 18GBP,Pixel Clock: Up to 600 Mhz, should have built-in / external 4K Video resolution Scalar etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
287SITC of 4K604:4:4 Twisted Pair Transmitter and Receiver ,Should supports traditional HD Base T Outputs, and HDMI as an inputs: Shall have on board USB 2.0 available on the HDBT allows for easy distribution of USB signals between the transmitter and receiver. AUSB device, such as conferencing sound bar, can be mounted at the display and connected to a receiver. A laptop can the connect to the transmitter at the table, with USB and video distributed over category cable. It should support long distance transport of Ultrahigh resolution video, embedded audio, bi-directional RS-232 and IR and USB 2.0 over a single category cable. 4K604:4:4 and HDCP 2.2 Support over HD Base T with Display Stream Compression (DSC)–Visually loss less compression and future-proof support, Twisted Pair Cable Type Shielded Cat6, Cat6A and Cat7/Shielded Cat6A and Cat7, Twisted Pair Cable Length Up to 70m-100 m or more, HD Base T Layer Throughput (Max) 10.2Gbps, Shall have 1xHDMI ,1xHDBT Output, Shall serial port, Shall have IR TX and RX ports, Input Signal Type HDMI, HDCPDVI, Data Rate (Max):18Gbp, Pixel Clock (Max) Up to 600MHz, Regulatory Compliance CE, FCC, NRTL, RoHS, WEEE etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work.
288SITC of Hanging Frame with Extension for Subwoofer, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
289SITC of Digital Podium Motorized Podium, Touch Screen 21.5 inch (IR, Overlap), i5 Core Processor (12th Generation), 8 GB RAM, Hard Disk 512 SSD) HDMI Plate for Projector, keyboard mouse with tray plus sliding drawers to keep document camera or books , Control Panel (with HDMI, VGA, USB, Audio in and Out, Aux in and 220 v power supply for Laptop , Mobile charging) with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
290SITC of 1-Chip10000 lumens WUXGA DLP Projector, 16:10 aspect ratio, Number of pixels - 2,304,000 (1920 x 1200 pixels), Light source - Laser phosphor, light source lifetime - 20,000 hours, Contrast ratio - 6,000:1 ( Dynamic Contrast, Center-to corner zone ratio -90 %, Lens - , Optional powered zoom/focus lenses, Inputs : 3G-SDI, 2x HDMI, DVI-D and RGB. Control Ports : RS232 and LAN. Operating Temperature : 0-45 C (32-113F). Power Consumption APPROX 970W.Features: HD Base T, back up input, , 360 degree projection, motorized lens shift support 4K input, Free grid function to correct the distortion without using PC along with suitable long throw lens with zero offset and accessories short throw lens 0.6 to 1.0:1 with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
291SITC of ceiling mount kit with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
292SITC of 4x4 4K HDR HDMI HDCP 2.2 Matrix Switcher with Audio De–embedding, High–Performance AV Matrix - Switches Resolutions up to 4K60 (4:4:4), INPUTS - 4 HDMI: On female HDMI connectors, OUTPUTS - 4 HDMI: On female HDMI connectors, 4 S/PDIF: On female RCA connectors, 4 Balanced Stereo Audio: On 5–pin terminal block connectors, PORTS -1 USB: On a Mini female connector, 1 RS-232: On a 9–pin D–sub connector, 1 IR IN: On a 3.5mm mini jack, 1 Ethernet: On an RJ–45 female connector, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
293SITC of Speakor Connectors, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
294SITC of Speaker NL 8 Connectors, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
295SITC of XLR Male Connectors, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
296SITC of XLR Female Connectors, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
297SITC of XLR female Base Connectors, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
298SITC of 42U Equipment Rack with provision for housing all control equipment with front and rear door, Blower for cooling and proper locking arrangements, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
299SITC of HDMI Face plate, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
300SITC of 8 CORE SNAKE CABLE, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
301SITC of Phono Connectors, with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work.
302SITC of LED Post Top Luminaire (45–50 W) complete with built-in LED module, suitable for mounting on a Ø76 mm OD pole. The luminaire shall operate on 240 VAC, with CCT options of 3000 K, 4000 K, or 5700 K, minimum CRI 80, MacAdam Step 3, and minimum system efficacy of 120 lm/W. It shall have 360° light distribution, IP65 protection, ON/OFF electronic driver with minimum 88% efficiency, power factor =0.96, THD =10%, and 6 kV surge protection. Housing shall be of die-cast/spun aluminium with clear acrylic diffuser, stainless steel fasteners, and polyester powder-coated finish. The luminaire shall have an L70B10 life of at least 50,000 hours at 40°C, operating temperature from –15°C to plus 50°C, and comply with LM-79, LM-80, TM-21, and BIS certification, complete with all accessories, installation, testing, commissioning, and satisfactory operation as directed by the Engineer-in-Charge.
303SITC of 150 ltr capacity water cooler having fully stainless steel corrosion resistance (grade SS304) body with puff insulation, 150/150 ltr i.e. 150 ltr per hour cooling and 150 ltr water storage capacity, R134a refrigerant type, water tank sheet thickness )= 0.6 mm, Cooler Cabinet sheet thickness: 0.8mm (min), Water tank cover and lid bottom sheet material: High Impact Polystyrene (HIP) and Thickness:1.5mm (min) , Number of faucet-02, Two drainpipes shall be metallic or PVC (Poly Vinyl Chloride) , Plastic used in storage tank or in any part coming in contact with water shall be of food grade. Warranty on machine: 2 years. Warranty on compressor- 5 year, BIS Certification as per IS-1475 (Latest) complete in all respect with making necessary connections and work shall be done as per entire satisfaction of Engineer-in-charge. Make USHA/ /Climatrol or approved brand list of HPHC
304SITC of 50 LPH (50 ltr per hour) capacity RO, Commercial type including Pre-filters complete in all respect with making necessary connections, should be suitable for raw water TDS upto 2000 ppm, the water should be filtered with PH value (range minimum 6.5 to maximum 8.0), TDS should be less than 100 ppm, recovery should be greater than 40%, and work shall be done as per entire satisfaction of Engineer-in-charge.
305Supply and erection of 2200 VA (volt- amp) or above rating double battery Sine wave inverter along with built in input MCB for short -circuit and overload protection instead of just a glass fuse having CCCV or 3-stage charging, Input Voltage Range: 140V – 300V AC, Output Voltage: 220–240V AC ±10% , Frequency: 50 Hz ± 0.5 Hz , Transfer Time: (10 ms (UPS mode), LED/LCD display, automatic changeover, and complete protections including overload, short circuit, deep discharge, and overcharge protection, conforming to IS 16242/IEC 62040, BIS certified, Efficiency: =85–95% and THD (Total Harmonic Distortion): (3–5% having warranty of minimum 24 months with 2 nos 12/24V tubular type batteries of rating 200 Ah (Amp – hours ) each 48 months warranty including MS stand / trolley complete in all respect.
306Supply, Installation, Testing and Commissioning (SITC) of Industrial Wall Air Circulator Fan of approved make such as Wall Air Circulator Model, 600 mm (24`) sweep, heavy-duty wall/column mounted type with pedestal bracket, complete with aerodynamically balanced 3-blade aluminium impeller, suitable for continuous industrial operation. The fan shall have a 200 W motor, operate on 230–240 V, Single Phase, 50 Hz AC supply, with a speed of 1440 RPM, 3-speed control, and minimum air delivery of 16,000 m³/hr (approximately 9,417 CFM). The fan shall be suitable for indoor/outdoor installation and shall include all mounting brackets, clamps, anchor fasteners, connection accessories, wiring from the nearest electrical point to the fan. The fan shall be supplied with a minimum 2-year manufacturer`s warranty on the motor complete in all respects upto the entire satisfaction of Engineer in Charge.
307Supplying and fixing of following size Wall MountRack having Fixed Structure with 0.8mm CRCASheet, completely knocked-down condition (CKD)Shape, Vertical Mounting Rail 1.6 mm with `U` Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL and RoHS, 2 x 6 sockets 16A power distribution units, 3 numbersclosed cable organizer, Hardware mounting screwspacket of 20 x 1 number, etc. complete as required 6U as per DSR
308Supplying, Installation, Testing and Commissioningfollowing capacity Serveillance grade Hard Disk withupto 256MB/s Transfer Rate, 256 MB Cache, 7200RPM Disk Speed, 3.5 inch form factor, SATAInterface, BSMI, ICES-003/NNB-003, CE, FCC, KC,Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, ULCertifications. as per DSR 40.12.4 10TB (Terabytes)
309Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrialgrade with 3840x2160 resolution or better, USBplayback, bluetooth and miracast connectivity, 4XHDMI 2.0, DP 1.2, HDR 10/10 plus , brightness: 500-nits or better, Video wall mode should be available,contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Displaycontrol shall be on monitor screen and programmablewith remote (remote shall be supplied with system),Key Board, Optical Mouse, etc. as required. as per DSR 42.4.3 55 inch or larger
310Supplying Installation Testing and Commissioning of5MP/6 MP IP IR Bullet Camera having followingspecifications, type of lens and features etc :-1) Type of Camera: Bullet Camera2) Image Sensor: 1/2.8` or better progressive ScanCMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON,0 lux with IR or better5) Imaging: 1/3s to 1/30000s, Auto Gain Control ,White Balance- Auto, Back Light Compensation, Multizone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should displayCamera title, Date and Time in live and recorded videoboth.7) Signal to Noise Ratio: ) 50 dB8) Lens Type and Focus: as given below.9) Day and Night: True Day and Night High PerformanceMechanical IR cut filter with auto switch, IR SourceInbuilt IR LED`s with effective distance upto 50 Mtrsintegrated IR and 30 Mtrs for colour view in night.10) Video Compression (Minimum): H.265 or better,Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72311) Wide Dynamic Range: WDR (120dB or more)12) Digital Noise Reduction: DNR (2D/3D) On/Off13) Streaming: Triple streaming, configurable14) Video Streaming and Frame Rates: Triple streaming, configurable Main stream: 5MP/6MP @25/30 fps,Sub streams: D1@25/30 fps or better15) Image Setting: Rotate Mode, saturation,brightness, contrast, sharpness adjustable throughclient software or web browser16) Profile Management: User configuration import,export17) Security: User Authentication, Digital WaterMarking18) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.19) Recording Management: Format SD, overwrite,storage management, video to NAS device,20) Edge Analytics: Tripwire, Intrusion, MotionDetection21) Alarm Trigger : Motion/tampering detection:network disconnection detection: IP conflict detection:memory card state detection: memory space detection22) Alarm Support: It should have 1/1 Alarm In/ OutPort23) Audio Support: It should have 1x Built-In Mic and1/1 Audio In/ Out Port for external Mic. and Speaker(As per site requirement) with G.711U/A / G.711Mu/AAC/ G.726 audio compreesion24) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,25) System Capability: ONVIF26) VMS: Camera shall support open source VMS27) Cyber Security: trusted boot, AES 256-bitEncryption, Configuration encryption, trustedexecution, Digest, security logs, account lockout, ,video encryption, IP/MAC filtering, HTTPS, trustedupgrade.28) Ethernet: 1 RJ 45 10/100 Ethernet port29) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via poweradapter) and PoE—to ensure continuous operation inthe event of a failure in one power source.30) Power Requirement: 12VDC/24V DC/PoE(802.3af)/ePoE31) Enclosure: IP67 weather proof, IK1032) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)33) IR life: 40000 hours or higher34) Video Bit rate: 32 KBPS - 8 MBPS or better35) Standards: BIS with ER, STQC Certified, CE, FCCand RoHS as per DSR 40.6.1 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as persite requirement) outdoor bullet Camera
311Supplying Installation Testing and Commissioning of5/6MP IP IR Dome Camera having followingspecifications and features etc :-1)Type of Camera: Dome Camera2) Image Sensor: 1/2.8` or better progressive ScanCMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0lux with IR or better5) Imaging: 1/3s to 1/30000s Shutter Support, AutoGain Control , White Balance- Auto, Back LightCompensation, Multi zone Privacy Masking, HLC,Digital Watermarking.6) On Screen Display: Camera should display Cameratitle, Date and Time in live and recorded video both.7) Signal to Noise Ratio: ) 50 dB8) Day and Night: True Day and Night High PerformanceMechanical IR cut filter with auto switch, IR SourceInbuilt IR LED`s with effective distance upto 50 Mtrsintegrated IR 30 Mtrs for colour view in night.9) Video Compression (Minimum): H.265 or better,Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming and Frame Rates: Triple streaming, configurableMain stream: 5/6MP @25/30 fps, Sub streams:D1@25/30 fps or better14) Image Setting: Rotate Mode, saturation,brightness, contrast, sharpness adjustable throughclient software or web browser15) Profile Management: User configuration import,export16) Security: User Authentication, Water Marking17) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.18) Recording Management: Format SD, overwrite,storage management, video to NAS device,19) Edge Analytics : Tripwire, Intrusion, MotionDetection20) Alarm Trigger : Motion/tampering detection:network disconnection detection: IP conflict detection:memory card state detection: memory space detection21) Alarm Support: It should have 1/1 Alarm In/ OutPort22) Audio Support: It should have 1x Built-In Mic and1/1 Audio In/ Out Port for external Mic. and Speaker(As per site requirement) with G.711U/A/ G.711Mu/AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast,24) System Capability: ONVIF25) VMS: Camera shall support open source VMS26) Cyber Security: trusted boot, AES 256-bitEncryption, Configuration encryption, trustedexecution, Digest, security logs, , account lockout,video encryption, IP/MAC filtering, HTTPS, trustedupgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via poweradapter) and PoE—to ensure continuous operation inthe event of a failure in one power source.29) Power Requirement: 12VDC/24VDC/PoE(802.3af)/ePoE30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCCand RoHSas per DSR 40.5.1 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as persite requirement) Dome Camera.
312Supplying Installation Testing and Commissioning ofPTZ (Pan, Tilt and Zoom) IP IR Camera havingfollowing specifications and features etc :-1) IP IR PTZ Camera: Motorized PAN TILT ZOOMwith IR2) Image Sensor: 1/2.8` or better progressive ScanCMOS3)Signal System: PAL/NTSC4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,,0 lux with IR, or better5) Imaging: 1/1s to 1/30000s, Auto Gain Control ,White Balance- Auto, Back Light Compensation,Image Rotation, Multi zone Privacy Masking (Upto 24Area), HLC, Defog, Region Of Interest and EISfeatures.6) On Screen Display: Camera should display Cameratitle, Date and Time in live and recorded video both.7) Signal to Noise Ratio: ) 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day and Night: True Day and Night High PerformanceMechanical IR cut filter with auto switch, IR Source Inbuilt IR LED`s with effective distance. The camerashould have IR LED’s and cover distance up to 300meter or above10) Auto Tracking: The camera should be equippedwith Deep-learning-based auto tracking function usingsimultaneously all of the panning, tilting and zoomingshould be available. When a motion is detected in aregistered monitoring area, the camera should trackthe motion (object) and capture it.11) Pre/Post Event Buffering: The camera shouldsupport atl east of 5 seconds of pre and post eventbuffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better,H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC,G.72314) Wide Dynamic Range: WDR (120dB or more),HLC and BLC15) Digital Noise Reduction: DNR (2D plus 3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog,saturation, brightness, contrast, sharpness adjustablethrough client software or web browser17) Profile Management: User configuration import,export18) Cyber Security: Configuration encryption, AES256-bit Encryption, Digest, account lockout, videoencryption, IP/MAC filtering, trusted boot, trustedupgrade, trusted execution19) Onboard Storage: Camera should support built inMicro SD/SDHC/SDXC Card slot upto 512 GB . Itshould be supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite,storage management, video to NAS device, remotearchive access via FTP login21) Edge based Video Analytics and Alarm Trigger:Motion/tampering detection: network disconnectiondetection: IP conflict detection: memory card statedetection: memory space detection, Tripwire,Intrusion, Object Abandon/ Missing, SMD, FaceDetection22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP,HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP,DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G and T. CCTVCamera OEM should be fulltime member of ONVIFand quoted models should be listed on ONVIF officialwebsite (All the certifications and Credentials should bevalid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camerashould have 1/1 Audio In/Out to connect External Micand Speaker Audio Compression : PCM, G.711U/A,G.711MU, G.726, MPEG2-Layer2, G.722.127) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should supportsimultaneous dual power input—DC/ AC (via poweradapter) and PoE (802.3af)—to ensure continuousoperation in the event of a failure in one power source.29) Power Requirement: 24 VDC, 2.5 A (± 25%),PoE plus (802.3at)30) Enclosure and Weather Proof Standard: IP67weather proof and IK10, TVS 8000V lightning proof,surge protection, voltage transient protection31) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCCand RoHS as per DSR 40.9.2 4MP@25/30 fps Sub streams:1080p@25/30 fps and D1@25/30 fps or better, varifocallens 4.5-135mm or better with Automatic and manualFocus Adjustment provisions, 30x Optical zoom and12x Digital zoom with angle of view H : 57°–2.4°, m,PAN Travel: Pan: 0° ~ 360° endless: Manual Pan: 300°/s, Preset : 300° /s, Tilt Travel: Tilt: 0-90°, auto flip180°, Manual Tilt: 200° /s, Preset : 300° /s.
313Supply, Installation, Testing and Commissioning (SITC) of 12W Square Decorative Laser-Cut Designer LED Bollard Luminaire complete with all accessories, foundation bolts, mounting hardware, wiring connections, testing and commissioning, conforming to the following minimum specifications:Rated Power: 12 W (System Wattage)Input Voltage: 220–240V AC, 50 HzCCT: Selectable/Available in 3000K / 4000K / 6500KInitial Luminous Flux: Minimum 1200 lumensLuminaire Efficacy: Minimum 100 lm/WColour Rendering Index (CRI): =80SDCM (MacAdam): =3Light Distribution: Symmetrical with controlled downward light emissionLuminaire Height: Approximately 910 mmHousing: Extruded Aluminium Alloy Grade 6063 square tube of 150 × 150 mm, minimum 3 mm wall thickness with valid material test certificate.Laser Cut Design: Bespoke decorative laser-cut patterns.Mounting Plate: Die-cast aluminium base plate 150 × 150 × 4 mm minimum thickness with 3 elongated holes (20 × 12 mm) suitable for M10 foundation bolts on 90 mm PCD.Foundation Bolts: Hot dip galvanized (HDG) foundation bolts of suitable size complete with nuts and washers.Fasteners: Stainless Steel (SS304 minimum).Gaskets: Pretreated EPDM black gasket ensuring weatherproof sealing.Diffuser: Optical-grade clear toughened glass of 4 mm minimum thickness.Ingress Protection: Minimum IP66 for complete luminaire and minimum IP65 for LED module.Impact Resistance: Minimum IK06.Surface Finish: Seven-tank pre-treatment followed by pure polyester powder coating suitable for outdoor applications.LED Module: High-efficiency LED modules complying with LM-80 and TM-21 standards.Luminaire Life: Minimum L70B10 = 60,000 hours at ambient temperature of 40°C.Operating Temperature: –15°C to plus 50°C.Driver: Constant current electronic LED driver.Driver Efficiency: Minimum 90%.Power Factor: =0.95.Total Harmonic Distortion (THD): =10%.Surge Protection: Minimum 6 kV integral surge protection.Protection Class: Class-I with proper earthing provision.Photobiological Safety: Exempt Group (RG0) or equivalent.Compliance: BIS Certified. Complete luminaire shall conform to applicable IS/IEC standards for LED luminaires.Testing: Manufacturer`s routine test certificates and NABL accredited laboratory test reports for photometric, electrical and IP/IK performance shall be submitted for approval.The item shall include supply, installation, testing, commissioning, necessary interconnections, mounting hardware, foundation bolts, accessories, complete wiring, and all incidental works required for proper installation and satisfactory operation, complete in all respects, as directed by the Engineer-in-Charge
314Supply, Installation, Testing and Commissioning (SITC) of 4-Channel Class-D DSP Network Power Amplifier (4 × 1250 W RMS) complete with all accessories, mounting hardware, interconnections, software configuration, testing and commissioning, including all labour and material required to complete the work in all respects as per the satisfaction of the Engineer-in-Charge.The amplifier shall conform to the following minimum technical specifications:Amplifier Type: Class-D, DSP-enabled Network Audio Power Amplifier.Number of Channels: 4 Independent Output Channels.Output Power: Minimum 4 × 1250 W RMS per channel at 8 O.Frequency Response: 20 Hz – 20 kHz (±0.25 dB).Signal-to-Noise Ratio (A-weighted): =108 dB.Total Harmonic Distortion (THD): =0.35% at full rated power (20 Hz–20 kHz).Voltage Gain: Minimum 34 dB.Damping Factor (20 Hz–100 Hz): =1500.Load Compatibility: Shall support 2 O to 16 O, including direct drive 70 Vrms and 100 Vrms constant-voltage speaker lines on each channel without external output transformer.Bridge Mode: Channels shall be bridgeable, including operation in 100 Vrms mode to provide 200 Vrms output.Digital Audio Networking: Shall support digital audio bus with minimum 8 audio channels.Network Connectivity:Minimum 02 RJ-45 Digital Audio Bus Ports.Minimum 01 RJ-45 Ethernet Port for monitoring, configuration and diagnostics.Integrated DSP Features: Shall include, but not be limited to:Input and Output Equalization (EQ)Matrix MixerSignal DelayPeak/RMS LimitersSpeaker Line MonitoringLoudspeaker PresetsCrossover FiltersSignal Routing and MonitoringCooling: Continuously variable speed forced-air cooling with front-to-back airflow.Power Supply: Universal Power Supply suitable for 100–240 VAC, 50/60 Hz operation.Input Impedance: 10 kO balanced / 5 kO unbalanced or better.Maximum Input Level: plus 20 dB before compression and plus 26 dB before clipping or better.Monitoring and Protection: Shall provide comprehensive monitoring and protection against over-temperature, short circuit, DC output, overload, clipping and amplifier faults with remote status indication.Control Interface: Ethernet-based configuration, monitoring and diagnostics through OEM software.Construction: Standard 19-inch rack mount, maximum 2U height.Compliance: CE/FCC/UL or equivalent international safety certifications.Accessories: All necessary rack mounting accessories, connectors, cables, software licenses (if applicable) and installation hardware shall be included. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57947148
AUTHORITY Government Departments
TENDER VALUE 4.18 Crore
LAST DATE 19-10-2026
Authority
Authority Name Haryana Police Housing Corporation Limited
Work Description Tender for Special Repair Of Harshvardhan Auditorium In Police Complex, Hpa Madhuban.
Basic Detail
Tender No 20267B75112B AEAF 435D 8115 80B7F9ED45C857HHC
Bidding Type Tender
Location
City Karnal
State Haryana
Key Dates
Publish Date 09 Oct 2026
Submission Date 19 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 4.18 Crore
Tender Fee 17700
EMD 8.36 Lakhs
Exemption Available
Document List
1YBA99Z177395.pdf
BOQ_633039.xls
f01b8056-92e9-47c8-8f90-7d169651ff23.html
OT0177395.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

1YBA99Z177395.pdf

xls

BOQ_633039.xls

html

f01b8056-92e9-47c8-8f90-7d169651ff23.html

pdf

OT0177395.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders