Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #57946899

Tender For Maint/Repair & Replacement In Lt Distribution Network Alongwith Replacement Of Oh Lines And Allied Works At Afs Yelahanka.

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
35 Lakhs
Estimated cost
Bid Submission
30 Oct 2026
1 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maint/Repair & Replacement In Lt Distribution Network Alongwith Replacement Of Oh Lines And Allied Works At Afs Yelahanka.

BOQ

Name of Work:- MAINT/REPAIR & REPLACEMENT IN LT DISTRIBUTION NETWORK ALONGWITH REPLACEMENT OF OH LINES AND ALLIED WORKS AT AFS YELAHANKA.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and directed.
2Returning filling in excavated soil up to a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and directed.
3Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
4Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm complete all as specified and directed.
5Supply and laying in trenches, LT underground cable of size 16 Sqmm 4 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as specified and directed.
6All as per item No 5 here-in-before but 25 Sqmm 3.5 core
7All as per item No 5 here-in-before but 35 Sqmm 3.5 core
8All as per item No 5 here-in-before but 50 Sqmm 3.5 core
9All as per item No 5 here-in-before but 70 Sqmm 3.5 core
10All as per item No 5 here-in-before but 95 Sqmm 3.5 core
11All as per item No 5 here-in-before but 120 Sqmm 3.5 core Note: For Sl No 5 to 11 necessary excavation and connected items shall be measured and paid separately under respective items of this schedule.
12M & L for boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure complete all as specified and directed.
13Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc. For protection of UG cable complete all as specified and directed
14Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc. For protection of UG cable complete all as specified and directed
15Supply and fix cable route indicator made out of 3 mm thick MS sheet of size 30 cm x 20 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size of cable with white paint, mounted on angle iron 50x50x5 mm, angle height 75 cm, (45cm below ground level) with PCC 30cmx30cmx.60cm complete all as specified and directed.
16Supply, installation and commissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coarse of synthetic enamel paint over a coat of rex oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 125 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 16 KA as incomer and 03 Nos 40 Amps TPN as outgoing including taking down old terminal boxes complete all as specified and directed.
17Supply and fix in repair bus bar box of size 450x300x500mm fabricated by 3 mm thick MS sheet outdoor type, dust/vermin proof, mounted/fixed on angle Iron frame of MS equal angle size 40x40x6mm of height 0.90 mtr, erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate and including aluminium bus bar flat of size 50x6 mm fixed as bus bar over the insulators, sleeved for three phase and neutral, Multifunctional VAF Meter , RYB Indicator -01 Set of 03, and spray painting the box with two coats of enamel paint over a coat of metal primer including necessary excavation, PCC for fixing the box complete all as specified and directed.
18Supply, install, testing and commissioning in repair of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable complete all as specified and directed. at site removing of existing panel and comprising of the following: INCOMING:-MCCB 4 pole 200 Amps 25 kA - 01 Nos OUTGOING:-MCCB 4 pole 100 Amps 25 kA - 01 NosMCCB 4 pole 63 Amps 25 kA - 02 Nos MCCB 3Pole 40Amps 16 kA - 04 Nos Multifunctional VAF meter, PF meter - 1 No RYB Neon indicating lamp -1 set for each outgoing and incoming MS work incl angle iron frame and PCC workSpace for mounting of additional MCB In future.Internal wiring including copper lugs
19Supply, install, testing and commissioning in repair of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable complete all as specified and directed at site and comprising of the following: INCOMINGMCCB 4 pole 160 Amps 25 kA - 01 Nos OUTGOINGMCCB 4 pole 100 Amps 25 kA - 01 NosMCCB 4 pole 63 Amps 16 kA - 04 Nos MCCB 3 pole 40 Amps 16 kA - 01 Nos Multifunctional VAF meter, PF meter - 1 No RYB Neon indicating lamp -1 set of three MS work incl angle iron frame and PCC workInternal wiring including copper lugsNote: Bottom portion of the Panels should Minium 45 cms above the ground level
20Supply, install, testing and commissioning in repair of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable complete all as specified and directed at site and comprising of the following: INCOMINGMCCB 4 pole 125 Amps 25 kA - 01 Nos OUTGOINGMCCB 4 pole 40 Amps 16 kA - 01 NosMCCB 4 pole 63 Amps 16 kA - 01 Nos MCB DP 32 Amp 10 kA - 01 Nos Multifunctional VAF meter, PF meter - 1 No RYB Neon indicating lamp -1 set of three MS work incl angle iron frame and PCC workInternal wiring including copper lugsNote: Bottom portion of the Panels should Minium 45 cms above the ground level
21Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 25 Sqmm to 3.5x 95 Sqmm LT XLPE cable and testing after jointing complete all as specified and directed.
22Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for3.5x 120 Sqmm to 3.5x 240 Sqmm LT XLPE cable and testing after jointing complete all as specified and directed.
23Supply and fix in repair CTs suitable for existing LT panel board of capacity 250 to 320 Amps complete all as specified and directed.
24Supply and fix in repair CTs suitable for existing LT panel board of capacity 63 to 200 Amps complete all as specified and directed.
25Supply and fix in repair LED indicator lamps (R Y B) suitable for existing panel all omplete all as pecified and directed.
26Supply and fix in repair MCCB 200 Amps, 4 pole 36 KA adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
27Supply and fix in repair MCCB 125 Amps 4 pole 16KA, adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
28Supply and fix in repair MCCB 100 Amps 4 pole 16 KA adjustable thermal setting type and confirming to IEC 60947-II complete all as specified and directed.
29Supply and fix in repair MCCB 63 Amps 4 pole 16KA adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed.
30Supply and fix aluminium lugs suitable for UG cable of size 6 Sqmm to 25 Sqmm complete all as specified and as directed.
31All as per item No 30 but of size 35 Sqmm to 50 Sqmm.
32All as per item No 30 but of size 70 to 95 Sqmm.
33All as per item No 30 but of size 120 to 185 Sqmm.
34All as per item No 30 but of size 240 to 300 Sqmm.
35Material and labour for carrying out repair of existing LT panel/ loop in loop out boxes by welding to the door / hinges of any size / type and Spray painting with synthetic enamel gray paint including cleaning of surrounding of LT Panel up to 1 Sqm replacement of unsv lug complete all as specified and directed. Please Enable Macros to View BoQ information
36Material and labour for carrying out repair of existing LT panel/ loop in loop out boxes by welding to the door / hinges of any size / type and Spray painting with synthetic enamel gray paint including cleaning of surrounding of LT Panel up to 1 Sqm replacement of unsv lug complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57946899
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 30-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maint/Repair & Replacement In Lt Distribution Network Alongwith Replacement Of Oh Lines And Allied Works At Afs Yelahanka.
Basic Detail
Tender No 8620/E8
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 09 Oct 2026
Submission Date 30 Oct 2026
Open Date 06 Nov 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
9f618b89-37e8-4021-a046-2d42b1bcec8c.html
Binder1.pdf
BOQ_889357.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Nov 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

9f618b89-37e8-4021-a046-2d42b1bcec8c.html

pdf

Binder1.pdf

xls

BOQ_889357.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender