Power Government Departments Closing in 10 days TDR #57944765

Tender For Work Of Erecton Of New 200Kva Transformer For Releasing Lt Connection Of Ronald Fernandes In Sy No 68/1-F At Cacnamoddi Cuncolim,Salcete-Margao

Issued by Government Departments · goa, Goa
Tender Value
53.63 Lakhs
Estimated cost
Bid Submission
28 Oct 2026
10 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Of Erecton Of New 200Kva Transformer For Releasing Lt Connection Of Ronald Fernandes In Sy No 68/1-F At Cacnamoddi Cuncolim,Salcete-Margao

BOQ

Name of Work:- Work of erecton of new 200KVA Transformer for releasing LT connection of Ronald Fernandes in Sy no 68/1-F at Cacnamoddi Cuncolim,Salcete-Margao
Sl. No. Item Description
1COST OF MATERIAL
2Supply of 3 core, 300 sq.mm. aluminium, XLPE insulated, Flat Type armoured, 11KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK (for the Ring Main System) by Open Trenching Method.
3Supply of 3 core, 95sq.mm. aluminium, XLPE insulated, Flat Type armoured, 11KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK (for the Ring Main Unit to Distr. Transformer)(Double Run)
4Supply of 3 WAY RMU 11KV, 630A, 21 KA 3 Sec, SF6 Outdoor RMU- 2LBS + 1CB Extensible/Non Extensible Two (2) motor operated load break switches (LBSs) with manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with bstteries required for Electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
5Supply of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.Make:- Raychem
6Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm including sockets /lugs / connectors etc.Make:- Raychem
7Supply of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc. Make:- Raychem
8Supply of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc.Make:- Raychem
9Supply of Cable route Markers (for entire route length) as per technical specification and drawing.
10Supply, Laying of Warning Tapes (for entire route length) as per technical specification and drawing.
11Design, Supply & Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 150 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.
12Design, Supply of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.
13Supply of 3 phase, 50Hz, 11/0.433KV, 200KVA, Distribution Transformer complete, suitable for outdoor use and for plinth mounting.
14GI Tubular Fencing complete with gate side dismantling system as per the specfication of Distribution Transformer and Feeder Panels ( size 4Mx 3Mx 2M) with conctreting of GI Fencing supports with Plinth (0.3 x 0.3 x 0.5) Cu mt x 12 Nos. Eaxg ratio 1:3:6 and brick masonary. (Galvanising should be hot dipped Galvanised as per IS2629/66, minimum Zinc coating of 1000 gms/sq. mtrs, 140 Microns DFT, suitable for high salinity coastal areas).
15Supply of Distribution Transformer metering unit.
16Supply and fixing of CAMR Modem as per technical specification.
17Supply of 3½ core, 185 sq.mm. aluminium, XLPE insulated, Flat Type armoured, 1.1KV (Earthed) Cable, and carrying ISI MARK
18Supply of 3½ core, 120 sq.mm. aluminium, XLPE insulated, Flat Type armoured, 1.1KV (Earthed) Cable, and carrying ISI MARK
19185 lugs
20120 Lugs
21200KVA LV Panel fuse type (Double Front MS)
22Supply of RCC protective covers of size 600mm long x 250mm width & 50mm thick capable of bearing load of 135kg & covered with earth/sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
23Supply and laying of fine river sand of approved quality (except sandy soil) for cushioning of 11KV/LT underground cables.
24Supply and laying of burnt clay wire cut bricks of 75 Kgs class.Wire cut bricks.
25Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded granitic or basaltic stone aggregate 40 m nominal size for foundation of Ring Main Unit, Load Break Switch, Transformer & LV SwitchBoard
26Centering and shuttering including struttings, propping etc and removal of form work for Ring Main Unit, Load Break Switch, Transformer & LV SwitchBoard.
27Providing of 12 mm cement plaster 1:4 (1- cement: 4-fine sand ) for foundations of Ring Main Unit, Load Break Switch, Transformer & LV SwitchBoard.
28Brick work using common burnt clay building bricks in cement mortar 1:4 ( 1 cement; 4 coarse sand) in foundation and Plinth(b) with bricks of class designation 75 kgs/sq.cm ( wire cut bricks) for TRANSFORMER foundations.
29Earthing complete with 40mm GI pipe, 2.5mts long alongwith Batonite complete with brick masonary.
30Supply of HDGI flat of size 50mm x 6 mm including supply and fixing of required quantity of HDGI nut bolts for earthing of all euipment.
31COST OF ERECTION
32Testing and Comissioning of 3 core, 300 sq.mm. aluminium, XLPE insulated, Flat Type armoured, 11KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK (for the Ring Main System) by Open Trenching Method.
33Erection, Testing and Comissioning of 3 core, 95sq.mm. aluminium, XLPE insulated, Flat Type armoured, 11KV (Earthed) Cable, type A2XFY conforming I.S. 7098 PART 2 and carrying ISI MARK (for the Ring Main Unit to Distr. Transformer)(Double Run)
34Erection & Commissioning of 3 WAY RMU 11KV, 630A, 21 KA 3 Sec, SF6 Outdoor RMU- 2LBS + 1CB Extensible/Non Extensible Two (2) motor operated load break switches (LBSs) with manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with bstteries required for Electrical operations of RMU is in the scope of the bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no's per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
35Erection, Testing & comissioning of 11KV, three phase, Heat shrinkable, Straight Through Jointing Kit complete for XLPE cable of size 3 core 300sq.mm.Make:- Raychem
36Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 300sq.mm including sockets /lugs / connectors etc.Make:- Raychem
37Erection, Testing and Comissioning of Outdoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc. Make:- Raychem
38Erection, Testing and Comissioning of Indoor type, heat shrinkable, three phase, end termination kit complete, for 11KV XLPE cable of size 3 x 95sq.mm including sockets /lugs / connectors etc.Make:- Raychem
39Erection and Comissioning of Cable route Markers (for entire route length) as per technical specification and drawing.
40Erection of RCC Hume pipes for road crossings, nullah crossings, small river crossings, culverts of 150 mm inner diameter, alongwith required no. of collars, PCC and Masonary work as per technical specifications.
41Erection of Medium duty, HDGI Class B pipe of nominal diameter 150 mm (alongwith HDGI bends wherever required) for bridge crossing, riser pipe for 95Sq.mm & 300Sq.mm XLPE Cable etc., as per technical specifications including supporting arrangement for the pipe.
42Erection, Testing and Comissioning of 3 phase, 50Hz, 11/0.433KV, 200KVA, Distribution Transformer complete, suitable for outdoor use and for plinth mounting.
43GI Tubular Fencing complete with gate side dismantling system as per the specfication of Distribution Transformer and Feeder Panels ( size 4Mx 3Mx 2M) with conctreting of GI Fencing supports with Plinth (0.3 x 0.3 x 0.5) Cu mt x 12 Nos. Eaxg ratio 1:3:6 and brick masonary. (Galvanising should be hot dipped Galvanised as per IS2629/66, minimum Zinc coating of 1000 gms/sq. mtrs, 140 Microns DFT, suitable for high salinity coastal areas).
44Erection of Distribution Transformer metering unit.
45Testing and Comissioning of 3½ core, 185 sq.mm. aluminium, XLPE insulated, Flat Type armoured, 1.1KV (Earthed) Cable, and carrying ISI MARK
46Testing and Comissioning of 3½ core, 120 sq.mm. aluminium, XLPE insulated, Flat Type armoured, 1.1KV (Earthed) Cable, and carrying ISI MARK
47185 lugs
48120 Lugs
49200KVA LV Panel fuse type (Double Front MS)
50Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches drain (not exceeding 1.5 mt in width or 10 sq.m on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m(a) for laying of HT/LT cables of various sizes in all kinds of soil, hard rock , providing barricading, danger lighting guarding etc. The trench lengths are as follows:All kinds of soil/rocks/laterite stone1. Size 1.1 x 0.6 x HT cable length mts for laying of 2 run.
51Filling of available excavated earth (excluding rock/stones) in trench in layer not exceeding 0.2mts. Depth, consolidating each deposited layer by ramming and watering lead up to 40mts.
52laying of RCC protective covers of size 600mm long x 250mm width & 50mm thick capable of bearing load of 135kg & covered with earth/sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
53Earthing complete with 40mm GI pipe, 2.5mts long alongwith Batonite complete with brick masonary.
54Erection of HDGI flat of size 50mm x 6 mm including supply and fixing of required quantity of HDGI nut bolts for earthing of all euipment. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57944765
AUTHORITY Government Departments
TENDER VALUE 53.63 Lakhs
LAST DATE 28-10-2026
Authority
Authority Name Department Of Electricity
Work Description Tender for Work Of Erecton Of New 200Kva Transformer For Releasing Lt Connection Of Ronald Fernandes In Sy No 68/1-F At Cacnamoddi Cuncolim,Salcete-Margao
Basic Detail
Tender No Tender No 14(2026-27)
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 09 Oct 2026
Submission Date 28 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value 53.63 Lakhs
Tender Fee 1000
EMD 1.07 Lakhs
Exemption Not Available
Document List
23900884-0883-473f-a341-dc6757d6cec8.html
BOQ_32617.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

23900884-0883-473f-a341-dc6757d6cec8.html

xls

BOQ_32617.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender